Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Northville, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 25Number of bridges
  • 135ft / 41.4mTotal length
  • $360,000Total costs
  • 240,710Total average daily traffic
  • 13,128Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Northville
  • No street view available for this location

New bridges in Northville, MI - historical statistics
  • New bridges - historical statistics
  • 41920-1929
  • 91930-1939
  • 11940-1949
  • 21950-1959
  • 51960-1969
  • 11970-1979
  • 11990-1999
  • 22000-2009
Reconstructed bridges in Northville, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21970-1979
  • 21980-1989
  • 11990-1999
Average Bridge Daily Traffic in Northville, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 23.1%Satisfactory
  • 38.5%Fair
  • 30.8%Poor
  • 7.7%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 15.4%Good
  • 15.4%Satisfactory
  • 38.5%Fair
  • 23.1%Poor
  • 7.7%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 23.1%Good
  • 38.5%Satisfactory
  • 30.8%Fair
  • 7.7%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 11.1%Very good
  • 11.1%Good
  • 22.2%Satisfactory
  • 27.8%Fair
  • 22.2%Poor
  • 5.6%Serious
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 22.2%Very good
  • 22.2%Good
  • 33.3%Satisfactory
  • 22.2%Fair
Find on map >>   Show street view

Structure Number: 121,  Location: 2.0 MI NE OF SAUGATUCK (Lat: 42.682314,  Lng: -86.169836),  Route carried "on" structure: County highway 303,  Year Built: 1964,  Status: Open,  Structure Length: 8.44m (27.69ft),  Average Daily Traffic: 9,016 (year 1996),  Truck Traffic: 3%,  Average Future Daily Traffic: 4,550 (year 1977),  Design Load: HS 20,  Features Intersected: I-196 & US-31,  Facility Carried by Structure: OLD US-31
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.499,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 13.0m (42.7ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.8m (94.5ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Poor,  Operating Rating: 71.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 8245,  Location: 0.15 MI E OF OAKLAND AVE (Lat: 42.438075,  Lng: -83.473369),  Route carried "on" structure: City street ,  Year Built: 1994,  Status: Open,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 500 (year 1989),  Truck Traffic: 7%,  Average Future Daily Traffic: 600 (year 2013),  Design Load: HS 20+Mod,  Features Intersected: MIDDLE RIVER ROUGE,  Facility Carried by Structure: OLD NOVI ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.048,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.7m (31.8ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 54.6 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 12085,  Location: NORTHVILLE TWP W/BECK (Lat: 42.408294,  Lng: -83.516853),  Route carried "on" structure: County highway 8292,  Year Built: 1935,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 6,222 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 6,875 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: JOHNSON DRAIN,  Facility Carried by Structure: SIX MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.762,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 55.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 16 months,  Inspection Date: January 2022
Find on map >>   Show street view

