Bridge Statistics for Euclid, Ohio (OH)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 24Number of bridges
  • 279ft / 85.3mTotal length
  • $1,000,000Total costs
  • 636,288Total average daily traffic
  • 24,886Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Euclid
  • No street view available for this location

New bridges in Euclid, OH - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 211960-1969
  • 22000-2009
Reconstructed bridges in Euclid, OH - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 31980-1989
  • 01990-1999
  • 02000-2009
  • 02010-2019
  • 42020-2022
Average Bridge Daily Traffic in Euclid, OH
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 30.8%Excellent
  • 23.1%Very good
  • 46.2%Good
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 28.6%Excellent
  • 7.1%Very good
  • 64.3%Good
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 14.3%Very good
  • 50.0%Good
  • 35.7%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 40.0%Good
  • 40.0%Fair
  • 20.0%Serious
Find on map >>   Show street view

Structure Number: 1801082,  Location: APPROX 500FT E DILLE RD (Lat: 41.568281,  Lng: -81.535950),  Route carried "on" structure: US 6,  Year Built: 1902,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 22,823 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 31,678 (year 2035),  Design Load: H 15,  Features Intersected: EUCLID CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 40.829,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 17.3m (56.8ft),  Out-to-Out Width: 29.4m (96.5ft)

Condition: Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.10m (20.01ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $500,000,  Roadway Improvement Cost: $500,000,  Total Project Cost: $1,000,000,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 1808915,  Location: 1.56 MI W OF JCT SR175 (Lat: 41.587261,  Lng: -81.526881),  Route carried "on" structure: Interstate 90,  Year Built: 1963,  Year Reconstructed: 1993,  Status: Open,  Structure Length: 7.04m (23.10ft),  Average Daily Traffic: 109,438 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 151,900 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: CR 44 (E 222 ST)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 44.321,  Lanes on structure: 8,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 50.0m (164.0ft),  Skew: 33 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 50.0m (164.0ft),  Out-to-Out Width: 50.6m (166.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1808974,  Location: .70 MI W OF JCT SR175 (Lat: 41.594919,  Lng: -81.513681),  Route carried "on" structure: Interstate 90,  Year Built: 1963,  Year Reconstructed: 1993,  Status: Open,  Structure Length: 6.37m (20.90ft),  Average Daily Traffic: 113,245 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 157,184 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: CR 116 (BABBITT RD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 45.705,  Lanes on structure: 8,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 42.7m (140.1ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.9m (85.0ft),  Curb-To-Curb Width: 42.7m (140.1ft),  Out-to-Out Width: 43.3m (142.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1809008,  Location: IR90 AND SR175 JCT (Lat: 41.601300,  Lng: -81.503039),  Route carried "on" structure: Interstate 90,  Year Built: 1963,  Year Reconstructed: 1993,  Status: Open,  Structure Length: 8.11m (26.61ft),  Average Daily Traffic: 115,513 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 160,332 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: SR 175 (1446) E 260 ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 46.832,  Lanes on structure: 8,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 42.7m (140.1ft),  Skew: 13 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 18.9m (62.0ft),  Curb-To-Curb Width: 42.7m (140.1ft),  Out-to-Out Width: 43.3m (142.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1809164,  Location: 4 MI W OF SR 640 (Lat: 41.605550,  Lng: -81.494319),  Route carried "on" structure: Interstate 90,  Year Built: 2006,  Status: Open,  Structure Length: 7.22m (23.69ft),  Average Daily Traffic: 15,678 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 21,761 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: SR 2 EB & SR-2 RAMP ES
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 47.572,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 30.6m (100.4ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 71.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 180918,  Location: 4.5 MI W SR 640 (Lat: 41.605861,  Lng: -81.494531),  Route carried "on" structure: Ramp Interstate 90,  Year Built: 1963,  Status: Open,  Structure Length: 5.40m (17.72ft),  Average Daily Traffic: 12,173 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 16,896 (year 2036),  Design Load: HS 20+Mod,  Features Intersected: SR 2 EB
