Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Windsor, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 38Number of bridges
  • 341ft / 104mTotal length
  • $2,109,000Total costs
  • 409,792Total average daily traffic
  • 34,787Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Windsor
  • No street view available for this location

New bridges in Windsor, CA - historical statistics
  • New bridges - historical statistics
  • 31910-1919
  • 21920-1929
  • 11940-1949
  • 21950-1959
  • 161960-1969
  • 11970-1979
  • 41980-1989
  • 41990-1999
  • 32000-2009
  • 22010-2019
Reconstructed bridges in Windsor, CA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11920-1929
  • 01930-1939
  • 01940-1949
  • 01950-1959
  • 01960-1969
  • 01970-1979
  • 11980-1989
  • 11990-1999
  • 12000-2009
Average Bridge Daily Traffic in Windsor, CA
Average Bridge Truck Traffic in Windsor, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 41.7%Good
  • 4.2%Satisfactory
  • 41.7%Fair
  • 12.5%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 55.2%Good
  • 37.9%Fair
  • 6.9%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 86.2%Good
  • 13.8%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 17.9%Very good
  • 71.4%Good
  • 10.7%Satisfactory
Find on map >>   Show street view

Structure Number: 20 0061L,  Location: 04-SON-101-30.67 (Lat: 38.561656,  Lng: -122.822958),  Route carried "on" structure: US 101,  Year Built: 1962,  Status: Open,  Structure Length: 4.27m (14.01ft),  Average Daily Traffic: 22,500 (year 2013),  Truck Traffic: 15%,  Average Future Daily Traffic: 41,886 (year 2038),  Design Load: HS 20,  Features Intersected: ARATA LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 30.670,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.1m (39.7ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 28.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 21.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.27m (14.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 20 0061R,  Location: 04-SON-101-30.67 (Lat: 38.561653,  Lng: -122.822642),  Route carried "on" structure: US 101,  Year Built: 1962,  Status: Open,  Structure Length: 4.27m (14.01ft),  Average Daily Traffic: 22,750 (year 2017),  Truck Traffic: 15%,  Average Future Daily Traffic: 50,753 (year 2038),  Design Load: HS 20,  Features Intersected: ARATA LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 30.670,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.1m (39.7ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 28.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 21.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.27m (14.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 20 0182,  Location: 04-SON-101-27.97 (Lat: 38.530072,  Lng: -122.793764),  Route carried "on" structure: US 101,  Year Built: 1962,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 62,000 (year 2014),  Truck Traffic: 6%,  Average Future Daily Traffic: 142,000 (year 2037),  Design Load: HS 20,  Features Intersected: POOL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 27.970,  Lanes on structure: 6,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 34.2m (112.2ft),  Skew: 32 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.9m (25.9ft),  Curb-To-Curb Width: 34.0m (111.5ft),  Out-to-Out Width: 35.2m (115.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 68.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 20 0184L,  Location: 04-SON-101-29.35 (Lat: 38.546656,  Lng: -122.807989),  Route carried "on" structure: US 101,  Year Built: 1962,  Status: Open,  Structure Length: 9.57m (31.40ft),  Average Daily Traffic: 22,500 (year 2013),  Truck Traffic: 15%,  Average Future Daily Traffic: 41,886 (year 2038),  Design Load: HS 20,  Features Intersected: WINDSOR LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 29.350,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 5 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 26.2m (86.0ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.1m (39.7ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 53.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 9.57m (31.40ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 20 0184R,  Location: 04-SON-101-29.35 (Lat: 38.546478,  Lng: -122.807572),  Route carried "on" structure: US 101,  Year Built: 1962,  Status: Open,  Structure Length: 9.27m (30.41ft),  Average Daily Traffic: 22,750 (year 2015),  Truck Traffic: 15%,  Average Future Daily Traffic: 50,753 (year 2039),  Design Load: HS 20,  Features Intersected: WINDSOR LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 29.350,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 5 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 25.6m (84.0ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.1m (39.7ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 55.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 20 0185,  Location: 04-SON-101-29.50 (Lat: 38.549147,  Lng: -122.809781),  Route carried "on" structure: US 101,  Year Built: 1962,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 45,500 (year 2015),  Truck Traffic: 15%,  Average Future Daily Traffic: 101,507 (year 2038),  Features Intersected: WINDSOR CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 29.500,  Lanes on structure: 9,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 68.0m (223.1ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 20C0007,  Location: 0.2 MI N OF RIVER RD (Lat: 38.485289,  Lng: -122.825553),  Route carried "on" structure: County highway ,  Year Built: 1986,  Status: Open,  Structure Length: 4.13m (13.55ft),  Average Daily Traffic: 3,242 (year 2011),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,732 (year 2044),  Design Load: HS 20+Mod,  Features Intersected: MARK WEST CREEK,  Facility Carried by Structure: SLUSSER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 20.3m (66.6ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 20C0053,  Location: 0.4 MI N SHILO RD (Lat: 38.530122,  Lng: -122.793486),  Route carried "on" structure: County highway ,  Year Built: 1962,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 8,100 (year 2011),  Truck Traffic: 2%,  Average Future Daily Traffic: 11,591 (year 2041),  Design Load: HS 20,  Features Intersected: POOL CREEK,  Facility Carried by Structure: HEMBREE LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.9m (25.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 12.5m (41.0ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 57.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 20C0064,  Location: 4.8 MI WEST OF US 101 (Lat: 38.484553,  Lng: -122.842622),  Route carried "on" structure: County highway ,  Year Built: 1960,  Status: Open,  Structure Length: 15.18m (49.80ft),  Average Daily Traffic: 11,700 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 12,242 (year 2040),  Design Load: HS 20,  Features Intersected: MARK WEST CR, TRENTON RD,  Facility Carried by Structure: RIVER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 10,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 47.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 20C008,  Location: 35.7 MI N MARIN CO LINE (Lat: 38.618403,  Lng: -122.879164),  Route carried "on" structure: County highway ,  Year Built: 1960,  Status: Open,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 1,000 (year 2015),  Truck Traffic: 1%,  Average Future Daily Traffic: 2,116 (year 2038),  Features Intersected: WEST NORTON SLOUGH,  Facility Carried by Structure: KINLEY DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.5m (18.