Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for North Mankato, Minnesota (MN)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 28Number of bridges
  • 184ft / 56.2mTotal length
  • $75,000,000Total costs
  • 177,373Total average daily traffic
  • 12,131Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for North Mankato
  • No street view available for this location

New bridges in North Mankato, MN - historical statistics
  • New bridges - historical statistics
  • 11940-1949
  • 51970-1979
  • 31980-1989
  • 151990-1999
  • 22000-2009
  • 22010-2019
Average Bridge Daily Traffic in North Mankato, MN
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 23.1%Very good
  • 61.5%Good
  • 15.4%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 23.1%Very good
  • 53.8%Good
  • 15.4%Satisfactory
  • 7.7%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 7.7%Very good
  • 53.8%Good
  • 30.8%Satisfactory
  • 7.7%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 71.4%Very good
  • 14.3%Good
  • 14.3%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 66.7%Very good
  • 33.3%Fair
Find on map >>   Show street view

Structure Number: 7043,  Location: 1.8 MI E OF JCT TH 60 (Lat: 44.145522,  Lng: -94.084053),  Route carried "on" structure: US 169,  Year Built: 1997,  Status: Open,  Structure Length: 4.57m (14.99ft),  Average Daily Traffic: 16,250 (year 2016),  Truck Traffic: 11%,  Average Future Daily Traffic: 16,250 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: CSAH 90 WB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.3m (46.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 42.7m (140.1ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 17.5m (57.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 90.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7044,  Location: 1.8 MI E OF JCT TH 60 (Lat: 44.145428,  Lng: -94.083467),  Route carried "on" structure: US 169,  Year Built: 1997,  Status: Open,  Structure Length: 3.80m (12.47ft),  Average Daily Traffic: 7,700 (year 2019),  Truck Traffic: 15%,  Average Future Daily Traffic: 16,250 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: CSAH 90 WB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 35.6m (116.8ft),  Curb-To-Curb Width: 14.9m (48.9ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 66.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 757,  Location: 0.6 MI NE OF JCT TH 169 (Lat: 44.148628,  Lng: -94.103828),  Route carried "on" structure: County highway 69,  Year Built: 1995,  Status: Open,  Structure Length: 2.06m (6.76ft),  Average Daily Traffic: 130 (year 2017),  Average Future Daily Traffic: 130 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: MINNEOPA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 63.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7572,  Location: 0.9 MI SW OF JCT TH 169 (Lat: 44.148133,  Lng: -94.095917),  Route carried "on" structure: ServiceState lands road 7,  Year Built: 1998,  Status: Open,  Structure Length: 1.60m (5.25ft),  Average Daily Traffic: 180 (year 2001),  Average Future Daily Traffic: 180 (year 2029),  Design Load: HS 25 or greater,  Features Intersected: MINNEOPA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Agenciy,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 77.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 52003,  Location: 0.8 MI W JCT LOR RAY DR (Lat: 44.186150,  Lng: -94.068419),  Route carried "on" structure: County highway 41,  Year Built: 2013,  Status: Open,  Structure Length: 6.96m (22.83ft),  Average Daily Traffic: 5,000 (year 2015),  Average Future Daily Traffic: 5,000 (year 2039),  Design Load: HL 93,  Features Intersected: US 14
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.4m (116.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.5m (11.5ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 22.0m (72.2ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 66.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 52006,  Location: 2.2 MI W OF JCT TH 169 (Lat: 44.181011,  Lng: -94.053725),  Route carried "on" structure: City street 116,  Year Built: 1974,  Status: Open,  Structure Length: 9.45m (31.00ft),  Average Daily Traffic: 8,000 (year 2011),  Average Future Daily Traffic: 8,000 (year 2039),  Design Load: HS 20,  Features Intersected: US 14
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 31.7m (104.0ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 29.5m (96.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 29.6m (97.1ft),  Out-to-Out Width: 34.3m (112.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 74.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 52007,  Location: 1.2 MI W OF JCT TH 169 (Lat: 44.181197,  Lng: -94.035469),  Route carried "on" structure: City street 117,  Year Built: 1974,  Status: Open,  Structure Length: 9.21m (30.22ft),  Average Daily Traffic: 15,100 (year 2011),  Average Future Daily Traffic: 15,100 (year 2039),  Design Load: HS 20,  Features Intersected: US 14
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 28.0m (91.9ft),  Skew: 24 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 27.8m (91.2ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 25.6m (84.0ft),  Out-to-Out Width: 32.4m (106.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 71.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 52008,  Location: 2.2 MI S OF JCT TH 14 (Lat: 44.167469,  Lng: -94.016289),  Route carried "on" structure: Ramp US 5956,  Year Built: 1992,  Status: Open,  Structure Length: 2.37m (7.78ft),  Average Daily Traffic: 2,800 (year 1994),  Average Future Daily Traffic: 2,800 (year 2029),  Design Load: HS 25 or greater,  Features Intersected: US 169; RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.3m (73.2ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 6.9m (22.6ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 61.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 52009,  Location: 1.6 MI S OF JCT TH 14 (Lat: 44.169936,  Lng: -94.005028),  Route carried "on" structure: US 169,  Year Built: 1985,  Status: Open,  Structure Length: 4.41m (14.47ft),  Average Daily Traffic: 20,700 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 21,500 (year 2039),  Design Load: HS 20,  Features Intersected: US 169
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 21 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 22.5m (73.8ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 24.4m (80.1ft),  Out-to-Out Width: 32.4m (106.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 51.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 29.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 52011,  Location: 2.2 MI S OF JCT TH 14 (Lat: 44.167450,  Lng: -94.013664),  Route carried "on" structure: Ramp Other road 14,  Year Built: 1992,  Status: Open,  Structure Length: 3.07m (10.07ft),  Average Daily Traffic: 2,000 (year 1994),  Average Future Daily Traffic: 2,000 (year 2029),  Design Load: HS 25 or greater,  Features Intersected: US 169 RAMPS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.1m (95.5ft),  Curb-To-Curb Width: 6.9m (22.6ft),  Out-to-Out Width: 8.0m (26.2ft)

