2006 National Fire Incident Reporting System Incidents:
  • Fire: 19
  • Hazardous Condition: 3

Incident types - McCammon

Incident types - Idaho

Location: Mccammon, McCammon, ID 83250
Fire Department: Pocatello City F.D., 408 Whitman, Pocatello, ID 83201,  ID: 05101,  Incident #: 10383,  Station: 1,  Shift/Platoon: B
Incident Type: Chemical spill or leak. Includes unstable, reactive, explosive material.
Alarm Time: 10/27/2006 20:41,  Arrival Time: 10/27/2006 21:00,  Last Unit Cleared Time: 10/27/2006 23:59
Alarms transmitted for the incident: 1
Actions taken:
  • Hazardous materials detection, monitoring, sampling, and analysis using a variety of detection instruments.
  • Investigate. Includes investigations done on arrival to determine the situation and postincident investigations; and collecting incident information for incident reporting purposes.
Location: Raymond, McCammon, ID 83246
Fire Department: Lava Hot Springs Fire Dept., Bannock, ID 83246,  ID: 05329,  Incident #: 95,  Station: 1
Incident Type: Grass fire. Includes fire confined to area characterized by grass ground cover, with little or no involvement of other ground fuels.
Alarm Time: 04/14/2006 15:50,  Arrival Time: 04/14/2006 16:16,  Controlled Time: 04/14/2006 17:05,  Last Unit Cleared Time: 04/14/2006 17:18
Action taken: Confine fire (wildland).
Location: Merrill Road, McCammon, ID 83250
Fire Department: Lava Hot Springs Fire Dept., Bannock, ID 83246,  ID: 05329,  Incident #: 101,  Station: 1
Incident Type: Brush or brush-and-grass mixture fire. Includes ground fuels lying on or immediately above the ground such as duff, roots, dead leaves, fine dead wood, and downed logs.
Alarm Time: 08/12/2006 14:45,  Arrival Time: 08/12/2006 15:15,  Controlled Time: 08/12/2006 19:30,  Last Unit Cleared Time: 08/12/2006 19:40
Actions taken:
  • Provide water. Includes tanker shuttle operations and pumping in a relay or from a water source. Excludes normal fire suppression operations.
  • Establish safe area. Includes isolating the area affected by denying entry to unprotected persons and establishing hazard control zones (hot, warm, cold).
  • Provide manpower. Includes providing manpower to assist rescue/ambulance units lift patients or providing manpower to assist police.
Location: East 12th Street, McCammon, ID 83250
Fire Department: McCammon Fire, 302 Center, McCammon, ID 83250,  ID: 05340,  Incident #: 1,  Station: 1
Incident Type: Building fire
Alarm Time: 01/09/2006 05:15,  Arrival Time: 01/09/2006 05:33,  Controlled Time: 01/09/2006 11:00,  Last Unit Cleared Time: 01/09/2006 13:45
Property Loss: $60000,  Contents Loss: $10000
Action taken: Extinguishment by fire service personnel.
Buildings Involved #: 1,  Acres Burned #: < 1,  On Site Materials: Personal & home products, other
Area of Origin: Attic: vacant, crawl space above top story, cupola,  Heat Source: Arcing,  Item First Ignited: Insulation within structural area
Cause of Ignition: Unintentional
  • Unspecified short-circuit arc
  • Trouble finding location
  • Difficult to ventilate
  • Water supply inadequate: public
Location: East Street, McCammon, ID 83250
Fire Department: McCammon Fire, 302 Center, McCammon, ID 83250,  ID: 05340,  Incident #: 2,  Station: 1
Incident Type: Building fire
Alarm Time: 01/15/2006 02:53,  Arrival Time: 01/15/2006 03:05,  Controlled Time: 01/15/2006 06:30,  Last Unit Cleared Time: 01/15/2006 07:08
Property Loss: $40000,  Contents Loss: $30000
Action taken: Extinguishment by fire service personnel.
