Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Bagdad, Florida (FL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 14Number of bridges
  • 755ft / 230mTotal length
  • 185,802Total average daily traffic
  • 34,751Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Bagdad
  • No street view available for this location

New bridges in Bagdad, FL - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 11940-1949
  • 81960-1969
  • 21990-1999
  • 22000-2009
Reconstructed bridges in Bagdad, FL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11960-1969
  • 01970-1979
  • 01980-1989
  • 11990-1999
Average Bridge Daily Traffic in Bagdad, FL
Average Bridge Truck Traffic in Bagdad, FL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 12.5%Good
  • 75.0%Satisfactory
  • 12.5%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 50.0%Good
  • 50.0%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 62.5%Good
  • 37.5%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 25.0%Excellent
  • 25.0%Very good
  • 25.0%Good
  • 12.5%Fair
  • 12.5%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 66.7%Satisfactory
  • 33.3%Fair
Find on map >>   Show street view

Structure Number: 580003,  Location: 1.1 mi South of SR 87 (Lat: 30.607072,  Lng: -87.034781),  Route carried "on" structure: County highway 191,  Year Built: 1946,  Status: Open,  Structure Length: 14.69m (48.20ft),  Average Daily Traffic: 8,100 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 14,054 (year 2042),  Design Load: HS 20,  Features Intersected: Pond Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.136,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 12,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 1.1m (3.6ft),  Right: 1.1m (3.6ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 50.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Underwater Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 580016,  Location: 0.3 Mi South of I-10 (Lat: 30.565281,  Lng: -87.032881),  Route carried "on" structure: County highway 191,  Year Built: 1901,  Year Reconstructed: 1967,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 2,300 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 3,991 (year 2042),  Design Load: HS 20,  Features Intersected: Unnamed Branch
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.397,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.2m (10.5ft)

Condition: Channel: Poor,  Culverts: Fair,  Operating Rating: 56.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 12 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: July 2021,  Underwater Inspection Date: July 2021,  Other Special Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: 58006,  Location: 5.2 Miles West Of SR87 (Lat: 30.569717,  Lng: -87.031478),  Route carried "on" structure: Interstate 10,  Year Built: 1967,  Status: Open,  Structure Length: 6.31m (20.70ft),  Average Daily Traffic: 19,750 (year 2020),  Truck Traffic: 21%,  Average Future Daily Traffic: 34,266 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: CR191 Garcon Point Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.092,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.6m (107.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 580074,  Location: 0.4mi West of CR191 (Lat: 30.565853,  Lng: -87.036678),  Route carried "on" structure: Interstate 10,  Year Built: 1967,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 43,500 (year 2020),  Truck Traffic: 19%,  Average Future Daily Traffic: 75,472 (year 2042),  Design Load: HS 20,  Features Intersected: Sandy Point
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.486,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 14 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.4m (14.4ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 86.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Underwater Inspection Date: June 2020
Find on map >>   Show street view