Condition: Deck: Very good,  Superstructure: Poor,  Substructure: Good,  Operating Rating: 56.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 52012,  Location: 2.2 MI S OF JCT TH 14 (Lat: 44.167233,  Lng: -94.013625),  Route carried "on" structure: US 169,  Year Built: 1992,  Status: Open,  Structure Length: 2.90m (9.51ft),  Average Daily Traffic: 21,000 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 21,500 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: US 169 RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 34.4m (112.9ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 27.5m (90.2ft),  Curb-To-Curb Width: 30.5m (100.1ft),  Out-to-Out Width: 34.7m (113.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 61.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 52506,  Location: 4.8 MI SE OF JCT 461ST ST (Lat: 44.179981,  Lng: -94.105347),  Route carried "on" structure: County highway 41,  Year Built: 1979,  Status: Open,  Structure Length: 1.94m (6.36ft),  Average Daily Traffic: 310 (year 2015),  Average Future Daily Traffic: 310 (year 2039),  Design Load: HS 20,  Features Intersected: STREAM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.6m (61.0ft),  Curb-To-Curb Width: 11.2m (36.7ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 74.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 52509,  Location: 2.9 MI W OF LOOKOUT DRIV (Lat: 44.170283,  Lng: -94.085036),  Route carried "on" structure: County highway 41,  Year Built: 1986,  Status: Open,  Structure Length: 1.49m (4.89ft),  Average Daily Traffic: 310 (year 2015),  Average Future Daily Traffic: 310 (year 2039),  Design Load: HS 20,  Features Intersected: STREAM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 42.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 27.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 52J08,  Location: 5.0 MI E OF JCT 461ST. AV (Lat: 44.175544,  Lng: -94.094078),  Route carried "on" structure: County highway 41,  Year Built: 2000,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 310 (year 2015),  Average Future Daily Traffic: 310 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: STREAM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 58.8 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2020
Find on map >>   Show street view

Structure Number: 52J13,  Location: 2.0 mi W of Lookout Drive (Lat: 44.164631,  Lng: -94.068292),  Route carried "on" structure: County highway 71,  Year Built: 2002,  Status: Open,  Structure Length: 0.87m (2.85ft),  Average Daily Traffic: 300 (year 2011),  Average Future Daily Traffic: 300 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: Stream
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.8m (12.5ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 68.6 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2020
Find on map >>   Show street view

Structure Number: 6357,  Location: 3.5 MI W OF MANKATO (Lat: 44.153153,  Lng: -94.082686),  Route carried "on" structure: State highway 68,  Year Built: 1942,  Status: Open,  Structure Length: 0.69m (2.26ft),  Average Daily Traffic: 2,600 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 2,450 (year 2039),  Features Intersected: MINNEOPA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 39.2 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Allowable Stress Design (ASD) reported in metric tons,  Inventory Rating: 29.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Allowable Stress Design (ASD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.34m (1.12ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Bridge Improvement Cost: $86,000,000,  Roadway Improvement Cost: $5,000,000,  Total Project Cost: $75,000,000
Find on map >>   Show street view

Structure Number: 7043,  Location: 1.8 MI E OF JCT TH 60 (Lat: 44.145522,  Lng: -94.084053),  Route carried "under" structure: Ramp US 61,  Year Built: 1997,  Structure Length: 0. m,  Average Daily Traffic: 1,300 (year 2005),  Features Intersected: CSAH 90 WB,  Facility Carried by Structure: US 169
Minimum Vertical Clearance: 4.97m (16.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 42.7m (140.1ft)

