Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Strongsville, Ohio (OH)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 66Number of bridges
  • 689ft / 210mTotal length
  • $50,000Total costs
  • 1,540,034Total average daily traffic
  • 156,175Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Strongsville
  • No street view available for this location

New bridges in Strongsville, OH - historical statistics
  • New bridges - historical statistics
  • 21900-1909
  • 21940-1949
  • 201950-1959
  • 311960-1969
  • 21970-1979
  • 21980-1989
  • 21990-1999
  • 12000-2009
  • 42010-2019
Reconstructed bridges in Strongsville, OH - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11960-1969
  • 21970-1979
  • 21980-1989
  • 71990-1999
  • 72000-2009
  • 02010-2019
  • 12020-2022
Average Bridge Daily Traffic in Strongsville, OH
Average Bridge Truck Traffic in Strongsville, OH
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 7.9%Excellent
  • 13.2%Very good
  • 39.5%Good
  • 34.2%Satisfactory
  • 2.6%Fair
  • 2.6%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 2.6%Excellent
  • 21.1%Very good
  • 52.6%Good
  • 10.5%Satisfactory
  • 7.9%Fair
  • 5.3%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 2.6%Excellent
  • 18.4%Very good
  • 42.1%Good
  • 26.3%Satisfactory
  • 7.9%Fair
  • 2.6%Serious
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 5.0%Excellent
  • 5.0%Very good
  • 45.0%Good
  • 30.0%Satisfactory
  • 10.0%Fair
  • 5.0%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 25.0%Very good
  • 25.0%Good
  • 25.0%Satisfactory
  • 25.0%Serious
Find on map >>   Show street view

Structure Number: 1802984,  Location: APPROX 300FT E ALBION RD. (Lat: 41.334389,  Lng: -81.834900),  Route carried "on" structure: US 42,  Year Built: 1988,  Status: Open,  Structure Length: 6.64m (21.78ft),  Average Daily Traffic: 18,894 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 26,225 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: E BR ROCKY R 1.4 MI N 82
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.566,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.8m (65.0ft),  Skew: 5 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 27.4m (89.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 17.4m (57.1ft),  Out-to-Out Width: 21.1m (69.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 1803158,  Location: APPROX 50FT S MAIN ST (Lat: 41.350569,  Lng: -81.821039),  Route carried "on" structure: US 42,  Year Built: 1954,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 25,459 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 35,337 (year 2035),  Design Load: H 20,  Features Intersected: BALDWIN CRK .32 MI S. 71
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.771,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.6m (61.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.2m (17.1ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 1803549,  Location: 2.57 MI. S. OF JCT. SR-82 (Lat: 41.276069,  Lng: -81.806969),  Route carried "on" structure: County highway 127,  Year Built: 1966,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 8.66m (28.41ft),  Average Daily Traffic: 830 (year 1971),  Average Future Daily Traffic: 1,152 (year 1991),  Design Load: H 20,  Features Intersected: IR-71,  Facility Carried by Structure: BOSTON RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.938,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 45.7m (149.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.1m (79.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 1803573,  Location: 1.57 MI. S. OF JCT. SR-82 (Lat: 41.290539,  Lng: -81.808461),  Route carried "on" structure: Interstate 71,  Year Built: 1965,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 4.75m (15.58ft),  Average Daily Traffic: 32,543 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 45,170 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: CR 105 (DRAKE RD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.609,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 20.4m (66.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1803603,  Location: 1.57 MI. S. OF JCT. SR-82 (Lat: 41.290631,  Lng: -81.808131),  Route carried "on" structure: Interstate 71,  Year Built: 1965,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 4.75m (15.58ft),  Average Daily Traffic: 32,543 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 45,170 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: CR 105 (DRAKE RD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.609,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 20.4m (66.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1803638,  Location: JCT. SR-82 WITH I-71 (Lat: 41.313181,  Lng: -81.811219),  Route carried "on" structure: State highway 82,  Year Built: 1965,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 11.00m (36.09ft),  Average Daily Traffic: 30,927 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 42,927 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: CUY-71-0257 ROYALTON RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.584,  Lanes on structure: 6,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 61.0m (200.1ft),  Skew: 21 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 32.9m (107.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 27.4m (89.9ft),  Out-to-Out Width: 31.1m (102.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 38.