Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Edgerton, Kansas (KS)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 41Number of bridges
  • 541ft / 165mTotal length
  • $337,000Total costs
  • 131,016Total average daily traffic
  • 25,482Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Edgerton
  • No street view available for this location

New bridges in Edgerton, KS - historical statistics
  • New bridges - historical statistics
  • 11910-1919
  • 21930-1939
  • 11940-1949
  • 61950-1959
  • 41980-1989
  • 81990-1999
  • 42000-2009
  • 132010-2019
  • 22020-2022
Reconstructed bridges in Edgerton, KS - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11970-1979
  • 31980-1989
Average Bridge Daily Traffic in Edgerton, KS
Average Bridge Truck Traffic in Edgerton, KS
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 32.0%Very good
  • 52.0%Good
  • 16.0%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 44.0%Very good
  • 32.0%Good
  • 20.0%Satisfactory
  • 4.0%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 36.0%Very good
  • 56.0%Good
  • 4.0%Satisfactory
  • 4.0%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 25.8%Very good
  • 41.9%Good
  • 29.0%Satisfactory
  • 3.2%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 16.7%Very good
  • 58.3%Good
  • 25.0%Satisfactory
Find on map >>   Show street view

Structure Number: 46008,  Location: 1.0 E OF EDGERTON (Lat: 38.767658,  Lng: -94.982719),  Route carried "on" structure: County highway 347,  Year Built: 2009,  Status: Open,  Structure Length: 4.95m (16.24ft),  Average Daily Traffic: 1,959 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 2,400 (year 2041),  Design Load: HL 93,  Features Intersected: BIG BULL CREEK,  Facility Carried by Structure: 199TH ST. E.0-2.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.5m (64.0ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 34.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 46019,  Location: E. EDGERTON (Lat: 38.764858,  Lng: -95.003614),  Route carried "on" structure: City street 348,  Year Built: 1986,  Status: Open,  Structure Length: 3.41m (11.19ft),  Average Daily Traffic: 1,251 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,500 (year 2041),  Design Load: HS 20,  Features Intersected: TRIB. TO BIG BULL CREEK,  Facility Carried by Structure: NELSON RD C.9-1.8
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 62.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 46043,  Location: 0.25N OF EDGERTON (Lat: 38.769672,  Lng: -95.019231),  Route carried "on" structure: County highway 348,  Year Built: 1994,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 869 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,050 (year 2041),  Design Load: HS 20,  Features Intersected: MARTIN CREEK,  Facility Carried by Structure: EDGERTON C.0-2.15
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.3m (14.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 91.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 54.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 46044,  Location: 0.3N OF EDGERTON (Lat: 38.771172,  Lng: -95.019206),  Route carried "on" structure: County highway 348,  Year Built: 1994,  Status: Open,  Structure Length: 1.36m (4.46ft),  Average Daily Traffic: 869 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,050 (year 2041),  Design Load: HS 20,  Features Intersected: MARTIN CREEK TRIB.,  Facility Carried by Structure: EDGERTON C.0-2.30
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.2m (13.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 91.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 54.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 6102,  Location: 2.0W 1.7S OF ANTIOCH (Lat: 38.700114,  Lng: -94.982478),  Route carried "on" structure: County highway 348,  Year Built: 1980,  Status: Open,  Structure Length: 6.68m (21.92ft),  Average Daily Traffic: 384 (year 2011),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,571 (year 2041),  Design Load: HS 20,  Features Intersected: ROCK CREEK,  Facility Carried by Structure: Spoon Creek Rd
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 2.609,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 10.9m (35.8ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 66.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: June 2021,  Underwater Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 61021,  Location: 11.2N 6.6W OF PAOLA (Lat: 38.734581,  Lng: -95.000861),  Route carried "on" structure: County highway 348,  Year Built: 1997,  Status: Open,  Structure Length: 0.77m (2.53ft),  Average Daily Traffic: 540 (year 2011),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,700 (year 2041),  Design Load: HS 20,  Features Intersected: BIG BULL CREEK,  Facility Carried by Structure: Sunflower Rd
