Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Sparks, Nevada (NV)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 91Number of bridges
  • 1,220ft / 372mTotal length
  • $17,871,000Total costs
  • 1,721,518Total average daily traffic
  • 159,712Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Sparks
  • No street view available for this location

New bridges in Sparks, NV - historical statistics
  • New bridges - historical statistics
  • 51950-1959
  • 241960-1969
  • 61970-1979
  • 171980-1989
  • 161990-1999
  • 142000-2009
  • 92010-2019
Reconstructed bridges in Sparks, NV - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21970-1979
  • 31980-1989
  • 11990-1999
Average Bridge Daily Traffic in Sparks, NV
Average Bridge Truck Traffic in Sparks, NV
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 53.5%Good
  • 41.9%Satisfactory
  • 4.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 18.8%Very good
  • 41.7%Good
  • 22.9%Satisfactory
  • 10.4%Fair
  • 6.3%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 8.3%Very good
  • 75.0%Good
  • 12.5%Satisfactory
  • 4.2%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 31.0%Very good
  • 33.3%Good
  • 23.8%Satisfactory
  • 7.1%Fair
  • 4.8%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 4.2%Very good
  • 66.7%Good
  • 29.2%Satisfactory
Find on map >>   Show street view

Structure Number: B 12,  Location: SPARKS (Lat: 39.527878,  Lng: -119.709694),  Route carried "on" structure: Interstate 80,  Year Built: 1953,  Year Reconstructed: 1989,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 50,000 (year 2017),  Truck Traffic: 19%,  Average Future Daily Traffic: 75,800 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NORTH TRUCKEE DRAIN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 30.896,  Lanes on structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 32.9m (107.9ft),  Skew: 30 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 51.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: B 65,  Location: EAST OF RENO (Lat: 39.564872,  Lng: -119.486642),  Route carried "on" structure: ServiceOther road 416,  Year Built: 1957,  Status: Open,  Structure Length: 6.49m (21.29ft),  Average Daily Traffic: 180 (year 2017),  Truck Traffic: 25%,  Average Future Daily Traffic: 447 (year 2040),  Design Load: HS 20,  Features Intersected: TRUCKEE RVR,  Facility Carried by Structure: FR WA16
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 26.5m (86.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 67.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: May 2021,  Underwater Inspection Date: August 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: B 815,  Location: SPARKS (Lat: 39.562858,  Lng: -119.749925),  Route carried "on" structure: City street 669,  Year Built: 1959,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 47,000 (year 2017),  Truck Traffic: 4%,  Average Future Daily Traffic: 68,500 (year 2040),  Design Load: HS 20,  Features Intersected: ORR DITCH,  Facility Carried by Structure: SR 445/PYRAMID L.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.248,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.4m (70.2ft),  Skew: 25 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.4m (21.0ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 76.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: B13,  Location: SPARKS (Lat: 39.517400,  Lng: -119.740861),  Route carried "on" structure: City street 659,  Year Built: 1971,  Status: Open,  Structure Length: 6.89m (22.60ft),  Average Daily Traffic: 26,000 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 64,529 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: TRUCKEE RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.062,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.9m (75.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 0.0m,  Curb-To-Curb Width: 24.4m (80.1ft),  Out-to-Out Width: 26.5m (86.9ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 65.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: April 2020,  Underwater Inspection Date: August 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: B1424,  Location: SPARKS (Lat: 39.493703,  Lng: -119.748108),  Route carried "on" structure: City street 659,  Year Built: 1981,  Status: Open,  Structure Length: 2.13m (6.99ft),  Average Daily Traffic: 19,000 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 47,156 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BOYNTON SLOUGH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 21 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 3.7m (12.1ft),  Curb-To-Curb Width: 21.3m (69.9ft),  Out-to-Out Width: 30.2m (99.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 85.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2018
Find on map >>   Show street view