Buildings Involved #: 1,  Acres Burned #: < 1
Area of Origin: Substructure area or space, crawl space, (Delayed reporting of fire)
Structure Type: Fixed portable or mobile structure,  Status: In normal use,  Stories: 1 Above,  Square Feet: 1350,  Stories with Damage: 1 Extreme
Location: Unspecified, McCammon, ID 83250
Fire Department: McCammon Fire, 302 Center, McCammon, ID 83250,  ID: 05340,  Incident #: 4,  Station: 1
Incident Type: Brush or brush-and-grass mixture fire. Includes ground fuels lying on or immediately above the ground such as duff, roots, dead leaves, fine dead wood, and downed logs.
Alarm Time: 04/14/2006 15:42,  Arrival Time: 04/14/2006 15:44,  Controlled Time: 04/14/2006 18:30,  Last Unit Cleared Time: 04/14/2006 18:33
Actions taken:
  • Contain fire (wildland).
  • Confine fire (wildland).
  • Control fire (wildland).
Area Type: Urban -wildland interface area,  Wildland Fire Cause: Misuse of fire,  Ignition Factors: High wind, Agriculture or land management burns,  Human Factors: Possibly impaired by alcohol,  Heat Source: Heat from other open flame or smoking materials,  Property Management Ownership: Tax paying,  Person Responsible for Fire: Identified person caused fire,  Gender: Male,  Age: 42.00
Total Acres Burned: 7,  Tax Paying: 100 %
Location: Old Hwy.91, McCammon, ID 83250
Fire Department: McCammon Fire, 302 Center, McCammon, ID 83250,  ID: 05340,  Incident #: 5,  Station: 1
Incident Type: Brush or brush-and-grass mixture fire. Includes ground fuels lying on or immediately above the ground such as duff, roots, dead leaves, fine dead wood, and downed logs.
Alarm Time: 04/22/2006 13:52,  Arrival Time: 04/22/2006 14:13,  Controlled Time: 04/22/2006 15:30,  Last Unit Cleared Time: 04/22/2006 15:34
Actions taken:
  • Contain fire (wildland).
  • Confine fire (wildland).
  • Control fire (wildland).
Area Type: Rural, including farms >50 acres,  Wildland Fire Cause: Debris, vegetation burn,  Ignition Factors: Agriculture or land management burns,  Heat Source: Heat from other open flame or smoking materials,  Person Responsible for Fire: Identified person caused fire,  Gender: Male,  Age: 35.00
Total Acres Burned: 0.2,  Undetermined: 100 %
Location: I-15, McCammon, ID 83250
Fire Department: McCammon Fire, 302 Center, McCammon, ID 83250,  ID: 05340,  Incident #: 8,  Station: 1
Incident Type: Brush or brush-and-grass mixture fire. Includes ground fuels lying on or immediately above the ground such as duff, roots, dead leaves, fine dead wood, and downed logs.
Alarm Time: 05/20/2006 18:05,  Arrival Time: 05/20/2006 18:12,  Controlled Time: 05/20/2006 18:45,  Last Unit Cleared Time: 05/20/2006 18:45
Actions taken:
  • Contain fire (wildland).
  • Confine fire (wildland).
  • Control fire (wildland).
Area Type: Rural, including farms >50 acres,  Ignition Factors: Natural condition, other
Total Acres Burned: 0.1
Location: Hwy 30 Highway, McCammon, ID 83250
Fire Department: McCammon Fire, 302 Center, McCammon, ID 83250,  ID: 05340,  Incident #: 15,  Station: 1
Incident Type: Brush or brush-and-grass mixture fire. Includes ground fuels lying on or immediately above the ground such as duff, roots, dead leaves, fine dead wood, and downed logs.
Alarm Time: 07/13/2006 17:23,  Arrival Time: 07/13/2006 17:45,  Controlled Time: 07/13/2006 18:05,  Last Unit Cleared Time: 07/13/2006 18:30
Actions taken:
  • Contain fire (wildland).
  • Confine fire (wildland).
  • Control fire (wildland).