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 20C0086,  Location: 0.5 MI S/O PLEASANT RD (Lat: 38.534208,  Lng: -122.786775),  Route carried "on" structure: County highway ,  Year Built: 1925,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 13,800 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 8,495 (year 2038),  Features Intersected: POOL CREEK,  Facility Carried by Structure: OLD REDWOOD HWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 36.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 20C0089,  Location: 0.7 MI SE EASTSIDE RD (Lat: 38.567147,  Lng: -122.832353),  Route carried "on" structure: County highway ,  Year Built: 1913,  Year Reconstructed: 1925,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 5,900 (year 2009),  Truck Traffic: 6%,  Average Future Daily Traffic: 6,000 (year 2038),  Features Intersected: SOTOYOME CREEK,  Facility Carried by Structure: OLD REDWOOD HWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.4m (21.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 28.2 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 20C0157,  Location: 11.2 MI W OF SR 116 (Lat: 38.482644,  Lng: -122.830986),  Route carried "on" structure: County highway ,  Year Built: 1958,  Status: Open,  Structure Length: 7.13m (23.39ft),  Average Daily Traffic: 8,000 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 10,700 (year 2041),  Design Load: HS 20,  Features Intersected: MARK WEST CREEK,  Facility Carried by Structure: RIVER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 6 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.6m (84.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 27.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 21.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 7.13m (23.39ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Bridge Improvement Cost: $709,000,  Roadway Improvement Cost: $141,000,  Total Project Cost: $1,191,000 ( Estimate for 2017),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 20C0239,  Location: 0.3 MI N OF RIVER RD (Lat: 38.493839,  Lng: -122.852858),  Route carried "on" structure: County highway ,  Year Built: 1988,  Status: Open,  Structure Length: 5.49m (18.01ft),  Average Daily Traffic: 1,700 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,081 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: MARK WEST CREEK,  Facility Carried by Structure: TRENTON HEALDSBRG
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 5.49m (18.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Bridge Improvement Cost: $547,000,  Roadway Improvement Cost: $109,000,  Total Project Cost: $918,000 ( Estimate for 2017),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 20C0241,  Location: 0.8 MI E OF OLD REDWOOD H (Lat: 38.540317,  Lng: -122.780092),  Route carried "on" structure: County highway ,  Year Built: 1925,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 2,000 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,453 (year 2040),  Features Intersected: POOL CREEK,  Facility Carried by Structure: PLEASANT AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.2m (23.6ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 20C0242,  Location: 1 MI S OF SR 128 (Lat: 38.621897,  Lng: -122.773589),  Route carried "on" structure: County highway ,  Year Built: 1915,  Status: Open,  Structure Length: 5.18m (16.99ft),  Average Daily Traffic: 800 (year 2015),  Truck Traffic: 1%,  Average Future Daily Traffic: 419 (year 2040),  Features Intersected: MAACAMA CREEK,  Facility Carried by Structure: CHALK HILL RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 4,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 4.9m (16.1ft),  Out-to-Out Width: 5.5m (18.0ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 29.2 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 17.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 20C0247,  Location: 1.2 MI E OF TRE-HEALDS RD (Lat: 38.510892,  Lng: -122.840031),  Route carried "on" structure: County highway ,  Year Built: 1976,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 400 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 557 (year 2040),  Design Load: HS 20,  Features Intersected: WINDSOR CREEK,  Facility Carried by Structure: MARK WEST STA RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 6.6m (21.7ft),  Out-to-Out Width: 6.8m (22.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 20C0329,  Location: 3 MI SOUTH SR 128 (Lat: 38.610383,  Lng: -122.772728),  Route carried "on" structure: County highway ,  Year Built: 1965,  Status: Open,  Structure Length: 4.75m (15.58ft),  Average Daily Traffic: 850 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,000 (year 2040),  Design Load: HS 20,  Features Intersected: FRANZ CREEK,  Facility Carried by Structure: CHALK HILL RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 71.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 20C033,  Location: 4.5 MI S OF SR 128 (Lat: 38.600269,  Lng: -122.777617),  Route carried "on" structure: County highway ,  Year Built: 1956,  Status: Open,  Structure Length: 1.62m (5.31ft),  Average Daily Traffic: 850 (year 2015),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,000 (year 2040),  Features Intersected: BROOKS CREEK,  Facility Carried by Structure: CHALK HILL RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.9m (25.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Good,  Operating Rating: 36.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 20C0337,  Location: 0.2 MI N OF SHILOH RD (Lat: 38.526933,  Lng: -122.816719),  Route carried "on" structure: County highway ,  Year Built: 1967,  Status: Open,  Structure Length: 2.65m (8.69ft),  Average Daily Traffic: 5,900 (year 2011),  Truck Traffic: 2%,  Average Future Daily Traffic: 7,880 (year 2038),  Design Load: HS 20,  Features Intersected: POOL CREEK,  Facility Carried by Structure: WINDSOR ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.4m (34.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Good,  Channel: Good,  Operating Rating: 61.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 20C0342,  Location: 0.3 MI N OF SILK RD (Lat: 38.517897,  Lng: -122.821375),  Route carried "on" structure: County highway ,  Year Built: 1946,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 1,500 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,918 (year 2040),  Features Intersected: BRANCH WINDSOR CREEK,  Facility Carried by Structure: WINDSOR RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.5m (21.3ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 39.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 20C0502,  Location: 0.1 MI S.E. OF SH101 (Lat: 38.546353,  Lng: -122.806356),  Route carried "on" structure: County highway ,  Year Built: 1991,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 20,000 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 9,780 (year 2038),  Features Intersected: EAST WINDSOR CREEK,  Facility Carried by Structure: OLD REDWOOD HWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: 20C0506,  Location: 320 FT EAST OF BELL AVE (Lat: 38.546517,  Lng: -122.809989),  Route carried "on" structure: County highway ,  Year Built: 1995,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 5,400 (year 2013),  Truck Traffic: 5%,  Average Future Daily Traffic: 9,730 (year 2038),  Features Intersected: WINDSOR CREEK,  Facility Carried by Structure: CONDE LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.9m (25.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 21.5m (70.5ft)