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 1803662,  Location: .75 MI. N. OF JCT. SR-82 (Lat: 41.324011,  Lng: -81.815081),  Route carried "on" structure: Interstate 71,  Year Built: 1965,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 9.05m (29.69ft),  Average Daily Traffic: 47,034 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 65,283 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: METRO PK DR ROCKY RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.343,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 34.4m (112.9ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 20.4m (66.9ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1803697,  Location: .75 MI. N. OF JCT. SR-82 (Lat: 41.323969,  Lng: -81.814639),  Route carried "on" structure: Interstate 71,  Year Built: 1965,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 9.05m (29.69ft),  Average Daily Traffic: 47,034 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 65,283 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: METRO PK DR ROCKY RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.343,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 34.4m (112.9ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 20.4m (66.9ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1803727,  Location: 1.27 MI. N. OF JCT. SR-84 (Lat: 41.331139,  Lng: -81.816831),  Route carried "on" structure: Interstate 71,  Year Built: 1966,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 3.84m (12.60ft),  Average Daily Traffic: 47,034 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 65,283 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: CR 75 (ALBION RD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.180,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 20.4m (66.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1803751,  Location: 1.27 MI. N. OF JCT. SR-82 (Lat: 41.331111,  Lng: -81.816450),  Route carried "on" structure: Interstate 71,  Year Built: 1966,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 3.57m (11.71ft),  Average Daily Traffic: 47,034 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 65,283 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: CR 75 (ALBION RD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.180,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.1m (43.0ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 20.4m (66.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1803808,  Location: 1.38 M. NORTH OF SR-82 (Lat: 41.333100,  Lng: -81.816969),  Route carried "on" structure: Interstate 71,  Year Built: 1966,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 9.54m (31.30ft),  Average Daily Traffic: 47,034 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 65,283 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: I80 OHIO TURNPIKE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.357,  Lanes on structure: 3,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 34.7m (113.8ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 20.4m (66.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1803816,  Location: 1.38 M. NORTH OF SR-82 (Lat: 41.332969,  Lng: -81.816611),  Route carried "on" structure: Interstate 71,  Year Built: 1966,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 8.96m (29.40ft),  Average Daily Traffic: 47,034 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 65,283 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: I-80 OHIO TURNPIKE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.357,  Lanes on structure: 3,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 32.3m (106.0ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 20.4m (66.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1803875,  Location: .72 MI. N. OF JCT. I-80 (Lat: 41.342969,  Lng: -81.817969),  Route carried "on" structure: County highway C0201,  Year Built: 1966,  Status: Open,  Structure Length: 8.60m (28.22ft),  Average Daily Traffic: 4,948 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,868 (year 2036),  Design Load: HS 20,  Features Intersected: IR71 (UNDER WHITNEY RD),  Facility Carried by Structure: WHITNEY RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.006,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 25.0m (82.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1807455,  Location: BETWEEN IR-71 & WEBSTER (Lat: 41.313269,  Lng: -81.797200),  Route carried "on" structure: State highway 82,  Year Built: 2005,  Status: Open,  Structure Length: 5.01m (16.44ft),  Average Daily Traffic: 27,219 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 37,780 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: ROCKY RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.808,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.6m (61.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 23.1m (75.8ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1828991,  Location: 0.3MI EAST OF EXIT 10 (Lat: 41.333650,  Lng: -81.820000),  Route carried "on" structure: Ramp Interstate 80K,  Year Built: 1967,  Status: Open,  Structure Length: 8.44m (27.69ft),  Average Daily Traffic: 3,864 (year 2016),  Truck Traffic: 12%,  Average Future Daily Traffic: 5,363 (year 2036),  Design Load: HS 20+Mod,  Features Intersected: I80 OH TPK,  Facility Carried by Structure: TPK EXIT 161 RAMP
Minimum Vertical Clearance: 7.62m (25.00ft),  Kilometerpoint: 13.792,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Toll Authority,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 20 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 15.5m (50.9ft),  Out-to-Out Width: 16.9m (55.4ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1829009,  Location: 0.5MI EAST OF EXIT 10 (Lat: 41.337500,  Lng: -81.819219),  Route carried "on" structure: Ramp Interstate 80K,  Year Built: 1969,  Status: Open,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 8,418 (year 2018),  Truck Traffic: 10%,  Average Future Daily Traffic: 11,684 (year 2038),  Features Intersected: TPK EXIT 161 RAMP PEARL,  Facility Carried by Structure: TPK EXIT 161 RAMP