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 8.098,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.5m (24.6ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 71.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 61052,  Location: 1.0S 1.3W OF ANTIOCH (Lat: 38.711411,  Lng: -94.968858),  Route carried "on" structure: County highway 1030,  Year Built: 1980,  Status: Open,  Structure Length: 7.59m (24.90ft),  Average Daily Traffic: 220 (year 2011),  Truck Traffic: 10%,  Average Future Daily Traffic: 783 (year 2041),  Design Load: HS 20,  Features Intersected: BIG BULL CREEK,  Facility Carried by Structure: 231st Street
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 1.191,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 10.9m (35.8ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 56.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: June 2021,  Underwater Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 610522,  Location: 2.0S 6.5W OF SPRING HILL (Lat: 38.709356,  Lng: -94.936583),  Route carried "on" structure: County highway 1030,  Year Built: 1980,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 193 (year 2011),  Truck Traffic: 10%,  Average Future Daily Traffic: 713 (year 2041),  Features Intersected: SMITH BR. OF BULL CREEK,  Facility Carried by Structure: 231st Street
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 4.041,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 46106750468,  Location: .48 mi. W of Edgerton Rd. (Lat: 38.782222,  Lng: -95.028081),  Route carried "on" structure: County highway ,  Year Built: 2009,  Status: Open,  Structure Length: 0.75m (2.46ft),  Average Daily Traffic: 41 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 50 (year 2041),  Design Load: HS 20,  Features Intersected: Martin Creek Trib,  Facility Carried by Structure: 191st St. B.52-3.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.9m (12.8ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 84.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 50.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 461069004725,  Location: .5 mi. N of 215th St. (Lat: 38.746214,  Lng: -95.019119),  Route carried "on" structure: County highway ,  Year Built: 2010,  Status: Open,  Structure Length: 2.27m (7.45ft),  Average Daily Traffic: 39 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 50 (year 2041),  Design Load: HS 20,  Features Intersected: Martin Creek Trib,  Facility Carried by Structure: Edgerton C.0-0.53
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 5.7m (18.7ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 65.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 46106940472,  Location: 2.4E OF DOUGLAS CO. LINE (Lat: 38.753128,  Lng: -95.012811),  Route carried "on" structure: County highway ,  Year Built: 1999,  Status: Open,  Structure Length: 2.62m (8.60ft),  Average Daily Traffic: 988 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,200 (year 2041),  Design Load: HS 20,  Features Intersected: TRIB TO MARTIN CREEK,  Facility Carried by Structure: 207TH ST. C.4-1.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.3m (83.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 42.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 46107140466,  Location: 2mi N, .4mi E of Edgerton (Lat: 38.796758,  Lng: -94.994347),  Route carried "on" structure: County highway ,  Year Built: 2011,  Status: Open,  Structure Length: 1.12m (3.67ft),  Average Daily Traffic: 77 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 100 (year 2041),  Design Load: HS 20,  Features Intersected: Bull Creek Tributary,  Facility Carried by Structure: 183rd St. D.4-4.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.5m (18.0ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 62.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 46107190468,  Location: 3.1W OF I-35 (Lat: 38.782158,  Lng: -94.984481),  Route carried "on" structure: County highway ,  Year Built: 1990,  Status: Open,  Structure Length: 1.11m (3.64ft),  Average Daily Traffic: 71 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 100 (year 2041),  Design Load: HS 20,  Features Intersected: BIG BULL CREEK,  Facility Carried by Structure: 191ST ST. D.9-3.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.1m (33.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 94.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 56.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 46107310466,  Location: 2.0N 1.1E OF EDGERTON (Lat: 38.796758,  Lng: -94.981922),  Route carried "on" structure: County highway ,  Year Built: 1940,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 77 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 100 (year 2041),  Features Intersected: BIG BULL CREEK,  Facility Carried by Structure: 183RD ST. E.1-4.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.8m (22.3ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.4m (21.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 6.9m (22.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 51.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 46107680468,  Location: 0.1 MI WEST OF WAVERLY RD (Lat: 38.782122,  Lng: -94.948078),  Route carried "on" structure: City street 22131,  Year Built: 2012,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 2,500 (year 2017),  Truck Traffic: 25%,  Average Future Daily Traffic: 3,000 (year 2041),  Design Load: HS 20,  Features Intersected: TRIB TO BULL CREEK,  Facility Carried by Structure: 191ST ST. F.87-3.