Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for North Port, Florida (FL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 92Number of bridges
  • 1,198ft / 365mTotal length
  • $983,000Total costs
  • 1,129,484Total average daily traffic
  • 113,679Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for North Port
  • No street view available for this location

New bridges in North Port, FL - historical statistics
  • New bridges - historical statistics
  • 81960-1969
  • 221970-1979
  • 411980-1989
  • 111990-1999
  • 52000-2009
  • 52010-2019
Reconstructed bridges in North Port, FL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21980-1989
  • 81990-1999
  • 12000-2009
  • 102010-2019
Average Bridge Daily Traffic in North Port, FL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 4.5%Very good
  • 58.2%Good
  • 26.9%Satisfactory
  • 6.0%Fair
  • 4.5%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 3.0%Very good
  • 62.7%Good
  • 23.9%Satisfactory
  • 6.0%Fair
  • 4.5%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 6.0%Very good
  • 86.6%Good
  • 7.5%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 16.7%Excellent
  • 9.7%Very good
  • 55.6%Good
  • 18.1%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Good
  • 50.0%Satisfactory
Find on map >>   Show street view

Structure Number: 10108,  Location: 0.4MI. N OF LONGLEY DR. (Lat: 27.026611,  Lng: -82.195911),  Route carried "on" structure: US 41,  Year Built: 1974,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 29,000 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 50,315 (year 2042),  Design Load: H 20,  Features Intersected: BAYSHORE WATERWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 40.592,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 27.4m (89.9ft),  Skew: 12 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 81.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 62.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 14039,  Location: 0.8MI SOUTH OF US-41 (Lat: 27.021306,  Lng: -82.205250),  Route carried "on" structure: County highway ,  Year Built: 1968,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 3.35m (10.99ft),  Average Daily Traffic: 3,700 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,420 (year 2041),  Design Load: H 20,  Features Intersected: BAYSHORE WATERWAY,  Facility Carried by Structure: CORNELIUS BLVD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.133,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.8m (22.3ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.1m (39.7ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 46.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Underwater Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 14044,  Location: 0.4MI W OF CORNELIUS BLVD (Lat: 27.018289,  Lng: -82.210750),  Route carried "on" structure: County highway ,  Year Built: 1970,  Status: Open,  Structure Length: 4.11m (13.48ft),  Average Daily Traffic: 1,200 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,082 (year 2041),  Design Load: HS 20,  Features Intersected: JUPITER WATERWAY,  Facility Carried by Structure: CHAMBERLAIN BLVD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.664,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.7m (25.3ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 8.2m (26.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 51.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Underwater Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 14045,  Location: 1.3MI W OF CORNELIUS BLVD (Lat: 27.018347,  Lng: -82.226014),  Route carried "on" structure: County highway ,  Year Built: 1970,  Status: Open,  Structure Length: 4.42m (14.50ft),  Average Daily Traffic: 1,200 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 2,082 (year 2041),  Design Load: HS 20,  Features Intersected: APOLLO WATERWAY,  Facility Carried by Structure: CHAMBERLAIN BLVD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.146,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.2m (23.6ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 8.8m (28.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 71.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Underwater Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 14047,  Location: 3MI W OF CORNELIUS BLVD. (Lat: 27.025494,  Lng: -82.249983),  Route carried "on" structure: County highway ,  Year Built: 1970,  Status: Open,  Structure Length: 2.77m (9.09ft),  Average Daily Traffic: 1,200 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,082 (year 2041),  Design Load: HS 20,  Features Intersected: MARKHAM WATERWAY,  Facility Carried by Structure: CHAMBERLAIN BLVD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.455,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.2m (23.6ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.2m (30.2ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 67.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Underwater Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 14048,  Location: 0.2MI N OF ELEANOR (Lat: 27.006833,  Lng: -82.222194),  Route carried "on" structure: County highway ,  Year Built: 1970,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 4.27m (14.01ft),  Average Daily Traffic: 2,800 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,858 (year 2041),  Design Load: HL 93,  Features Intersected: JUPITER WATERWAY,  Facility Carried by Structure: JACOBS STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.111,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.1m (23.3ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 57.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Underwater Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 14049,  Location: 0.4MI W OF CORNELIUS BLVD (Lat: 27.015028,  Lng: -82.212944),  Route carried "on" structure: City street ,  Year Built: 1972,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 1,450 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,516 (year 2041),  Design Load: HS 20,  Features Intersected: JUPITER WATERWAY,  Facility Carried by Structure: BISCAYNE DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.174,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 7.9m (25.9ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 69.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Underwater Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 170055,  Location: 100FT S OF US-41 (Lat: 27.041222,  Lng: -82.299869),  Route carried "on" structure: County highway 777,  Year Built: 1965,  Year Reconstructed: 1996,  Status: Open,  Structure Length: 0.81m (2.66ft),  Average Daily Traffic: 13,500 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 23,423 (year 2042),  Design Load: HS 20,  Features Intersected: BRANCH OF MYAKKA RIVER,  Facility Carried by Structure: SOUTH RIVER ROAD