Condition: Superstructure: Fair,  Substructure: Fair,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: 20C0507,  Location: 100 YARDS WEST OF RTE 101 (Lat: 38.547269,  Lng: -122.809875),  Route carried "on" structure: City street ,  Year Built: 1995,  Status: Open,  Structure Length: 2.20m (7.22ft),  Average Daily Traffic: 2,000 (year 2011),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,413 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: WINDSOR CREEK,  Facility Carried by Structure: Old Redwood Hwy
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 19.0m (62.3ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.2m (69.6ft),  Curb or Sidewalk Widths: Left: 2.3m (7.5ft),  Right: 2.3m (7.5ft),  Curb-To-Curb Width: 21.0m (68.9ft),  Out-to-Out Width: 31.2m (102.4ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 20C054,  Location: AT VINTAGE GREENS ROAD (Lat: 38.534314,  Lng: -122.816617),  Route carried "on" structure: Business City street ,  Year Built: 2005,  Status: Open,  Structure Length: 2.11m (6.92ft),  Average Daily Traffic: 5,000 (year 2013),  Truck Traffic: 3%,  Average Future Daily Traffic: 7,310 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: WINDSOR CREEK,  Facility Carried by Structure: WINDSOR ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 13.8m (45.3ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.1m (69.2ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 13.8m (45.3ft),  Out-to-Out Width: 17.5m (57.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 20C057,  Location: 1.45 MI E/O SR 1 (Lat: 38.435069,  Lng: -123.086914),  Route carried "on" structure: County highway ,  Year Built: 2011,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 170 (year 2010),  Truck Traffic: 1%,  Average Future Daily Traffic: 210 (year 2040),  Design Load: HL 93,  Features Intersected: WILLOW CREEK,  Facility Carried by Structure: WILLOW CREEK ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.4m (24.3ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.9m (45.6ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 8.3m (27.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2022,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 20C0575,  Location: 0.1 MI EAST OF CONDE LANE (Lat: 38.525533,  Lng: -122.795869),  Route carried "on" structure: Business City street ,  Year Built: 2012,  Status: Open,  Structure Length: 1.90m (6.23ft),  Average Daily Traffic: 20,000 (year 2013),  Truck Traffic: 5%,  Average Future Daily Traffic: 28,000 (year 2036),  Design Load: HL 93,  Features Intersected: PRUITT CREEK,  Facility Carried by Structure: SHILOH ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.5m (31.2ft)

