Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Midway, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 14Number of bridges
  • 105ft / 31.9mTotal length
  • 104,120Total average daily traffic
  • 12,472Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Midway
  • No street view available for this location

New bridges in Midway, NC - historical statistics
  • New bridges - historical statistics
  • 11960-1969
  • 61970-1979
  • 31980-1989
  • 31990-1999
  • 12010-2019
Average Bridge Daily Traffic in Midway, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 60.0%Good
  • 40.0%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 20.0%Very good
  • 20.0%Good
  • 60.0%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 40.0%Good
  • 60.0%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 57.1%Good
  • 28.6%Satisfactory
  • 14.3%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 20.0%Good
  • 80.0%Satisfactory
Find on map >>   Show street view

Structure Number: 570033,  Location: 0.1 MI. N. JCT. SR1520 (Lat: 35.988392,  Lng: -80.314739),  Route carried "on" structure: State highway 1537,  Year Built: 1993,  Status: Open,  Structure Length: 1.09m (3.58ft),  Average Daily Traffic: 3,800 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 7,600 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: MILLER CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022
Find on map >>   Show street view

Structure Number: 570069,  Location: 0.7 MI.S.JCT.SR1472 (Lat: 35.931281,  Lng: -80.271900),  Route carried "on" structure: State highway 1502,  Year Built: 2014,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 530 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,060 (year 2040),  Design Load: HL 93,  Features Intersected: REEDY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 33.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 57011,  Location: 500 FT. W. JCT. SR1721 (Lat: 35.949622,  Lng: -80.180731),  Route carried "on" structure: State highway 1802,  Year Built: 1994,  Status: Open,  Structure Length: 4.11m (13.48ft),  Average Daily Traffic: 6,400 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 12,800 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BUSHY FORK CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 73.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 570114,  Location: 0.1 MI. N. JCT. SR1711 (Lat: 35.979006,  Lng: -80.219639),  Route carried "on" structure: State highway 1713,  Year Built: 1990,  Status: Open,  Structure Length: 4.32m (14.17ft),  Average Daily Traffic: 100 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 200 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: WINSTON SALEM RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.4m (53.8ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 60.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 570125,  Location: 0.1 MI. E. JCT. SR1507 (Lat: 35.957586,  Lng: -80.232364),  Route carried "on" structure: State highway 1506,  Year Built: 1977,  Status: Open,  Structure Length: 7.52m (24.67ft),  Average Daily Traffic: 610 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,220 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US52
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 38.1m (125.0ft),  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 79.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 570136,  Location: 0.2 MI. E. JCT. SR1507 (Lat: 35.970108,  Lng: -80.229642),  Route carried "on" structure: State highway 1508,  Year Built: 1977,  Status: Open,  Structure Length: 10.60m (34.78ft),  Average Daily Traffic: 14,000 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 28,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US52, NC8
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 21.6m (70.9ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 39.3m (128.9ft),  Curb-To-Curb Width: 25.6m (84.0ft),  Out-to-Out Width: 26.2m (86.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 53.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 570355,  Location: 0.5 MI. W. JCT. SR1723 (Lat: 35.977258,  Lng: -80.175783),  Route carried "on" structure: State highway 1716,  Year Built: 1987,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 1,700 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 3,400 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BRANCH OF BRUSHY FORK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 570356,  Location: 0.45 MI. W. JCT. SR1723 (Lat: 35.977175,  Lng: -80.175122),  Route carried "on" structure: State highway 1716,  Year Built: 1987,  Status: Open,  Structure Length: 1.09m (3.58ft),  Average Daily Traffic: 910 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,820 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BRUSHY FORK OVERFLOW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 570357,  Location: 0.4 MI. W. JCT. SR1723 (Lat: 35.977097,  Lng: -80.174533),  Route carried "on" structure: State highway 1716,  Year Built: 1961,  Year Reconstructed: 1987,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 910 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,820 (year 2040),  Features Intersected: BUSHY FORK CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.7m (18.7ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.6m (24.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 85.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 50.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 570427,  Location: 0.3 MI. N. JCT. SR1502 (Lat: 35.933519,  Lng: -80.261367),  Route carried "on" structure: State highway 1504,  Year Built: 1982,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 160 (year 2000),  Truck Traffic: 7%,  Average Future Daily Traffic: 320 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: PRONG OF REEDY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 1.8m (5.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 570125,  Location: 0.1 MI. E. JCT. SR1507 (Lat: 35.957586,  Lng: -80.232364),  Route carried "under" structure: US 52,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 18,750 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1506
Minimum Vertical Clearance: 5.61m (18.41ft),  Kilometerpoint: 30.114,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.1m (125.0ft)

Find on map >>   Show street view

Structure Number: 570125,  Location: 0.1 MI. E. JCT. SR1507 (Lat: 35.957586,  Lng: -80.232364),  Route carried "under" structure: US 52,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 18,750 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1506
Minimum Vertical Clearance: 5.20m (17.06ft),  Kilometerpoint: 30.114,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.1m (125.0ft)

Find on map >>   Show street view

Structure Number: 570136,  Location: 0.2 MI. E. JCT. SR1507 (Lat: 35.970108,  Lng: -80.229642),  Route carried "under" structure: US 52,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 18,750 (year 2018),  Truck Traffic: 12%,  Features Intersected: SR1508
Minimum Vertical Clearance: 6.01m (19.72ft),  Kilometerpoint: 30.419,  Lanes on structure: 4,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.3m (128.9ft)

Find on map >>   Show street view

Structure Number: 570136,  Location: 0.2 MI. E. JCT. SR1507 (Lat: 35.970108,  Lng: -80.229642),  Route carried "under" structure: US 52,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 18,750 (year 2018),  Truck Traffic: 12%,  Features Intersected: SR1508
Minimum Vertical Clearance: 6.98m (22.90ft),  Kilometerpoint: 30.419,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.3m (128.9ft)

Discuss Midway, North Carolina (NC) on our hugely popular North Carolina forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.