Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Wyoming, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 63Number of bridges
  • 614ft / 187mTotal length
  • $240,000Total costs
  • 1,594,813Total average daily traffic
  • 100,539Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Wyoming
  • No street view available for this location

New bridges in Wyoming, MI - historical statistics
  • New bridges - historical statistics
  • 11910-1919
  • 11930-1939
  • 41950-1959
  • 81960-1969
  • 91970-1979
  • 81980-1989
  • 31990-1999
  • 262000-2009
  • 32010-2019
Reconstructed bridges in Wyoming, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11980-1989
  • 21990-1999
  • 22000-2009
  • 22010-2019
Average Bridge Daily Traffic in Wyoming, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 4.9%Very good
  • 68.3%Good
  • 22.0%Satisfactory
  • 4.9%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 31.0%Very good
  • 31.0%Good
  • 21.4%Satisfactory
  • 11.9%Fair
  • 4.8%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 7.1%Very good
  • 54.8%Good
  • 26.2%Satisfactory
  • 11.9%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 3.3%Excellent
  • 26.7%Very good
  • 43.3%Good
  • 10.0%Satisfactory
  • 10.0%Fair
  • 6.7%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 25.0%Very good
  • 25.0%Good
  • 25.0%Satisfactory
  • 25.0%Poor
Find on map >>   Show street view

Structure Number: 525,  Location: 3 MI S OF THREE LAKES (Lat: 46.507017,  Lng: -88.179814),  Route carried "on" structure: County highway ,  Year Built: 1993,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 28 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 300 (year 2035),  Design Load: HS 20,  Features Intersected: SPRUCE RIVER,  Facility Carried by Structure: FENCE LAKE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.259,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.6m (34.8ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 71.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Other
Find on map >>   Show street view

Structure Number: 4805,  Location: IN WYOMING (Lat: 42.928786,  Lng: -85.731844),  Route carried "on" structure: Ramp Interstate 196,  Year Built: 1965,  Status: Open,  Structure Length: 6.64m (21.78ft),  Average Daily Traffic: 6,208 (year 2007),  Truck Traffic: 11%,  Average Future Daily Traffic: 6,782 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: CSX RR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.478,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.3m (69.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 56.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 4806,  Location: IN WYOMING (Lat: 42.934431,  Lng: -85.722958),  Route carried "on" structure: Interstate 196,  Year Built: 1963,  Status: Open,  Structure Length: 9.23m (30.28ft),  Average Daily Traffic: 53,075 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 61,650 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: CONRAIL (NO TRACKS)(ABN)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 9.048,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 40,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 6 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 31.8m (104.3ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 91.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 54.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 4807,  Location: IN WYOMING (Lat: 42.934958,  Lng: -85.722747),  Route carried "on" structure: Interstate 196,  Year Built: 1963,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 9.66m (31.69ft),  Average Daily Traffic: 57,075 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 61,650 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: CONRAIL (NO TRACKS)(ABN)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 9.162,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 40,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 6 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.8m (107.6ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 65.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4817,  Location: IN WYOMING (I-196 EB) (Lat: 42.930611,  Lng: -85.734094),  Route carried "on" structure: ServiceState highway 21,  Year Built: 1965,  Status: Open,  Structure Length: 4.87m (15.98ft),  Average Daily Traffic: 6,208 (year 2007),  Truck Traffic: 11%,  Average Future Daily Traffic: 6,782 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: I-196 EB
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.401,  Lanes on structure: 1,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.6m (70.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 6.4m (21.0ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 56.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $59,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 4818,  Location: IN WYOMING (Lat: 42.927311,  Lng: -85.730247),  Route carried "on" structure: Ramp Interstate 196,  Year Built: 1965,  Status: Open,  Structure Length: 4.36m (14.30ft),  Average Daily Traffic: 6,208 (year 2007),  Truck Traffic: 11%,  Average Future Daily Traffic: 7,139 (year 2008),  Design Load: HS 20+Mod,  Features Intersected: M-21BR (CHICAGO DRIVE)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.682,  Lanes on structure: 2,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.6m (70.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 6.4m (21.0ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 50.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 4835,  Location: W LTS OF WYOMING (Lat: 42.877419,  Lng: -85.782272),  Route carried "on" structure: City street 2001,  Year Built: 1972,  Year Reconstructed: 2013,  Status: Open,  Structure Length: 10.79m (35.40ft),  Average Daily Traffic: 5,443 (year 1997),  Truck Traffic: 1%,  Average Future Daily Traffic: 250 (year 1977),  Design Load: H 20,  Features Intersected: I-196,  Facility Carried by Structure: KENOWA AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.210,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 36.9m (121.1ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 71.