Condition: Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2019
Find on map >>   Show street view

Structure Number: 20C0576,  Location: 200 FT S OF SHILOH ROAD (Lat: 38.525058,  Lng: -122.792997),  Route carried "on" structure: Business City street ,  Year Built: 1987,  Status: Open,  Structure Length: 2.07m (6.79ft),  Average Daily Traffic: 10,000 (year 2013),  Truck Traffic: 20%,  Average Future Daily Traffic: 14,000 (year 2038),  Features Intersected: PRUITT CREEK,  Facility Carried by Structure: CALETTI AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 16.3m (53.5ft),  Skew: 3 degrees,  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.3m (66.6ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 13.9m (45.6ft),  Out-to-Out Width: 15.5m (50.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 30.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 17.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 20C0577,  Location: 200 FT S OF JESSICA DRIVE (Lat: 38.555978,  Lng: -122.810336),  Route carried "on" structure: Business City street ,  Year Built: 1988,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 3,000 (year 2013),  Truck Traffic: 3%,  Average Future Daily Traffic: 4,000 (year 2036),  Features Intersected: WINDSOR CREEK,  Facility Carried by Structure: NATALIE DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.8m (12.5ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 16.2m (53.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2019,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 20C0578,  Location: 400 FT NW OFJOSHUA DR (Lat: 38.540272,  Lng: -122.810297),  Route carried "on" structure: Business City street ,  Year Built: 2007,  Status: Open,  Structure Length: 1.33m (4.36ft),  Average Daily Traffic: 3,000 (year 2013),  Truck Traffic: 3%,  Average Future Daily Traffic: 4,081 (year 2041),  Design Load: HS 20,  Features Intersected: EAST WINDSOR CREEK,  Facility Carried by Structure: BELL ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.3m (43.6ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2019
Find on map >>   Show street view

