Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Bailey, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 14Number of bridges
  • 125ft / 38.0mTotal length
  • 137,140Total average daily traffic
  • 20,705Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Bailey
  • No street view available for this location

New bridges in Bailey, NC - historical statistics
  • New bridges - historical statistics
  • 11960-1969
  • 111970-1979
  • 11990-1999
  • 12010-2019
Average Bridge Daily Traffic in Bailey, NC
Average Bridge Truck Traffic in Bailey, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 20.0%Excellent
  • 20.0%Good
  • 60.0%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 20.0%Excellent
  • 40.0%Good
  • 40.0%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 20.0%Excellent
  • 80.0%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 50.0%Good
  • 50.0%Satisfactory
Find on map >>   Show street view

Structure Number: 1270053,  Location: 0.2M. S. JCT. SR1175 (Lat: 35.787481,  Lng: -78.116875),  Route carried "on" structure: State highway 581,  Year Built: 1976,  Status: Open,  Structure Length: 7.80m (25.59ft),  Average Daily Traffic: 5,100 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 10,200 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US264
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 22.2m (72.8ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 39.3m (128.9ft),  Curb-To-Curb Width: 25.6m (84.0ft),  Out-to-Out Width: 26.2m (86.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 65.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1270055,  Location: 0.2 MI S. JCT US264ALT. (Lat: 35.778725,  Lng: -78.136439),  Route carried "on" structure: State highway 1100,  Year Built: 1999,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 680 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,360 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CAMP BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.6m (11.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 83.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 1270103,  Location: 0.4 MI W. OF SR1100 (Lat: 35.775536,  Lng: -78.143967),  Route carried "on" structure: State highway 1105,  Year Built: 2019,  Status: Open,  Structure Length: 3.50m (11.48ft),  Average Daily Traffic: 440 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 880 (year 2040),  Design Load: HL 93,  Features Intersected: HAW BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 16.7m (54.8ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 47.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1270206,  Location: 0.3 MI.S. OF SR1962 (Lat: 35.785325,  Lng: -78.098467),  Route carried "on" structure: State highway 1961,  Year Built: 1977,  Status: Open,  Structure Length: 7.58m (24.87ft),  Average Daily Traffic: 470 (year 2015),  Truck Traffic: 6%,  Average Future Daily Traffic: 940 (year 2025),  Design Load: HS 15,  Features Intersected: US264
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 37.4m (122.7ft),  Curb-To-Curb Width: 10.9m (35.8ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 56.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1270208,  Location: 0.2 MI. N. SR1968 (Lat: 35.782131,  Lng: -78.087350),  Route carried "on" structure: State highway 1945,  Year Built: 1977,  Status: Open,  Structure Length: 9.84m (32.28ft),  Average Daily Traffic: 700 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,400 (year 2040),  Design Load: HS 15,  Features Intersected: US264
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.753,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.7m (31.8ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 36.8m (120.7ft),  Curb-To-Curb Width: 10.9m (35.8ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 48.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1810001,  Location: 0.6 OF A MI. S. OF SR1126 (Lat: 36.321067,  Lng: -78.504867),  Route carried "on" structure: Interstate 85,  Year Built: 1969,  Year Reconstructed: 2008,  Status: Open,  Structure Length: 7.77m (25.49ft),  Average Daily Traffic: 22,750 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 45,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US158 BYP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 63.612,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 85),  Owner: State Highway Agency,  Approaching Roadway Width: 11.2m (36.7ft),  Skew: 13 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 38.4m (126.0ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 82.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1270053,  Location: 0.2M. S. JCT. SR1175 (Lat: 35.787481,  Lng: -78.116875),  Route carried "under" structure: US 264,  Year Built: 1976,  Structure Length: 0. m,  Average Daily Traffic: 13,000 (year 2017),  Truck Traffic: 14%,  Features Intersected: NC581
Minimum Vertical Clearance: 5.53m (18.14ft),  Kilometerpoint: 9.326,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.3m (128.9ft)

Find on map >>   Show street view

Structure Number: 1270053,  Location: 0.2M. S. JCT. SR1175 (Lat: 35.787481,  Lng: -78.116875),  Route carried "under" structure: US 264,  Year Built: 1976,  Structure Length: 0. m,  Average Daily Traffic: 13,000 (year 2017),  Truck Traffic: 14%,  Features Intersected: NC581
Minimum Vertical Clearance: 5.10m (16.73ft),  Kilometerpoint: 9.235,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.3m (128.9ft)

Find on map >>   Show street view

Structure Number: 127018,  Location: 0.4 MI.S. OF SR1175 (Lat: 35.789375,  Lng: -78.138131),  Route carried "under" structure: US 264,  Year Built: 1976,  Structure Length: 0. m,  Average Daily Traffic: 13,000 (year 2017),  Truck Traffic: 14%,  Features Intersected: SR1106
Minimum Vertical Clearance: 5.02m (16.47ft),  Kilometerpoint: 8.686,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.4m (126.0ft)

Find on map >>   Show street view

Structure Number: 127018,  Location: 0.4 MI.S. OF SR1175 (Lat: 35.789375,  Lng: -78.138131),  Route carried "under" structure: US 264,  Year Built: 1976,  Structure Length: 0. m,  Average Daily Traffic: 13,000 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1106
Minimum Vertical Clearance: 5.02m (16.47ft),  Kilometerpoint: 8.686,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.4m (126.0ft)

Find on map >>   Show street view

Structure Number: 1270206,  Location: 0.3 MI.S. OF SR1962 (Lat: 35.785325,  Lng: -78.098467),  Route carried "under" structure: US 264,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 12,500 (year 2015),  Truck Traffic: 14%,  Features Intersected: SR1961
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.4m (122.7ft)

Find on map >>   Show street view

Structure Number: 1270206,  Location: 0.3 MI.S. OF SR1962 (Lat: 35.785325,  Lng: -78.098467),  Route carried "under" structure: US 264,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 12,500 (year 2015),  Truck Traffic: 14%,  Features Intersected: SR1961
Minimum Vertical Clearance: 4.87m (15.98ft),  Kilometerpoint: 9.540,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.4m (122.7ft)

Find on map >>   Show street view

Structure Number: 1270208,  Location: 0.2 MI. N. SR1968 (Lat: 35.782131,  Lng: -78.087350),  Route carried "under" structure: US 264,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 15,000 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1945
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 9.814,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.8m (120.7ft)

Find on map >>   Show street view

Structure Number: 1270208,  Location: 0.2 MI. N. SR1968 (Lat: 35.782131,  Lng: -78.087350),  Route carried "under" structure: US 264,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 15,000 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1945
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 9.814,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.8m (120.7ft)

Discuss Bailey, North Carolina (NC) on our hugely popular North Carolina forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.