Minimum Vertical Clearance: 0.00m,  Kilometerpoint: 13.792,  Lanes on structure: 5,  Lanes under structure: 1,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 31.4m (103.0ft),  Skew: 22 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.4m (34.1ft),  Curb-To-Curb Width: 30.8m (101.0ft),  Out-to-Out Width: 32.1m (105.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 74.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 1829351,  Location: 7.3MI EAST OF SR-10 (Lat: 41.346731,  Lng: -81.857611),  Route carried "on" structure: State highway 237,  Year Built: 1954,  Status: Open,  Structure Length: 6.49m (21.29ft),  Average Daily Traffic: 17,660 (year 2016),  Truck Traffic: 4%,  Average Future Daily Traffic: 24,512 (year 2036),  Design Load: HS 20+Mod,  Features Intersected: I80 OHIO TPK
Minimum Vertical Clearance: 6.10m (20.01ft),  Kilometerpoint: 3.811,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Toll Authority,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 22.3m (73.2ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 20.3m (66.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1829408,  Location: 8.2MI EAST OF TP 152 (Lat: 41.342261,  Lng: -81.843539),  Route carried "on" structure: Interstate 80K,  Year Built: 1954,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 4.27m (14.01ft),  Average Daily Traffic: 20,419 (year 2018),  Truck Traffic: 31%,  Average Future Daily Traffic: 28,342 (year 2038),  Design Load: HS 20,  Features Intersected: EASTLAND RD,  Facility Carried by Structure: EB I80 OHIO TPK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.394,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 18.4m (60.4ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.8m (45.3ft),  Curb-To-Curb Width: 18.4m (60.4ft),  Out-to-Out Width: 19.4m (63.6ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1829409,  Location: 1.4 MI WEST OF TP 161 (Lat: 41.342439,  Lng: -81.843431),  Route carried "on" structure: Interstate 80K,  Year Built: 1954,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 4.35m (14.27ft),  Average Daily Traffic: 20,000 (year 2018),  Truck Traffic: 31%,  Average Future Daily Traffic: 27,760 (year 2038),  Design Load: HS 20,  Features Intersected: EASTLAND RD,  Facility Carried by Structure: WB I80 OHIO TPK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.394,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 18.2m (59.7ft),  Skew: 11 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.9m (45.6ft),  Curb-To-Curb Width: 18.2m (59.7ft),  Out-to-Out Width: 19.1m (62.7ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1829432,  Location: 8.5MI EAST OF EXIT 152 (Lat: 41.342381,  Lng: -81.837400),  Route carried "on" structure: Interstate 80K,  Year Built: 1953,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 7.04m (23.10ft),  Average Daily Traffic: 13,000 (year 1990),  Truck Traffic: 14%,  Average Future Daily Traffic: 18,044 (year 2010),  Design Load: HS 20,  Features Intersected: E BRANCH ROCKY RIVER,  Facility Carried by Structure: I80 OHIO TPK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.893,  Lanes on structure: 6,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 36.6m (120.1ft),  Skew: 32 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.5m (77.1ft),  Curb-To-Curb Width: 37.4m (122.7ft),  Out-to-Out Width: 38.3m (125.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 87.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1829467,  Location: 8.5MI EAST OF EXIT 152 (Lat: 41.342439,  Lng: -81.836231),  Route carried "on" structure: Interstate 80K,  Year Built: 1954,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 5.70m (18.70ft),  Average Daily Traffic: 13,000 (year 1990),  Truck Traffic: 23%,  Average Future Daily Traffic: 18,044 (year 2010),  Design Load: HS 20+Mod,  Features Intersected: VALLEY PKWY,  Facility Carried by Structure: I80 OH TPK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.990,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 36.6m (120.1ft),  Skew: 31 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.6m (61.0ft),  Curb-To-Curb Width: 37.4m (122.7ft),  Out-to-Out Width: 38.3m (125.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 87.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1829491,  Location: 8.8MI EAST OF EXIT 9 (Lat: 41.341969,  Lng: -81.830861),  Route carried "on" structure: City street BIGCK,  Year Built: 1954,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 6.98m (22.90ft),  Average Daily Traffic: 26,000 (year 1990),  Truck Traffic: 23%,  Average Future Daily Traffic: 54,945 (year 2010),  Design Load: H 10,  Features Intersected: I80 OHIO TPK,  Facility Carried by Structure: BIG CREEK PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Toll Authority,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 15.5m (50.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1829513,  Location: 0.4MI WEST OF EXIT 10 (Lat: 41.341069,  Lng: -81.828300),  Route carried "on" structure: US 42,  Year Built: 1954,  Year Reconstructed: 1983,  Status: Open,  Structure Length: 6.16m (20.21ft),  Average Daily Traffic: 26,195 (year 2016),  Truck Traffic: 4%,  Average Future Daily Traffic: 36,359 (year 2036),  Design Load: HS 20+Mod,  Features Intersected: I80 OHIO TPK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.524,  Lanes on structure: 4,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Toll Authority,  Approaching Roadway Width: 17.4m (57.1ft),  Skew: 20 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 22.6m (74.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 17.4m (57.1ft),  Out-to-Out Width: 21.6m (70.9ft)