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.8m (38.7ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.9m (16.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 90.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 68.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 461077004702,  Location: 0.2S 3.0E OF EDGERTON (Lat: 38.764728,  Lng: -94.945878),  Route carried "on" structure: County highway ,  Year Built: 1990,  Status: Open,  Structure Length: 3.12m (10.24ft),  Average Daily Traffic: 118 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 150 (year 2041),  Design Load: HS 20,  Features Intersected: BIG BULL CREEK TRIB.,  Facility Carried by Structure: WAVERLY G.0-1.8
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 64.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 6110712048,  Location: 6.9W 8.0N OF PAOLA (Lat: 38.694897,  Lng: -95.001003),  Route carried "on" structure: County highway ,  Year Built: 1915,  Status: Posted for load,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 48 (year 2011),  Average Future Daily Traffic: 45 (year 2041),  Features Intersected: TRIB. TO ROCK CREEK,  Facility Carried by Structure: 239th Street
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 5.2m (17.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.8m (25.6ft),  Curb-To-Curb Width: 4.7m (15.4ft),  Out-to-Out Width: 4.9m (16.1ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 9.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 5.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of replacement,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: High priority of corrective action,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 1.22m (4.00ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $200,000,  Roadway Improvement Cost: $95,000,  Total Project Cost: $300,000,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 611073004743,  Location: 9.0W 0.2S of Spring Hill (Lat: 38.735711,  Lng: -94.982778),  Route carried "on" structure: County highway ,  Year Built: 2013,  Status: Open,  Structure Length: 1.19m (3.90ft),  Average Daily Traffic: 72 (year 2011),  Truck Traffic: 2%,  Average Future Daily Traffic: 643 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: Trib. to Big Bull Creek,  Facility Carried by Structure: Spoon Crk Road
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.2m (23.6ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.9m (12.8ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 14.1m (46.3ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 38.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 6110731048,  Location: 2.4W 2.0S OF ANTIOCH (Lat: 38.694803,  Lng: -94.991225),  Route carried "on" structure: County highway ,  Year Built: 1930,  Year Reconstructed: 1983,  Status: Open,  Structure Length: 0.84m (2.76ft),  Average Daily Traffic: 142 (year 2011),  Average Future Daily Traffic: 283 (year 2041),  Design Load: HS 20,  Features Intersected: TRIB. TO ROCK CREEK,  Facility Carried by Structure: 239th Street
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.5m (11.5ft),  Curb-To-Curb Width: 5.3m (17.4ft),  Out-to-Out Width: 5.5m (18.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Fair,  Operating Rating: 90.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 55.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 0.79m (2.59ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $24,000,  Roadway Improvement Cost: $2,000,  Total Project Cost: $37,000,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 611075304743,  Location: 1.2N 0.8W OF ANTIOCH (Lat: 38.735292,  Lng: -94.959142),  Route carried "on" structure: County highway 738,  Year Built: 2019,  Status: Open,  Structure Length: 1.26m (4.13ft),  Average Daily Traffic: 20 (year 2012),  Average Future Daily Traffic: 63 (year 2041),  Design Load: HL 93,  Features Intersected: TRIB. TO BIG BULL CREEK,  Facility Carried by Structure: 217th Street
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 48.3 metric tons,  Method Used To Determine Operating Rating: No rating analysis performed,  Inventory Rating: 20.3 metric tons,  Method Used To Determine Inventory Rating: No rating analysis performed,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 507500460000001,  Location: 0.5N 2.0E OF EDGERTON (Lat: 38.774919,  Lng: -94.963750),  Route carried "on" structure: City street 22543,  Year Built: 2011,  Status: Open,  Structure Length: 9.22m (30.25ft),  Average Daily Traffic: 3,600 (year 2013),  Truck Traffic: 24%,  Average Future Daily Traffic: 14,700 (year 2041),  Design Load: HL 93,  Features Intersected: TRIB. TO BULL CREEK,  Facility Carried by Structure: HOMESTEAD LN (SB)
