Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Aventura, Florida (FL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 10Number of bridges
  • 525ft / 160mTotal length
  • $150,000Total costs
  • 127,946Total average daily traffic
  • 5,844Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Aventura
  • No street view available for this location

New bridges in Aventura, FL - historical statistics
  • New bridges - historical statistics
  • 71980-1989
  • 32000-2009
Average Bridge Daily Traffic in Aventura, FL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 75.0%Good
  • 25.0%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 75.0%Good
  • 25.0%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 75.0%Good
  • 25.0%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 66.7%Very good
  • 33.3%Good
Find on map >>   Show street view

Structure Number: 870606,  Location: 0.1M W OF A1A (Lat: 25.954269,  Lng: -80.126194),  Route carried "on" structure: State highway 856,  Year Built: 1983,  Status: Open,  Structure Length: 65.62m (215.29ft),  Average Daily Traffic: 16,750 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 29,061 (year 2042),  Design Load: HL 93,  Features Intersected: Intracoastal Waterway
Minimum Vertical Clearance: 5.24m (17.19ft),  Kilometerpoint: 1.807,  Lanes on structure: 3,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Navigation Control: Yes ( Vertical Clearance: 19.9m (65.3ft), Horizontal Clearance: 27.4m (89.9ft)),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 17,  Length of Maximum Span: 51.8m (169.9ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.66m (15.29ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Underwater Inspection Date: Febuary 2020,  Bridge Improvement Cost: $150,000,  Total Project Cost: $150,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 870607,  Location: 0.1M W OF A1A (Lat: 25.954097,  Lng: -80.126231),  Route carried "on" structure: State highway 856,  Year Built: 1983,  Status: Open,  Structure Length: 78.11m (256.27ft),  Average Daily Traffic: 16,750 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 29,061 (year 2042),  Design Load: HL 93,  Features Intersected: Intracoastal Waterway
Minimum Vertical Clearance: 5.99m (19.65ft),  Kilometerpoint: 1.807,  Lanes on structure: 3,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 16.7m (54.8ft),  Navigation Control: Yes ( Vertical Clearance: 19.9m (65.3ft), Horizontal Clearance: 27.4m (89.9ft)),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 21,  Length of Maximum Span: 51.8m (169.9ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 46.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 27.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Underwater Inspection Date: Febuary 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 870954,  Location: Bisc Blvd & Ives Dairy Rd (Lat: 25.963694,  Lng: -80.146944),  Route carried "on" structure: State highway 5,  Year Built: 2001,  Status: Open,  Structure Length: 13.93m (45.70ft),  Average Daily Traffic: 64,500 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 111,908 (year 2042),  Design Load: HL 93,  Features Intersected: FEC RR & West Dixie Hwy
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 39.517,  Lanes on structure: 8,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 33.6m (110.2ft),  Skew: 11 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 64.0m (210.0ft),  Curb-To-Curb Width: 31.2m (102.4ft),  Out-to-Out Width: 39.7m (130.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 47.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 8785,  Location: 0.1Mi W of Country Club E (Lat: 25.956000,  Lng: -80.128583),  Route carried "on" structure: City street ,  Year Built: 1981,  Status: Open,  Structure Length: 2.36m (7.74ft),  Average Daily Traffic: 4,250 (year 2019),  Truck Traffic: 1%,  Average Future Daily Traffic: 5,100 (year 2041),  Design Load: HS 20,  Features Intersected: Canal,  Facility Carried by Structure: Yacht Club Way
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.175,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 10.7m (35.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 24.4m (80.1ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Channel: Good,  Operating Rating: 44.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: March 2020,  Underwater Inspection Date: March 2020,  Other Special Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 870606,  Location: 0.1M W OF A1A (Lat: 25.954269,  Lng: -80.126194),  Route carried "under" structure: City street ,  Year Built: 1983,  Structure Length: 0. m,  Average Daily Traffic: 8,523 (year 2004),  Truck Traffic: 1%,  Features Intersected: Intracoastal Waterway,  Facility Carried by Structure: SR856 WB (870607)
Minimum Vertical Clearance: 5.00m (16.40ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 51.8m (169.9ft)

Find on map >>   Show street view

Structure Number: 870606,  Location: 0.1M W OF A1A (Lat: 25.954269,  Lng: -80.126194),  Route carried "under" structure: City street ,  Year Built: 1983,  Structure Length: 0. m,  Average Daily Traffic: 100 (year 2004),  Features Intersected: Intracoastal Waterway,  Facility Carried by Structure: SR856 WB (870607)
Minimum Vertical Clearance: 12.19m (39.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 51.8m (169.9ft)

Find on map >>   Show street view

Structure Number: 870607,  Location: 0.1M W OF A1A (Lat: 25.954097,  Lng: -80.126231),  Route carried "under" structure: City street ,  Year Built: 1983,  Structure Length: 0. m,  Average Daily Traffic: 8,523 (year 2004),  Truck Traffic: 1%,  Features Intersected: Intracoastal Waterway,  Facility Carried by Structure: SR856 EB (870606)
Minimum Vertical Clearance: 5.00m (16.40ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 51.8m (169.9ft)

Find on map >>   Show street view

Structure Number: 870607,  Location: 0.1M W OF A1A (Lat: 25.954097,  Lng: -80.126231),  Route carried "under" structure: City street ,  Year Built: 1983,  Structure Length: 0. m,  Average Daily Traffic: 100 (year 2004),  Features Intersected: Intracoastal Waterway,  Facility Carried by Structure: SR856 EB (870606)
Minimum Vertical Clearance: 12.19m (39.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 51.8m (169.9ft)

Find on map >>   Show street view

Structure Number: 870954,  Location: Bisc Blvd & Ives Dairy Rd (Lat: 25.963694,  Lng: -80.146944),  Route carried "under" structure: Alternate US ,  Year Built: 2001,  Structure Length: 0. m,  Average Daily Traffic: 5,000 (year 2004),  Truck Traffic: 5%,  Features Intersected: FEC RR & West Dixie Hwy,  Facility Carried by Structure: SR 5 & SR 856
Minimum Vertical Clearance: 6.73m (22.08ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 64.0m (210.0ft)

Find on map >>   Show street view

Structure Number: 870954,  Location: Bisc Blvd & Ives Dairy Rd (Lat: 25.963694,  Lng: -80.146944),  Route carried "under" structure: Alternate City street ,  Year Built: 2001,  Structure Length: 0. m,  Average Daily Traffic: 3,450 (year 2004),  Truck Traffic: 5%,  Features Intersected: FEC RR & West Dixie Hwy,  Facility Carried by Structure: SR 5 & SR 856
Minimum Vertical Clearance: 7.20m (23.62ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 64.0m (210.0ft)

Discuss Aventura, Florida (FL) on our hugely popular Florida forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.