Area Type: Rural, including farms >50 acres,  Wildland Fire Cause: Equipment,  Ignition Factors: Unspecified short-circuit arc,  Heat Source: Arcing,  Equipment Involved In Ignition: Transformer, distribution type
Total Acres Burned: 0.2
Location: Old Hwy.91, McCammon, ID 83250
Fire Department: McCammon Fire, 302 Center, McCammon, ID 83250,  ID: 05340,  Incident #: 19,  Station: 1
Incident Type: Grass fire. Includes fire confined to area characterized by grass ground cover, with little or no involvement of other ground fuels.
Alarm Time: 08/05/2006 14:16,  Arrival Time: 08/05/2006 14:26,  Controlled Time: 08/05/2006 15:28,  Last Unit Cleared Time: 08/05/2006 15:34
Contents Loss: $200
Actions taken:
  • Contain fire (wildland).
  • Confine fire (wildland).
  • Control fire (wildland).
Area Type: Rural, including farms >50 acres,  Wildland Fire Cause: Natural source,  Ignition Factors: Storm
Total Acres Burned: 2,  Tax Paying: 100 %
Location: Merrill Road Road, McCammon, ID 83250
Fire Department: McCammon Fire, 302 Center, McCammon, ID 83250,  ID: 05340,  Incident #: 21,  Station: 1
Incident Type: Brush or brush-and-grass mixture fire. Includes ground fuels lying on or immediately above the ground such as duff, roots, dead leaves, fine dead wood, and downed logs.
Alarm Time: 08/12/2006 14:29,  Arrival Time: 08/12/2006 14:41,  Controlled Time: 08/12/2006 19:26,  Last Unit Cleared Time: 08/12/2006 19:26
Actions taken:
  • Contain fire (wildland).
  • Confine fire (wildland).
  • Control fire (wildland).
Area Type: Rural, including farms >50 acres,  Wildland Fire Cause: Equipment,  Ignition Factors: Cutting, welding too close to combustible,  Heat Source: Spark, ember or flame from operating equipment
Total Acres Burned: 4
Location: Hwy 30 Highway, McCammon, ID 83250
Fire Department: McCammon Fire, 302 Center, McCammon, ID 83250,  ID: 05340,  Incident #: 22,  Station: 1
Incident Type: Grass fire. Includes fire confined to area characterized by grass ground cover, with little or no involvement of other ground fuels.
Alarm Time: 08/13/2006 14:02,  Arrival Time: 08/13/2006 14:08,  Controlled Time: 08/13/2006 14:15,  Last Unit Cleared Time: 08/13/2006 14:32
Action taken: Extinguishment by fire service personnel.
Area Type: Rural, including farms >50 acres,  Wildland Fire Cause: Debris, vegetation burn,  Ignition Factors: Heat source too close to combustibles.,  Heat Source: Hot ember or ash,  Property Management Ownership: Tax paying,  NFDRS Fuel Model at Origin: A: Annual Grasses.,  Person Responsible for Fire: Identified person caused fire,  Gender: Male,  Age: 75.00
Total Acres Burned: 0.2,  Tax Paying: 100 %
Location: I-15, McCammon, ID 83250
Fire Department: McCammon Fire, 302 Center, McCammon, ID 83250,  ID: 05340,  Incident #: 23,  Station: 1
Incident Type: Passenger vehicle fire. Includes any motorized passenger vehicle, other than a motor home (e.g., pickup trucks, sport utility vehicles, buses).
Alarm Time: 08/14/2006 17:44,  Arrival Time: 08/14/2006 17:57,  Controlled Time: 08/14/2006 17:58,  Last Unit Cleared Time: 08/14/2006 18:07
Property Value: $1000,  Property Loss: $1000
Action taken: Extinguishment by fire service personnel.