Structure Number: B1427,  Location: LOCKWOOD (Lat: 39.507167,  Lng: -119.646447),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Posted for load,  Structure Length: 1.20m (3.94ft),  Average Daily Traffic: 1,000 (year 2017),  Average Future Daily Traffic: 2,482 (year 2040),  Features Intersected: LOUSETOWN CRK,  Facility Carried by Structure: COUNTY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.0m (39.4ft),  Curb-To-Curb Width: 6.0m (19.7ft),  Out-to-Out Width: 6.5m (21.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Poor,  Operating Rating: 20.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 12.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of corrective action,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Length Of Structure Improvement: 0.68m (2.23ft),  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Critical Feature Inspection Date: May 2021,  Bridge Improvement Cost: $124,000,  Roadway Improvement Cost: $12,000,  Total Project Cost: $186,000,  Deck Structure Type: Steel plate,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: B149,  Location: EAST OF SPARKS (Lat: 39.509856,  Lng: -119.648825),  Route carried "on" structure: ServiceOther road ,  Year Built: 1976,  Status: Open,  Structure Length: 5.61m (18.41ft),  Average Daily Traffic: 2,900 (year 2017),  Truck Traffic: 40%,  Average Future Daily Traffic: 7,198 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: TRUCKEE RVR,  Facility Carried by Structure: CANYON RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.1m (49.5ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 52.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.76m (2.49ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: May 2021,  Underwater Inspection Date: August 2019,  Bridge Improvement Cost: $823,000,  Roadway Improvement Cost: $82,000,  Total Project Cost: $950,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: B1523,  Location: SPARKS (Lat: 39.527628,  Lng: -119.778078),  Route carried "on" structure: City street 648,  Year Built: 1977,  Status: Open,  Structure Length: 11.92m (39.11ft),  Average Daily Traffic: 16,500 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 40,951 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: TRUCKEE RVR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.613,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 48.8m (160.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 26.8m (87.9ft),  Out-to-Out Width: 31.4m (103.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 71.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Bridge Improvement Cost: $3,290,000,  Roadway Improvement Cost: $329,000,  Total Project Cost: $4,935,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B1534,  Location: SPARKS (Lat: 39.518431,  Lng: -119.761303),  Route carried "on" structure: City street 668,  Year Built: 1971,  Status: Open,  Structure Length: 9.02m (29.59ft),  Average Daily Traffic: 5,700 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 14,147 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: TRUCKEE RVR,  Facility Carried by Structure: ROCK BL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 42.7m (140.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.9m (62.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: B17,  Location: SOUTHEAST OF SPARKS (Lat: 39.513019,  Lng: -119.712303),  Route carried "on" structure: County highway ,  Year Built: 1964,  Status: Open,  Structure Length: 2.19m (7.19ft),  Average Daily Traffic: 1,188 (year 2017),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,948 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: STEAMBOAT CREEK,  Facility Carried by Structure: CLEAN WATER WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 68.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.99m (9.81ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2018,  Bridge Improvement Cost: $240,000,  Roadway Improvement Cost: $24,000,  Total Project Cost: $360,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: B1716,  Location: SPARKS (Lat: 39.521781,  Lng: -119.771294),  Route carried "on" structure: City street 667,  Year Built: 1980,  Status: Open,  Structure Length: 7.32m (24.02ft),  Average Daily Traffic: 11,000 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 27,301 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: TRUCKEE RIVER,  Facility Carried by Structure: GREG ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 30.5m (100.1ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 15.5m (50.9ft),  Out-to-Out Width: 16.5m (54.1ft)

Condition: Deck: Good,  Superstructure: Poor,  Substructure: Good,  Channel: Good,  Operating Rating: 67.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Other Special Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: B1819,  Location: NORTHEASTERN SPARKS (Lat: 39.556361,  Lng: -119.724703),  Route carried "on" structure: Business City street 674,  Year Built: 1972,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 28,500 (year 2017),  Truck Traffic: 4%,  Average Future Daily Traffic: 70,734 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: N TRUCKEE DRAIN,  Facility Carried by Structure: BARING BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 18.6m (61.0ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 33.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: B182,  Location: NORTHEASTERN SPARKS (Lat: 39.551408,  Lng: -119.718822),  Route carried "on" structure: Business City street ,  Year Built: 1985,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 10,560 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 33,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NORTH TRUCKEE DRAIN,  Facility Carried by Structure: SPRINGLAND DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb-To-Curb Width: 21.3m (69.9ft),  Out-to-Out Width: 24.4m (80.1ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 90.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 90.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2018
Find on map >>   Show street view

