Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Darien, Connecticut (CT)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 17Number of bridges
  • 82ft / 24.9mTotal length
  • 1,207,529Total average daily traffic
  • 142,482Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Darien
  • No street view available for this location

New bridges in Darien, CT - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 141950-1959
  • 11960-1969
  • 11980-1989
Reconstructed bridges in Darien, CT - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 41980-1989
  • 11990-1999
  • 22000-2009
Average Bridge Daily Traffic in Darien, CT
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 11.1%Very good
  • 44.4%Good
  • 44.4%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 44.4%Good
  • 11.1%Satisfactory
  • 44.4%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 44.4%Good
  • 55.6%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 33.3%Good
  • 50.0%Satisfactory
  • 16.7%Fair
Find on map >>   Show street view

Structure Number: 4,  Location: 0.2 MI S OF SERVICE AREA (Lat: 41.063419,  Lng: -73.508114),  Route carried "on" structure: Interstate 95,  Year Built: 1958,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 2.47m (8.10ft),  Average Daily Traffic: 146,000 (year 2017),  Truck Traffic: 14%,  Average Future Daily Traffic: 216,941 (year 2037),  Design Load: HS 20,  Features Intersected: BROOKSIDE DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.578,  Lanes on structure: 7,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 29.3m (96.1ft),  Skew: 34 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.6m (74.1ft),  Curb-To-Curb Width: 39.3m (128.9ft),  Out-to-Out Width: 42.3m (138.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 87.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 41,  Location: BETWEEN EXIT 9 AND 10 (Lat: 41.068269,  Lng: -73.499508),  Route carried "on" structure: City street ,  Year Built: 1958,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 5.88m (19.29ft),  Average Daily Traffic: 4,500 (year 2017),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,687 (year 2037),  Design Load: HL 93,  Features Intersected: INTERSTATE 95,  Facility Carried by Structure: HOLLOW TREE RDG RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.938,  Lanes on structure: 2,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 28.3m (92.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 16.1m (52.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 31.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 24.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 43,  Location: JCT OF US ROUTE 1 EXIT 11 (Lat: 41.072472,  Lng: -73.474983),  Route carried "on" structure: Interstate 95,  Year Built: 1958,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 3.93m (12.89ft),  Average Daily Traffic: 138,600 (year 2017),  Truck Traffic: 15%,  Average Future Daily Traffic: 205,946 (year 2037),  Design Load: H 20,  Features Intersected: US ROUTE 1
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.684,  Lanes on structure: 6,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 33.8m (110.9ft),  Skew: 35 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 36.6m (120.1ft),  Curb-To-Curb Width: 33.1m (108.6ft),  Out-to-Out Width: 36.2m (118.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 72.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 44,  Location: 0.4 MI S OF ROUTE 136 (Lat: 41.073839,  Lng: -73.469992),  Route carried "on" structure: Interstate 95,  Year Built: 1952,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 4.97m (16.31ft),  Average Daily Traffic: 148,600 (year 2017),  Truck Traffic: 9%,  Average Future Daily Traffic: 220,805 (year 2037),  Design Load: HS 20,  Features Intersected: KINGS HWY-GOODWIVES RV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.119,  Lanes on structure: 8,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 44.2m (145.0ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 41.1m (134.8ft),  Out-to-Out Width: 44.1m (144.7ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 36.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 28.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 45,  Location: JCT RT 136 EXIT 12 (Lat: 41.076656,  Lng: -73.465022),  Route carried "on" structure: Interstate 95,  Year Built: 1952,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 1.77m (5.81ft),  Average Daily Traffic: 138,700 (year 2017),  Truck Traffic: 9%,  Average Future Daily Traffic: 206,094 (year 2037),  Design Load: HS 20,  Features Intersected: ROUTE 136
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.682,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 33.5m (109.9ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.3m (53.5ft),  Curb-To-Curb Width: 33.5m (109.9ft),  Out-to-Out Width: 36.5m (119.8ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 69.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 53.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2395,  Location: BETWEEN EXITS 10 & 11 (Lat: 41.071592,  Lng: -73.481567),  Route carried "on" structure: Interstate 95,  Year Built: 1958,  Year Reconstructed: 1992,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 145,500 (year 2017),  Truck Traffic: 14%,  Average Future Daily Traffic: 216,198 (year 2037),  Design Load: H 20,  Features Intersected: STONY BROOK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.137,  Lanes on structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 44.2m (145.0ft),  Skew: 30 degrees,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 3847,  Location: WEST END OF DARIEN STA (Lat: 41.069192,  Lng: -73.499186),  Route carried "on" structure: City street ,  Year Built: 1900,  Year Reconstructed: 1992,  Status: Open,  Structure Length: 1.86m (6.10ft),  Average Daily Traffic: 4,500 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 6,687 (year 2040),  Design Load: HS 20,  Features Intersected: METRO-NORTH RAILROAD,  Facility Carried by Structure: HOLLOW TREE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.982,  Lanes on structure: 2,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.7m (58.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 28.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4143,  Location: 1.5 MI E OF ROUTE 106 (Lat: 41.082094,  Lng: -73.485575),  Route carried "on" structure: City street ,  Year Built: 1950,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 6,732 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 10,003 (year 2041),  Features Intersected: STONY BROOK,  Facility Carried by Structure: MIDDLESEX ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 42.6 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4144,  Location: 0.1 MI NO OF SEDGWICK AVE (Lat: 41.079486,  Lng: -73.465547),  Route carried "on" structure: City street ,  Year Built: 1956,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 5,740 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 8,529 (year 2041),  Features Intersected: GOODWIVES RIVER,  Facility Carried by Structure: OLD KINGS HWY NORT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5385,  Location: 0.7 MI SOUTH OF I-95 UP (Lat: 41.063569,  Lng: -73.481633),  Route carried "on" structure: US 1,  Year Built: 1986,  Status: Open,  Structure Length: 1.05m (3.44ft),  Average Daily Traffic: 11,800 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 17,534 (year 2040),  Design Load: HS 20,  Features Intersected: STONEY BROOK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.834,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 3.7m (12.1ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 14.4m (47.2ft),  Out-to-Out Width: 20.0m (65.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 73.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 6114,  Location: 0.2 MI W OF RAYMOND ST (Lat: 41.077547,  Lng: -73.454003),  Route carried "on" structure: City street ,  Year Built: 1966,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 57 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 85 (year 2041),  Features Intersected: TOKENEKE BROOK,  Facility Carried by Structure: LITTLE BROOK ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 11.7m (38.4ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 42.6 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 41,  Location: BETWEEN EXIT 9 AND 10 (Lat: 41.068269,  Lng: -73.499508),  Route carried "under" structure: Interstate 95,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 146,000 (year 2017),  Truck Traffic: 14%,  Features Intersected: INTERSTATE 95,  Facility Carried by Structure: HOLLOW TREE RDG RD
Minimum Vertical Clearance: 5.79m (19.00ft),  Kilometerpoint: 16.528,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.3m (92.8ft)