Minimum Vertical Clearance: 4.60m (15.09ft),  Kilometerpoint: 0.269,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 180921,  Location: .59 MI E OF JCT SR175 (Lat: 41.603989,  Lng: -81.492281),  Route carried "on" structure: Interstate 90,  Year Built: 1963,  Status: Open,  Structure Length: 8.84m (29.00ft),  Average Daily Traffic: 15,678 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 21,761 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: LAKELAND BLVD & CSX RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 47.781,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.0m (68.9ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.3m (92.8ft),  Curb-To-Curb Width: 21.0m (68.9ft),  Out-to-Out Width: 21.6m (70.9ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 38.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 1809245,  Location: .59 MI E OF JCT SR 175 (Lat: 41.603761,  Lng: -81.492861),  Route carried "on" structure: Interstate 90,  Year Built: 1963,  Status: Open,  Structure Length: 8.66m (28.41ft),  Average Daily Traffic: 15,678 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 21,761 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: LAKELAND BLVD & CSX RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 47.781,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.5m (77.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.0m (91.9ft),  Curb-To-Curb Width: 23.6m (77.4ft),  Out-to-Out Width: 24.2m (79.4ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 19.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 1809334,  Location: .79 MI E OF JCT SR175 (Lat: 41.602000,  Lng: -81.490289),  Route carried "on" structure: Interstate 90,  Year Built: 1963,  Status: Open,  Structure Length: 4.72m (15.49ft),  Average Daily Traffic: 15,678 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 21,761 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: NSC RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 48.103,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 17.2m (56.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 1809369,  Location: .79 MI E OF JCT SR 175 (Lat: 41.601861,  Lng: -81.490531),  Route carried "on" structure: Interstate 90,  Year Built: 1963,  Status: Open,  Structure Length: 4.72m (15.49ft),  Average Daily Traffic: 15,678 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 21,761 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: NSC RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 48.103,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 1830325,  Location: 590 FT SE OF EUCLID AVE (Lat: 41.566161,  Lng: -81.535339),  Route carried "on" structure: County highway 47,  Year Built: 1968,  Year Reconstructed: 2020,  Status: Open,  Structure Length: 4.05m (13.29ft),  Average Daily Traffic: 10,520 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 14,602 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: EUCLID CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.209,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 21.5m (70.5ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Satisfactory,  Channel: Serious,  Operating Rating: 66.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1830333,  Location: 1592 FT SE OF EUCLID AVE (Lat: 41.564439,  Lng: -81.532781),  Route carried "on" structure: County highway 47,  Year Built: 1968,  Year Reconstructed: 2020,  Status: Open,  Structure Length: 4.59m (15.06ft),  Average Daily Traffic: 13,500 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 14,602 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: EUCLID CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.499,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.3m (56.8ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 16.7m (54.8ft),  Out-to-Out Width: 22.3m (73.2ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 69.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1830341,  Location: 2052 FT SE OF EUCLID AVE (Lat: 41.561489,  Lng: -81.530219),  Route carried "on" structure: County highway 47,  Year Built: 1968,  Year Reconstructed: 2020,  Status: Open,  Structure Length: 6.18m (20.28ft),  Average Daily Traffic: 10,520 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 14,602 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: EUCLID CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.869,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.2m (76.1ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 21.5m (70.5ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1830368,  Location: 3305 FT SE OF EUCLID AVE (Lat: 41.560400,  Lng: -81.529469),  Route carried "on" structure: County highway 47,  Year Built: 1968,  Year Reconstructed: 2020,  Status: Open,  Structure Length: 7.84m (25.72ft),  Average Daily Traffic: 10,520 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 14,602 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: EUCLID CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.030,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 29.7m (97.4ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 21.5m (70.5ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Very good,  Channel: Good,  Operating Rating: 57.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1808915,  Location: 1.56 MI W OF JCT SR175 (Lat: 41.587261,  Lng: -81.526881),  Route carried "under" structure: Ramp State highway 18513,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 908 (year 2019),  Truck Traffic: 2%,  Features Intersected: IR-90,  Facility Carried by Structure: IR90 OVER E-222ND
Minimum Vertical Clearance: 4.55m (14.93ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.3m (60.0ft)

