Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for De Beque, Colorado (CO)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 33Number of bridges
  • 564ft / 172mTotal length
  • $3,678,000Total costs
  • 273,671Total average daily traffic
  • 40,893Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for De Beque
  • No street view available for this location

New bridges in De Beque, CO - historical statistics
  • New bridges - historical statistics
  • 21940-1949
  • 21950-1959
  • 11960-1969
  • 251980-1989
  • 11990-1999
  • 22000-2009
Reconstructed bridges in De Beque, CO - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 01960-1969
  • 11970-1979
  • 11980-1989
  • 01990-1999
  • 12000-2009
Average Bridge Daily Traffic in De Beque, CO
Average Bridge Truck Traffic in De Beque, CO
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 5.3%Very good
  • 78.9%Good
  • 5.3%Satisfactory
  • 10.5%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 68.4%Good
  • 31.6%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 5.3%Very good
  • 42.1%Good
  • 47.4%Satisfactory
  • 5.3%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 4.5%Very good
  • 40.9%Good
  • 27.3%Satisfactory
  • 22.7%Fair
  • 4.5%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Good
  • 30.0%Satisfactory
  • 20.0%Fair
Find on map >>   Show street view

Structure Number: G-03-P,  Location: 17 MI W OF PARACHUTE (Lat: 39.270122,  Lng: -108.251272),  Route carried "on" structure: Interstate 70A,  Year Built: 1982,  Status: Open,  Structure Length: 13.33m (43.73ft),  Average Daily Traffic: 8,500 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 10,880 (year 2040),  Design Load: HS 20,  Features Intersected: COLORADO RIVER,  Facility Carried by Structure: I 70 ML WBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 92.096,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 14 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 32.5m (106.6ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 64.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: August 2020,  Underwater Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: G-03-Q,  Location: 9.2 Miles W Mesa Garfield (Lat: 39.266339,  Lng: -108.252922),  Route carried "on" structure: Interstate 70A,  Year Built: 1982,  Status: Open,  Structure Length: 18.72m (61.42ft),  Average Daily Traffic: 8,500 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 10,880 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: COLORADO RIVER OVFLW,  Facility Carried by Structure: I 70 ML WBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 91.639,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 15 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 41.0m (134.5ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 56.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: G-04-A,  Location: 1 MI E. OF DEBEQUE (Lat: 39.338283,  Lng: -108.193958),  Route carried "on" structure: US 6M,  Year Built: 1945,  Status: Open,  Structure Length: 12.41m (40.72ft),  Average Daily Traffic: 1,200 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,220 (year 2040),  Design Load: HS 20,  Features Intersected: COLORADO RIVER,  Facility Carried by Structure: US 6 ML
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 1.936,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 62.0m (203.4ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 32.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Critical Feature Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: G-04-AA,  Location: 11 MI W OF PARACHUTE (Lat: 39.338189,  Lng: -108.193114),  Route carried "on" structure: Interstate 70A,  Year Built: 1980,  Status: Open,  Structure Length: 12.27m (40.26ft),  Average Daily Traffic: 9,000 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 11,790 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: COLORADO RIVER,  Facility Carried by Structure: I 70 ML EBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 101.400,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 30.0m (98.4ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.6m (44.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Fair,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2020,  Underwater Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: G-04-AB,  Location: 11.4 MI W OF PARACHUTE (Lat: 39.338233,  Lng: -108.193428),  Route carried "on" structure: Interstate 70A,  Year Built: 1980,  Status: Open,  Structure Length: 12.27m (40.26ft),  Average Daily Traffic: 9,000 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 11,790 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: COLORADO RIVER,  Facility Carried by Structure: I 70 ML WBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 101.398,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 29.9m (98.1ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 41.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2020,  Underwater Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: G-04-AC,  Location: 14.1 MI E OF JCT SH 65 (Lat: 39.341733,  Lng: -108.191933),  Route carried "on" structure: Interstate 70A,  Year Built: 1980,  Status: Open,  Structure Length: 5.52m (18.11ft),  Average Daily Traffic: 9,000 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 11,790 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: COLORADO RIVER OVFLW,  Facility Carried by Structure: I 70 ML EBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 101.807,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 26.8m (87.9ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.6m (44.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 33.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: G-04-AD,  Location: 11.1MI W OF PARACHUTE (Lat: 39.341656,  Lng: -108.192292),  Route carried "on" structure: Interstate 70A,  Year Built: 1980,  Status: Open,  Structure Length: 5.52m (18.11ft),  Average Daily Traffic: 9,000 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 11,790 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: COLORADO RIVER OVFLW,  Facility Carried by Structure: I 70 ML WBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 101.791,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 26.8m (87.9ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.6m (44.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 35.