Structure Number: B1821,  Location: NORTHEASTERN SPARKS (Lat: 39.541983,  Lng: -119.714931),  Route carried "on" structure: Business City street 646,  Year Built: 1981,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 10,500 (year 2017),  Truck Traffic: 4%,  Average Future Daily Traffic: 26,060 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NORTH TRUCKEE DRAIN,  Facility Carried by Structure: PRATER WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 22.9m (75.1ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft),  Curb-To-Curb Width: 31.4m (103.0ft),  Out-to-Out Width: 36.6m (120.1ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 61.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2018
Find on map >>   Show street view

Structure Number: B1822,  Location: EASTERN SPARKS (Lat: 39.533661,  Lng: -119.714936),  Route carried "on" structure: Business City street ,  Year Built: 1981,  Status: Open,  Structure Length: 1.03m (3.38ft),  Average Daily Traffic: 3,900 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 12,800 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NORTH TRUCKEE DRAIN,  Facility Carried by Structure: EAST LINCOLN WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 61.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2018
Find on map >>   Show street view

Structure Number: B1825,  Location: NORTHEASTERN SPARKS (Lat: 39.543592,  Lng: -119.715064),  Route carried "on" structure: Business City street 675,  Year Built: 1985,  Status: Open,  Structure Length: 1.43m (4.69ft),  Average Daily Traffic: 27,000 (year 2017),  Truck Traffic: 4%,  Average Future Daily Traffic: 67,011 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NORTH TRUCKEE DRAIN,  Facility Carried by Structure: SPARK BL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.7m (25.3ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 5.2m (17.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 62.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2018
Find on map >>   Show street view

Structure Number: B1849,  Location: EAST OF RENO (Lat: 39.511667,  Lng: -119.644639),  Route carried "on" structure: Other road ,  Year Built: 1995,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 139 (year 2017),  Truck Traffic: 2%,  Average Future Daily Traffic: 345 (year 2040),  Design Load: HS 20,  Features Intersected: LOUSETOWN CRK,  Facility Carried by Structure: AVE DE COULEURS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Local Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Poor,  Channel: Poor,  Operating Rating: 35.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Critical Feature Inspection Date: May 2021,  Other Special Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: B186,  Location: SPARKS (Lat: 39.566289,  Lng: -119.725583),  Route carried "on" structure: City street ,  Year Built: 1984,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 1,430 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 3,549 (year 2040),  Design Load: HS 20,  Features Intersected: NORTH TRUCKEE DRAIN,  Facility Carried by Structure: VINTAGEHILLS PKW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 90.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 90.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2018
Find on map >>   Show street view

Structure Number: B1862,  Location: SPARKS BLVD INTERCHANGE (Lat: 39.529153,  Lng: -119.711189),  Route carried "on" structure: Ramp Interstate 80,  Year Built: 1989,  Status: Open,  Structure Length: 0.81m (2.66ft),  Average Daily Traffic: 2,700 (year 2017),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,701 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: N TRUCKEE DRAIN OVERFLOW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 90.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 90.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2018
Find on map >>   Show street view

Structure Number: B1898,  Location: SPARKS (Lat: 39.563536,  Lng: -119.724981),  Route carried "on" structure: City street 677,  Year Built: 1990,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 2,900 (year 2017),  Truck Traffic: 1%,  Average Future Daily Traffic: 7,198 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NORTH TRUCKEE DRAIN,  Facility Carried by Structure: SHADOWBROOK LN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 0.1m (0.3ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 62.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2018
Find on map >>   Show street view

Structure Number: B2152,  Location: EAST OF RENO (PATRICK) (Lat: 39.556411,  Lng: -119.552825),  Route carried "on" structure: State highway 655,  Year Built: 1996,  Status: Open,  Structure Length: 5.39m (17.68ft),  Average Daily Traffic: 1,700 (year 2017),  Average Future Daily Traffic: 4,219 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: TRUCKEE RVR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.738,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 53.6m (175.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.7m (44.9ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Inventory Rating: 68.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.42m (21.06ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $721,000,  Roadway Improvement Cost: $72,000,  Total Project Cost: $1,082,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: B2245,  Location: SPARK (Lat: 39.524867,  Lng: -119.705764),  Route carried "on" structure: City street ,  Year Built: 1995,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 182 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 452 (year 2040),  Design Load: HS 20,  Features Intersected: N TRUCKEE DRN,  Facility Carried by Structure: KLEPPE LN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.4m (40.7ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 15.4m (50.5ft),  Out-to-Out Width: 19.8m (65.0ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 80.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2018
Find on map >>   Show street view

