  • National Bridge Inventory (NBI) Statistics
  • 32Number of bridges
  • 315ft / 96.3mTotal length
  • 459,110Total average daily traffic
  • 64,684Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Clyde
  • No street view available for this location

New bridges in Clyde, NC - historical statistics
  • New bridges - historical statistics
  • 231960-1969
  • 31970-1979
  • 21990-1999
  • 32000-2009
  • 12010-2019
Reconstructed bridges in Clyde, NC - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21980-1989
  • 11990-1999
  • 22000-2009
  • 12010-2019
Average Bridge Daily Traffic in Clyde, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 23.5%Good
  • 58.8%Satisfactory
  • 17.6%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 11.8%Very good
  • 35.3%Good
  • 41.2%Satisfactory
  • 11.8%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 5.9%Very good
  • 35.3%Good
  • 29.4%Satisfactory
  • 17.6%Fair
  • 11.8%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 87.5%Good
  • 12.5%Satisfactory
Find on map >>   Show street view

Structure Number: 870016,  Location: .1 MI.E.JCT.NC215 (Lat: 35.498950,  Lng: -82.873028),  Route carried "on" structure: State highway 1869,  Year Built: 1977,  Status: Open,  Structure Length: 6.40m (21.00ft),  Average Daily Traffic: 1,600 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 3,200 (year 2040),  Design Load: HS 15,  Features Intersected: PIGEON RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.0m (68.9ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: Febuary 2021,  Underwater Inspection Date: March 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 870069,  Location: .07 MI.S.JCT.SR1371 (Lat: 35.534603,  Lng: -82.959442),  Route carried "on" structure: State highway 209,  Year Built: 1995,  Status: Open,  Structure Length: 5.18m (16.99ft),  Average Daily Traffic: 8,700 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 17,400 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: RICHLAND CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.5m (60.7ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 12.6m (41.3ft),  Out-to-Out Width: 13.7m (44.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 70.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 870073,  Location: 1.0 MI.S.JCT.I-40 (Lat: 35.528719,  Lng: -82.924692),  Route carried "on" structure: Ramp US 74,  Year Built: 1961,  Year Reconstructed: 2013,  Status: Open,  Structure Length: 8.56m (28.08ft),  Average Daily Traffic: 43,500 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 87,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US19,23,74
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.309,  Lanes on structure: 4,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 74),  Owner: State Highway Agency,  Approaching Roadway Width: 21.3m (69.9ft),  Skew: 23 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 23.7m (77.8ft),  Curb-To-Curb Width: 21.4m (70.2ft),  Out-to-Out Width: 23.1m (75.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 74.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 870095,  Location: .3 MI.N.JCT.US19,23,74 (Lat: 35.532831,  Lng: -82.921933),  Route carried "on" structure: Ramp US 74,  Year Built: 1961,  Year Reconstructed: 1989,  Status: Open,  Structure Length: 4.02m (13.19ft),  Average Daily Traffic: 27,000 (year 2014),  Truck Traffic: 12%,  Average Future Daily Traffic: 54,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SOUTHERN RAILROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 74),  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 31 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.8m (51.8ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 18.6m (61.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Poor,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 870114,  Location: 0.5 MI.N.JCT.US19,23 (Lat: 35.534511,  Lng: -82.920889),  Route carried "on" structure: Ramp US 74,  Year Built: 1961,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 12.19m (39.99ft),  Average Daily Traffic: 27,000 (year 2014),  Truck Traffic: 12%,  Average Future Daily Traffic: 54,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: PIGEONRIVER,SR1513,1523
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 74),  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 17.8m (58.4ft),  Out-to-Out Width: 18.6m (61.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 66.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: December 2020,  Underwater Inspection Date: May 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 870126,  Location: 1 MI.N.JCT.US19,23 (Lat: 35.541744,  Lng: -82.917992),  Route carried "on" structure: Ramp US 74,  Year Built: 1961,  Year Reconstructed: 2015,  Status: Open,  Structure Length: 7.92m (25.98ft),  Average Daily Traffic: 32,000 (year 2016),  Truck Traffic: 12%,  Average Future Daily Traffic: 64,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I-40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 74),  Owner: State Highway Agency,  Approaching Roadway Width: 15.5m (50.9ft),  Skew: 32 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 22.5m (73.8ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 16.2m (53.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 60.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 870211,  Location: .5 MI.E.JCT.NC209 (Lat: 35.548056,  Lng: -82.945411),  Route carried "on" structure: State highway 1519,  Year Built: 2009,  Status: Open,  Structure Length: 4.87m (15.98ft),  Average Daily Traffic: 1,000 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 2,000 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: RICHLAND CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.1m (16.7ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.1m (88.9ft),  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 57.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2021,  Underwater Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 870212,  Location: .01 MI.N.JCT.SR1519 (Lat: 35.549042,  Lng: -82.939497),  Route carried "on" structure: State highway 1533,  Year Built: 1965,  Status: Posted for load,  Structure Length: 5.48m (17.98ft),  Average Daily Traffic: 600 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,200 (year 2040),  Design Load: H 15,  Features Intersected: PIGEON RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.9m (58.7ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 39.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: December 2020,  Underwater Inspection Date: December 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 870231,  Location: 1.7 MI.E.JCT.NC209 (Lat: 35.550233,  Lng: -82.938931),  Route carried "on" structure: Interstate 40,  Year Built: 1974,  Status: Open,  Structure Length: 4.66m (15.29ft),  Average Daily Traffic: 14,250 (year 2019),  Truck Traffic: 16%,  Average Future Daily Traffic: 28,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR1513
