  • 15Number of bridges
  • 167ft / 51.5mTotal length
  • $1,164,000Total costs
  • 14,450Total average daily traffic
  • 1,846Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Buncombe
  • No street view available for this location

New bridges in Buncombe, IL - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 31930-1939
  • 21960-1969
  • 41970-1979
  • 11980-1989
  • 21990-1999
  • 12000-2009
  • 12010-2019
Reconstructed bridges in Buncombe, IL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11980-1989
  • 01990-1999
  • 02000-2009
  • 12010-2019
Average Bridge Daily Traffic in Buncombe, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 8.3%Very good
  • 58.3%Good
  • 25.0%Satisfactory
  • 8.3%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 16.7%Very good
  • 41.7%Good
  • 16.7%Satisfactory
  • 16.7%Fair
  • 8.3%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 41.7%Very good
  • 16.7%Good
  • 41.7%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 21.4%Very good
  • 42.9%Good
  • 35.7%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Good
  • 50.0%Satisfactory
Find on map >>   Show street view

Structure Number: 440011,  Location: .5 MI S. OF W VIENNA (Lat: 37.421431,  Lng: -88.977089),  Route carried "on" structure: State highway 37,  Year Built: 1931,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 14.02m (46.00ft),  Average Daily Traffic: 1,650 (year 2021),  Truck Traffic: 16%,  Average Future Daily Traffic: 1,741 (year 2032),  Design Load: HS 20,  Features Intersected: CACHE RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 50.693,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 5 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 65.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: August 2020,  Underwater Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 440014,  Location: 1 MI W OF W VIENNA (Lat: 37.427919,  Lng: -88.994183),  Route carried "on" structure: State highway 146,  Year Built: 1930,  Year Reconstructed: 2010,  Status: Open,  Structure Length: 11.74m (38.52ft),  Average Daily Traffic: 2,600 (year 2021),  Truck Traffic: 13%,  Average Future Daily Traffic: 2,611 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: CACHE RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 63.181,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 6,  Length of Maximum Span: 15.4m (50.5ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 81.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 11.73m (38.48ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Bridge Improvement Cost: $776,000,  Roadway Improvement Cost: $78,000,  Total Project Cost: $1,164,000,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 440059,  Location: 1.2 MI E UNION CO (Lat: 37.437653,  Lng: -89.023953),  Route carried "on" structure: State highway 146,  Year Built: 2008,  Status: Open,  Structure Length: 2.81m (9.22ft),  Average Daily Traffic: 2,600 (year 2021),  Truck Traffic: 13%,  Average Future Daily Traffic: 2,611 (year 2032),  Design Load: HS 20,  Features Intersected: BUCK RUN CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.204,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 27.3m (89.6ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 76.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 442008,  Location: 1.9M E.UNION CO. (Lat: 37.433061,  Lng: -89.012036),  Route carried "on" structure: State highway 146,  Year Built: 1930,  Status: Posted for load,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 2,600 (year 2021),  Truck Traffic: 13%,  Average Future Daily Traffic: 2,611 (year 2032),  Features Intersected: TRIB OF BUCK RUN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 61.379,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 29.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 17.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: Febuary 2022
Find on map >>   Show street view