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4853,  Location: IN WYOMING (Lat: 42.935819,  Lng: -85.687592),  Route carried "on" structure: Business State highway 21,  Year Built: 1916,  Status: Open,  Structure Length: 1.82m (5.97ft),  Average Daily Traffic: 16,531 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 18,421 (year 2018),  Design Load: H 20,  Features Intersected: PLASTER CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.766,  Lanes on structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.2m (59.7ft),  Curb or Sidewalk Widths: Left: 3.3m (10.8ft),  Right: 3.3m (10.8ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 89.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 53.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: 4866,  Location: IN WYOMING (Lat: 42.913217,  Lng: -85.675897),  Route carried "on" structure: State highway 11,  Year Built: 1937,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 5.18m (16.99ft),  Average Daily Traffic: 37,247 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 50,591 (year 2018),  Design Load: HS 20,  Features Intersected: CONRAIL
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 18.128,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 40,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Skew: 21 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.2m (59.7ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 19.2m (63.0ft),  Out-to-Out Width: 22.9m (75.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 64.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4941,  Location: IN WYOMING (Lat: 42.868417,  Lng: -85.679769),  Route carried "on" structure: US 131,  Year Built: 2000,  Status: Open,  Structure Length: 1.70m (5.58ft),  Average Daily Traffic: 38,681 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 39,400 (year 2015),  Design Load: HS 25 or greater,  Features Intersected: BUCK CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.282,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 41,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 24.6m (80.7ft),  Out-to-Out Width: 25.1m (82.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 57.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4942,  Location: IN WYOMING (Lat: 42.868350,  Lng: -85.680144),  Route carried "on" structure: US 131,  Year Built: 2000,  Status: Open,  Structure Length: 1.71m (5.61ft),  Average Daily Traffic: 38,681 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 43,973 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: BUCK CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.287,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 41,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.1m (56.1ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 24.1m (79.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 89.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4943,  Location: IN WYOMING @ 54 TH (Lat: 42.868181,  Lng: -85.681058),  Route carried "on" structure: Ramp US 131,  Year Built: 1985,  Status: Open,  Structure Length: 4.97m (16.31ft),  Average Daily Traffic: 3,000 (year 1988),  Truck Traffic: 3%,  Average Future Daily Traffic: 3,450 (year 2008),  Design Load: HS 25 or greater,  Features Intersected: BUCK CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.277,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 32.9m (107.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 62.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4966,  Location: IN WYOMING (Lat: 42.866039,  Lng: -85.679456),  Route carried "on" structure: City street 2001,  Year Built: 1985,  Status: Open,  Structure Length: 6.12m (20.08ft),  Average Daily Traffic: 34,000 (year 2013),  Truck Traffic: 4%,  Average Future Daily Traffic: 39,100 (year 2033),  Design Load: HS 20,  Features Intersected: US-131,  Facility Carried by Structure: 54TH ST
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.362,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 41,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.4m (103.0ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 17.4m (57.1ft),  Out-to-Out Width: 26.9m (88.3ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 42.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4967,  Location: IN WYOMING (Lat: 42.884192,  Lng: -85.680617),  Route carried "on" structure: City street 2001,  Year Built: 2008,  Status: Open,  Structure Length: 4.16m (13.65ft),  Average Daily Traffic: 50,697 (year 1997),  Truck Traffic: 5%,  Average Future Daily Traffic: 60,000 (year 2020),  Design Load: HL 93,  Features Intersected: US-131,  Facility Carried by Structure: 44TH ST
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.055,  Lanes on structure: 6,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 341,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 30.4m (99.7ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 20.1m (65.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 33.4m (109.6ft),  Out-to-Out Width: 36.6m (120.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 61.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4968,  Location: IN WYOMING (Lat: 42.898717,  Lng: -85.677778),  Route carried "on" structure: City street 2001,  Year Built: 2011,  Status: Open,  Structure Length: 4.28m (14.04ft),  Average Daily Traffic: 32,736 (year 1997),  Truck Traffic: 1%,  Average Future Daily Traffic: 28,000 (year 2031),  Design Load: HL 93,  Features Intersected: US-131,  Facility Carried by Structure: 36TH ST
