Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Brookfield Center, Ohio (OH)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 13Number of bridges
  • 118ft / 36.4mTotal length
  • 43,608Total average daily traffic
  • 5,211Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Brookfield Center
  • No street view available for this location

New bridges in Brookfield Center, OH - historical statistics
  • New bridges - historical statistics
  • 11940-1949
  • 91950-1959
  • 11980-1989
  • 11990-1999
  • 12000-2009
Average Bridge Daily Traffic in Brookfield Center, OH
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 18.2%Excellent
  • 63.6%Good
  • 9.1%Satisfactory
  • 9.1%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 18.2%Excellent
  • 54.5%Good
  • 9.1%Satisfactory
  • 9.1%Fair
  • 9.1%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 18.2%Excellent
  • 18.2%Very good
  • 27.3%Good
  • 27.3%Satisfactory
  • 9.1%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 66.7%Very good
  • 16.7%Good
  • 16.7%Fair
Find on map >>   Show street view

Structure Number: 7804806,  Location: 1.91 MI W OF SR 7 (Lat: 41.230061,  Lng: -80.604850),  Route carried "on" structure: State highway 82,  Year Built: 1957,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 5.21m (17.09ft),  Average Daily Traffic: 6,164 (year 2015),  Truck Traffic: 13%,  Average Future Daily Traffic: 8,556 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: OVER NORFOLK SOUTHERN RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 40.620,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 780483,  Location: 1.91 MI W OF SR 7 (Lat: 41.229750,  Lng: -80.604739),  Route carried "on" structure: State highway 82,  Year Built: 1957,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 5.21m (17.09ft),  Average Daily Traffic: 6,164 (year 2015),  Truck Traffic: 13%,  Average Future Daily Traffic: 8,556 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: OVER NORFOLK SOUTHERN RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 40.620,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7804865,  Location: 1.74 MI W OF SR 7 (Lat: 41.229711,  Lng: -80.601400),  Route carried "on" structure: State highway 82,  Year Built: 1957,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 4.03m (13.22ft),  Average Daily Traffic: 6,164 (year 2015),  Truck Traffic: 13%,  Average Future Daily Traffic: 8,556 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: OVER ALBRIGHT-MCKAY RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 40.893,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7804954,  Location: 1.74 MI W OF SR 7 (Lat: 41.229431,  Lng: -80.601519),  Route carried "on" structure: State highway 82,  Year Built: 1957,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 4.03m (13.22ft),  Average Daily Traffic: 6,164 (year 2015),  Truck Traffic: 13%,  Average Future Daily Traffic: 8,556 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: OVER ALBRIGHT-MCKAY RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 40.893,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7804989,  Location: 1.69 MI W OF SR 7 (Lat: 41.229631,  Lng: -80.600619),  Route carried "on" structure: State highway 82,  Year Built: 1957,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 3.01m (9.88ft),  Average Daily Traffic: 6,164 (year 2015),  Truck Traffic: 13%,  Average Future Daily Traffic: 8,556 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: LITTLE YANKEE RUN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 40.974,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.4m (37.4ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7805012,  Location: 1.69 MI W OF SR 7 (Lat: 41.229331,  Lng: -80.600561),  Route carried "on" structure: State highway 82,  Year Built: 1957,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 3.01m (9.88ft),  Average Daily Traffic: 6,164 (year 2015),  Truck Traffic: 13%,  Average Future Daily Traffic: 8,556 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: LITTLE YANKEE RUN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 40.974,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.4m (37.4ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7836007,  Location: 0.1 MI. W. OF C.H. 167-C (Lat: 41.235939,  Lng: -80.602389),  Route carried "on" structure: County highway C0329,  Year Built: 1942,  Status: Open,  Structure Length: 1.62m (5.31ft),  Average Daily Traffic: 3,287 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,562 (year 2035),  Design Load: H 20,  Features Intersected: LITTLE YANKEE RUN,  Facility Carried by Structure: WARREN SHARON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.129,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 8.3m (27.2ft),  Out-to-Out Width: 8.3m (27.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 7840926,  Location: 0.9 MI. E. OF S.R. 7 (Lat: 41.260639,  Lng: -80.553469),  Route carried "on" structure: County highway C169A,  Year Built: 1982,  Status: Open,  Structure Length: 2.10m (6.89ft),  Average Daily Traffic: 491 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 682 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: YANKEE RUN,  Facility Carried by Structure: COUNTY ROAD 169-A
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.225,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Fair,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 7840969,  Location: 0.5 MI.E.CR 43 (Lat: 41.250639,  Lng: -80.605631),  Route carried "on" structure: County highway C168A,  Year Built: 1991,  Status: Open,  Structure Length: 4.91m (16.11ft),  Average Daily Traffic: 613 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 851 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: NORFOLK SOUTHERN RR,  Facility Carried by Structure: MERWIN CHASE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.193,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7841094,  Location: 2700 FEET WEST OF TH321 (Lat: 41.213739,  Lng: -80.592439),  Route carried "on" structure: County highway C174B,  Year Built: 2006,  Status: Open,  Structure Length: 1.98m (6.50ft),  Average Daily Traffic: 778 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,080 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: LITTLE YANKEE RUN,  Facility Carried by Structure: STEWART SHARON RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.048,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 7841132,  Location: 2100 FT SOUTH OF CH329 (Lat: 41.230000,  Lng: -80.600939),  Route carried "on" structure: County highway C0167,  Year Built: 1951,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 485 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 673 (year 2035),  Design Load: H 15,  Features Intersected: LITTLE YANKEE RUN,  Facility Carried by Structure: ALBRIGHT MCKAY RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.016,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 5.8m (19.0ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.5m (41.0ft),  Curb-To-Curb Width: 5.3m (17.4ft),  Out-to-Out Width: 5.4m (17.7ft)

Condition: Deck: Good,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 71.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Critical Feature Inspection Date: April 2021,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 7804865,  Location: 1.74 MI W OF SR 7 (Lat: 41.229711,  Lng: -80.601400),  Route carried "under" structure: County highway 167,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 485 (year 2015),  Truck Traffic: 7%,  Features Intersected: SR 82,  Facility Carried by Structure: SR 82
Minimum Vertical Clearance: 4.80m (15.75ft),  Kilometerpoint: 0.740,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.2m (49.9ft)

Find on map >>   Show street view

Structure Number: 7804954,  Location: 1.74 MI W OF SR 7 (Lat: 41.229431,  Lng: -80.601519),  Route carried "under" structure: County highway 167,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 485 (year 2015),  Truck Traffic: 7%,  Features Intersected: SR 82,  Facility Carried by Structure: SR 82
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 77.249,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.2m (49.9ft)