Structure Number: B2444,  Location: LAGO MARSINO CYN (Lat: 39.506097,  Lng: -119.646553),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 50 (year 2017),  Truck Traffic: 90%,  Average Future Daily Traffic: 60 (year 2040),  Features Intersected: LONG VALLEY CRK,  Facility Carried by Structure: CONNECT DIV FOREST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Satisfactory,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 36.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Critical Feature Inspection Date: May 2021,  Deck Structure Type: Steel plate,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: B2537,  Location: SPANISH SPRINGS (Lat: 39.661667,  Lng: -119.704417),  Route carried "on" structure: State highway 445,  Year Built: 2002,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 12,200 (year 2017),  Truck Traffic: 1%,  Average Future Daily Traffic: 25,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CHANNEL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.039,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 51.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: B2581,  Location: SPARKS (Lat: 39.568928,  Lng: -119.726361),  Route carried "on" structure: City street ,  Year Built: 1996,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 970 (year 2017),  Average Future Daily Traffic: 1,670 (year 2040),  Design Load: HS 20,  Features Intersected: N TRUCKEE DRN,  Facility Carried by Structure: SPANISH SPRINGS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.1m (26.6ft),  Skew: 6 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 2.5m (8.2ft),  Right: 0.0m

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 64.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2018
Find on map >>   Show street view

Structure Number: B2695,  Location: SPARKS (Lat: 39.599353,  Lng: -119.729247),  Route carried "on" structure: City street ,  Year Built: 1999,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 1,650 (year 2017),  Truck Traffic: 1%,  Average Future Daily Traffic: 4,095 (year 2040),  Design Load: HS 20,  Features Intersected: SUN VLY DVRSN,  Facility Carried by Structure: SPARKS BL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.1m (46.3ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 62.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: B2696,  Location: SPARKS (Lat: 39.534744,  Lng: -119.726764),  Route carried "on" structure: City street ,  Year Built: 2000,  Status: Open,  Structure Length: 0.77m (2.53ft),  Average Daily Traffic: 121 (year 2017),  Average Future Daily Traffic: 300 (year 2040),  Design Load: HS 20,  Features Intersected: CHANNEL,  Facility Carried by Structure: HARBOR COVE DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.9m (42.3ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.7m (25.3ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 12.9m (42.3ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 70.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: B2697,  Location: SPARKS (Lat: 39.564469,  Lng: -119.705261),  Route carried "on" structure: City street ,  Year Built: 2000,  Status: Open,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 6,800 (year 2017),  Truck Traffic: 1%,  Average Future Daily Traffic: 16,877 (year 2040),  Design Load: HS 20,  Features Intersected: CHANNEL,  Facility Carried by Structure: LOS ALTOS PW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 16.2m (53.1ft),  Skew: 22 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.0m (6.6ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 62.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2018
Find on map >>   Show street view

Structure Number: B2712,  Location: SPARKS (Lat: 39.572119,  Lng: -119.693978),  Route carried "on" structure: City street ,  Year Built: 1998,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 1,600 (year 2017),  Truck Traffic: 1%,  Average Future Daily Traffic: 3,971 (year 2040),  Design Load: HS 20,  Features Intersected: CHANNEL,  Facility Carried by Structure: LOS ALTOS PW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.8m (48.6ft),  Skew: 25 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.4m (11.2ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.6m (5.2ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2018
Find on map >>   Show street view

Structure Number: B2717,  Location: SPARKS (Lat: 39.589994,  Lng: -119.728831),  Route carried "on" structure: City street ,  Year Built: 2001,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 1,760 (year 2017),  Truck Traffic: 1%,  Average Future Daily Traffic: 4,368 (year 2040),  Design Load: HS 20,  Features Intersected: CHANNEL,  Facility Carried by Structure: SPARKS BL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.2m (36.7ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.6m (8.5ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 76.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2018
Find on map >>   Show street view