Acres Burned #: < 1
Area of Origin: Engine area, running gear, wheel area,  Heat Source: Radiated, conducted heat from operating equipment,  Item First Ignited: Flammable liquid/gas - in/from engine or burner
Cause of Ignition: Unintentional (Leak or break)
Mobile Property Involved: Involved in ignition and burned,  Type: Passenger car.,  Make: Ford,  Model: F250,  Year: 1991,  License Plate: 733UEM UT,  VIN No: 1FTHX26G1NKA52276
Location: 8th Street Street, McCammon, ID 83250
Fire Department: McCammon Fire, 302 Center, McCammon, ID 83250,  ID: 05340,  Incident #: 24,  Station: 1
Incident Type: Brush or brush-and-grass mixture fire. Includes ground fuels lying on or immediately above the ground such as duff, roots, dead leaves, fine dead wood, and downed logs.
Alarm Time: 08/15/2006 15:12,  Arrival Time: 08/15/2006 15:12,  Controlled Time: 08/15/2006 15:13,  Last Unit Cleared Time: 08/15/2006 17:00
Action taken: Extinguishment by fire service personnel.
Area Type: Rural/urban or suburban
Total Acres Burned: 0.5
Location: Unspecified, McCammon, ID 83250
Fire Department: McCammon Fire, 302 Center, McCammon, ID 83250,  ID: 05340,  Incident #: 26,  Station: 1
Incident Type: Brush or brush-and-grass mixture fire. Includes ground fuels lying on or immediately above the ground such as duff, roots, dead leaves, fine dead wood, and downed logs.
Alarm Time: 08/22/2006 04:30,  Arrival Time: 08/22/2006 04:43,  Controlled Time: 08/22/2006 08:00,  Last Unit Cleared Time: 08/22/2006 08:10
Actions taken:
  • Contain fire (wildland).
  • Confine fire (wildland).
  • Control fire (wildland).
Location: Unspecified, McCammon, ID 83250
Fire Department: McCammon Fire, 302 Center, McCammon, ID 83250,  ID: 05340,  Incident #: 29,  Station: 1
Incident Type: Grass fire. Includes fire confined to area characterized by grass ground cover, with little or no involvement of other ground fuels.
Alarm Time: 09/06/2006 18:15,  Arrival Time: 09/06/2006 18:24,  Controlled Time: 09/06/2006 19:16,  Last Unit Cleared Time: 09/06/2006 19:20
Actions taken:
  • Contain fire (wildland).
  • Confine fire (wildland).
  • Control fire (wildland).
Area Type: Rural, including farms >50 acres
Total Acres Burned: 0.1
Location: Old Hwy.91, McCammon, ID 83250
Fire Department: McCammon Fire, 302 Center, McCammon, ID 83250,  ID: 05340,  Incident #: 30,  Station: 1
Incident Type: Brush or brush-and-grass mixture fire. Includes ground fuels lying on or immediately above the ground such as duff, roots, dead leaves, fine dead wood, and downed logs.
Alarm Time: 09/06/2006 18:15,  Arrival Time: 09/06/2006 18:24,  Controlled Time: 09/06/2006 19:16,  Last Unit Cleared Time: 09/06/2006 19:20
Actions taken:
  • Contain fire (wildland).
  • Confine fire (wildland).
  • Control fire (wildland).
Area Type: Rural, including farms >50 acres
Total Acres Burned: 0.1
Location: Merrill Road Road, McCammon, ID 83250
Fire Department: McCammon Fire, 302 Center, McCammon, ID 83250,  ID: 05340,  Incident #: 32,  Station: 1
Incident Type: Oil or other combustible liquid spill (flash point at or above 100 degrees F at standard temperature and pressure (Class II or III)).
Alarm Time: 10/27/2006 18:15,  Arrival Time: 10/27/2006 18:20,  Controlled Time: 10/27/2006 22:48,  Last Unit Cleared Time: 10/27/2006 22:49
Hazardous Material Released: Paint from paint cans less than 55 gallons.
Action taken: Identification, analysis of hazardous materials.