Structure Number: 12086,  Location: NORTHVILLE T W/NORTHV RD (Lat: 42.410892,  Lng: -83.470822),  Route carried "on" structure: County highway 2057,  Year Built: 1933,  Status: Posted for load,  Structure Length: 1.82m (5.97ft),  Average Daily Traffic: 9,326 (year 1997),  Truck Traffic: 5%,  Average Future Daily Traffic: 12,000 (year 2015),  Design Load: H 20,  Features Intersected: MIDDLE ROUGE RIVER,  Facility Carried by Structure: SIX MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.565,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.4m (53.8ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 17.0m (55.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 29.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 17.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 12087,  Location: NORTHVILLE T W/NORTHV RD (Lat: 42.410653,  Lng: -83.471922),  Route carried "on" structure: County highway 2057,  Year Built: 1933,  Status: Posted for load,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 9,326 (year 1997),  Truck Traffic: 5%,  Average Future Daily Traffic: 12,000 (year 2015),  Design Load: HS 20+Mod,  Features Intersected: EN HINES DRIVE,  Facility Carried by Structure: SIX MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.470,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.2m (59.7ft),  Curb or Sidewalk Widths: Left: 1.9m (6.2ft),  Right: 1.9m (6.2ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 16.4m (53.8ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Satisfactory,  Operating Rating: 25.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 15.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 12093,  Location: NORTHVILLE T E/BECK (Lat: 42.423383,  Lng: -83.504122),  Route carried "on" structure: County highway 2057,  Year Built: 1934,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 6,799 (year 1995),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,092 (year 2015),  Features Intersected: N/BRANCH JOHNSON DRAIN,  Facility Carried by Structure: SEVEN MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.877,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 5.4m (17.7ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 11.7m (38.4ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 51.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: 12094,  Location: NORTHVILLE W/NORTHVILL RD (Lat: 42.425542,  Lng: -83.477889),  Route carried "on" structure: County highway 2057,  Year Built: 1954,  Status: Open,  Structure Length: 1.98m (6.50ft),  Average Daily Traffic: 7,853 (year 1995),  Truck Traffic: 3%,  Average Future Daily Traffic: 6,640 (year 2015),  Design Load: HS 20,  Features Intersected: MIDDLE ROUGE RIVER,  Facility Carried by Structure: SEVEN MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.222,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 16.4m (53.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Poor,  Operating Rating: 86.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 12099,  Location: NORTHVILLE E/CENTER (Lat: 42.439800,  Lng: -83.476050),  Route carried "on" structure: County highway 2057,  Year Built: 1960,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 18,988 (year 1996),  Truck Traffic: 8%,  Average Future Daily Traffic: 17,675 (year 2015),  Design Load: HS 20+Mod,  Features Intersected: MIDDLE ROUGE RIVER,  Facility Carried by Structure: BASE LINE/NOVI RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.403,  Lanes on structure: 6,  Owner: County Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft),  Out-to-Out Width: 76.2m (250.0ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 97.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: 12101,  Location: NORTHVILLE E/NOVI RD (Lat: 42.439861,  Lng: -83.474528),  Route carried "on" structure: County highway 2057,  Year Built: 1960,  Status: Open,  Structure Length: 5.49m (18.01ft),  Average Daily Traffic: 35,730 (year 2015),  Truck Traffic: 12%,  Average Future Daily Traffic: 37,880 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: CSX RR,  Facility Carried by Structure: BASE LINE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.518,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.9m (71.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Deck: Serious,  Superstructure: Good,  Substructure: Good,  Operating Rating: 66.