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: G-04-AE,  Location: DEBEQUE INTER. (Lat: 39.324364,  Lng: -108.206286),  Route carried "on" structure: City street ,  Year Built: 1980,  Status: Open,  Structure Length: 7.45m (24.44ft),  Average Daily Traffic: 2,978 (year 2014),  Truck Traffic: 7%,  Average Future Daily Traffic: 4,497 (year 2034),  Design Load: HS 20+Mod,  Features Intersected: I 70 ML,  Facility Carried by Structure: DEBEQUE CUTOFF RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.248,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 39.2m (128.6ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 71.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: G-04-AF,  Location: 15.6 MI E OF JCT SH 65 (Lat: 39.354728,  Lng: -108.171458),  Route carried "on" structure: Interstate 70A,  Year Built: 1980,  Status: Open,  Structure Length: 6.25m (20.51ft),  Average Daily Traffic: 9,000 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 11,790 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: UP RR,  Facility Carried by Structure: I 70 ML EBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 104.170,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.3m (73.2ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 34.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: G-04-AG,  Location: 9.7 MI W OF PARACHUTE (Lat: 39.354714,  Lng: -108.171864),  Route carried "on" structure: Interstate 70A,  Year Built: 1980,  Status: Open,  Structure Length: 6.35m (20.83ft),  Average Daily Traffic: 9,000 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 11,790 (year 2040),  Design Load: HS 20,  Features Intersected: UP RR,  Facility Carried by Structure: I 70 ML WBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 104.149,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.7m (74.5ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 82.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: G-04-AH,  Location: 3 MI E OF DEBEQUE (Lat: 39.357797,  Lng: -108.170508),  Route carried "on" structure: US 6M,  Year Built: 1980,  Status: Open,  Structure Length: 11.13m (36.52ft),  Average Daily Traffic: 1,200 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,220 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I 70 ML,  Facility Carried by Structure: US 6 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.274,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 40.5m (132.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: G-04-AL,  Location: 2.9 MI W OF DEBEQUE EXIT (Lat: 39.285864,  Lng: -108.228375),  Route carried "on" structure: ServiceInterstate 70A,  Year Built: 1982,  Status: Open,  Structure Length: 7.21m (23.65ft),  Average Daily Traffic: 8,400 (year 2020),  Truck Traffic: 20%,  Average Future Daily Traffic: 10,836 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I 70 ML,  Facility Carried by Structure: I 70 FRONTAGE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.025,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.7m (117.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 55.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: G-04-AM,  Location: 0.7 MI E. OF MESA/GARFIEL (Lat: 39.374706,  Lng: -108.161997),  Route carried "on" structure: Interstate 70A,  Year Built: 1982,  Status: Open,  Structure Length: 3.58m (11.75ft),  Average Daily Traffic: 9,000 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 11,610 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BLM ACCESS ROAD,  Facility Carried by Structure: I 70 ML EBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 106.703,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 35.1m (115.2ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 87.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: G-04-AN,  Location: 8 MI W. OF PARACHUTE (Lat: 39.375394,  Lng: -108.162733),  Route carried "on" structure: Interstate 70A,  Year Built: 1982,  Status: Open,  Structure Length: 3.58m (11.75ft),  Average Daily Traffic: 9,000 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 11,610 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BLM ACCESS ROAD,  Facility Carried by Structure: I 70 ML WBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 106.703,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 35.1m (115.2ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 62.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: G-04-AU,  Location: 10.0 MI E OF JCT SH 65 (Lat: 39.288914,  Lng: -108.225467),  Route carried "on" structure: Interstate 70A,  Year Built: 1980,  Status: Open,  Structure Length: 1.27m (4.17ft),  Average Daily Traffic: 17,000 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 21,760 (year 2040),  Design Load: HS 20,  Features Intersected: SAND WASH,  Facility Carried by Structure: I 70 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 95.151,  Lanes on structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 39.6m (129.9ft),  Skew: 24 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.8m (15.7ft),  Out-to-Out Width: 99.0m (324.8ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: G-04-AV,  Location: 3 MI W. OF DEBEQUE (Lat: 39.293239,  Lng: -108.222836),  Route carried "on" structure: Interstate 70A,  Year Built: 1980,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 17,000 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 21,760 (year 2040),  Design Load: HS 20,  Features Intersected: ASHMEAD DRAW,  Facility Carried by Structure: I 70 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 95.679,  Lanes on structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 39.6m (129.9ft),  Skew: 12 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.2m (10.5ft),  Out-to-Out Width: 92.8m (304.5ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: G-04-AW,  Location: 0.5 mi W. of Debeque Int. (Lat: 39.315642,  Lng: -108.212158),  Route carried "on" structure: Interstate 70A,  Year Built: 1980,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 17,000 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 21,760 (year 2040),  Design Load: HS 20,  Features Intersected: LITTLE HORSE THIEF CRK,  Facility Carried by Structure: I 70 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 98.331,  Lanes on structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 39.9m (130.9ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.0m (13.1ft),  Out-to-Out Width: 92.0m (301.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2018
Find on map >>   Show street view

