  • National Bridge Inventory (NBI) Statistics
  • 13Number of bridges
  • 112ft / 33.8mTotal length
  • $2,987,000Total costs
  • 90,425Total average daily traffic
  • 6,244Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Ambridge
  • No street view available for this location

New bridges in Ambridge, PA - historical statistics
  • New bridges - historical statistics
  • 1Before 1900
  • 11920-1929
  • 21950-1959
  • 41960-1969
  • 11970-1979
  • 41990-1999
Reconstructed bridges in Ambridge, PA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11970-1979
  • 11980-1989
  • 11990-1999
  • 02000-2009
  • 12010-2019
Average Bridge Daily Traffic in Ambridge, PA
Average Bridge Truck Traffic in Ambridge, PA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 80.0%Satisfactory
  • 20.0%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 33.3%Good
  • 50.0%Satisfactory
  • 16.7%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 66.7%Satisfactory
  • 33.3%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 33.3%Very good
  • 66.7%Fair
Find on map >>   Show street view

Structure Number: 3538,  Location: @ MERCHANT ST. EXTENTION (Lat: 40.602153,  Lng: -80.232058),  Route carried "on" structure: State highway 65,  Year Built: 1960,  Year Reconstructed: 2010,  Status: Open,  Structure Length: 7.86m (25.79ft),  Average Daily Traffic: 20,456 (year 2022),  Truck Traffic: 7%,  Average Future Daily Traffic: 27,182 (year 2032),  Design Load: HS 20,  Features Intersected: FRENCH POINT CREEK,  Facility Carried by Structure: OHIO RIVER BL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.932,  Lanes on structure: 5,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.3m (69.9ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 3,  Length of Maximum Span: 30.5m (100.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 20.4m (66.9ft),  Out-to-Out Width: 21.5m (70.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 59.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 7.90m (25.92ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Bridge Improvement Cost: $217,000,  Roadway Improvement Cost: $640,000,  Total Project Cost: $2,933,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3842,  Location: 102001 BIG SEWICK CK BRDG (Lat: 40.581203,  Lng: -80.216436),  Route carried "on" structure: City street ,  Year Built: 1978,  Status: Posted for load,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 150 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 158 (year 2040),  Design Load: HS 20,  Features Intersected: BIG SEWICKLEY CREEK,  Facility Carried by Structure: VALLEY RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 37.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 15.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Length Of Structure Improvement: 2.00m (6.56ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: May 2020,  Other Special Inspection Date: May 2021,  Bridge Improvement Cost: $4,000,  Roadway Improvement Cost: $27,000,  Total Project Cost: $54,000,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 3893,  Location: 402001 AMBR-LEETSDALELINE (Lat: 40.579644,  Lng: -80.220772),  Route carried "on" structure: City street ,  Year Built: 1827,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 2,000 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,100 (year 2041),  Features Intersected: BIG SEWICKLEY CREEK,  Facility Carried by Structure: MERCHANT ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Masonry,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.3m (37.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Superstructure: Satisfactory,  Substructure: Fair,  Channel: Fair,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.10m (3.61ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 3895,  Location: 004059 .5M S/SR 0065&0989 (Lat: 40.580961,  Lng: -80.226989),  Route carried "on" structure: Ramp Other road ,  Year Built: 1990,  Status: Open,  Structure Length: 19.96m (65.49ft),  Average Daily Traffic: 350 (year 2019),  Truck Traffic: 20%,  Average Future Daily Traffic: 400 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: SR 0065,& NORFOLK SOUTHE,  Facility Carried by Structure: RNR-ACCESS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 41.5m (136.2ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 70.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 20.00m (65.62ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 46218,  Location: AMBRIDGE SIDE (Lat: 40.592481,  Lng: -80.233503),  Route carried "on" structure: State highway ,  Year Built: 1960,  Year Reconstructed: 1985,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 11,401 (year 2022),  Truck Traffic: 7%,  Average Future Daily Traffic: 14,588 (year 2032),  Design Load: HS 20,  Features Intersected: ROUTE 65,  Facility Carried by Structure: AMB- ALIQU BRIDGE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.014,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.1m (43.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.0m (29.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 46219,  Location: ALIQUIPPA SIDE (Lat: 40.591667,  Lng: -80.236667),  Route carried "on" structure: State highway ,  Year Built: 1958,  Year Reconstructed: 1984,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 11,401 (year 2022),  Truck Traffic: 7%,  Average Future Daily Traffic: 14,588 (year 2032),  Design Load: HS 20,  Features Intersected: ROUTE 51,  Facility Carried by Structure: AMB-ALIQUIP BRIDG
Minimum Vertical Clearance: 6.37m (20.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.5m (41.0ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 60.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 3538,  Location: @ MERCHANT ST. EXTENTION (Lat: 40.602153,  Lng: -80.232058),  Route carried "under" structure: City street ,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 25 (year 1993),  Truck Traffic: 1%,  Features Intersected: FRENCH POINT CREEK,  Facility Carried by Structure: OHIO RIVER BL
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.5m (100.1ft)