Condition: Deck: Excellent,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1829521,  Location: 0.43 MI. N. OF JCT. I-80 (Lat: 41.338689,  Lng: -81.817119),  Route carried "on" structure: Ramp Interstate 80K,  Year Built: 1966,  Status: Open,  Structure Length: 9.69m (31.79ft),  Average Daily Traffic: 74,360 (year 1991),  Truck Traffic: 6%,  Average Future Daily Traffic: 103,212 (year 2011),  Design Load: HS 20+Mod,  Features Intersected: IR 71,  Facility Carried by Structure: TPK EXIT 161 RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.790,  Lanes on structure: 2,  Lanes under structure: 7,  Owner: State Toll Authority,  Approaching Roadway Width: 16.2m (53.1ft),  Skew: 20 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 32.3m (106.0ft),  Curb-To-Curb Width: 15.5m (50.9ft),  Out-to-Out Width: 16.9m (55.4ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1829548,  Location: AT EXIT 161 (Lat: 41.337811,  Lng: -81.824169),  Route carried "on" structure: Ramp Interstate 80K,  Year Built: 1954,  Status: Open,  Structure Length: 6.61m (21.69ft),  Average Daily Traffic: 12,400 (year 1980),  Average Future Daily Traffic: 17,211 (year 2000),  Design Load: HS 20,  Features Intersected: I80 OHIO TURNPIKE,  Facility Carried by Structure: EXIT161 RAMP PEARL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.521,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Toll Authority,  Approaching Roadway Width: 9.4m (30.8ft),  Skew: 20 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 23.5m (77.1ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1829599,  Location: 0.4 MI EAST OF GATE 10 (Lat: 41.331461,  Lng: -81.813331),  Route carried "on" structure: County highway C0075,  Year Built: 1998,  Status: Open,  Structure Length: 9.27m (30.41ft),  Average Daily Traffic: 100 (year 1970),  Truck Traffic: 10%,  Average Future Daily Traffic: 59,434 (year 1990),  Design Load: HS 20+Mod,  Features Intersected: I80 OHIO TURNPIKE,  Facility Carried by Structure: ALBION ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.421,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Toll Authority,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.3m (92.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 87.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1829629,  Location: 1.4MI EAST OF EXIT 10 (Lat: 41.328400,  Lng: -81.800961),  Route carried "on" structure: City street M0192,  Year Built: 1954,  Year Reconstructed: 2020,  Status: Posted for load,  Structure Length: 6.22m (20.41ft),  Average Daily Traffic: 30,000 (year 1990),  Truck Traffic: 20%,  Average Future Daily Traffic: 34,922 (year 2010),  Features Intersected: I80 OHIO TPK,  Facility Carried by Structure: WEBSTER RD
Minimum Vertical Clearance: 6.10m (20.01ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Toll Authority,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 21.0m (68.9ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Excellent,  Superstructure: Good,  Substructure: Good,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 19.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1829645,  Location: 2.3MI EAST OF EXIT 10 (Lat: 41.323011,  Lng: -81.785289),  Route carried "on" structure: City street 48,  Year Built: 1954,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 8.11m (26.61ft),  Average Daily Traffic: 8,880 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 12,325 (year 2036),  Design Load: HS 20+Mod,  Features Intersected: I80 OHIO TPK,  Facility Carried by Structure: W 130TH ST
Minimum Vertical Clearance: 11.58m (37.99ft),  Kilometerpoint: 5.139,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Toll Authority,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 77.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1831542,  Location: 110 FT EAST OF HUNT ROAD (Lat: 41.290739,  Lng: -81.804789),  Route carried "on" structure: County highway C0105,  Year Built: 1940,  Year Reconstructed: 1974,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 3,446 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,783 (year 2035),  Design Load: H 15,  Features Intersected: CREEK E BR ROCKY RIVER,  Facility Carried by Structure: DRAKE ROAD CR 105
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.426,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 5.8m (19.0ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 60.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Length Of Structure Improvement: 0.91m (2.99ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: September 2021,  Bridge Improvement Cost: $45,000,  Roadway Improvement Cost: $5,000,  Total Project Cost: $50,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1832905,  Location: 136 FT SOUTHEAST OF DRAKE (Lat: 41.290450,  Lng: -81.804850),  Route carried "on" structure: County highway C0107,  Year Built: 1940,  Status: Posted for load,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 3,446 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,783 (year 2035),  Design Load: H 15,  Features Intersected: CREEK E BR ROCKY RIVER,  Facility Carried by Structure: HUNT ROAD CR 107