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.606,  Lanes on structure: 6,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 21.6m (70.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 20.8m (68.2ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 21.3m (69.9ft),  Out-to-Out Width: 27.2m (89.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 64.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 44.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4969,  Location: IN WYOMING (Lat: 42.905983,  Lng: -85.676983),  Route carried "on" structure: City street 2001,  Year Built: 1958,  Year Reconstructed: 1993,  Status: Open,  Structure Length: 6.49m (21.29ft),  Average Daily Traffic: 16,925 (year 1997),  Truck Traffic: 1%,  Average Future Daily Traffic: 25,000 (year 2020),  Design Load: HS 20,  Features Intersected: US-131,  Facility Carried by Structure: 32ND ST
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.485,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.2m (59.7ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 18.7m (61.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 68.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 497,  Location: IN WYOMING (Lat: 42.913253,  Lng: -85.677533),  Route carried "on" structure: State highway 11,  Year Built: 2004,  Status: Open,  Structure Length: 4.66m (15.29ft),  Average Daily Traffic: 44,816 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 50,591 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: US-131
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 18.000,  Lanes on structure: 5,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 40,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Skew: 21 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.3m (76.4ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 25.1m (82.3ft),  Out-to-Out Width: 28.6m (93.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 98.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5125,  Location: 0.20 MI S OF 60TH ST (Lat: 42.853381,  Lng: -85.782175),  Route carried "on" structure: County highway ,  Year Built: 2010,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 2,704 (year 2003),  Average Future Daily Traffic: 4,600 (year 2023),  Design Load: HS 20+Mod,  Features Intersected: RUSH CREEK,  Facility Carried by Structure: KENOWA AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.579,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 34.1m (111.9ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 51.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 5242,  Location: IN WYOMING (Lat: 42.890833,  Lng: -85.724331),  Route carried "on" structure: City street 2001,  Year Built: 1986,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 21,839 (year 2009),  Truck Traffic: 7%,  Average Future Daily Traffic: 29,414 (year 2029),  Design Load: HS 20,  Features Intersected: BUCK CREEK,  Facility Carried by Structure: BYRON CENTER AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 13.622,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.7m (31.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 28.0m (91.9ft)

Condition: Channel: Fair,  Culverts: Very good,  Operating Rating: 43.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5245,  Location: 200 FT N OF 56TH ST (Lat: 42.863700,  Lng: -85.676053),  Route carried "on" structure: City street ,  Year Built: 2000,  Status: Open,  Structure Length: 2.00m (6.56ft),  Average Daily Traffic: 6,793 (year 2009),  Truck Traffic: 9%,  Average Future Daily Traffic: 9,149 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: BUCK CREEK,  Facility Carried by Structure: CLAY AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.959,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.0m (65.6ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 78.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5246,  Location: 200 FT S OF 44TH ST (Lat: 42.883703,  Lng: -85.705339),  Route carried "on" structure: City street 2001,  Year Built: 1979,  Year Reconstructed: 2013,  Status: Open,  Structure Length: 2.10m (6.89ft),  Average Daily Traffic: 12,559 (year 2009),  Truck Traffic: 1%,  Average Future Daily Traffic: 16,915 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: BUCK CREEK,  Facility Carried by Structure: BURLINGAME AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 12.845,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 19.8m (65.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.6m (67.6ft),  Curb or Sidewalk Widths: Left: 2.5m (8.2ft),  Right: 2.5m (8.2ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 25.1m (82.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 80.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5247,  Location: IN WYOMING (Lat: 42.937575,  Lng: -85.690156),  Route carried "on" structure: City street 2001,  Year Built: 1956,  Status: Open,  Structure Length: 1.87m (6.14ft),  Average Daily Traffic: 5,129 (year 2008),  Truck Traffic: 9%,  Average Future Daily Traffic: 6,908 (year 2028),  Design Load: HS 20+Mod,  Features Intersected: PLASTER CREEK,  Facility Carried by Structure: GODFREY AVENUE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.225,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.7m (58.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 13.7m (44.9ft),  Out-to-Out Width: 17.2m (56.4ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Fair,  Channel: Poor,  Operating Rating: 58.