Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Lakeville, Minnesota (MN)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 42Number of bridges
  • 305ft / 93.3mTotal length
  • $2,000Total costs
  • 805,704Total average daily traffic
  • 62,266Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Lakeville
  • No street view available for this location

New bridges in Lakeville, MN - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 11940-1949
  • 151960-1969
  • 11970-1979
  • 21980-1989
  • 111990-1999
  • 92000-2009
  • 22010-2019
Average Bridge Daily Traffic in Lakeville, MN
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 6.3%Very good
  • 56.3%Good
  • 25.0%Satisfactory
  • 12.5%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 12.5%Very good
  • 37.5%Good
  • 31.3%Satisfactory
  • 18.8%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 18.8%Very good
  • 25.0%Good
  • 25.0%Satisfactory
  • 31.3%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 25.0%Very good
  • 45.0%Good
  • 20.0%Satisfactory
  • 10.0%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Very good
  • 25.0%Good
  • 25.0%Satisfactory
Find on map >>   Show street view

Structure Number: 19531,  Location: 1.6 MI S OF JCT 35 E;W (Lat: 44.714506,  Lng: -93.283569),  Route carried "on" structure: County highway 46,  Year Built: 1995,  Status: Open,  Structure Length: 7.35m (24.11ft),  Average Daily Traffic: 36,500 (year 2016),  Average Future Daily Traffic: 36,500 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: I 35
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 27.4m (89.9ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.5m (119.8ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 21.9m (71.9ft),  Out-to-Out Width: 35.1m (115.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 69.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 19538,  Location: 0.25 MI W OF JCT OF HOLY (Lat: 44.657867,  Lng: -93.247108),  Route carried "on" structure: City street 151,  Year Built: 1999,  Status: Open,  Structure Length: 1.51m (4.95ft),  Average Daily Traffic: 2,100 (year 2016),  Average Future Daily Traffic: 2,100 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: N BR SOUTH CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.7m (44.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 19.1m (62.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 59.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 19553,  Location: 0.1 MI E OF JCT CSAH 23 (Lat: 44.565569,  Lng: -93.204881),  Route carried "on" structure: County highway 102,  Year Built: 2004,  Status: Open,  Structure Length: 4.44m (14.57ft),  Average Daily Traffic: 60 (year 2003),  Average Future Daily Traffic: 60 (year 2029),  Design Load: HS 25 or greater,  Features Intersected: CP RAIL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.4m (57.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 82.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 50.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.62m (5.31ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Bridge Improvement Cost: $556,000,000,  Roadway Improvement Cost: $1,000,  Total Project Cost: $1,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 19565,  Location: 1100 FT E OF GERDINE PATH (Lat: 44.705383,  Lng: -93.208289),  Route carried "on" structure: City street 110,  Year Built: 2012,  Status: Open,  Structure Length: 0.96m (3.15ft),  Average Daily Traffic: 200 (year 2012),  Average Future Daily Traffic: 200 (year 2029),  Design Load: HL 93,  Features Intersected: NORTH CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 67.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 19803,  Location: 2.1 MI S OF JCT TH 35 E (Lat: 44.694778,  Lng: -93.290122),  Route carried "on" structure: Interstate 35,  Year Built: 1992,  Status: Open,  Structure Length: 5.28m (17.32ft),  Average Daily Traffic: 40,000 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 42,500 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: CP RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.1m (62.7ft),  Curb-To-Curb Width: 16.4m (53.8ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 77.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 19805,  Location: 2.1 MI S OF JCT TH 35 E (Lat: 44.694469,  Lng: -93.290017),  Route carried "on" structure: Interstate 35,  Year Built: 1965,  Year Reconstructed: 1992,  Status: Open,  Structure Length: 5.28m (17.32ft),  Average Daily Traffic: 40,000 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 42,500 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: CP RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.1m (62.7ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 43.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 19807,  Location: 2.8 MI S OF JCT TH 35 E (Lat: 44.697844,  Lng: -93.288375),  Route carried "on" structure: Interstate 35,  Year Built: 1965,  Status: Open,  Structure Length: 4.69m (15.39ft),  Average Daily Traffic: 42,500 (year 2017),  Truck Traffic: 9%,  Average Future Daily Traffic: 42,500 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: CSAH 50
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.2m (56.4ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 50.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 19808,  Location: 2.8 MI S OF JCT TH 35 E (Lat: 44.697689,  Lng: -93.288186),  Route carried "on" structure: Interstate 35,  Year Built: 1965,  Status: Open,  Structure Length: 4.47m (14.67ft),  Average Daily Traffic: 40,000 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 42,500 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: CSAH 50
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.2m (53.1ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 54.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.65m (5.41ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Bridge Improvement Cost: $982,000,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Other
Find on map >>   Show street view