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 12.287,  Lanes on structure: 7,  Owner: County Highway Agency,  Approaching Roadway Width: 31.2m (102.4ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Very good,  Culverts: Good,  Inventory Rating: 62.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 170063,  Location: 650FT N OF CHARLOTTE CTY (Lat: 27.033689,  Lng: -82.206744),  Route carried "on" structure: US 41,  Year Built: 1974,  Year Reconstructed: 2015,  Status: Open,  Structure Length: 0.66m (2.17ft),  Average Daily Traffic: 31,500 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 54,652 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: JUPITER WATERWAY
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 0.188,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.2m (82.7ft),  Skew: 10 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.3m (10.8ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Inventory Rating: 74.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Underwater Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 170067,  Location: 8.6MI E OF I-75 (Lat: 27.237803,  Lng: -82.315081),  Route carried "on" structure: State highway 72,  Year Built: 2008,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 2,400 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 4,164 (year 2042),  Design Load: HL 93,  Features Intersected: MYAKKA RIVER OVERFLOW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.956,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 14.9m (48.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 50.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 38.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170071,  Location: 15.6 MI East of I-75 (Lat: 27.195608,  Lng: -82.216781),  Route carried "on" structure: State highway 72,  Year Built: 2008,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 2,400 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 4,164 (year 2042),  Design Load: HL 93,  Features Intersected: DEER PRAIRIE SLOUGH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.975,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 14.9m (48.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 50.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 38.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 23 months,  Inspection Date: June 2021,  Underwater Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170073,  Location: 1.4MI N OF SUMTER BLVD (Lat: 27.044958,  Lng: -82.241936),  Route carried "on" structure: US 41,  Year Built: 1975,  Status: Open,  Structure Length: 7.32m (24.02ft),  Average Daily Traffic: 15,750 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 27,326 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: BIG SLOUGH
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 3.867,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 47.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Underwater Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170074,  Location: 1.4MI N OF SUMTER BLVD (Lat: 27.045147,  Lng: -82.241933),  Route carried "on" structure: US 41,  Year Built: 1975,  Status: Open,  Structure Length: 7.32m (24.02ft),  Average Daily Traffic: 15,750 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 27,326 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: BIG SLOUGH
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 3.867,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 47.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Underwater Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170114,  Location: 0.6MI S OF RIVER RD. (Lat: 27.046189,  Lng: -82.291378),  Route carried "on" structure: US 41,  Year Built: 1977,  Status: Open,  Structure Length: 5.19m (17.03ft),  Average Daily Traffic: 15,750 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 27,326 (year 2042),  Design Load: HS 20,  Features Intersected: MYAKKA RIVER EAST BRANCH
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 8.876,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 13.0m (42.7ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Underwater Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170115,  Location: 0.6MI S OF RIVER RD. (Lat: 27.045983,  Lng: -82.291314),  Route carried "on" structure: US 41,  Year Built: 1977,  Status: Open,  Structure Length: 5.19m (17.03ft),  Average Daily Traffic: 15,750 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 27,326 (year 2042),  Design Load: HS 20,  Features Intersected: MYAKKA RIVER EAST BRANCH
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 8.876,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 13.0m (42.7ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Underwater Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170116,  Location: 0.5MI S OF RIVER ROAD (Lat: 27.045231,  Lng: -82.293031),  Route carried "on" structure: US 41,  Year Built: 1977,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 11.35m (37.24ft),  Average Daily Traffic: 15,750 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 27,326 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: MYAKKA RIVER
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 9.041,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 14.2m (46.6ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 69.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Underwater Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170117,  Location: 0.5MI S OF RIVER RD (Lat: 27.045036,  Lng: -82.292931),  Route carried "on" structure: US 41,  Year Built: 1977,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 11.35m (37.24ft),  Average Daily Traffic: 15,750 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 27,326 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: MYAKKA RIVER