Structure Number: B2727,  Location: SPARKS (Lat: 39.612139,  Lng: -119.689736),  Route carried "on" structure: City street ,  Year Built: 1997,  Status: Open,  Structure Length: 0.61m (2.00ft),  Average Daily Traffic: 1,100 (year 2017),  Average Future Daily Traffic: 2,730 (year 2040),  Features Intersected: CHANNEL,  Facility Carried by Structure: WINGFIELD SPRINGS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 3.3m (10.8ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 17.3m (56.8ft)

Condition: Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 19.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: B2728,  Location: SPARKS (Lat: 39.615161,  Lng: -119.681761),  Route carried "on" structure: City street ,  Year Built: 1996,  Status: Open,  Structure Length: 0.61m (2.00ft),  Average Daily Traffic: 1,210 (year 2017),  Average Future Daily Traffic: 3,003 (year 2040),  Features Intersected: CHANNEL,  Facility Carried by Structure: WINGFIELD SPRINGS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.8m (38.7ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 2.9m (9.5ft),  Right: 2.2m (7.2ft),  Curb-To-Curb Width: 11.8m (38.7ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 19.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: B2797,  Location: WEST OF WADSWORTH (Lat: 39.565392,  Lng: -119.486047),  Route carried "on" structure: County highway ,  Year Built: 2008,  Status: Open,  Structure Length: 9.24m (30.31ft),  Average Daily Traffic: 6,500 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 35,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: TRUCKEE RIVER,  Facility Carried by Structure: USA PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 45.7m (149.9ft),  Curb-To-Curb Width: 24.4m (80.1ft),  Out-to-Out Width: 25.3m (83.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 55.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 43.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B2882,  Location: N SPARKS (Lat: 39.597367,  Lng: -119.718317),  Route carried "on" structure: City street ,  Year Built: 2006,  Status: Open,  Structure Length: 0.74m (2.43ft),  Average Daily Traffic: 330 (year 2017),  Truck Traffic: 1%,  Average Future Daily Traffic: 819 (year 2040),  Design Load: HS 20,  Features Intersected: TOE OF SPARKS DAM,  Facility Carried by Structure: VISTA DEL RANCHO
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.7m (38.4ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 2.0m (6.6ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 90.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 67.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2018
Find on map >>   Show street view

Structure Number: B3097,  Location: SE CONNECTOR (Lat: 39.454414,  Lng: -119.725217),  Route carried "on" structure: Alternate City street ,  Year Built: 2018,  Status: Open,  Structure Length: 5.03m (16.50ft),  Average Daily Traffic: 17,500 (year 2017),  Average Future Daily Traffic: 18,500 (year 2037),  Design Load: HL 93,  Features Intersected: CROSS DRAINAGE,  Facility Carried by Structure: VETERANS PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 25.7m (84.3ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 10,  Length of Maximum Span: 1.8m (5.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.3m (10.8ft),  Curb-To-Curb Width: 29.0m (95.1ft),  Out-to-Out Width: 29.0m (95.1ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2020
Find on map >>   Show street view

Structure Number: B3112,  Location: SE CONNECTOR (Lat: 39.507953,  Lng: -119.717903),  Route carried "on" structure: Ramp City street ,  Year Built: 2018,  Status: Open,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 17,500 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 18,500 (year 2037),  Design Load: HL 93,  Features Intersected: CROSS DRAINAGE,  Facility Carried by Structure: VETERANS PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.736,  Lanes on structure: 6,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Very good,  Culverts: Good,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: B3113,  Location: STEAMBOAT CREEK (Lat: 39.498064,  Lng: -119.724211),  Route carried "on" structure: ServiceCity street ,  Year Built: 2018,  Status: Open,  Structure Length: 1.41m (4.63ft),  Average Daily Traffic: 500 (year 2017),  Average Future Daily Traffic: 700 (year 2037),  Design Load: HL 93,  Features Intersected: CROSS DRAINAGE,  Facility Carried by Structure: PEMBROKE DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 0.0m,  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Channel: Good,  Culverts: Good,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: B3114,  Location: SE CONNECTOR (Lat: 39.513222,  Lng: -119.711556),  Route carried "on" structure: Ramp City street ,  Year Built: 2018,  Status: Open,  Structure Length: 1.72m (5.64ft),  Average Daily Traffic: 100 (year 2017),  Average Future Daily Traffic: 125 (year 2040),  Design Load: HL 93,  Features Intersected: STEAMBOAT CREEK,  Facility Carried by Structure: CLEANWATER WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Very good,  Culverts: Good,  Structural Evaluation: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: B3115,  Location: SE CONNECTOR (Lat: 39.511997,  Lng: -119.713928),  Route carried "on" structure: Ramp City street ,  Year Built: 2018,  Status: Open,  Structure Length: 0.78m (2.56ft),  Average Daily Traffic: 17,500 (year 2017),  Average Future Daily Traffic: 18,000 (year 2040),  Design Load: HL 93,  Features Intersected: CROSS DRAINAGE,  Facility Carried by Structure: VETERAN'S PKWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 26.2m (86.0ft),  Skew: 30 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb-To-Curb Width: 27.1m (88.9ft),  Out-to-Out Width: 57.9m (190.0ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 64.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 49.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2020
Find on map >>   Show street view