Released From: Inside/On Structure,  Population Density: Rural - Scattered small communities and farms,  Area Affected: 3 Square Feet,  Area Evacuated: 150 Square Feet,  Cause of Release: Container or containment failure,  Disposition: Completed with fire service present,  Actions Taken: Isolate area & establish hazard control zones,  Provide apparatus,  ,  Factors Contributing To Release: Failure to control hazardous materials, other
Location: Dixon Rd. Road, McCammon, ID 83250
Fire Department: McCammon Fire, 302 Center, McCammon, ID 83250,  ID: 05340,  Incident #: 33,  Station: 1
Incident Type: Brush or brush-and-grass mixture fire. Includes ground fuels lying on or immediately above the ground such as duff, roots, dead leaves, fine dead wood, and downed logs.
Alarm Time: 10/31/2006 11:55,  Arrival Time: 10/31/2006 12:05,  Controlled Time: 10/31/2006 13:05,  Last Unit Cleared Time: 10/31/2006 13:07
Action taken: Extinguishment by fire service personnel.
Area Type: Rural, including farms >50 acres,  Wildland Fire Cause: Equipment,  Ignition Factors: Electrical failure, malfunction, other,  Heat Source: Arcing
Total Acres Burned: 0.2
Location: Dixon Rd., McCammon, ID 83250
Fire Department: McCammon Fire, 302 Center, McCammon, ID 83250,  ID: 05340,  Incident #: 34,  Station: 1
Incident Type: Building fire
Alarm Time: 12/05/2006 03:18,  Arrival Time: 12/05/2006 03:33,  Controlled Time: 12/05/2006 04:00,  Last Unit Cleared Time: 12/05/2006 04:55
Property Loss: $1000
Detector Alerted Occupants: Yes
Actions taken:
  • Extinguishment by fire service personnel.
  • Salvage and overhaul.
Buildings Involved #: 1,  Acres Burned #: < 1
Area of Origin: Ceiling & floor assembly, crawl space b/t stories,  Heat Source: Radiated, conducted heat from operating equipment,  Item First Ignited: Insulation within structural area
Cause of Ignition: Failure of equipment or heat source (Leak or break)
Structure Type: Enclosed building,  Status: In normal use,  Stories: 2 Above,  Square Feet: 1500,  Stories with Damage: 1 Minor
Location: Walker Creek Rd. Road, McCammon, ID 83250
Fire Department: McCammon Fire, 302 Center, McCammon, ID 83250,  ID: 05340,  Incident #: 36,  Station: 1
Incident Type: Fire
Alarm Time: 12/20/2006 12:03,  Arrival Time: 12/20/2006 12:15,  Controlled Time: 12/20/2006 12:40,  Last Unit Cleared Time: 12/20/2006 13:00
Contents Value: $200,  Contents Loss: $200
Action taken: Extinguishment by fire service personnel.
Acres Burned #: < 1
Area of Origin: Open area - outside,  Heat Source: Arcing,  Item First Ignited: Electrical wire, cable insulation
Cause of Ignition: Failure of equipment or heat source (Short circuit arc from defective, worn insulation)
Equipment Involved: Electrical wiring, other,  Power: Electrical, other,  Portability: Stationary
Location: Unspecified, McCammon, ID 83250
Fire Department: McCammon Fire, 302 Center, McCammon, ID 83250,  ID: 05340,  Incident #: 37,  Station: 1
Incident Type: Gasoline or other flammable liquid spill (flash point below 100 degrees F at standard temperature and pressure (Class I)).
Alarm Time: 12/20/2006 21:22,  Arrival Time: 12/20/2006 21:30,  Controlled Time: 12/20/2006 23:20,  Last Unit Cleared Time: 12/20/2006 23:29
Hazardous Material Released: Diesel fuel or fuel oil, vehicle fuel tank or portable storage container less than 55 gallons.
Actions taken:
  • Hazardous materials spill control and confinement. Includes confining or diking hazardous materials.
  • Hazardous materials leak control and containment. Includes actions taken to keep a material within its container.
Released From: Outside of structure,  Area Affected: 10 Square Feet,  Cause of Release: Container or containment failure,  Disposition: Completed by fire service only,  Actions Taken: Hazmat spill control and confinement,  Hazmat leak control and containment,  ,  Factors Contributing To Release: Collision, overturn, knockdown