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.07m (6.79ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Bridge Improvement Cost: $210,000,  Roadway Improvement Cost: $30,000,  Total Project Cost: $240,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5248,  Location: IN WYOMING (Lat: 42.870644,  Lng: -85.684039),  Route carried "on" structure: City street 2001,  Year Built: 1990,  Status: Open,  Structure Length: 1.89m (6.20ft),  Average Daily Traffic: 14,442 (year 2009),  Truck Traffic: 11%,  Average Future Daily Traffic: 19,451 (year 2029),  Design Load: HS 20,  Features Intersected: BUCK CREEK,  Facility Carried by Structure: CLYDE PARK AVENUE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.380,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.9m (62.0ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 27.1m (88.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 63.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5249,  Location: IN WYOMING AND GRAND RAPI (Lat: 42.929097,  Lng: -85.686292),  Route carried "on" structure: City street 2001,  Year Built: 1994,  Status: Open,  Structure Length: 2.25m (7.38ft),  Average Daily Traffic: 18,084 (year 2009),  Truck Traffic: 10%,  Average Future Daily Traffic: 24,357 (year 2029),  Design Load: HS 25 or greater,  Features Intersected: PLASTER CREEK,  Facility Carried by Structure: CLYDE PARK AVENUE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 17.876,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.5m (73.8ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 3.7m (12.1ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Inventory Rating: 62.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 525,  Location: IN WYOMING (Lat: 42.918344,  Lng: -85.671150),  Route carried "on" structure: City street 2001,  Year Built: 1958,  Status: Open,  Structure Length: 1.85m (6.07ft),  Average Daily Traffic: 12,915 (year 2009),  Truck Traffic: 9%,  Average Future Daily Traffic: 17,395 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: PLASTER CREEK,  Facility Carried by Structure: BUCHANAN AVENUE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.263,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.5m (57.4ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 65.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5251,  Location: IN WYOMING (Lat: 42.865989,  Lng: -85.677142),  Route carried "on" structure: City street 2001,  Year Built: 1986,  Year Reconstructed: 2019,  Status: Open,  Structure Length: 2.13m (6.99ft),  Average Daily Traffic: 27,800 (year 2018),  Truck Traffic: 10%,  Average Future Daily Traffic: 50,000 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: BUCK CREEK,  Facility Carried by Structure: 54TH STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.550,  Lanes on structure: 6,  Base Highway Network: Yes (Inventory Route: 41,  Subroute: 9),  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 21.6m (70.9ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.3m (66.6ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 22.6m (74.1ft),  Out-to-Out Width: 30.9m (101.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 65.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 49.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5252,  Location: IN WYOMING (Lat: 42.884431,  Lng: -85.706300),  Route carried "on" structure: City street 2001,  Year Built: 1976,  Status: Open,  Structure Length: 1.79m (5.87ft),  Average Daily Traffic: 27,397 (year 2009),  Truck Traffic: 8%,  Average Future Daily Traffic: 36,900 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: BUCK CREEK,  Facility Carried by Structure: 44TH STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.356,  Lanes on structure: 5,  Base Highway Network: Yes (Inventory Route: 341,  Subroute: 84),  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 22.0m (72.2ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 30.1m (98.8ft)

Condition: Channel: Poor,  Culverts: Poor,  Operating Rating: 28.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 16.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8744,  Location: 1 MI W OF KENT CO LINE (Lat: 42.865936,  Lng: -85.801875),  Route carried "on" structure: County highway ,  Year Built: 1972,  Status: Open,  Structure Length: 8.50m (27.89ft),  Average Daily Traffic: 3,100 (year 1996),  Truck Traffic: 3%,  Average Future Daily Traffic: 3,565 (year 2016),  Design Load: H 20,  Features Intersected: I-196,  Facility Carried by Structure: 8TH AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.881,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 30.7m (100.7ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 70.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 8815,  Location: 0.15 MI E OF 8TH AVE (Lat: 42.847983,  Lng: -85.794661),  Route carried "on" structure: County highway 7018,  Year Built: 2002,  Status: Open,  Structure Length: 1.80m (5.91ft),  Average Daily Traffic: 800 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,440 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: EAST BR OF RUSH CREEK,  Facility Carried by Structure: RANSOM STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.676,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 14.3m (46.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 71.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 888,  Location: SECTION 36 GEORGETOWN TWP (Lat: 42.856314,  Lng: -85.787403),  Route carried "on" structure: County highway ,  Year Built: 1970,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 868 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,570 (year 2039),  Design Load: H 20,  Features Intersected: E BRANCH RUSH CREEK,  Facility Carried by Structure: JACKSON ST