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.032,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.1m (26.6ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 24.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 18.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1833162,  Location: 124' E. OF PEARL ROAD (Lat: 41.350669,  Lng: -81.820811),  Route carried "on" structure: County highway 67,  Year Built: 1965,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 9,039 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 12,546 (year 2035),  Design Load: H 15,  Features Intersected: BALDWIN CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.463,  Lanes on structure: 5,  Owner: County Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.2m (17.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 46.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: 1833294,  Location: 5673 FT E OF EASTLAND RD (Lat: 41.350700,  Lng: -81.825400),  Route carried "on" structure: County highway C0231,  Year Built: 2010,  Status: Open,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 3,070 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,261 (year 2035),  Design Load: HL 93,  Features Intersected: BALDWIN CREEK,  Facility Carried by Structure: MAIN STREET CR 231
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.770,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.5m (50.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 69.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1833368,  Location: 70 FEET S OF FAIR ROAD (Lat: 41.349661,  Lng: -81.867961),  Route carried "on" structure: County highway 182,  Year Built: 2015,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 8,910 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 12,367 (year 2035),  Design Load: HL 93,  Features Intersected: BLODGETT CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.060,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.4m (21.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1860001,  Location: WEST OFF STATE ROAD (Lat: 41.422831,  Lng: -81.710789),  Route carried "on" structure: City street WETZL,  Year Built: 2017,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 110 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,796 (year 2035),  Design Load: HL 93,  Features Intersected: BIG CREEK,  Facility Carried by Structure: WETZEL AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 129.375,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.1m (26.6ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 1860005,  Location: 200 ft. W. of Valley Pkwy (Lat: 41.342861,  Lng: -81.836761),  Route carried "on" structure: City street WHITY,  Year Built: 1983,  Status: Posted for load,  Structure Length: 2.87m (9.42ft),  Average Daily Traffic: 500 (year 2015),  Truck Traffic: 1%,  Average Future Daily Traffic: 694 (year 2035),  Design Load: HS 20,  Features Intersected: East Branch Rocky River,  Facility Carried by Structure: WHITNEY ROAD
Minimum Vertical Clearance: 2.74m (8.99ft),  Kilometerpoint: 1.502,  Lanes on structure: 1,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 4.3m (14.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 27.4m (89.9ft),  Curb or Sidewalk Widths: Left: 2.2m (7.2ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 4.2m (13.8ft),  Out-to-Out Width: 7.1m (23.3ft)

Condition: Deck: Satisfactory,  Superstructure: Poor,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 19.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1890468,  Location: 100' South of Valle Pkwy (Lat: 41.319111,  Lng: -81.807931),  Route carried "on" structure: Other road CMP,  Year Built: 1963,  Status: Open,  Structure Length: 3.47m (11.38ft),  Average Daily Traffic: 1,000 (year 1995),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,388 (year 2015),  Design Load: HS 15,  Features Intersected: East Branch Rocky River,  Facility Carried by Structure: Wetlands Drive
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.048,  Lanes on structure: 2,  Owner: Local Park, Forest, or Reservation Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 6.1m (20.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1890476,  Location: 50' S. of Valley Parkway (Lat: 41.324019,  Lng: -81.816719),  Route carried "on" structure: Other road CMP,  Year Built: 1963,  Status: Open,  Structure Length: 3.81m (12.50ft),  Average Daily Traffic: 2,000 (year 1995),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,776 (year 2015),  Features Intersected: East Branch Rocky River,  Facility Carried by Structure: Chalet Drive
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.198,  Lanes on structure: 1,  Owner: Local Park, Forest, or Reservation Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 6.1m (20.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 1890514,  Location: 0.22 mi. N of SR 82 (Lat: 41.314911,  Lng: -81.802189),  Route carried "on" structure: Other road CMP,  Year Built: 1900,  Year Reconstructed: 1975,  Status: Open,  Structure Length: 2.93m (9.61ft),  Average Daily Traffic: 1,000 (year 1995),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,388 (year 2015),  Features Intersected: East Branch Rocky River,  Facility Carried by Structure: Cheerful Lane
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.301,  Lanes on structure: 1,  Owner: Local Park, Forest, or Reservation Agency,  Approaching Roadway Width: 4.0m (13.1ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 14.0m (45.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 3.8m (12.5ft),  Out-to-Out Width: 4.3m (14.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Serious,  Channel: Poor,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Critical Feature Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Discuss Strongsville, Ohio (OH) on our hugely popular Ohio forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.