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.909,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 40),  Owner: State Highway Agency,  Approaching Roadway Width: 11.2m (36.7ft),  Skew: 11 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 71.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 870233,  Location: .08 MI.S.JCT.SR1634 (Lat: 35.544681,  Lng: -82.909875),  Route carried "on" structure: State highway 1534,  Year Built: 1961,  Status: Open,  Structure Length: 7.28m (23.88ft),  Average Daily Traffic: 670 (year 2014),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,340 (year 2040),  Design Load: HS 15,  Features Intersected: I-40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 68.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 870235,  Location: .4 MI.S.JCT.SR1536 (Lat: 35.545564,  Lng: -82.903828),  Route carried "on" structure: State highway 1535,  Year Built: 1961,  Status: Open,  Structure Length: 6.55m (21.49ft),  Average Daily Traffic: 1,000 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 2,000 (year 2040),  Design Load: HS 15,  Features Intersected: I-40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 16.1m (52.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 55.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 870236,  Location: 1.8 MI.E.JCT.SR1660 (Lat: 35.548919,  Lng: -82.885839),  Route carried "on" structure: Interstate 40,  Year Built: 1961,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 4.45m (14.60ft),  Average Daily Traffic: 27,500 (year 2019),  Truck Traffic: 16%,  Average Future Daily Traffic: 55,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR1513
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.930,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 40),  Owner: State Highway Agency,  Approaching Roadway Width: 23.1m (75.8ft),  Skew: 33 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 22.3m (73.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Poor,  Operating Rating: 58.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 870239,  Location: 1.2 MI.W.JCT.NC215 (Lat: 35.552169,  Lng: -82.872553),  Route carried "on" structure: Interstate 40,  Year Built: 1961,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 4.29m (14.07ft),  Average Daily Traffic: 55,000 (year 2019),  Truck Traffic: 16%,  Average Future Daily Traffic: 110,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR1550
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.144,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 40),  Owner: State Highway Agency,  Approaching Roadway Width: 24.9m (81.7ft),  Skew: 32 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 21.7m (71.2ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 87028,  Location: 1 MI.W.JCT.SR1551 (Lat: 35.550456,  Lng: -82.866361),  Route carried "on" structure: State highway 1550,  Year Built: 1964,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 1,200 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 2,400 (year 2040),  Features Intersected: THICKETY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 6.4m (21.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 56.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 870321,  Location: 0.1 MI. N. JCT. SR1819 (Lat: 35.526339,  Lng: -82.907189),  Route carried "on" structure: State highway 1820,  Year Built: 2015,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 440 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 880 (year 2040),  Design Load: HL 93,  Features Intersected: CONNER MILL BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 50.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: 870406,  Location: 75 FT.S.JCT.SR1513 (Lat: 35.535025,  Lng: -82.912069),  Route carried "on" structure: State highway 1523,  Year Built: 1967,  Status: Open,  Structure Length: 5.57m (18.27ft),  Average Daily Traffic: 2,900 (year 2014),  Truck Traffic: 7%,  Average Future Daily Traffic: 5,800 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: PIGEON RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.2m (59.7ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 14.9m (48.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 78.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: December 2020,  Underwater Inspection Date: December 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1970201,  Location: .2 MI.S.JCT.SR1146 (Lat: 36.113569,  Lng: -80.588478),  Route carried "on" structure: US 421,  Year Built: 1991,  Status: Open,  Structure Length: 4.05m (13.29ft),  Average Daily Traffic: 12,000 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 24,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR1710
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 77.054,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 21),  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Skew: 10 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 72.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1970208,  Location: .6 MI.N.JCT.SR1314 (Lat: 36.138792,  Lng: -80.865831),  Route carried "on" structure: US 421,  Year Built: 2005,  Status: Open,  Structure Length: 3.32m (10.89ft),  Average Daily Traffic: 7,000 (year 2015),  Truck Traffic: 14%,  Average Future Daily Traffic: 14,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR1300
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 81.809,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 21),  Owner: State Highway Agency,  Approaching Roadway Width: 11.2m (36.7ft),  Skew: 12 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 11.4m (37.4ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 57.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 870073,  Location: 1.0 MI.S.JCT.I-40 (Lat: 35.528719,  Lng: -82.924692),  Route carried "under" structure: US 19,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 8,000 (year 2016),  Truck Traffic: 12%,  Features Intersected: US74
Minimum Vertical Clearance: 4.49m (14.73ft),  Kilometerpoint: 32.309,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.7m (77.8ft)

