Bridge Statistics for Waycross, Georgia (GA) - Condition, Traffic, Stress, Structural Evaluation, Project CostsBack to: Waycross, GA, Georgia, Georgia forum, All US cities. National Bridge Inventory (NBI) Statistics Number of bridges: 26 Total length: 68 meters (223ft) Total costs: $465,000 Total average daily traffic: 176,730 Total average daily truck traffic: 130 National Bridge Inventory (NBI) Registered Bridges for Waycross
Bridge Condition - Deck Bridge Condition - Superstructure Bridge Condition - Substructure Bridge Condition - Channel Bridge Condition - Culverts Find on map >>
Structure Number: 2990011, Location: CITY LIMITS OF WAYCROSS (Lat: 31.226217, Lng: -82.337867), Route carried "on" structure: US 84, Year Built: 1964, Status: Open, Structure Length: 0.67m (2.20ft), Average Daily Traffic: 16,140 (year 2007), Average Future Daily Traffic: 24,210 (year 2027), Design Load: HS 20+Mod, Features Intersected: SATILLA RIVER TRIB. Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 3.243, Lanes on structure: 5, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 20.0m (65.6ft), Skew: 2 degrees, Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 2, Length of Maximum Span: 3.3m (10.8ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 0.0m Condition: Channel: Very good, Culverts: Good, Operating Rating: 54.9 metric tons, Inventory Rating: 32.4 metric tons, Structural Evaluation: Better than present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007 Find on map >>
Structure Number: 2990018, Location: CITY LIMITS OF WAYCROSS (Lat: 31.226717, Lng: -82.399133), Route carried "on" structure: County highway 591, Year Built: 1924, Year Reconstructed: 1959, Status: Open, Structure Length: 4.72m (15.49ft), Average Daily Traffic: 5,190 (year 2007), Average Future Daily Traffic: 7,785 (year 2027), Design Load: H 15, Features Intersected: KETTLE CREEK, Facility Carried by Structure: ALBANY AVENUE Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.836, Lanes on structure: 2, Base Highway Network: Yes, Owner: County Highway Agency, Approaching Roadway Width: 7.4m (24.3ft), Material/Design: Concrete, Design/Construction: Tee Beam, Number Of Spans In Main Unit: 6, Length of Maximum Span: 10.6m (34.8ft), Curb or Sidewalk Widths: Left: 0.6m (2.0ft), Right: 0.6m (2.0ft), Curb-To-Curb Width: 8.5m (27.9ft), Out-to-Out Width: 10.3m (33.8ft) Condition: Deck: Good, Superstructure: Satisfactory, Substructure: Good, Channel: Very good, Operating Rating: 39.6 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 23.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: High priority of replacement, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 2990021, Location: IN CITY OF WAYCROSS (Lat: 31.214167, Lng: -82.405017), Route carried "on" structure: County highway 1221, Year Built: 1948, Status: Open, Structure Length: 1.76m (5.77ft), Average Daily Traffic: 1,630 (year 2007), Average Future Daily Traffic: 2,445 (year 2027), Design Load: H 15, Features Intersected: KETTLE CREEK, Facility Carried by Structure: CARSWELL ROAD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 2.572, Lanes on structure: 2, Base Highway Network: Yes, Owner: County Highway Agency, Approaching Roadway Width: 7.0m (23.0ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 5, Length of Maximum Span: 3.0m (9.8ft) Condition: Channel: Very good, Culverts: Good, Operating Rating: 41.4 metric tons, Inventory Rating: 24.3 metric tons, Structural Evaluation: Equal to present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007 Find on map >>