Structure Number: 20C0579,  Location: 300 FT N OF 19TH HOLE DR (Lat: 38.527489,  Lng: -122.800350),  Route carried "on" structure: Business City street ,  Year Built: 1997,  Status: Open,  Structure Length: 3.44m (11.29ft),  Average Daily Traffic: 3,000 (year 2013),  Truck Traffic: 3%,  Average Future Daily Traffic: 4,000 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: POOL CREEK,  Facility Carried by Structure: GOLF COURSE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 34.4m (112.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 20C058,  Location: 0.2 MI N OF SHILOH RD (Lat: 38.527692,  Lng: -122.797983),  Route carried "on" structure: Business City street ,  Year Built: 2008,  Status: Open,  Structure Length: 2.38m (7.81ft),  Average Daily Traffic: 3,000 (year 2013),  Truck Traffic: 3%,  Average Future Daily Traffic: 4,000 (year 2038),  Design Load: HS 20,  Features Intersected: POOL CREEK,  Facility Carried by Structure: CONDE LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 10.0m (32.8ft),  Skew: 26 degrees,  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.9m (71.9ft)

Condition: Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: 20 0061L,  Location: 04-SON-101-30.67 (Lat: 38.561656,  Lng: -122.822958),  Route carried "under" structure: City street ,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 780 (year 2014),  Truck Traffic: 2%,  Features Intersected: ARATA LANE,  Facility Carried by Structure: US HIGHWAY 101 SB
Minimum Vertical Clearance: 4.75m (15.58ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 20.1m (65.9ft)

Find on map >>   Show street view

Structure Number: 20 0061R,  Location: 04-SON-101-30.67 (Lat: 38.561653,  Lng: -122.822642),  Route carried "under" structure: City street ,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 1,000 (year 2017),  Truck Traffic: 1%,  Features Intersected: ARATA LANE,  Facility Carried by Structure: US HIGHWAY 101 NB
Minimum Vertical Clearance: 4.60m (15.09ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 20.1m (65.9ft)

Find on map >>   Show street view

Structure Number: 20 0184L,  Location: 04-SON-101-29.35 (Lat: 38.546656,  Lng: -122.807989),  Route carried "under" structure: County highway ,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 1,000 (year 2010),  Truck Traffic: 1%,  Features Intersected: WINDSOR LANE,  Facility Carried by Structure: US HIGHWAY 101 SB
Minimum Vertical Clearance: 4.67m (15.32ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 26.2m (86.0ft)

Find on map >>   Show street view

Structure Number: 20 0184R,  Location: 04-SON-101-29.35 (Lat: 38.546478,  Lng: -122.807572),  Route carried "under" structure: County highway ,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 800 (year 2017),  Truck Traffic: 1%,  Features Intersected: WINDSOR LANE,  Facility Carried by Structure: US HIGHWAY 101 NB
Minimum Vertical Clearance: 4.75m (15.58ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 25.6m (84.0ft)

Find on map >>   Show street view

Structure Number: 20 0202,  Location: 04-SON-101-27.62 (Lat: 38.525781,  Lng: -122.790489),  Route carried "under" structure: US 101,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 62,000 (year 2009),  Truck Traffic: 6%,  Features Intersected: U.S. HIGHWAY 101,  Facility Carried by Structure: SHILOH ROAD
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 27.620,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 25.6m (84.0ft)

Find on map >>   Show street view

Structure Number: 20C009,  Location: 32.2 MI N MARIN LINE (Lat: 38.573069,  Lng: -122.840067),  Route carried "under" structure: County highway ,  Year Built: 1915,  Structure Length: 0. m,  Average Daily Traffic: 5,900 (year 2015),  Truck Traffic: 6%,  Features Intersected: OLD REDWOOD HWY,  Facility Carried by Structure: NCRRA/NWP RR
Minimum Vertical Clearance: 4.24m (13.91ft),  Kilometerpoint: 0.000,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 12.2m (40.0ft)

Discuss Windsor, California (CA) on our hugely popular California forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.