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.127,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 36.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 27.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 8881,  Location: SEC 36 GEORGETOWN TWP (Lat: 42.863533,  Lng: -85.788414),  Route carried "on" structure: County highway ,  Year Built: 1972,  Year Reconstructed: 2019,  Status: Open,  Structure Length: 1.62m (5.31ft),  Average Daily Traffic: 3,470 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,270 (year 2040),  Design Load: Greater than HL93,  Features Intersected: E BRANCH RUSH CREEK,  Facility Carried by Structure: BARRY STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.098,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 77.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8894,  Location: SECTION 11 JAMESTOWN TWP (Lat: 42.840686,  Lng: -85.810939),  Route carried "on" structure: County highway ,  Year Built: 1969,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 2,712 (year 2014),  Average Future Daily Traffic: 4,900 (year 2034),  Design Load: HS 20+Mod,  Features Intersected: EAST BRANCH RUSH CREEK,  Facility Carried by Structure: QUINCY STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.335,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Wood or Timber,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.1m (6.9ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 49.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8895,  Location: SECTION 12 JAMESTOWN TWP (Lat: 42.840697,  Lng: -85.793375),  Route carried "on" structure: County highway ,  Year Built: 1976,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 210 (year 2020),  Average Future Daily Traffic: 380 (year 2040),  Design Load: H 20,  Features Intersected: MILLER CREEK,  Facility Carried by Structure: QUINCY ST
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.770,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.9m (25.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 12912,  Location: BYRON TWP SEC 4-5 (Lat: 42.852772,  Lng: -85.742742),  Route carried "on" structure: County highway ,  Year Built: 2001,  Status: Open,  Structure Length: 7.77m (25.49ft),  Average Daily Traffic: 2,800 (year 2000),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,300 (year 2015),  Design Load: HS 20,  Features Intersected: M-6,  Facility Carried by Structure: IVANREST AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.858,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 14.4m (47.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 39.9m (130.9ft),  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 81.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 13016,  Location: JAMESTOWN TWP SEC 1-2 (Lat: 42.846108,  Lng: -85.799631),  Route carried "on" structure: State highway 6,  Year Built: 2002,  Status: Open,  Structure Length: 2.72m (8.92ft),  Average Daily Traffic: 17,279 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 19,800 (year 2015),  Design Load: HS 25 or greater,  Features Intersected: RUSH CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.452,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 370,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 27.2m (89.2ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 65.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 13017,  Location: JAMESTOWN TWP SEC 1-2 (Lat: 42.845831,  Lng: -85.799689),  Route carried "on" structure: State highway 6,  Year Built: 2002,  Status: Open,  Structure Length: 2.72m (8.92ft),  Average Daily Traffic: 17,279 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 25,500 (year 2015),  Design Load: HS 25 or greater,  Features Intersected: RUSH CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.005,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 370,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 27.2m (89.2ft),  Curb-To-Curb Width: 16.8m (55.1ft),  Out-to-Out Width: 17.9m (58.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 65.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 13024,  Location: JAMESTOWN TWP SEC 1-2 (Lat: 42.846600,  Lng: -85.802158),  Route carried "on" structure: County highway ,  Year Built: 2002,  Status: Open,  Structure Length: 12.88m (42.26ft),  Average Daily Traffic: 11,800 (year 2003),  Truck Traffic: 8%,  Average Future Daily Traffic: 11,800 (year 2015),  Design Load: HS 25 or greater,  Features Intersected: M-6, RUSH CREEK,  Facility Carried by Structure: 8TH AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.700,  Lanes on structure: 5,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 24.0m (78.7ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 50.1m (164.4ft),  Curb-To-Curb Width: 26.2m (86.0ft),  Out-to-Out Width: 27.2m (89.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 74.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 13025,  Location: JAMESTOWN TWP SEC 1 (Lat: 42.847947,  Lng: -85.799022),  Route carried "on" structure: Ramp State highway 6,  Year Built: 2002,  Status: Open,  Structure Length: 4.24m (13.91ft),  Average Daily Traffic: 9,300 (year 2003),  Truck Traffic: 8%,  Average Future Daily Traffic: 9,300 (year 2015),  Design Load: HS 25 or greater,  Features Intersected: RUSH CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.558,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 42.4m (139.1ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 75.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 54.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 13026,  Location: JAMESTOWN TWP SEC 2 (Lat: 42.845022,  Lng: -85.804381),  Route carried "on" structure: Ramp State highway 6,  Year Built: 2002,  Status: Open,  Structure Length: 2.32m (7.61ft),  Average Daily Traffic: 900 (year 2002),  Truck Traffic: 8%,  Average Future Daily Traffic: 900 (year 2015),  Design Load: HS 25 or greater,  Features Intersected: RUSH CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.584,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 23.2m (76.1ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 70.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Discuss Wyoming, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.