Structure Number: 19841,  Location: 5.0 MI S OF JCT TH 35 E (Lat: 44.666917,  Lng: -93.294083),  Route carried "on" structure: City street 24,  Year Built: 1965,  Status: Open,  Structure Length: 6.51m (21.36ft),  Average Daily Traffic: 675 (year 1974),  Average Future Daily Traffic: 675 (year 2029),  Design Load: H 20,  Features Intersected: I 35
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.4m (66.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 40.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 19843,  Location: 6.0 MI S OF JCT TH 35 E (Lat: 44.652592,  Lng: -93.294975),  Route carried "on" structure: Interstate 35,  Year Built: 1965,  Status: Open,  Structure Length: 6.87m (22.54ft),  Average Daily Traffic: 35,000 (year 2017),  Truck Traffic: 13%,  Average Future Daily Traffic: 35,000 (year 2039),  Design Load: HS 20,  Features Intersected: CR 64 (205TH ST)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.9m (65.3ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 42.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 19844,  Location: 6.0 MI S OF JCT TH 35 E (Lat: 44.652542,  Lng: -93.294633),  Route carried "on" structure: Interstate 35,  Year Built: 1965,  Status: Open,  Structure Length: 6.87m (22.54ft),  Average Daily Traffic: 33,500 (year 2019),  Truck Traffic: 10%,  Average Future Daily Traffic: 35,000 (year 2039),  Design Load: HS 20,  Features Intersected: CR 64 (205TH ST)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.9m (65.3ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 42.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 19847,  Location: 4.6 MI S OF JCT TH 35 E (Lat: 44.672992,  Lng: -93.294206),  Route carried "on" structure: Interstate 35,  Year Built: 1965,  Status: Open,  Structure Length: 2.30m (7.55ft),  Average Daily Traffic: 33,500 (year 2019),  Truck Traffic: 13%,  Average Future Daily Traffic: 35,000 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: LAKE MARION
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.7m (25.3ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Fair,  Operating Rating: 86.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: April 2021,  Underwater Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 19848,  Location: 4.6 MI S OF JCT TH 35 E (Lat: 44.672989,  Lng: -93.293883),  Route carried "on" structure: Interstate 35,  Year Built: 1965,  Status: Open,  Structure Length: 2.32m (7.61ft),  Average Daily Traffic: 33,500 (year 2019),  Truck Traffic: 10%,  Average Future Daily Traffic: 35,000 (year 2039),  Design Load: HS 20,  Features Intersected: LAKE MARION
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.7m (25.3ft),  Curb-To-Curb Width: 11.7m (38.4ft),  Out-to-Out Width: 12.7m (41.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 99.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 76.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.85m (2.79ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: April 2021,  Underwater Inspection Date: August 2021,  Bridge Improvement Cost: $499,000,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1985,  Location: 6.5 MI S OF JCT TH 35 E (Lat: 44.645256,  Lng: -93.296106),  Route carried "on" structure: County highway 70,  Year Built: 2009,  Status: Open,  Structure Length: 7.76m (25.46ft),  Average Daily Traffic: 20,500 (year 2017),  Average Future Daily Traffic: 20,500 (year 2039),  Design Load: HL 93,  Features Intersected: I 35
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 37.2m (122.0ft),  Curb or Sidewalk Widths: Left: 3.7m (12.1ft),  Right: 3.7m (12.1ft),  Curb-To-Curb Width: 23.2m (76.1ft),  Out-to-Out Width: 42.7m (140.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 86.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 19903,  Location: 4.0 MI S OF JCT TH 3 (Lat: 44.681294,  Lng: -93.293608),  Route carried "on" structure: Interstate 35,  Year Built: 2004,  Status: Open,  Structure Length: 5.99m (19.65ft),  Average Daily Traffic: 35,000 (year 2017),  Truck Traffic: 13%,  Average Future Daily Traffic: 35,000 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: 185th ST W(CSAH 60)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 32.9m (107.9ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 67.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.01m (6.59ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Bridge Improvement Cost: $970,000,000,  Roadway Improvement Cost: $1,000,  Total Project Cost: $1,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 19J02,  Location: 0.3 MI W OF JCT CSAH 9 (Lat: 44.594592,  Lng: -93.272750),  Route carried "on" structure: County highway 100,  Year Built: 1995,  Status: Open,  Structure Length: 0.90m (2.95ft),  Average Daily Traffic: 120 (year 1996),  Truck Traffic: 6%,  Average Future Daily Traffic: 120 (year 2029),  Design Load: HS 25 or greater,  Features Intersected: VERMILLION RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 58.8 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020
Find on map >>   Show street view

