Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Byron, Wisconsin (WI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 16Number of bridges
  • 154ft / 46.5mTotal length
  • $239,000Total costs
  • 153,428Total average daily traffic
  • 13,968Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Byron
  • No street view available for this location

New bridges in Byron, WI - historical statistics
  • New bridges - historical statistics
  • 51950-1959
  • 11970-1979
  • 81990-1999
  • 22000-2009
Average Bridge Daily Traffic in Byron, WI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 60.0%Good
  • 10.0%Satisfactory
  • 30.0%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 40.0%Very good
  • 10.0%Good
  • 30.0%Satisfactory
  • 10.0%Fair
  • 10.0%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 10.0%Very good
  • 40.0%Good
  • 30.0%Satisfactory
  • 20.0%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 33.3%Excellent
  • 33.3%Very good
  • 33.3%Good
Find on map >>   Show street view

Structure Number: B200004,  Location: 1.5M W JCT CTH G (Lat: 43.891961,  Lng: -88.232808),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Open,  Structure Length: 0.99m (3.25ft),  Average Daily Traffic: 555 (year 2019),  Average Future Daily Traffic: 610 (year 2040),  Design Load: HS 20,  Features Intersected: BR MANITOWOC RIVER,  Facility Carried by Structure: CTH Q
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.0m (29.5ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Very good,  Operating Rating: 75.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B200009,  Location: 3.0M N JCT STH 49 (Lat: 43.660556,  Lng: -88.441389),  Route carried "on" structure: US 41,  Year Built: 1953,  Year Reconstructed: 1987,  Status: Open,  Structure Length: 2.77m (9.09ft),  Average Daily Traffic: 15,500 (year 2021),  Truck Traffic: 10%,  Average Future Daily Traffic: 20,735 (year 2040),  Design Load: H 20,  Features Intersected: CTH F
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.7m (35.1ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 17.9m (58.7ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 78.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B20002,  Location: 0.5M E JCT CTH K (Lat: 43.769014,  Lng: -88.380164),  Route carried "on" structure: County highway ,  Year Built: 1955,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 2,834 (year 2019),  Average Future Daily Traffic: 3,117 (year 2040),  Design Load: H 15,  Features Intersected: TAYCHEEDAH CREEK,  Facility Carried by Structure: CTH T
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.1m (33.1ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 37.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.49m (4.89ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: October 2021,  Bridge Improvement Cost: $159,000,  Roadway Improvement Cost: $15,000,  Total Project Cost: $239,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: B200024,  Location: 2.0M S JCT CTH B (Lat: 43.660556,  Lng: -88.441742),  Route carried "on" structure: Interstate 41,  Year Built: 1957,  Year Reconstructed: 1987,  Status: Open,  Structure Length: 3.09m (10.14ft),  Average Daily Traffic: 15,500 (year 2021),  Truck Traffic: 10%,  Average Future Daily Traffic: 20,735 (year 2040),  Design Load: HS 20,  Features Intersected: CTH F
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.6m (38.1ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 17.9m (58.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 68.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B20006,  Location: 1.0M N JCT CTH OO (Lat: 43.821667,  Lng: -88.523333),  Route carried "on" structure: City street ,  Year Built: 1973,  Status: Open,  Structure Length: 7.25m (23.79ft),  Average Daily Traffic: 200 (year 2021),  Average Future Daily Traffic: 150 (year 2040),  Design Load: H 20,  Features Intersected: IH 41,  Facility Carried by Structure: LRD TOWN LINE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.7m (117.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: B200064,  Location: 0.3M W JCT STH 175 (Lat: 43.660700,  Lng: -88.456553),  Route carried "on" structure: County highway ,  Year Built: 1999,  Status: Open,  Structure Length: 4.55m (14.93ft),  Average Daily Traffic: 490 (year 2019),  Average Future Daily Traffic: 539 (year 2040),  Design Load: HS 20,  Features Intersected: CN RR,  Facility Carried by Structure: CTH F
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.8m (55.1ft),  Curb-To-Curb Width: 9.5m (31.2ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 73.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B200066,  Location: 0.5M E JCT STH 175 (Lat: 43.638611,  Lng: -88.441767),  Route carried "on" structure: County highway ,  Year Built: 1995,  Status: Open,  Structure Length: 6.26m (20.54ft),  Average Daily Traffic: 510 (year 2021),  Average Future Daily Traffic: 850 (year 2040),  Design Load: HS 20,  Features Intersected: IH 41,  Facility Carried by Structure: CTH Y CAMPBELL R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.5m (100.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 70.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B200067,  Location: 0.5M E JCT STH 175 (Lat: 43.689550,  Lng: -88.442531),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 6.51m (21.36ft),  Average Daily Traffic: 3,300 (year 2021),  Average Future Daily Traffic: 3,800 (year 2040),  Design Load: HS 20,  Features Intersected: IH 41,  Facility Carried by Structure: CTH B
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.7m (104.0ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 20.4m (66.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 62.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B200068,  Location: 0.5M E JCT STH 175 (Lat: 43.711450,  Lng: -88.442731),  Route carried "on" structure: City street ,  Year Built: 1996,  Status: Open,  Structure Length: 6.26m (20.54ft),  Average Daily Traffic: 560 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 619 (year 2040),  Design Load: HS 20,  Features Intersected: IH 41,  Facility Carried by Structure: LRD LOST ARROW RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.5m (100.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 70.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B203832,  Location: AT (Lat: 43.737117,  Lng: -88.449850),  Route carried "on" structure: State highway 175,  Year Built: 2008,  Status: Open,  Structure Length: 7.13m (23.39ft),  Average Daily Traffic: 3,900 (year 2021),  Average Future Daily Traffic: 5,580 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: USH 151
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 19.8m (65.0ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.1m (115.2ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 20.0m (65.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 78.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B203837,  Location: 1.2M W OF STH 175 (Lat: 43.697306,  Lng: -88.475167),  Route carried "on" structure: County highway ,  Year Built: 2009,  Status: Open,  Structure Length: 0.66m (2.17ft),  Average Daily Traffic: 819 (year 2019),  Average Future Daily Traffic: 900 (year 2035),  Design Load: HL 93,  Features Intersected: PARSONS CREEK,  Facility Carried by Structure: CTH B
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft)