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 9.041,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 14.2m (46.6ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 69.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Underwater Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170121,  Location: 1.1 MI NORTH OF US-41 (Lat: 27.033475,  Lng: -82.163533),  Route carried "on" structure: City street ,  Year Built: 1982,  Status: Open,  Structure Length: 5.27m (17.29ft),  Average Daily Traffic: 16,800 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 29,148 (year 2042),  Design Load: HS 20,  Features Intersected: COCOPLUM WATERWAY,  Facility Carried by Structure: TOLEDO BLADE BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.056,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.0m (29.5ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 11.1m (36.4ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 85.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 66.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Underwater Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 170122,  Location: 4.2 MI NORTH OF US-41 (Lat: 27.075944,  Lng: -82.155525),  Route carried "on" structure: City street ,  Year Built: 1982,  Status: Open,  Structure Length: 3.49m (11.45ft),  Average Daily Traffic: 10,500 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 18,218 (year 2041),  Design Load: HS 20,  Features Intersected: SNOVER CANAL,  Facility Carried by Structure: TOLEDO BLADE NB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.941,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.7m (38.4ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 85.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 67.1 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 170123,  Location: 12.8 MI N OF CHARLOTTE CO (Lat: 27.099653,  Lng: -82.232233),  Route carried "on" structure: County highway ,  Year Built: 1981,  Status: Open,  Structure Length: 8.74m (28.67ft),  Average Daily Traffic: 2,900 (year 2018),  Truck Traffic: 8%,  Average Future Daily Traffic: 5,032 (year 2040),  Design Load: HS 20,  Features Intersected: I-75 (SR-93),  Facility Carried by Structure: PONCE DE LEON BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.578,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 34.4m (112.9ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 39.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 34.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170124,  Location: 4.5MI N OF SUMTER BLVD (Lat: 27.099853,  Lng: -82.271481),  Route carried "on" structure: Interstate 75,  Year Built: 1981,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 4.11m (13.48ft),  Average Daily Traffic: 37,953 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 65,848 (year 2042),  Design Load: HL 93,  Features Intersected: DEER PRAIRIE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.427,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.6m (67.6ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 8.2m (26.9ft),  Curb-To-Curb Width: 20.6m (67.6ft),  Out-to-Out Width: 21.7m (71.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 46.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170125,  Location: 4.5MI N OF SUMTER BLVD (Lat: 27.100236,  Lng: -82.271372),  Route carried "on" structure: Interstate 75,  Year Built: 1981,  Year Reconstructed: 2015,  Status: Open,  Structure Length: 4.11m (13.48ft),  Average Daily Traffic: 37,953 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 65,848 (year 2042),  Design Load: HL 93,  Features Intersected: DEER PRAIRIE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.415,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 8.2m (26.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 21.6m (70.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 46.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 23 months,  Inspection Date: March 2021,  Underwater Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170129,  Location: 10.9 MI N OF CHARLOTTE CL (Lat: 27.099108,  Lng: -82.203289),  Route carried "on" structure: Interstate 75,  Year Built: 1981,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 5.39m (17.68ft),  Average Daily Traffic: 32,000 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 55,520 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: SUMTER BLVD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.663,  Lanes on structure: 3,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.5m (57.4ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 31.5m (103.3ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 48.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 17013,  Location: 10.9MI N OF CHARLOTTE CL (Lat: 27.099481,  Lng: -82.203250),  Route carried "on" structure: Interstate 75,  Year Built: 1981,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 5.39m (17.68ft),  Average Daily Traffic: 32,000 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 55,520 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: SUMTER BLVD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.663,  Lanes on structure: 3,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.9m (55.4ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 31.5m (103.3ft),  Curb-To-Curb Width: 16.9m (55.4ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 48.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170131,  Location: 0.3MI N OF SUMTER BLVD (Lat: 27.099194,  Lng: -82.209694),  Route carried "on" structure: Interstate 75,  Year Built: 1981,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 16.46m (54.00ft),  Average Daily Traffic: 37,953 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 65,848 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: BIG SLOUGH CANAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.269,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 48.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 16.46m (54.00ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Bridge Improvement Cost: $94,000,  Roadway Improvement Cost: $9,000,  Total Project Cost: $103,000,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170132,  Location: 0.3MI N OF SUMTER BLVD (Lat: 27.099544,  Lng: -82.209317),  Route carried "on" structure: Interstate 75,  Year Built: 1981,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 16.46m (54.00ft),  Average Daily Traffic: 37,953 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 65,848 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: BIG SLOUGH CANAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.235,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Excellent,  Operating Rating: 48.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170133,  Location: 1.1MI N OF CHARLOTTE CL (Lat: 27.044872,  Lng: -82.068492),  Route carried "on" structure: Interstate 75,  Year Built: 1980,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 8.75m (28.71ft),  Average Daily Traffic: 28,000 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 48,580 (year 2042),  Design Load: HL 93,  Features Intersected: RAINTREE BLVD.