Structure Number: 19J05,  Location: 0.2 MI S OF JCT CSAH 50 (Lat: 44.641553,  Lng: -93.227683),  Route carried "on" structure: City street 103,  Year Built: 1994,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 4,000 (year 2017),  Average Future Daily Traffic: 4,000 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: STREAM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 58.8 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2019
Find on map >>   Show street view

Structure Number: 19J11,  Location: 0.5 MI W OF JCT CSAH 23 (Lat: 44.644419,  Lng: -93.227647),  Route carried "on" structure: City street 140,  Year Built: 1994,  Status: Open,  Structure Length: 1.24m (4.07ft),  Average Daily Traffic: 7,249 (year 2008),  Truck Traffic: 4%,  Average Future Daily Traffic: 8,300 (year 2029),  Design Load: HS 25 or greater,  Features Intersected: N BRANCH VERMILLION RIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Skew: 5 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.1m (16.7ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 58.8 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2019
Find on map >>   Show street view

Structure Number: 19J13,  Location: 0.4 MI S OF JCT CR 58 (Lat: 44.696372,  Lng: -93.176536),  Route carried "on" structure: County highway 31,  Year Built: 1998,  Status: Open,  Structure Length: 1.17m (3.84ft),  Average Daily Traffic: 25,500 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 27,000 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: NORTH CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.1m (10.2ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 58.8 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: 19J19,  Location: 1.0 MI E OF JCT CSAH 9 (Lat: 44.587222,  Lng: -93.250800),  Route carried "on" structure: County highway 80,  Year Built: 2000,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 1,850 (year 2016),  Average Future Daily Traffic: 1,850 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: STREAM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.8m (9.2ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 58.8 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020
Find on map >>   Show street view

Structure Number: 19J25,  Location: 0.7 mi S of jct CSAH 23 (Lat: 44.632028,  Lng: -93.217689),  Route carried "on" structure: County highway 23,  Year Built: 2000,  Status: Open,  Structure Length: 0.78m (2.56ft),  Average Daily Traffic: 8,000 (year 2017),  Average Future Daily Traffic: 8,000 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: Trout Stream
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 58.8 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020
Find on map >>   Show street view

Structure Number: 19J26,  Location: 0.2 mi S of jct CSAH 50 (Lat: 44.639489,  Lng: -93.217592),  Route carried "on" structure: County highway 23,  Year Built: 2000,  Status: Open,  Structure Length: 1.23m (4.04ft),  Average Daily Traffic: 12,400 (year 2016),  Average Future Daily Traffic: 12,400 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: Trout Stream
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 21 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.1m (10.2ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 58.8 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020
Find on map >>   Show street view

Structure Number: 19J31,  Location: 100 SO OF JCT 167TH ST (Lat: 44.706467,  Lng: -93.212428),  Route carried "on" structure: City street 124,  Year Built: 1999,  Status: Open,  Structure Length: 0.71m (2.33ft),  Average Daily Traffic: 1,300 (year 2015),  Average Future Daily Traffic: 1,300 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: STREAM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.8m (9.2ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 68.6 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 19J32,  Location: 0.25 MI S OF 170TH ST W (Lat: 44.699436,  Lng: -93.192622),  Route carried "on" structure: City street 606,  Year Built: 1990,  Status: Open,  Structure Length: 1.05m (3.44ft),  Average Daily Traffic: 1,250 (year 2015),  Average Future Daily Traffic: 1,250 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: NORTH CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.2m (13.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 68.6 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2019
Find on map >>   Show street view