Structure Number: G-04-AX,  Location: JUST E. OF DEBEQUE INTERC (Lat: 39.331831,  Lng: -108.196244),  Route carried "on" structure: Interstate 70A,  Year Built: 1980,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 18,000 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 23,580 (year 2040),  Design Load: HS 20,  Features Intersected: HORSETHIEF CREEK,  Facility Carried by Structure: I 70 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 100.640,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.9m (16.1ft),  Out-to-Out Width: 57.3m (188.0ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2018
Find on map >>   Show street view

Structure Number: G-04-AY,  Location: JUST E. OF DEBEQUE INTERC (Lat: 39.331222,  Lng: -108.195667),  Route carried "on" structure: ServiceInterstate 70A,  Year Built: 1980,  Status: Open,  Structure Length: 1.43m (4.69ft),  Average Daily Traffic: 18,000 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 23,580 (year 2040),  Design Load: HS 20,  Features Intersected: HORSETHIEF CREEK (S) SR,  Facility Carried by Structure: I70 FRONTAGE RD(S)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.011,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 5.2m (17.1ft),  Out-to-Out Width: 24.6m (80.7ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: G-04-AZ,  Location: JUST E. OF DEBEQUE INTERC (Lat: 39.332336,  Lng: -108.196928),  Route carried "on" structure: ServiceUS 6M,  Year Built: 1980,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 1,200 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,220 (year 2040),  Design Load: HS 20,  Features Intersected: HORSETHIEF CREEK [N] SR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.228,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.9m (16.1ft),  Out-to-Out Width: 24.4m (80.1ft)

Condition: Channel: Poor,  Culverts: Fair,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: G-04-BA,  Location: 9.3 MI E OF JCT SH 65 (Lat: 39.281711,  Lng: -108.236447),  Route carried "on" structure: Interstate 70A,  Year Built: 1981,  Status: Open,  Structure Length: 12.71m (41.70ft),  Average Daily Traffic: 8,500 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 10,880 (year 2040),  Design Load: HS 20,  Features Intersected: COLORADO RIVER,  Facility Carried by Structure: I 70 ML WBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 93.775,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 31.1m (102.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 53.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 13.54m (44.42ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Bridge Improvement Cost: $2,452,000,  Roadway Improvement Cost: $245,000,  Total Project Cost: $3,678,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: G-04-D,  Location: 10.9 MI W. OF PARACHUTE (Lat: 39.341661,  Lng: -108.192711),  Route carried "on" structure: ServiceUS 6M,  Year Built: 1945,  Year Reconstructed: 1957,  Status: Open,  Structure Length: 5.12m (16.80ft),  Average Daily Traffic: 1,200 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,220 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: Colorado N. Channel,  Facility Carried by Structure: US 6 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.326,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: G-04-H,  Location: 0.2 MI. W. OF MESA/GARFIE (Lat: 39.364092,  Lng: -108.169819),  Route carried "on" structure: Interstate 70A,  Year Built: 1951,  Year Reconstructed: 1981,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 18,000 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 23,580 (year 2040),  Design Load: H 20,  Features Intersected: DRAW,  Facility Carried by Structure: I 70 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 105.235,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 13 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.5m (11.5ft),  Out-to-Out Width: 50.7m (166.3ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: H-03-J,  Location: 7.2 MI E OF JCT SH 65 ML (Lat: 39.243439,  Lng: -108.255522),  Route carried "on" structure: Interstate 70A,  Year Built: 1959,  Year Reconstructed: 1987,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 17,000 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 21,760 (year 2040),  Design Load: H 20,  Features Intersected: DRAW,  Facility Carried by Structure: I 70 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 88.836,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Out-to-Out Width: 26.9m (88.3ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: MESA-43.5-U.2A,  Location: 2.5 MI SW ON CR 44 (Lat: 39.307528,  Lng: -108.237222),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 1.12m (3.67ft),  Average Daily Traffic: 24 (year 2018),  Average Future Daily Traffic: 37 (year 2038),  Design Load: HS 20,  Features Intersected: COON HOLLOW WASH,  Facility Carried by Structure: COUNTY ROAD 43.5
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.318,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.5m (18.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 62.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022
Find on map >>   Show street view