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 1.891,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.6m (93.8ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 46.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 43.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170134,  Location: 1.1MI N OF CHARLOTTE CL (Lat: 27.045086,  Lng: -82.068206),  Route carried "on" structure: Interstate 75,  Year Built: 1980,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 8.75m (28.71ft),  Average Daily Traffic: 28,000 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 48,580 (year 2042),  Design Load: HL 93,  Features Intersected: RAINTREE BLVD.
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 1.888,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.6m (93.8ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 46.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 43.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170135,  Location: 2.5 MI N OF CHARLOTTE CL (Lat: 27.059731,  Lng: -82.085072),  Route carried "on" structure: Interstate 75,  Year Built: 1980,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 5.04m (16.54ft),  Average Daily Traffic: 28,000 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 48,580 (year 2042),  Design Load: HL 93,  Features Intersected: YORKSHIRE ST.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.234,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 27.1m (88.9ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 34.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170136,  Location: 2.5 MI N OF CHARLOTTE CL (Lat: 27.059964,  Lng: -82.084806),  Route carried "on" structure: Interstate 75,  Year Built: 1980,  Year Reconstructed: 2017,  Status: Open,  Structure Length: 5.04m (16.54ft),  Average Daily Traffic: 28,000 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 48,580 (year 2042),  Design Load: HL 93,  Features Intersected: YORKSHIRE ST.
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 4.234,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 27.1m (88.9ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 34.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170137,  Location: 3.4MI S OF TOLEDO BLADE (Lat: 27.079900,  Lng: -82.107606),  Route carried "on" structure: Interstate 75,  Year Built: 1981,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 4.00m (13.12ft),  Average Daily Traffic: 28,000 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 48,580 (year 2042),  Design Load: HL 93,  Features Intersected: NEW CASTLE WATERWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.398,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 10.0m (32.8ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 42.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170138,  Location: 3.4MI S OF TOLEDO BLADE (Lat: 27.080167,  Lng: -82.107389),  Route carried "on" structure: Interstate 75,  Year Built: 1981,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 4.00m (13.12ft),  Average Daily Traffic: 28,000 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 48,580 (year 2042),  Design Load: HL 93,  Features Intersected: NEW CASTLE WATERWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.403,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 10.0m (32.8ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 42.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170139,  Location: 8.0 MI N/O CHARLOTTE CL (Lat: 27.098558,  Lng: -82.155425),  Route carried "on" structure: Interstate 75,  Year Built: 1981,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 5.79m (19.00ft),  Average Daily Traffic: 28,000 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 48,580 (year 2042),  Design Load: HL 93,  Features Intersected: TOLEDO BLADE BOULEVARD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.917,  Lanes on structure: 3,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.8m (68.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.8m (107.6ft),  Curb-To-Curb Width: 20.8m (68.2ft),  Out-to-Out Width: 21.7m (71.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 62.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 33.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.79m (19.00ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Bridge Improvement Cost: $400,000,  Roadway Improvement Cost: $40,000,  Total Project Cost: $440,000,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 17014,  Location: 8.0 MI N OF CHARLOTTE CL (Lat: 27.098928,  Lng: -82.155419),  Route carried "on" structure: Interstate 75,  Year Built: 1981,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 5.79m (19.00ft),  Average Daily Traffic: 28,000 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 48,580 (year 2042),  Design Load: HS 20,  Features Intersected: TOLEDO BLADE BOULEVARD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.917,  Lanes on structure: 3,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.8m (107.6ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 33.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.79m (19.00ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Bridge Improvement Cost: $400,000,  Roadway Improvement Cost: $40,000,  Total Project Cost: $440,000,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 170144,  Location: 300FT. E OF RIVER RD (Lat: 27.042097,  Lng: -82.298939),  Route carried "on" structure: US 41,  Year Built: 1977,  Status: Open,  Structure Length: 1.20m (3.94ft),  Average Daily Traffic: 31,500 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 54,652 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: MYAKKA RIVER DRAIN CANAL