Structure Number: 299003, Location: CITY OF WAYCROSS (Lat: 31.208250, Lng: -82.361800), Route carried "on" structure: US 82, Year Built: 1981, Status: Open, Structure Length: 7.98m (26.18ft), Average Daily Traffic: 20,840 (year 2007), Average Future Daily Traffic: 31,260 (year 2027), Design Load: HS 20+Mod, Features Intersected: CSX RR- SR 38 PLANT AVE Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 3.589, Lanes on structure: 4, Lanes under structure: 3, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 16.0m (52.5ft), Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 2, Length of Maximum Span: 42.0m (137.8ft), Curb-To-Curb Width: 15.8m (51.8ft), Out-to-Out Width: 16.8m (55.1ft) Condition: Deck: Good, Superstructure: Very good, Substructure: Good, Operating Rating: 81.9 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 48.6 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Meets minimum limits, Underclear: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: December 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 2990031, Location: CITY OF WAYCROSS (Lat: 31.206833, Lng: -82.359983), Route carried "on" structure: US 82, Year Built: 1981, Status: Open, Structure Length: 3.07m (10.07ft), Average Daily Traffic: 20,840 (year 2007), Average Future Daily Traffic: 31,260 (year 2027), Design Load: HS 20+Mod, Features Intersected: M-5201 HAINES AVENUE Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 3.612, Lanes on structure: 4, Lanes under structure: 4, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 16.6m (54.5ft), Skew: 1 degrees, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 1, Length of Maximum Span: 30.7m (100.7ft), Curb-To-Curb Width: 15.8m (51.8ft), Out-to-Out Width: 16.8m (55.1ft) Condition: Deck: Good, Superstructure: Very good, Substructure: Good, Operating Rating: 72.0 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 43.2 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Meets minimum limits, Underclear: Better than present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: December 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 2990059, Location: IN CITY LIMITS WAYCROSS (Lat: 31.197483, Lng: -82.357967), Route carried "on" structure: City street 5201, Year Built: 1968, Status: Open, Structure Length: 1.21m (3.97ft), Average Daily Traffic: 7,200 (year 2007), Average Future Daily Traffic: 10,800 (year 2027), Design Load: H 15, Features Intersected: SATILLA RIVER TRIB., Facility Carried by Structure: BRUNEL STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.061, Lanes on structure: 4, Base Highway Network: Yes, Owner: County Highway Agency, Approaching Roadway Width: 14.8m (48.6ft), Skew: 4 degrees, Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 3, Length of Maximum Span: 3.9m (12.8ft) Condition: Channel: Good, Culverts: Good, Operating Rating: 41.4 metric tons, Inventory Rating: 24.3 metric tons, Structural Evaluation: Equal to present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007 Find on map >>
Structure Number: 299006, Location: IN CITY LIMITS WAYCROSS (Lat: 31.226167, Lng: -82.359650), Route carried "on" structure: City street 5201, Year Built: 1969, Status: Open, Structure Length: 8.01m (26.28ft), Average Daily Traffic: 6,190 (year 2007), Average Future Daily Traffic: 9,285 (year 2027), Design Load: HS 20+Mod, Features Intersected: CSX RAILROAD, Facility Carried by Structure: HAINES AVENUE Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.123, Lanes on structure: 4, Base Highway Network: Yes, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 14.8m (48.6ft), Skew: 4 degrees, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 5, Length of Maximum Span: 27.1m (88.9ft), Curb or Sidewalk Widths: Left: 1.3m (4.3ft), Right: 1.3m (4.3ft), Curb-To-Curb Width: 14.6m (47.9ft), Out-to-Out Width: 18.5m (60.7ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 48.6 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 28.8 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: High priority of replacement, Underclear: Better than present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 2990061, Location: 2 MI E OF SR 38 (Lat: 31.229517, Lng: -82.344783), Route carried "on" structure: City street 5206, Year Built: 1972, Status: Open, Structure Length: 0.70m (2.30ft), Average Daily Traffic: 5,310 (year 2007), Average Future Daily Traffic: 7,965 (year 2027), Design Load: HS 20+Mod, Features Intersected: SATILLA RIVER TRIB., Facility Carried by Structure: TEBEAU STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.299, Lanes on structure: 4, Base Highway Network: Yes, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 20.9m (68.6ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 4, Length of Maximum Span: 2.1m (6.9ft), Curb or Sidewalk Widths: Left: 1.6m (5.2ft), Right: 1.6m (5.2ft) Condition: Channel: Good, Culverts: Very good, Operating Rating: 54.9 metric tons, Inventory Rating: 32.4 metric tons, Structural Evaluation: Equal to present desirable criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007 Find on map >>