Structure Number: MESA-44-V.6A,  Location: .2 MI W OF DENVER AVE. (Lat: 39.330944,  Lng: -108.218111),  Route carried "on" structure: County highway ,  Year Built: 1988,  Status: Open,  Structure Length: 3.13m (10.27ft),  Average Daily Traffic: 289 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 437 (year 2038),  Design Load: HS 20,  Features Intersected: ROAN CREEK,  Facility Carried by Structure: COUNTY ROAD 44
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.577,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.8m (97.8ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 57.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: MESA-45.5-U.24,  Location: 1.6 MILES S OF DEBEQUE (Lat: 39.313083,  Lng: -108.205111),  Route carried "on" structure: County highway ,  Year Built: 2008,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 1,067 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,611 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: NO NAME DITCH,  Facility Carried by Structure: COUNTY ROAD 45.5
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.073,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 50.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: MESA-V.5-45.3A,  Location: .3 MI N OF I-70 (DEBEQUE) (Lat: 39.331583,  Lng: -108.208806),  Route carried "on" structure: City street ,  Year Built: 1962,  Year Reconstructed: 2008,  Status: Open,  Structure Length: 12.74m (41.80ft),  Average Daily Traffic: 1,903 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,873 (year 2038),  Design Load: HS 20,  Features Intersected: COLORADO RIVER,  Facility Carried by Structure: COUNTY ROAD 45
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.016,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 37.0m (121.4ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 51.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: January 2022,  Underwater Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: MESA-X.5-42.9A,  Location: 1 MI N OF DEBEQUE (Lat: 39.365583,  Lng: -108.253028),  Route carried "on" structure: County highway ,  Year Built: 2009,  Status: Open,  Structure Length: 2.32m (7.61ft),  Average Daily Traffic: 130 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 197 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: ROAN CREEK,  Facility Carried by Structure: County Road X.5
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.418,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.9m (71.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 76.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: G-04-AE,  Location: DEBEQUE INTER. (Lat: 39.324364,  Lng: -108.206286),  Route carried "under" structure: Interstate 70A,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 580 (year 2014),  Truck Traffic: 15%,  Features Intersected: I 70 ML,  Facility Carried by Structure: DEBEQUE CUTOFF RD
Minimum Vertical Clearance: 6.20m (20.34ft),  Kilometerpoint: 3.246,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 39.2m (128.6ft)

Find on map >>   Show street view

Structure Number: G-04-AH,  Location: 3 MI E OF DEBEQUE (Lat: 39.357797,  Lng: -108.170508),  Route carried "under" structure: Interstate 70A,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 14,000 (year 2011),  Truck Traffic: 16%,  Features Intersected: I 70 ML,  Facility Carried by Structure: US 6 ML
Minimum Vertical Clearance: 5.67m (18.60ft),  Kilometerpoint: 104.376,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 40.5m (132.9ft)

Find on map >>   Show street view

Structure Number: G-04-AL,  Location: 2.9 MI W OF DEBEQUE EXIT (Lat: 39.285864,  Lng: -108.228375),  Route carried "under" structure: Interstate 70A,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 19,000 (year 2018),  Truck Traffic: 15%,  Features Intersected: I 70 ML,  Facility Carried by Structure: I 70 FRONTAGE RD
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 0.024,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 35.7m (117.1ft)

Find on map >>   Show street view

Structure Number: G-04-AM,  Location: 0.7 MI E. OF MESA/GARFIEL (Lat: 39.374706,  Lng: -108.161997),  Route carried "under" structure: ServiceOther road ,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 1,000 (year 0000),  Features Intersected: BLM ACCESS ROAD,  Facility Carried by Structure: I 70 ML EBND
Minimum Vertical Clearance: 4.67m (15.32ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.1m (115.2ft)

Discuss De Beque, Colorado (CO) on our hugely popular Colorado forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.