Find on map >>   Show street view

Structure Number: 3894,  Location: AMBRIDGE-ALIQUIPPA SP 2-9 (Lat: 40.592317,  Lng: -80.237189),  Route carried "under" structure: State highway 65,  Year Built: 1927,  Structure Length: 0. m,  Average Daily Traffic: 10,150 (year 2022),  Truck Traffic: 7%,  Features Intersected: OHIO RIVER, 2 RR,  Facility Carried by Structure: AMBRIDGE-ALIQ BR
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 1.423,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Truss - Thru,  Length of Maximum Span: 161.5m (529.9ft)

Find on map >>   Show street view

Structure Number: 3895,  Location: 004059 .5M S/SR 0065&0989 (Lat: 40.580961,  Lng: -80.226989),  Route carried "under" structure: State highway 65,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 9,739 (year 2021),  Truck Traffic: 6%,  Features Intersected: SR 0065,& NORFOLK SOUTHE,  Facility Carried by Structure: RNR-ACCESS RD
Minimum Vertical Clearance: 7.99m (26.21ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.5m (136.2ft)

Find on map >>   Show street view

Structure Number: 3895,  Location: 004059 .5M S/SR 0065&0989 (Lat: 40.580961,  Lng: -80.226989),  Route carried "under" structure: State highway 65,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 8,887 (year 2021),  Truck Traffic: 7%,  Features Intersected: SR 0065,& NORFOLK SOUTHE,  Facility Carried by Structure: RNR-ACCESS RD
Minimum Vertical Clearance: 7.96m (26.12ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.5m (136.2ft)

Find on map >>   Show street view

Structure Number: 3895,  Location: 004059 .5M S/SR 0065&0989 (Lat: 40.580961,  Lng: -80.226989),  Route carried "under" structure: ServiceOther road ,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 50 (year 2019),  Truck Traffic: 30%,  Features Intersected: SR 0065,& NORFOLK SOUTHE,  Facility Carried by Structure: RNR-ACCESS RD
Minimum Vertical Clearance: 6.81m (22.34ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.5m (136.2ft)

Find on map >>   Show street view

Structure Number: 46218,  Location: AMBRIDGE SIDE (Lat: 40.592481,  Lng: -80.233503),  Route carried "under" structure: State highway 65,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 10,306 (year 2022),  Truck Traffic: 7%,  Features Intersected: ROUTE 65,  Facility Carried by Structure: AMB- ALIQU BRIDGE
Minimum Vertical Clearance: 4.44m (14.57ft),  Kilometerpoint: 1.415,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 13.1m (43.0ft)

Find on map >>   Show street view

Structure Number: 46219,  Location: ALIQUIPPA SIDE (Lat: 40.591667,  Lng: -80.236667),  Route carried "under" structure: State highway 51,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 5,510 (year 2022),  Truck Traffic: 7%,  Features Intersected: ROUTE 51,  Facility Carried by Structure: AMB-ALIQUIP BRIDG
Minimum Vertical Clearance: 6.27m (20.57ft),  Kilometerpoint: 1.931,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 12.5m (41.0ft)