Structure Number: 2990062, Location: 1 MI NW OF WAYCROSS (Lat: 31.258000, Lng: -82.388250), Route carried "on" structure: City street 5211, Year Built: 1960, Year Reconstructed: 2004, Status: Open, Structure Length: 3.04m (9.97ft), Average Daily Traffic: 2,010 (year 2007), Average Future Daily Traffic: 3,015 (year 2027), Design Load: H 15, Features Intersected: KETTLE CREEK, Facility Carried by Structure: CHEROKEE STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.273, Lanes on structure: 2, Base Highway Network: Yes, Owner: County Highway Agency, Approaching Roadway Width: 6.7m (22.0ft), Material/Design: Concrete, Design/Construction: Slab, Number Of Spans In Main Unit: 5, Length of Maximum Span: 6.0m (19.7ft), Curb-To-Curb Width: 7.1m (23.3ft), Out-to-Out Width: 7.7m (25.3ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Channel: Very good, Operating Rating: 46.8 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 27.9 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: High priority of replacement, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Underwater Inspection Frequency: Every 60 months, Inspection Date: December 2007, Underwater Inspection Date: June 2005, Deck Structure Type: Concrete Precast Panels, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 2990063, Location: IN CITY LIMITS WAYCROSS (Lat: 31.227850, Lng: -82.330300), Route carried "on" structure: City street 5211, Year Built: 1960, Status: Open, Structure Length: 1.43m (4.69ft), Average Daily Traffic: 7,640 (year 2007), Average Future Daily Traffic: 11,460 (year 2027), Design Load: H 15, Features Intersected: SATILLA RIVER TRIB., Facility Carried by Structure: BLACKSHEAR AVENUE Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 1.012, Lanes on structure: 2, Base Highway Network: Yes, Owner: County Highway Agency, Approaching Roadway Width: 6.1m (20.0ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 4, Length of Maximum Span: 3.0m (9.8ft) Condition: Channel: Good, Culverts: Fair, Operating Rating: 41.4 metric tons, Inventory Rating: 24.3 metric tons, Structural Evaluation: Somewhat better than minimum adequacy, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007 Find on map >>
Structure Number: 2990074, Location: 2 MI W OF WAYCROSS (Lat: 31.209167, Lng: -82.406733), Route carried "on" structure: US 82, Year Built: 1984, Status: Open, Structure Length: 0.97m (3.18ft), Average Daily Traffic: 11,530 (year 2007), Average Future Daily Traffic: 17,295 (year 2027), Design Load: HS 20+Mod, Features Intersected: KETTLE CREEK Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 3.150, Lanes on structure: 4, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 18.8m (61.7ft), Skew: 12 degrees, Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 3, Length of Maximum Span: 3.0m (9.8ft) Condition: Channel: Very good, Culverts: Very good, Operating Rating: 54.9 metric tons, Inventory Rating: 32.4 metric tons, Structural Evaluation: Equal to present desirable criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007 Find on map >>