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 12107,  Location: NORTHVILLE T N/SIX MILE (Lat: 42.411928,  Lng: -83.511181),  Route carried "on" structure: County highway 2057,  Year Built: 1930,  Year Reconstructed: 1989,  Status: Posted for load,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 16,972 (year 1997),  Truck Traffic: 3%,  Average Future Daily Traffic: 16,009 (year 2015),  Features Intersected: JOHNSON DRAIN,  Facility Carried by Structure: BECK ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 16.073,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 36.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 12114,  Location: NORTHVILLE S/E N HINES DR (Lat: 42.425475,  Lng: -83.482589),  Route carried "on" structure: County highway 2057,  Year Built: 1933,  Status: Open,  Structure Length: 1.18m (3.87ft),  Average Daily Traffic: 10,057 (year 1997),  Truck Traffic: 3%,  Average Future Daily Traffic: 11,719 (year 2015),  Design Load: H 20,  Features Intersected: JOHNSON DRAIN,  Facility Carried by Structure: SHELDON ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.778,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 549,  Subroute: 71),  Owner: County Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.4m (17.7ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Channel: Poor,  Culverts: Satisfactory,  Operating Rating: 85.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 12115,  Location: NORTHVILLE E/SHELDON (Lat: 42.425667,  Lng: -83.481056),  Route carried "on" structure: County highway 2057,  Year Built: 1932,  Year Reconstructed: 1978,  Status: Open,  Structure Length: 1.03m (3.38ft),  Average Daily Traffic: 10,904 (year 1996),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,666 (year 2015),  Design Load: HS 20+Mod,  Features Intersected: MIDDLE ROUGE RIVER,  Facility Carried by Structure: E N HINES DRIVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.932,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 470,  Subroute: 16),  Owner: County Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 16.1m (52.8ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 62.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 12116,  Location: NORTHVILLE N/MAIN ST (Lat: 42.432625,  Lng: -83.478867),  Route carried "on" structure: County highway 2057,  Year Built: 1928,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 5,403 (year 1993),  Truck Traffic: 2%,  Average Future Daily Traffic: 6,484 (year 2015),  Design Load: H 20,  Features Intersected: MIDDLE ROUGE RIVER,  Facility Carried by Structure: GRISWOLD STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.409,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 10.9m (35.8ft),  Out-to-Out Width: 19.0m (62.3ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 22.2 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 13.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: High priority of corrective action,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: 12117,  Location: NORTHVILLE S/BASE LINE (Lat: 42.435075,  Lng: -83.476178),  Route carried "on" structure: County highway 2057,  Year Built: 2001,  Status: Open,  Structure Length: 1.95m (6.40ft),  Average Daily Traffic: 9,704 (year 1999),  Truck Traffic: 1%,  Average Future Daily Traffic: 6,484 (year 2015),  Design Load: HS 25 or greater,  Features Intersected: CSX RR,  Facility Carried by Structure: GRISWOLD STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.810,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 77.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 12118,  Location: NORTHVILE N/SEVEN MILE (Lat: 42.430614,  Lng: -83.476025),  Route carried "on" structure: County highway 2057,  Year Built: 1928,  Status: Open,  Structure Length: 1.00m (3.28ft),  Average Daily Traffic: 12,382 (year 1997),  Truck Traffic: 3%,  Average Future Daily Traffic: 14,789 (year 2015),  Design Load: H 20,  Features Intersected: MIDDLE ROUGE RIVER,  Facility Carried by Structure: NORTHVILLE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.019,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.5m (14.8ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 0.0m,  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 23.7m (77.8ft)