Find on map >>   Show street view

Structure Number: 7044,  Location: 1.8 MI E OF JCT TH 60 (Lat: 44.145428,  Lng: -94.083467),  Route carried "under" structure: Ramp US 61,  Year Built: 1997,  Structure Length: 0. m,  Average Daily Traffic: 1,300 (year 2005),  Features Intersected: CSAH 90 WB,  Facility Carried by Structure: US 169
Minimum Vertical Clearance: 6.58m (21.59ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.6m (116.8ft)

Find on map >>   Show street view

Structure Number: 52003,  Location: 0.8 MI W JCT LOR RAY DR (Lat: 44.186150,  Lng: -94.068419),  Route carried "under" structure: US 14,  Year Built: 2013,  Structure Length: 0. m,  Average Daily Traffic: 10,082 (year 2019),  Truck Traffic: 11%,  Features Intersected: US 14,  Facility Carried by Structure: CSAH 41
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 0.000,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 52006,  Location: 2.2 MI W OF JCT TH 169 (Lat: 44.181011,  Lng: -94.053725),  Route carried "under" structure: US 14,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 14,500 (year 2019),  Truck Traffic: 7%,  Features Intersected: US 14,  Facility Carried by Structure: MSAS 116
Minimum Vertical Clearance: 5.36m (17.59ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.5m (96.8ft)

Find on map >>   Show street view

Structure Number: 52007,  Location: 1.2 MI W OF JCT TH 169 (Lat: 44.181197,  Lng: -94.035469),  Route carried "under" structure: US 14,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 14,500 (year 2019),  Truck Traffic: 7%,  Features Intersected: US 14,  Facility Carried by Structure: MSAS 117
Minimum Vertical Clearance: 5.46m (17.91ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.8m (91.2ft)

Find on map >>   Show street view

Structure Number: 52008,  Location: 2.2 MI S OF JCT TH 14 (Lat: 44.167469,  Lng: -94.016289),  Route carried "under" structure: US 14,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 3,000 (year 1994),  Features Intersected: US 169; RAMP,  Facility Carried by Structure: CON 5956
Minimum Vertical Clearance: 4.97m (16.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.3m (73.2ft)

Find on map >>   Show street view

Structure Number: 52008,  Location: 2.2 MI S OF JCT TH 14 (Lat: 44.167469,  Lng: -94.016289),  Route carried "under" structure: Ramp US 4844,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 3,000 (year 1994),  Features Intersected: US 169; RAMP,  Facility Carried by Structure: CON 5956
Minimum Vertical Clearance: 4.97m (16.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.3m (73.2ft)

Find on map >>   Show street view

Structure Number: 52009,  Location: 1.6 MI S OF JCT TH 14 (Lat: 44.169936,  Lng: -94.005028),  Route carried "under" structure: US 169,  Year Built: 1985,  Structure Length: 0. m,  Average Daily Traffic: 21,000 (year 2019),  Truck Traffic: 12%,  Features Intersected: US 169
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Length of Maximum Span: 22.5m (73.8ft)

Find on map >>   Show street view

Structure Number: 52011,  Location: 2.2 MI S OF JCT TH 14 (Lat: 44.167450,  Lng: -94.013664),  Route carried "under" structure: Ramp US 5960,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 2,000 (year 1994),  Features Intersected: US 169 RAMPS,  Facility Carried by Structure: CON 14
Minimum Vertical Clearance: 5.06m (16.60ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.1m (95.5ft)

Find on map >>   Show street view

Structure Number: 52011,  Location: 2.2 MI S OF JCT TH 14 (Lat: 44.167450,  Lng: -94.013664),  Route carried "under" structure: Ramp US 4844,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 1,000 (year 1994),  Features Intersected: US 169 RAMPS,  Facility Carried by Structure: CON 14
Minimum Vertical Clearance: 4.94m (16.21ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.1m (95.5ft)

Find on map >>   Show street view

Structure Number: 52012,  Location: 2.2 MI S OF JCT TH 14 (Lat: 44.167233,  Lng: -94.013625),  Route carried "under" structure: Ramp US 4844,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 3,000 (year 1994),  Features Intersected: US 169 RAMP,  Facility Carried by Structure: US 169
Minimum Vertical Clearance: 5.52m (18.11ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.5m (90.2ft)

Find on map >>   Show street view

Structure Number: 52012,  Location: 2.2 MI S OF JCT TH 14 (Lat: 44.167233,  Lng: -94.013625),  Route carried "under" structure: Ramp US 5960,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 1 (year 2019),  Features Intersected: US 169 RAMP,  Facility Carried by Structure: US 169
Minimum Vertical Clearance: 5.49m (18.01ft),  Kilometerpoint: 0.000,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.5m (90.2ft)

Discuss North Mankato, Minnesota (MN) on our hugely popular Minnesota forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.