Structure Number: 2990075, Location: CITY OF WAYCROSS (Lat: 31.208700, Lng: -82.379833), Route carried "on" structure: US 82, Year Built: 1984, Status: Open, Structure Length: 4.75m (15.58ft), Average Daily Traffic: 23,630 (year 2007), Average Future Daily Traffic: 35,445 (year 2027), Design Load: HS 20+Mod, Features Intersected: CSX RAILROAD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 3.523, Lanes on structure: 5, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 20.6m (67.6ft), Skew: 1 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 21.0m (68.9ft), Curb or Sidewalk Widths: Left: 1.8m (5.9ft), Right: 1.8m (5.9ft), Curb-To-Curb Width: 20.1m (65.9ft), Out-to-Out Width: 24.5m (80.4ft) Condition: Deck: Very good, Superstructure: Very good, Substructure: Very good, Operating Rating: 54.9 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 27.9 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Somewhat better than minimum adequacy, Underclear: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: December 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 2995075, Location: 1.5 MI W OF WAYCROSS (Lat: 31.227967, Lng: -82.399600), Route carried "on" structure: County highway 308, Year Built: 1989, Status: Open, Structure Length: 1.34m (4.40ft), Average Daily Traffic: 870 (year 2007), Average Future Daily Traffic: 1,305 (year 2027), Design Load: HS 20+Mod, Features Intersected: KETTLE CREEK TRIB., Facility Carried by Structure: RED KEEN STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.008, Lanes on structure: 2, Base Highway Network: Yes, Owner: County Highway Agency, Approaching Roadway Width: 6.1m (20.0ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 4, Length of Maximum Span: 3.0m (9.8ft) Condition: Channel: Very good, Culverts: Very good, Operating Rating: 54.9 metric tons, Inventory Rating: 32.4 metric tons, Structural Evaluation: Equal to present desirable criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007 Find on map >>
Structure Number: 2995076, Location: 2 MI W OF WAYCROSS (Lat: 31.229100, Lng: -82.403250), Route carried "on" structure: City street 5213, Year Built: 1960, Status: Open, Structure Length: 0.97m (3.18ft), Average Daily Traffic: 2,150 (year 2007), Average Future Daily Traffic: 3,225 (year 2027), Design Load: H 15, Features Intersected: KETTLE CREEK TRIB., Facility Carried by Structure: GORMAN STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.275, Lanes on structure: 2, Base Highway Network: Yes, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 7.0m (23.0ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 3, Length of Maximum Span: 3.0m (9.8ft) Condition: Channel: Good, Culverts: Good, Operating Rating: 41.4 metric tons, Inventory Rating: 24.3 metric tons, Structural Evaluation: Equal to present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007 Find on map >>
Structure Number: 2995082, Location: CITY OF WAYCROSS (Lat: 31.225833, Lng: -82.340617), Route carried "on" structure: City street 608, Year Built: 1960, Status: Open, Structure Length: 1.37m (4.49ft), Average Daily Traffic: 870 (year 2007), Average Future Daily Traffic: 1,305 (year 2027), Design Load: H 15, Features Intersected: SATILLA RIVER TRIB., Facility Carried by Structure: RICARDO STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.011, Lanes on structure: 2, Base Highway Network: Yes, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 6.4m (21.0ft), Material/Design: Concrete, Design/Construction: Slab, Number Of Spans In Main Unit: 3, Length of Maximum Span: 4.5m (14.8ft), Curb or Sidewalk Widths: Left: 0.1m (0.3ft), Right: 0.1m (0.3ft), Curb-To-Curb Width: 7.3m (24.0ft), Out-to-Out Width: 7.7m (25.3ft) Condition: Deck: Good, Superstructure: Good, Substructure: Fair, Channel: Satisfactory, Operating Rating: 46.8 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 27.9 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: Meets minimum limits, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Length Of Structure Improvement: 41.63m (136.58ft), Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007, Bridge Improvement Cost: $67,000, Roadway Improvement Cost: $251,000, Total Project Cost: $358,000, Deck Structure Type: Concrete Precast Panels, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 2995083, Location: CITY OF WAYCROSS (Lat: 31.236667, Lng: -82.348967), Route carried "on" structure: City street 611, Year Built: 1950, Status: Open, Structure Length: 0.60m (1.97ft), Average Daily Traffic: 870 (year 2007), Average Future Daily Traffic: 1,305 (year 2027), Design Load: H 15, Features