Structure Number: B3117N,  Location: SOUTHEAST OF SPARKS (Lat: 39.520442,  Lng: -119.711333),  Route carried "on" structure: City street ,  Year Built: 2014,  Status: Open,  Structure Length: 43.07m (141.31ft),  Average Daily Traffic: 17,500 (year 2017),  Average Future Daily Traffic: 18,500 (year 2040),  Design Load: HL 93,  Features Intersected: TRUCKEE RIVER, BIKE PATH,  Facility Carried by Structure: VETERAN'S PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 10,  Length of Maximum Span: 51.8m (169.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Critical Feature Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: B3117S,  Location: SOUTHEAST OF SPARKS (Lat: 39.520417,  Lng: -119.711556),  Route carried "on" structure: City street ,  Year Built: 2014,  Status: Open,  Structure Length: 43.07m (141.31ft),  Average Daily Traffic: 17,500 (year 2017),  Truck Traffic: 1%,  Average Future Daily Traffic: 18,500 (year 2040),  Design Load: HL 93,  Features Intersected: TRUCKEE RIVER, BIKE PATH,  Facility Carried by Structure: VETERAN'S PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 1,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 10,  Length of Maximum Span: 51.8m (169.9ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 0.0m,  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Critical Feature Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: B3263,  Location: LOCKWOOD (Lat: 39.508422,  Lng: -119.646117),  Route carried "on" structure: Ramp City street ,  Year Built: 2018,  Status: Open,  Structure Length: 1.62m (5.31ft),  Average Daily Traffic: 2,900 (year 2017),  Average Future Daily Traffic: 3,100 (year 2037),  Design Load: HS 20,  Features Intersected: LONG VALLEY CREEK,  Facility Carried by Structure: CIRCLE DE CERESE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Local Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.2m (53.1ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 0.0m,  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: G 751,  Location: EAST OF SPARKS (Lat: 39.510975,  Lng: -119.652808),  Route carried "on" structure: ServiceOther road 409,  Year Built: 1962,  Status: Open,  Structure Length: 4.33m (14.21ft),  Average Daily Traffic: 1,300 (year 2017),  Truck Traffic: 40%,  Average Future Daily Traffic: 3,226 (year 2040),  Design Load: HS 20,  Features Intersected: SPRR,  Facility Carried by Structure: FR WA09 CANYON WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 21.0m (68.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Poor,  Operating Rating: 80.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.31m (17.42ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Other Special Inspection Date: May 2020,  Bridge Improvement Cost: $4,270,000,  Roadway Improvement Cost: $430,000,  Total Project Cost: $4,800,000,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Other
Find on map >>   Show street view

Structure Number: G1131,  Location: SPARKS (Lat: 39.530197,  Lng: -119.739722),  Route carried "on" structure: Business City street 659,  Year Built: 1967,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 6.25m (20.51ft),  Average Daily Traffic: 34,000 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 59,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SPRR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.633,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 28.7m (94.2ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.9m (85.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 28.7m (94.2ft),  Out-to-Out Width: 31.4m (103.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 79.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 7.29m (23.92ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $1,596,000,  Roadway Improvement Cost: $160,000,  Total Project Cost: $2,394,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Discuss Sparks, Nevada (NV) on our hugely popular Nevada forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.