Condition: Channel: Excellent,  Culverts: Excellent,  Operating Rating: 50.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B200009,  Location: 0.5M E JCT STH 175 (Lat: 43.660556,  Lng: -88.441389),  Route carried "under" structure: County highway ,  Year Built: 1953,  Structure Length: 0. m,  Average Daily Traffic: 430 (year 2021),  Features Intersected: CTH F,  Facility Carried by Structure: USH 41 NB
Minimum Vertical Clearance: 4.61m (15.12ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 10.7m (35.1ft)

Find on map >>   Show street view

Structure Number: B200024,  Location: 0.5M E JCT STH 175 (Lat: 43.660556,  Lng: -88.441742),  Route carried "under" structure: County highway ,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 430 (year 2019),  Features Intersected: CTH F,  Facility Carried by Structure: IH 41 SB
Minimum Vertical Clearance: 4.92m (16.14ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 11.6m (38.1ft)

Find on map >>   Show street view

Structure Number: B200066,  Location: 1.4M N JCT STH 49 (Lat: 43.638611,  Lng: -88.441767),  Route carried "under" structure: Interstate 41,  Year Built: 1995,  Structure Length: 0. m,  Average Daily Traffic: 31,000 (year 2021),  Truck Traffic: 10%,  Features Intersected: IH 41,  Facility Carried by Structure: CTH Y CAMPBELL R
Minimum Vertical Clearance: 4.96m (16.27ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.5m (100.1ft)

Find on map >>   Show street view

Structure Number: B200067,  Location: 2.4M N JCT CTH F (Lat: 43.689550,  Lng: -88.442531),  Route carried "under" structure: Interstate 41,  Year Built: 1996,  Structure Length: 0. m,  Average Daily Traffic: 38,700 (year 2021),  Truck Traffic: 10%,  Features Intersected: IH 41,  Facility Carried by Structure: CTH B
Minimum Vertical Clearance: 5.14m (16.86ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.7m (104.0ft)

Find on map >>   Show street view

Structure Number: B200068,  Location: 1.6M N JCT CTH B (Lat: 43.711450,  Lng: -88.442731),  Route carried "under" structure: Interstate 41,  Year Built: 1996,  Structure Length: 0. m,  Average Daily Traffic: 38,700 (year 2021),  Truck Traffic: 10%,  Features Intersected: IH 41,  Facility Carried by Structure: LRD LOST ARROW RD
Minimum Vertical Clearance: 5.00m (16.40ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.5m (100.1ft)

Discuss Byron, Wisconsin (WI) on our hugely popular Wisconsin forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.