Intersected: SATILLA RIVER TRIB., Facility Carried by Structure: SCREVEN AVENUE Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.165, Lanes on structure: 2, Base Highway Network: Yes, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 9.5m (31.2ft), Material/Design: Steel, Design/Construction: Culvert, Number Of Spans In Main Unit: 1, Length of Maximum Span: 6.0m (19.7ft), Curb or Sidewalk Widths: Left: 0.6m (2.0ft), Right: 0.9m (3.0ft) Condition: Channel: Very good, Culverts: Good, Operating Rating: 41.4 metric tons, Inventory Rating: 24.3 metric tons, Structural Evaluation: Equal to present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007 Find on map >>
Structure Number: 2995084, Location: CITY OF WAYCROSS (Lat: 31.226483, Lng: -82.338833), Route carried "on" structure: City street 619, Year Built: 1955, Year Reconstructed: 1998, Status: Posted for load, Structure Length: 1.37m (4.49ft), Average Daily Traffic: 870 (year 2007), Average Future Daily Traffic: 1,305 (year 2027), Design Load: H 15, Features Intersected: SATILLA RIVER TRIB., Facility Carried by Structure: CITY BOULEVARD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.075, Lanes on structure: 2, Base Highway Network: Yes, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 9.5m (31.2ft), Material/Design: Concrete, Design/Construction: Slab, Number Of Spans In Main Unit: 3, Length of Maximum Span: 4.5m (14.8ft), Curb or Sidewalk Widths: Left: 0.1m (0.3ft), Right: 0.1m (0.3ft), Curb-To-Curb Width: 7.3m (24.0ft), Out-to-Out Width: 7.7m (25.3ft) Condition: Deck: Good, Superstructure: Good, Substructure: Satisfactory, Channel: Very good, Operating Rating: 29.7 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 18.9 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: Meets minimum limits, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below), Length Of Structure Improvement: 7.83m (25.69ft), Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007, Bridge Improvement Cost: $50,000, Roadway Improvement Cost: $40,000, Total Project Cost: $107,000, Deck Structure Type: Concrete Precast Panels, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 2995086, Location: CITY OF WAYCROSS (Lat: 31.222783, Lng: -82.345667), Route carried "on" structure: City street 609, Year Built: 1972, Status: Open, Structure Length: 1.03m (3.38ft), Average Daily Traffic: 870 (year 2007), Average Future Daily Traffic: 1,305 (year 2027), Design Load: HS 20+Mod, Features Intersected: SATILLA RIVER TRIB., Facility Carried by Structure: DARLING AVENUE Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.022, Lanes on structure: 2, Base Highway Network: Yes, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 13.5m (44.3ft), Skew: 5 degrees, Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 2, Length of Maximum Span: 4.8m (15.7ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 0.0m Condition: Channel: Very good, Culverts: Good, Operating Rating: 54.9 metric tons, Inventory Rating: 32.4 metric tons, Structural Evaluation: Better than present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007 Find on map >>
Structure Number: 2995088, Location: WAYCROSS-SOUTHSIDE C/L (Lat: 31.225833, Lng: -82.361667), Route carried "on" structure: City street 678, Year Built: 1984, Status: Open, Structure Length: 0.73m (2.40ft), Average Daily Traffic: 870 (year 2007), Average Future Daily Traffic: 1,305 (year 2027), Design Load: HS 20+Mod, Features Intersected: SATILLA RIVER TRIB., Facility Carried by Structure: MARION STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.072, Lanes on structure: 2, Base Highway Network: Yes, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 9.5m (31.2ft), Skew: 2 degrees, Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 3, Length of Maximum Span: 2.1m (6.9ft) Condition: Channel: Very good, Culverts: Good, Operating Rating: 54.9 metric tons, Inventory Rating: 32.4 metric tons, Structural Evaluation: Better than present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007 Find on map >>