Find on map >>   Show street view

Structure Number: 870073,  Location: 1.0 MI.S.JCT.I-40 (Lat: 35.528719,  Lng: -82.924692),  Route carried "under" structure: US 19,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 9,750 (year 2018),  Truck Traffic: 12%,  Features Intersected: US74
Minimum Vertical Clearance: 4.49m (14.73ft),  Kilometerpoint: 32.309,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.7m (77.8ft)

Find on map >>   Show street view

Structure Number: 870073,  Location: 1.0 MI.S.JCT.I-40 (Lat: 35.528719,  Lng: -82.924692),  Route carried "under" structure: US 19,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 9,750 (year 2018),  Truck Traffic: 12%,  Features Intersected: US74
Minimum Vertical Clearance: 4.77m (15.65ft),  Kilometerpoint: 32.309,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.7m (77.8ft)

Find on map >>   Show street view

Structure Number: 870114,  Location: 0.5 MI.N.JCT.US19,23 (Lat: 35.534511,  Lng: -82.920889),  Route carried "under" structure: State highway 1513,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 1,200 (year 2014),  Truck Traffic: 7%,  Features Intersected: US74
Minimum Vertical Clearance: 12.29m (40.32ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 870126,  Location: 1 MI.N.JCT.US19,23 (Lat: 35.541744,  Lng: -82.917992),  Route carried "under" structure: Interstate 40,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 28,500 (year 2017),  Truck Traffic: 16%,  Features Intersected: US74
Minimum Vertical Clearance: 5.87m (19.26ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.5m (73.8ft)

Find on map >>   Show street view

Structure Number: 870126,  Location: 1 MI.N.JCT.US19,23 (Lat: 35.541744,  Lng: -82.917992),  Route carried "under" structure: Interstate 40,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 28,500 (year 2017),  Truck Traffic: 16%,  Features Intersected: US74
Minimum Vertical Clearance: 6.97m (22.87ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.5m (73.8ft)

Find on map >>   Show street view

Structure Number: 870231,  Location: 1.7 MI.E.JCT.NC209 (Lat: 35.550233,  Lng: -82.938931),  Route carried "under" structure: State highway 1513,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 600 (year 2016),  Truck Traffic: 7%,  Features Intersected: I-40 EBL
Minimum Vertical Clearance: 8.86m (29.07ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>   Show street view

Structure Number: 870233,  Location: .08 MI.S.JCT.SR1634 (Lat: 35.544681,  Lng: -82.909875),  Route carried "under" structure: Interstate 40,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 25,000 (year 2015),  Truck Traffic: 16%,  Features Intersected: SR1534
Minimum Vertical Clearance: 4.90m (16.08ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>   Show street view

Structure Number: 870233,  Location: .08 MI.S.JCT.SR1634 (Lat: 35.544681,  Lng: -82.909875),  Route carried "under" structure: Interstate 40,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 25,000 (year 2015),  Truck Traffic: 16%,  Features Intersected: SR1534
Minimum Vertical Clearance: 4.84m (15.88ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>   Show street view

Structure Number: 870235,  Location: .4 MI.S.JCT.SR1536 (Lat: 35.545564,  Lng: -82.903828),  Route carried "under" structure: Interstate 40,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 28,500 (year 2017),  Truck Traffic: 16%,  Features Intersected: SR1535
Minimum Vertical Clearance: 5.25m (17.22ft),  Kilometerpoint: 8.595,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.1m (52.8ft)

Find on map >>   Show street view

Structure Number: 870235,  Location: .4 MI.S.JCT.SR1536 (Lat: 35.545564,  Lng: -82.903828),  Route carried "under" structure: Interstate 40,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 28,500 (year 2017),  Truck Traffic: 16%,  Features Intersected: SR1535
Minimum Vertical Clearance: 5.00m (16.40ft),  Kilometerpoint: 8.595,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.1m (52.8ft)

Find on map >>   Show street view

Structure Number: 870236,  Location: 1.8 MI.E.JCT.SR1660 (Lat: 35.548919,  Lng: -82.885839),  Route carried "under" structure: State highway 1513,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 630 (year 2016),  Truck Traffic: 7%,  Features Intersected: I-40
Minimum Vertical Clearance: 4.44m (14.57ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.8m (51.8ft)

Find on map >>   Show street view

Structure Number: 870239,  Location: 1.2 MI.W.JCT.NC215 (Lat: 35.552169,  Lng: -82.872553),  Route carried "under" structure: State highway 1550,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 620 (year 2016),  Truck Traffic: 7%,  Features Intersected: I-40
Minimum Vertical Clearance: 4.44m (14.57ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.2m (49.9ft)

Find on map >>   Show street view

Structure Number: 1970208,  Location: .6 MI.N.JCT.SR1314 (Lat: 36.138792,  Lng: -80.865831),  Route carried "under" structure: State highway 1300,  Year Built: 2005,  Structure Length: 0. m,  Average Daily Traffic: 1,200 (year 2015),  Truck Traffic: 6%,  Features Intersected: US421 NBL
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 81.809,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.5m (50.9ft)