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 9.775,  Lanes on structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 37.6m (123.4ft),  Skew: 14 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.0m (13.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Underwater Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 170157,  Location: 1.25MI S OF SUMTER BLVD (Lat: 27.099056,  Lng: -82.179972),  Route carried "on" structure: Interstate 75,  Year Built: 1981,  Status: Open,  Structure Length: 0.95m (3.12ft),  Average Daily Traffic: 64,000 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 111,040 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: COSMIC WATERWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.376,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 33.5m (109.9ft),  Skew: 10 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.2m (10.5ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Underwater Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 175,  Location: 0.12 MI NORTH OF US-41 (Lat: 27.045558,  Lng: -82.235294),  Route carried "on" structure: City street ,  Year Built: 1964,  Status: Posted for load,  Structure Length: 4.63m (15.19ft),  Average Daily Traffic: 2,800 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 4,858 (year 2042),  Design Load: HS 20,  Features Intersected: COCOPLUM WATERWAY,  Facility Carried by Structure: NORTH PORT BLVD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.888,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 9.3m (30.5ft),  Curb or Sidewalk Widths: Left: 1.0m (3.3ft),  Right: 0.0m,  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 33.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: July 2020,  Underwater Inspection Date: June 2020,  Other Special Inspection Date: July 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 175001,  Location: 0.1 MI NORTH OF US-41 (Lat: 27.046553,  Lng: -82.243336),  Route carried "on" structure: City street ,  Year Built: 1964,  Status: Open,  Structure Length: 2.55m (8.37ft),  Average Daily Traffic: 5,100 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 8,849 (year 2041),  Design Load: HS 20,  Features Intersected: MYAKKA CREEK,  Facility Carried by Structure: PAN AMERICAN BLVD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.129,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.0m (26.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 41.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Underwater Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 175003,  Location: 160FT N OF HILLSBOROUGH B (Lat: 27.033333,  Lng: -82.156142),  Route carried "on" structure: City street ,  Year Built: 1968,  Status: Posted for load-capacity,  Structure Length: 5.04m (16.54ft),  Average Daily Traffic: 1,700 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,950 (year 2042),  Design Load: HS 20,  Features Intersected: COCOPLUM WATERWAY,  Facility Carried by Structure: COLLINGSWOOD BLVD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.0m (26.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 10.1m (33.1ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 39.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Underwater Inspection Date: June 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 175004,  Location: 160FT N OF HILLSBOROUGH B (Lat: 27.033417,  Lng: -82.183442),  Route carried "on" structure: City street ,  Year Built: 1969,  Status: Posted for load-capacity,  Structure Length: 5.04m (16.54ft),  Average Daily Traffic: 6,000 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 10,410 (year 2041),  Design Load: HS 20,  Features Intersected: COCOPLUM WATERWAY,  Facility Carried by Structure: CHAMBERLAIN BLVD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.063,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.0m (26.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 10.1m (33.1ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Underwater Inspection Date: June 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 175005,  Location: 0.2 MI NORTH OF US-41 (Lat: 27.034378,  Lng: -82.202675),  Route carried "on" structure: City street ,  Year Built: 1969,  Status: Open,  Structure Length: 4.56m (14.96ft),  Average Daily Traffic: 6,000 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 10,410 (year 2041),  Design Load: HS 20,  Features Intersected: COCOPLUM WATERWAY,  Facility Carried by Structure: CRANBERRY BLVD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.119,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.5m (24.6ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 66.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Underwater Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 175006,  Location: 0.1 MI NORTH OF US-41 (Lat: 27.035964,  Lng: -82.207425),  Route carried "on" structure: City street ,  Year Built: 1969,  Status: Open,  Structure Length: 4.70m (15.42ft),  Average Daily Traffic: 5,200 (year 2019),  Truck Traffic: 3%,  Average Future Daily Traffic: 9,022 (year 2041),  Design Load: HS 20,  Features Intersected: COCOPLUM WATERWAY,  Facility Carried by Structure: S. SALFORD BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.188,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 9.4m (30.8ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 47.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Underwater Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Discuss North Port, Florida (FL) on our hugely popular Florida forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.