Find on map >>   Show street view

Structure Number: 42,  Location: AT EXIT 10 (Lat: 41.068222,  Lng: -73.490558),  Route carried "under" structure: Interstate 95,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 139,100 (year 2017),  Truck Traffic: 14%,  Features Intersected: INTERSTATE 95,  Facility Carried by Structure: NOROTON AVENUE
Minimum Vertical Clearance: 7.47m (24.51ft),  Kilometerpoint: 17.300,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.3m (83.0ft)

Find on map >>   Show street view

Structure Number: 43,  Location: JCT OF US ROUTE 1 EXIT 11 (Lat: 41.072472,  Lng: -73.474983),  Route carried "under" structure: US 1,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 12,900 (year 2017),  Truck Traffic: 5%,  Features Intersected: US ROUTE 1,  Facility Carried by Structure: INTERSTATE-95
Minimum Vertical Clearance: 4.55m (14.93ft),  Kilometerpoint: 17.976,  Lanes on structure: 6,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.6m (120.1ft)

Find on map >>   Show street view

Structure Number: 45,  Location: JCT RT 136 EXIT 12 (Lat: 41.076656,  Lng: -73.465022),  Route carried "under" structure: State highway 136,  Year Built: 1952,  Structure Length: 0. m,  Average Daily Traffic: 11,900 (year 2017),  Truck Traffic: 2%,  Features Intersected: ROUTE 136,  Facility Carried by Structure: INTERSTATE-95
Minimum Vertical Clearance: 4.65m (15.26ft),  Kilometerpoint: 0.467,  Lanes on structure: 6,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.3m (53.5ft)

Find on map >>   Show street view

Structure Number: 47,  Location: 0.5 MI WEST NORWALK TL (Lat: 41.084583,  Lng: -73.459783),  Route carried "under" structure: Interstate 95,  Year Built: 1952,  Structure Length: 0. m,  Average Daily Traffic: 138,700 (year 2018),  Truck Traffic: 9%,  Features Intersected: INTERSTATE-95,  Facility Carried by Structure: OLD KINGS HWY N #1
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 20.664,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.0m (59.1ft)

Find on map >>   Show street view

Structure Number: 48,  Location: I-95 NB EXIT NO. 13 (Lat: 41.089639,  Lng: -73.453689),  Route carried "under" structure: Ramp Interstate 95,  Year Built: 1956,  Structure Length: 0. m,  Average Daily Traffic: 8,200 (year 2017),  Truck Traffic: 2%,  Features Intersected: I-95 RMP 047/FIVE MI RIV
Minimum Vertical Clearance: 4.47m (14.67ft),  Kilometerpoint: 0.322,  Lanes on structure: 6,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.0m (82.0ft)

Discuss Darien, Connecticut (CT) on our hugely popular Connecticut forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.