Structure Number: 2995089, Location: IN WAYCROSS CITY LIMITS (Lat: 31.199350, Lng: -82.356633), Route carried "on" structure: City street 730, Year Built: 1990, Status: Open, Structure Length: 0.70m (2.30ft), Average Daily Traffic: 870 (year 2007), Average Future Daily Traffic: 1,305 (year 2027), Design Load: HS 20+Mod, Features Intersected: SATILLA RIVER TRIB., Facility Carried by Structure: WALTERS STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.049, Lanes on structure: 2, Base Highway Network: Yes, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 8.0m (26.2ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 3, Length of Maximum Span: 2.1m (6.9ft) Condition: Channel: Very good, Culverts: Good, Operating Rating: 54.9 metric tons, Inventory Rating: 32.4 metric tons, Structural Evaluation: Better than present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007 Find on map >>
Structure Number: 299003, Location: CITY OF WAYCROSS (Lat: 31.208250, Lng: -82.361800), Route carried "under" structure: US 82, Year Built: 1981, Structure Length: 7.98m (26.18ft), Average Daily Traffic: 6,900 (year 1998), Truck Traffic: 1%, Features Intersected: SR 520 - US 82 - COR Z, Facility Carried by Structure: PLANT AVENUE Minimum Vertical Clearance: 7.41m (24.31ft), Kilometerpoint: 0.295, Lanes on structure: 4, Lanes under structure: 3, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 42.0m (137.8ft) Find on map >>
Structure Number: 2990031, Location: CITY OF WAYCROSS (Lat: 31.206833, Lng: -82.359983), Route carried "under" structure: City street 5201, Year Built: 1981, Structure Length: 3.07m (10.07ft), Average Daily Traffic: 6,170 (year 1998), Truck Traffic: 1%, Features Intersected: SR 520 - US 82 - COR Z, Facility Carried by Structure: HAINES AVENUE Minimum Vertical Clearance: 5.41m (17.75ft), Kilometerpoint: 0.168, Lanes on structure: 4, Lanes under structure: 4, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 30.7m (100.7ft) Find on map >>
Structure Number: 2990064, Location: CITY LIMITS OF WAYCROSS (Lat: 31.211900, Lng: -82.355617), Route carried "under" structure: Business US 1, Year Built: 1948, Structure Length: 2.28m (7.48ft), Average Daily Traffic: 11,400 (year 2007), Features Intersected: SR 4 BUS. US 1 BUS, Facility Carried by Structure: CSX RAILROAD Minimum Vertical Clearance: 4.39m (14.40ft), Kilometerpoint: 0.199, Lanes under structure: 4, Material/Design: Concrete continuous, Design/Construction: Slab, Length of Maximum Span: 11.2m (36.7ft) Find on map >>
Structure Number: 2990065, Location: CITY LIMITS OF WAYCROSS (Lat: 31.213017, Lng: -82.357117), Route carried "under" structure: City street 5205, Year Built: 1941, Structure Length: 2.49m (8.17ft), Average Daily Traffic: 5,070 (year 2007), Features Intersected: M-5205 CARSWELL AVE., Facility Carried by Structure: CSX RR (637696S) Minimum Vertical Clearance: 4.41m (14.47ft), Kilometerpoint: 0.424, Lanes under structure: 4, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 10.0m (32.8ft) Find on map >>
Structure Number: 2990066, Location: INT OF M-5219 & SR 38 (Lat: 31.224833, Lng: -82.348583), Route carried "under" structure: City street 5219, Year Built: 1975, Structure Length: 4.08m (13.39ft), Average Daily Traffic: 9,930 (year 2007), Features Intersected: M-5219 AVENUE STREET, Facility Carried by Structure: CSX RAILROAD Minimum Vertical Clearance: 4.36m (14.30ft), Kilometerpoint: 0.001, Lanes under structure: 3, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 18.2m (59.7ft) Find on map >>
Structure Number: 2995085, Location: IN WAYCROSS (Lat: 31.212567, Lng: -82.353817), Route carried "under" structure: City street 708, Year Built: 1950, Structure Length: 2.07m (6.79ft), Average Daily Traffic: 870 (year 2007), Features Intersected: CR 708 LEE AVE., Facility Carried by Structure: CSX RAILROAD Minimum Vertical Clearance: 3.65m (11.98ft), Kilometerpoint: 0.218, Lanes under structure: 2, Material/Design: Concrete, Design/Construction: Slab, Length of Maximum Span: 5.1m (16.7ft) Discuss this city on our hugely popular Georgia forum Back to: Waycross, GA, Georgia, All US cities.
|
![]() |