Structure Number: 19J61,  Location: 1.2 MI N OF JCT CSAH 80 (Lat: 44.603406,  Lng: -93.263717),  Route carried "on" structure: County highway 9,  Year Built: 2014,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 3,700 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,700 (year 2039),  Design Load: HL 93,  Features Intersected: VERMILLION RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.5m (11.5ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020
Find on map >>   Show street view

Structure Number: 6556,  Location: 0.62 MI S OF JCT CSAH 60 (Lat: 44.672944,  Lng: -93.293489),  Route carried "on" structure: City street 118,  Year Built: 1947,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 6,300 (year 2015),  Average Future Daily Traffic: 6,300 (year 2039),  Features Intersected: LAKE MARIO
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 29.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: August 2021,  Underwater Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: 70805,  Location: 10.7 MI N OF JCT TH 19 (Lat: 44.623572,  Lng: -93.298233),  Route carried "on" structure: County highway 29,  Year Built: 1964,  Status: Open,  Structure Length: 6.37m (20.90ft),  Average Daily Traffic: 2,250 (year 2017),  Average Future Daily Traffic: 2,250 (year 2039),  Design Load: H 20,  Features Intersected: I 35
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.5m (67.3ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 68.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 96445,  Location: 0.8 MI E OF JCT CSAH 9 (Lat: 44.608878,  Lng: -93.247214),  Route carried "on" structure: County highway 94,  Year Built: 1988,  Status: Open,  Structure Length: 0.89m (2.92ft),  Average Daily Traffic: 115 (year 1996),  Truck Traffic: 4%,  Average Future Daily Traffic: 115 (year 2029),  Design Load: HS 20,  Features Intersected: VERMILLION RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 58.8 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020
Find on map >>   Show street view

Structure Number: 96535,  Location: 0.5 MI S OF 225TH ST (Lat: 44.616161,  Lng: -93.228119),  Route carried "on" structure: County highway 72,  Year Built: 1988,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 50 (year 1996),  Average Future Daily Traffic: 50 (year 2029),  Design Load: HS 20,  Features Intersected: VERMILLION RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.2m (13.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 58.8 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020
Find on map >>   Show street view

Structure Number: 97247,  Location: 1.7 MI N OF JCT CSAH 80 (Lat: 44.611667,  Lng: -93.238333),  Route carried "on" structure: County highway 1214,  Year Built: 1995,  Status: Open,  Structure Length: 0.87m (2.85ft),  Average Daily Traffic: 185 (year 1996),  Truck Traffic: 6%,  Average Future Daily Traffic: 185 (year 2029),  Design Load: HS 20,  Features Intersected: VERMILLION RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.5m (11.5ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 53.9 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Allowable Stress Design (ASD) reported in metric tons,  Inventory Rating: 35.9 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Allowable Stress Design (ASD) reported in metric tons,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020
Find on map >>   Show street view

Structure Number: L3173,  Location: 0.6 MI N OF JCT CSAH 78 (Lat: 44.618617,  Lng: -93.217911),  Route carried "on" structure: County highway 23,  Year Built: 1923,  Status: Open,  Structure Length: 0.69m (2.26ft),  Average Daily Traffic: 5,800 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,800 (year 2039),  Features Intersected: VERMILLION RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 53.9 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Allowable Stress Design (ASD) reported in metric tons,  Inventory Rating: 35.9 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Allowable Stress Design (ASD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020
Find on map >>   Show street view

Structure Number: L9708,  Location: 0.1 MI N OF JCT CSAH 78 (Lat: 44.609417,  Lng: -93.218033),  Route carried "on" structure: County highway 23,  Year Built: 1977,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 5,800 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,800 (year 2039),  Design Load: HS 20,  Features Intersected: STREAM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.9m (9.5ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 53.9 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Allowable Stress Design (ASD) reported in metric tons,  Inventory Rating: 35.9 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Allowable Stress Design (ASD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020
Find on map >>   Show street view

Structure Number: 19531,  Location: 1.6 MI S OF JCT 35 E;W (Lat: 44.714506,  Lng: -93.283569),  Route carried "under" structure: Interstate 35,  Year Built: 1995,  Structure Length: 0. m,  Average Daily Traffic: 81,000 (year 2019),  Truck Traffic: 9%,  Features Intersected: I 35,  Facility Carried by Structure: CSAH 46
Minimum Vertical Clearance: 5.24m (17.19ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.5m (119.8ft)