Structure Number: 443003,  Location: NE1/4 SEC 8 T12S,R2E (Lat: 37.492214,  Lng: -89.004058),  Route carried "on" structure: County highway ,  Year Built: 1962,  Status: Open,  Structure Length: 3.35m (10.99ft),  Average Daily Traffic: 175 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 163 (year 2032),  Design Load: HS 15,  Features Intersected: LICK CREEK OVERFLOW,  Facility Carried by Structure: FAS 924
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.747,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 7.5m (24.6ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 443004,  Location: NW1/4 SEC 9 T12S,R2E (Lat: 37.491383,  Lng: -89.003308),  Route carried "on" structure: County highway ,  Year Built: 1962,  Status: Open,  Structure Length: 4.11m (13.48ft),  Average Daily Traffic: 175 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 163 (year 2032),  Design Load: HS 15,  Features Intersected: LICK CREEK,  Facility Carried by Structure: FAS 924
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.860,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 43.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 26.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 443054,  Location: E 1/2 SEC 6 T12S R2E (Lat: 37.500414,  Lng: -89.025294),  Route carried "on" structure: County highway ,  Year Built: 1974,  Status: Open,  Structure Length: 2.19m (7.19ft),  Average Daily Traffic: 125 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 245 (year 2032),  Design Load: HS 15,  Features Intersected: LICK CR,  Facility Carried by Structure: FAS 924
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.044,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.9m (25.9ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 443061,  Location: SW1/4 SEC13 T12S,R2E (Lat: 37.466667,  Lng: -88.942739),  Route carried "on" structure: County highway ,  Year Built: 1978,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 225 (year 2021),  Truck Traffic: 18%,  Average Future Daily Traffic: 245 (year 2032),  Design Load: HS 20,  Features Intersected: DUTCHMAN CR. TRIB.,  Facility Carried by Structure: TR 111
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.301,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.2m (17.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.0m (45.9ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Serious,  Superstructure: Serious,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 64.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 443062,  Location: NW1/4 SEC20 T12S,R2E (Lat: 37.464125,  Lng: -89.018411),  Route carried "on" structure: County highway ,  Year Built: 1979,  Status: Open,  Structure Length: 2.85m (9.35ft),  Average Daily Traffic: 25 (year 2021),  Truck Traffic: 12%,  Average Future Daily Traffic: 82 (year 2032),  Design Load: HS 20,  Features Intersected: CACHE RIVER,  Facility Carried by Structure: TR 101
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.734,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.2m (30.2ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 443086,  Location: SW1/4 SEC13 T12S,R2E (Lat: 37.471347,  Lng: -88.940411),  Route carried "on" structure: County highway ,  Year Built: 1984,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 100 (year 2021),  Truck Traffic: 11%,  Average Future Daily Traffic: 109 (year 2032),  Design Load: HS 20,  Features Intersected: TRIB TO DUTCHMAN CR,  Facility Carried by Structure: TR 70
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.488,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.0m (23.0ft),  Curb-To-Curb Width: 7.8m (25.6ft),  Out-to-Out Width: 8.0m (26.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 443108,  Location: 1 MI NE BUNCOMBE (Lat: 37.489669,  Lng: -88.951667),  Route carried "on" structure: County highway ,  Year Built: 1992,  Status: Open,  Structure Length: 2.48m (8.14ft),  Average Daily Traffic: 100 (year 2021),  Truck Traffic: 11%,  Average Future Daily Traffic: 109 (year 2032),  Design Load: HS 20,  Features Intersected: GRASSHOPPER CREEK,  Facility Carried by Structure: TR 70
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.945,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2019,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 443117,  Location: 2 MI W BUNCOMBE (Lat: 37.478947,  Lng: -89.016122),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 1.87m (6.14ft),  Average Daily Traffic: 25 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 82 (year 2032),  Design Load: HS 20,  Features Intersected: LICK CREEK,  Facility Carried by Structure: TR 89-ALLEN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.207,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 7.5m (24.6ft),  Out-to-Out Width: 7.5m (24.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 44313,  Location: 1.7 MI W OF BUNCOMBE (Lat: 37.464325,  Lng: -89.015158),  Route carried "on" structure: County highway ,  Year Built: 2013,  Status: Open,  Structure Length: 2.03m (6.66ft),  Average Daily Traffic: 25 (year 2021),  Truck Traffic: 12%,  Average Future Daily Traffic: 82 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: UNNAMED TRIBUTARY,  Facility Carried by Structure: PLEASANT GROVE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.023,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.4m (63.6ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 445,  Location: SW1/4 SEC14 T12S,R2E (Lat: 37.471275,  Lng: -88.950622),  Route carried "on" structure: County highway ,  Year Built: 1977,  Status: Open,  Structure Length: 1.08m (3.54ft),  Average Daily Traffic: 225 (year 2021),  Truck Traffic: 18%,  Average Future Daily Traffic: 245 (year 2032),  Design Load: HS 20,  Features Intersected: DRAINAGE DITCH,  Facility Carried by Structure: TWP RD 111
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.368,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Aluminum, Iron,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.2m (17.1ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 449901,  Location: WEST VIENNA (Lat: 37.427567,  Lng: -88.970172),  Route carried "under" structure: State highway 146,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 3,800 (year 2021),  Truck Traffic: 11%,  Features Intersected: ILL. 146,  Facility Carried by Structure: C.&E.I. R.R.
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 65.289,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.2m (49.9ft)