Condition: Channel: Poor,  Culverts: Fair,  Operating Rating: 72.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: 12124,  Location: NORTHVILE T S/SIX MILE (Lat: 42.406578,  Lng: -83.469169),  Route carried "on" structure: County highway 2057,  Year Built: 1922,  Year Reconstructed: 1976,  Status: Open,  Structure Length: 1.95m (6.40ft),  Average Daily Traffic: 8,758 (year 1997),  Truck Traffic: 3%,  Average Future Daily Traffic: 7,484 (year 2015),  Design Load: HS 20,  Features Intersected: MIDDLE ROUGE RIVER,  Facility Carried by Structure: NORTHVILLE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.651,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 18.9m (62.0ft)

Condition: Deck: Poor,  Superstructure: Serious,  Substructure: Fair,  Channel: Fair,  Operating Rating: 56.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 12125,  Location: NORTHVILLE N OF SIX MILE (Lat: 42.413714,  Lng: -83.469956),  Route carried "on" structure: County highway 2057,  Year Built: 1922,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 1.95m (6.40ft),  Average Daily Traffic: 15,628 (year 1997),  Truck Traffic: 5%,  Average Future Daily Traffic: 11,583 (year 2015),  Design Load: H 20,  Features Intersected: MIDDLE ROUGE RIVER,  Facility Carried by Structure: NORTHVILLE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.451,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 18.9m (62.0ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 64.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 12126,  Location: NORTHVILE T S/SEVEN MILE (Lat: 42.420242,  Lng: -83.472994),  Route carried "on" structure: County highway 2057,  Year Built: 1959,  Status: Posted for load,  Structure Length: 2.77m (9.09ft),  Average Daily Traffic: 15,628 (year 1997),  Truck Traffic: 3%,  Average Future Daily Traffic: 11,583 (year 2015),  Design Load: HS 20,  Features Intersected: MIDDLE ROUGE RIVER,  Facility Carried by Structure: NORTHVILLE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.221,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 17.6m (57.7ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.6m (34.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 14.7m (48.2ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 46.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 27.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 12283,  Location: NORTHVILLE T S/SEVEN MILE (Lat: 42.420939,  Lng: -83.495517),  Route carried "on" structure: County highway ,  Year Built: 1965,  Status: Open,  Structure Length: 1.09m (3.58ft),  Average Daily Traffic: 300 (year 1987),  Truck Traffic: 1%,  Average Future Daily Traffic: 360 (year 2015),  Design Load: HS 20+Mod,  Features Intersected: JOHNSON DRAIN,  Facility Carried by Structure: EDENDERRY DRIVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.502,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.8m (38.7ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.1m (16.7ft),  Curb-To-Curb Width: 11.8m (38.7ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Channel: Serious,  Culverts: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 97.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 12284,  Location: NORTHVILLE T S/SEVEN MILE (Lat: 42.423422,  Lng: -83.475628),  Route carried "on" structure: County highway ,  Year Built: 1945,  Status: Closed,  Structure Length: 1.03m (3.38ft),  Average Daily Traffic: 400 (year 1987),  Average Future Daily Traffic: 480 (year 2015),  Design Load: H 20,  Features Intersected: MIDDLE ROUGE RIVER,  Facility Carried by Structure: NORTHVILLE PARK DR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.412,  Lanes on structure: 2,  Owner: Local Agency,  Maintenance Responsibility: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 8.3m (27.2ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Channel: Poor,  Operating Rating: 10.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 6.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: High priority of replacement,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 1251,  Location: 0.01 MI W OF RIVER STREET (Lat: 42.428908,  Lng: -83.478200),  Route carried "on" structure: City street ,  Year Built: 2008,  Status: Open,  Structure Length: 0.92m (3.02ft),  Average Daily Traffic: 10 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,300 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: MIDDLE RIVER ROUGE,  Facility Carried by Structure: BEAL STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.035,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 12511,  Location: 0.1 MI S OF FAIRBROOK ST (Lat: 42.425303,  Lng: -83.488939),  Route carried "on" structure: City street ,  Year Built: 1973,  Status: Open,  Structure Length: 1.03m (3.38ft),  Average Daily Traffic: 10 (year 1989),  Truck Traffic: 3%,  Average Future Daily Traffic: 10 (year 2013),  Design Load: HS 20,  Features Intersected: JOHNSON DRAIN,  Facility Carried by Structure: RURAL HILL DRIVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.171,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 54.6 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.04m (3.41ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Bridge Improvement Cost: $240,000,  Roadway Improvement Cost: $18,000,  Total Project Cost: $360,000,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 12087,  Location: NORTHVILLE T W/NORTHV RD (Lat: 42.410653,  Lng: -83.471922),  Route carried "under" structure: County highway ,  Year Built: 1933,  Structure Length: 0. m,  Average Daily Traffic: 1,959 (year 1992),  Features Intersected: EN HINES DRIVE,  Facility Carried by Structure: SIX MILE ROAD
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 2.644,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete,  Design/Construction: Frame,  Length of Maximum Span: 18.2m (59.7ft)

Find on map >>   Show street view

Structure Number: 12088,  Location: NORTHVILLE T E/NORTHV RD (Lat: 42.411486,  Lng: -83.468675),  Route carried "under" structure: County highway 2057,  Year Built: 1933,  Structure Length: 0. m,  Average Daily Traffic: 16,266 (year 1997),  Truck Traffic: 5%,  Features Intersected: SIX MILE ROAD,  Facility Carried by Structure: CSX RR
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 6.753,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 20.1m (65.9ft)

Find on map >>   Show street view

Structure Number: 121,  Location: NORTHVILLE W/CENTER (Lat: 42.439233,  Lng: -83.487900),  Route carried "under" structure: County highway 2057,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 12,569 (year 1996),  Truck Traffic: 8%,  Features Intersected: BASE LINE,  Facility Carried by Structure: PEDESTRIAN WALKWAY
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 0.425,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Discuss Northville, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.