Find on map >>   Show street view

Structure Number: 19807,  Location: 2.8 MI S OF JCT TH 35 E (Lat: 44.697844,  Lng: -93.288375),  Route carried "under" structure: County highway 50,  Year Built: 1965,  Structure Length: 0. m,  Average Daily Traffic: 25,000 (year 2005),  Features Intersected: CSAH 50,  Facility Carried by Structure: I 35
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.2m (56.4ft)

Find on map >>   Show street view

Structure Number: 19808,  Location: 2.8 MI S OF JCT TH 35 E (Lat: 44.697689,  Lng: -93.288186),  Route carried "under" structure: County highway 50,  Year Built: 1965,  Structure Length: 0. m,  Average Daily Traffic: 25,000 (year 2005),  Features Intersected: CSAH 50,  Facility Carried by Structure: I 35
Minimum Vertical Clearance: 4.94m (16.21ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.2m (53.1ft)

Find on map >>   Show street view

Structure Number: 19841,  Location: 5.0 MI S OF JCT TH 35 E (Lat: 44.666917,  Lng: -93.294083),  Route carried "under" structure: Interstate 35,  Year Built: 1965,  Structure Length: 0. m,  Average Daily Traffic: 67,000 (year 2019),  Truck Traffic: 10%,  Features Intersected: I 35,  Facility Carried by Structure: MUN 24
Minimum Vertical Clearance: 5.24m (17.19ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.4m (66.9ft)

Find on map >>   Show street view

Structure Number: 19843,  Location: 6.0 MI S OF JCT TH 35 E (Lat: 44.652592,  Lng: -93.294975),  Route carried "under" structure: City street 102,  Year Built: 1965,  Structure Length: 0. m,  Average Daily Traffic: 2,900 (year 2005),  Features Intersected: CR 64 (205TH ST),  Facility Carried by Structure: I 35
Minimum Vertical Clearance: 7.04m (23.10ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.9m (65.3ft)

Find on map >>   Show street view

Structure Number: 19844,  Location: 6.0 MI S OF JCT TH 35 E (Lat: 44.652542,  Lng: -93.294633),  Route carried "under" structure: City street 102,  Year Built: 1965,  Structure Length: 0. m,  Average Daily Traffic: 2,900 (year 2005),  Features Intersected: CR 64 (205TH ST),  Facility Carried by Structure: I 35
Minimum Vertical Clearance: 6.71m (22.01ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.9m (65.3ft)

Find on map >>   Show street view

Structure Number: 1985,  Location: 6.5 MI S OF JCT TH 35 E (Lat: 44.645256,  Lng: -93.296106),  Route carried "under" structure: Interstate 35,  Year Built: 2009,  Structure Length: 0. m,  Average Daily Traffic: 47,500 (year 2019),  Truck Traffic: 12%,  Features Intersected: I 35,  Facility Carried by Structure: CSAH 70
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.2m (122.0ft)

Find on map >>   Show street view

Structure Number: 19903,  Location: 4.0 MI S OF JCT TH 3 (Lat: 44.681294,  Lng: -93.293608),  Route carried "under" structure: County highway 60,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 14,000 (year 2005),  Features Intersected: 185th ST W(CSAH 60),  Facility Carried by Structure: I 35
Minimum Vertical Clearance: 5.12m (16.80ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.9m (107.9ft)

Find on map >>   Show street view

Structure Number: 19904,  Location: 4.0 MI S OF JCT 3 (Lat: 44.681372,  Lng: -93.293236),  Route carried "under" structure: County highway 60,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 14,000 (year 2005),  Features Intersected: 185th ST W (CSAH 60),  Facility Carried by Structure: I 35
Minimum Vertical Clearance: 5.06m (16.60ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.9m (107.9ft)

Find on map >>   Show street view

Structure Number: 70805,  Location: 10.7 MI N OF JCT TH 19 (Lat: 44.623572,  Lng: -93.298233),  Route carried "under" structure: Interstate 35,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 47,500 (year 2019),  Truck Traffic: 12%,  Features Intersected: I 35,  Facility Carried by Structure: CR 29
Minimum Vertical Clearance: 4.97m (16.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.5m (67.3ft)

Discuss Lakeville, Minnesota (MN) on our hugely popular Minnesota forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.