Find on map >>   Show street view

Structure Number: 1808915,  Location: 1.56 MI W OF JCT SR175 (Lat: 41.587261,  Lng: -81.526881),  Route carried "under" structure: County highway C0044,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 9,170 (year 2015),  Truck Traffic: 7%,  Features Intersected: IR 90,  Facility Carried by Structure: IR90 OVER E-222ND
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.241,  Lanes on structure: 8,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.3m (60.0ft)

Find on map >>   Show street view

Structure Number: 1808915,  Location: 1.56 MI W OF JCT SR175 (Lat: 41.587261,  Lng: -81.526881),  Route carried "under" structure: Ramp State highway 18512,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 659 (year 2019),  Truck Traffic: 2%,  Features Intersected: IR-90,  Facility Carried by Structure: IR90 OVER E-222ND
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.3m (60.0ft)

Find on map >>   Show street view

Structure Number: 1808974,  Location: .70 MI W OF JCT SR175 (Lat: 41.594919,  Lng: -81.513681),  Route carried "under" structure: Ramp State highway 18518,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 595 (year 2019),  Truck Traffic: 2%,  Features Intersected: IR-90,  Facility Carried by Structure: IR 90
Minimum Vertical Clearance: 4.83m (15.85ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.9m (85.0ft)

Find on map >>   Show street view

Structure Number: 1808974,  Location: .70 MI W OF JCT SR175 (Lat: 41.594919,  Lng: -81.513681),  Route carried "under" structure: County highway 116,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 6,912 (year 2015),  Truck Traffic: 5%,  Features Intersected: I-90,  Facility Carried by Structure: IR 90
Minimum Vertical Clearance: 4.65m (15.26ft),  Kilometerpoint: 1.271,  Lanes on structure: 8,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.9m (85.0ft)

Find on map >>   Show street view

Structure Number: 1808974,  Location: .70 MI W OF JCT SR175 (Lat: 41.594919,  Lng: -81.513681),  Route carried "under" structure: Ramp State highway 18519,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 2,996 (year 2019),  Truck Traffic: 1%,  Features Intersected: IR-90,  Facility Carried by Structure: IR 90
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.9m (85.0ft)

Find on map >>   Show street view

Structure Number: 1809008,  Location: IR90 AND SR175 JCT (Lat: 41.601300,  Lng: -81.503039),  Route carried "under" structure: State highway 175,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 15,315 (year 2019),  Truck Traffic: 2%,  Features Intersected: I-90,  Facility Carried by Structure: IR 90 OVER E. 260T
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 23.271,  Lanes on structure: 8,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.9m (62.0ft)

Find on map >>   Show street view

Structure Number: 1809008,  Location: IR90 AND SR175 JCT (Lat: 41.601300,  Lng: -81.503039),  Route carried "under" structure: Ramp State highway 18524,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 2,077 (year 2019),  Truck Traffic: 1%,  Features Intersected: IR-90,  Facility Carried by Structure: IR 90 OVER E. 260T
Minimum Vertical Clearance: 4.52m (14.83ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.9m (62.0ft)

Find on map >>   Show street view

Structure Number: 1809164,  Location: 4 MI W OF SR 640 (Lat: 41.605550,  Lng: -81.494319),  Route carried "under" structure: Ramp State highway 2,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 71,420 (year 2010),  Truck Traffic: 4%,  Features Intersected: IR-90WB UP, SR-2 DOWN,  Facility Carried by Structure: IR 90 WB
Minimum Vertical Clearance: 4.60m (15.09ft),  Kilometerpoint: 45.834,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.6m (100.4ft)

Find on map >>   Show street view

Structure Number: 180918,  Location: 4.5 MI W SR 640 (Lat: 41.605861,  Lng: -81.494531),  Route carried "under" structure: State highway 2,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 29,594 (year 2016),  Truck Traffic: 5%,  Features Intersected: RMP TO EB IR90 FROM SR2
Minimum Vertical Clearance: 4.52m (14.83ft),  Kilometerpoint: 45.853,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)