Structure Number: 580075,  Location: 5.2 Miles West Of SR87 (Lat: 30.570042,  Lng: -87.031469),  Route carried "on" structure: Interstate 10,  Year Built: 1967,  Status: Open,  Structure Length: 6.31m (20.70ft),  Average Daily Traffic: 19,750 (year 2020),  Truck Traffic: 21%,  Average Future Daily Traffic: 34,266 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: CR191 Garcon Point Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.092,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.6m (107.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 580076,  Location: 4.4mi West of SR87 (Lat: 30.579078,  Lng: -87.019686),  Route carried "on" structure: County highway 191C,  Year Built: 1967,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 6.37m (20.90ft),  Average Daily Traffic: 463 (year 2010),  Truck Traffic: 3%,  Average Future Daily Traffic: 803 (year 2032),  Design Load: HS 20,  Features Intersected: I10 SR8
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.259,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.9m (104.7ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Inventory Rating: 78.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 580167,  Location: 4.0 Miles West of SR87 (Lat: 30.584650,  Lng: -87.012944),  Route carried "on" structure: Interstate 10,  Year Built: 1997,  Status: Open,  Structure Length: 94.76m (310.89ft),  Average Daily Traffic: 19,750 (year 2020),  Truck Traffic: 21%,  Average Future Daily Traffic: 34,266 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: Blackwater River
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.064,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Navigation Control: Yes ( Vertical Clearance: 13.7m (44.9ft), Horizontal Clearance: 38.1m (125.0ft)),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 16,  Number Of Approach Spans: 6,  Length of Maximum Span: 67.1m (220.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 55.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Underwater Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 580168,  Location: 4.0 Miles West of SR87 (Lat: 30.584256,  Lng: -87.012708),  Route carried "on" structure: Interstate 10,  Year Built: 1997,  Status: Open,  Structure Length: 94.74m (310.83ft),  Average Daily Traffic: 19,750 (year 2020),  Truck Traffic: 21%,  Average Future Daily Traffic: 34,266 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: Blackwater River
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.064,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Navigation Control: Yes ( Vertical Clearance: 13.0m (42.7ft), Horizontal Clearance: 38.1m (125.0ft)),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 16,  Number Of Approach Spans: 6,  Length of Maximum Span: 67.1m (220.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 58.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Underwater Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 58418,  Location: 0.12 Mi S of CR 191C (Lat: 30.548931,  Lng: -87.026011),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 1.24m (4.07ft),  Average Daily Traffic: 75 (year 2020),  Average Future Daily Traffic: 130 (year 2042),  Design Load: HS 20,  Features Intersected: Unnamed Branch,  Facility Carried by Structure: Waterview Drive
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.241,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.2m (10.5ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 7.0m (23.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 37.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Underwater Inspection Date: March 2020,  Deck Structure Type: Wood or Timber
Find on map >>   Show street view

Structure Number: 584187,  Location: 0.8 MI E of CR 191 (Lat: 30.550783,  Lng: -87.031256),  Route carried "on" structure: County highway ,  Year Built: 2002,  Status: Open,  Structure Length: 2.69m (8.83ft),  Average Daily Traffic: 132 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 229 (year 2042),  Design Load: HS 20,  Features Intersected: Jakes Bayou,  Facility Carried by Structure: Robinson Pt Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.257,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 7.6m (24.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 584219,  Location: 1.28 Mi S of I-10 (Lat: 30.561111,  Lng: -87.017222),  Route carried "on" structure: County highway ,  Year Built: 1962,  Status: Open,  Structure Length: 0.63m (2.07ft),  Average Daily Traffic: 132 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 229 (year 2042),  Design Load: HL 93,  Features Intersected: Sandy Point Bayou,  Facility Carried by Structure: Robinson Point Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.213,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.2m (20.3ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 58.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 44.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Underwater Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 58006,  Location: 5.2 Miles West Of SR87 (Lat: 30.569717,  Lng: -87.031478),  Route carried "under" structure: County highway 191,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 6,300 (year 2020),  Truck Traffic: 6%,  Features Intersected: CR191 Garcon Point Road,  Facility Carried by Structure: I10 SR8
Minimum Vertical Clearance: 4.66m (15.29ft),  Kilometerpoint: 15.923,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.6m (107.0ft)

Find on map >>   Show street view

Structure Number: 580075,  Location: 5.2 Miles West Of SR87 (Lat: 30.570042,  Lng: -87.031469),  Route carried "under" structure: County highway 191,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 6,300 (year 2020),  Truck Traffic: 6%,  Features Intersected: CR191 Garcon Point Road,  Facility Carried by Structure: I10 SR8
Minimum Vertical Clearance: 4.66m (15.29ft),  Kilometerpoint: 15.961,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.6m (107.0ft)

Find on map >>   Show street view

Structure Number: 580076,  Location: 4.4mi West of SR87 (Lat: 30.579078,  Lng: -87.019686),  Route carried "under" structure: Interstate 10,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 39,500 (year 2020),  Truck Traffic: 21%,  Features Intersected: I10 SR8,  Facility Carried by Structure: CR191C
Minimum Vertical Clearance: 5.00m (16.40ft),  Kilometerpoint: 16.647,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.9m (104.7ft)

Discuss Bagdad, Florida (FL) on our hugely popular Florida forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.