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 42.7m (140.1ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 3.7m (12.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 52.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 40.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 507500460000002,  Location: 0.5N 2.0E OF EDGERTON (Lat: 38.774969,  Lng: -94.963561),  Route carried "on" structure: City street 22542,  Year Built: 2011,  Status: Open,  Structure Length: 9.22m (30.25ft),  Average Daily Traffic: 3,600 (year 2013),  Truck Traffic: 24%,  Average Future Daily Traffic: 14,700 (year 2041),  Design Load: HL 93,  Features Intersected: TRIB. TO BULL CREEK,  Facility Carried by Structure: HOMESTEAD LN (NB)
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 42.7m (140.1ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 59.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 45.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 507500460000003,  Location: 1.2 MI S JCT US-56 (Lat: 38.784719,  Lng: -94.945831),  Route carried "on" structure: City street 21984,  Year Built: 2015,  Status: Open,  Structure Length: 1.87m (6.14ft),  Average Daily Traffic: 2,400 (year 2015),  Truck Traffic: 14%,  Average Future Daily Traffic: 10,400 (year 2041),  Design Load: HL 93,  Features Intersected: BIG BULL TRIBUTARY E,  Facility Carried by Structure: WAVERLY RD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.4m (40.7ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 5.6m (18.4ft)

Condition: Channel: Very good,  Culverts: Very good,  Inventory Rating: 10.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 507500460000004,  Location: 0.6 MI S JCT US-56 (Lat: 38.798331,  Lng: -94.945831),  Route carried "on" structure: City street 21858,  Year Built: 2016,  Status: Open,  Structure Length: 22.06m (72.38ft),  Average Daily Traffic: 400 (year 2016),  Truck Traffic: 10%,  Average Future Daily Traffic: 4,500 (year 2041),  Design Load: HL 93,  Features Intersected: BNSF RR & BULL CRK TRIB,  Facility Carried by Structure: WAVERLY RD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.4m (40.7ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 43.1m (141.4ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 0.0m,  Curb-To-Curb Width: 12.5m (41.0ft),  Out-to-Out Width: 16.6m (54.5ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 69.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 40.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 999903300231041,  Location: .8 MI S U-56/K-33 JCT (Lat: 38.755278,  Lng: -95.074722),  Route carried "on" structure: State highway 33,  Year Built: 2004,  Status: Open,  Structure Length: 0.63m (2.07ft),  Average Daily Traffic: 1,430 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 1,852 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: WALNUT CREEK DRAINAGE
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 1.865,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 56.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 2.07m (6.79ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 999903500460021,  Location: 2.07 MI NE MI COLN, SB (Lat: 38.750833,  Lng: -94.982778),  Route carried "on" structure: Interstate 35,  Year Built: 1959,  Status: Open,  Structure Length: 3.88m (12.73ft),  Average Daily Traffic: 11,098 (year 2020),  Truck Traffic: 25%,  Average Future Daily Traffic: 18,544 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: SPOON CREEK RD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 3.335,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 60.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 12.72m (41.73ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 999903500460031,  Location: 2.06 MI NE MI COLN, NB (Lat: 38.750556,  Lng: -94.982778),  Route carried "on" structure: Interstate 35,  Year Built: 1959,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 3.88m (12.73ft),  Average Daily Traffic: 11,098 (year 2020),  Truck Traffic: 25%,  Average Future Daily Traffic: 18,544 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: SPOON CREEK RD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 3.286,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 60.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 12.72m (41.73ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 999903500460041,  Location: 2.46 MI NE MI COLN, WL (Lat: 38.753333,  Lng: -94.976389),  Route carried "on" structure: Interstate 35,  Year Built: 1959,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 10.15m (33.30ft),  Average Daily Traffic: 11,098 (year 2020),  Truck Traffic: 25%,  Average Future Daily Traffic: 18,544 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: BULL CREEK
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 3.957,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 12.5m (41.0ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 66.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 33.30m (109.25ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 999903500460051,  Location: 2.45 MI NE MI COLN, EL (Lat: 38.753056,  Lng: -94.976111),  Route carried "on" structure: Interstate 35,  Year Built: 1959,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 9.85m (32.32ft),  Average Daily Traffic: 11,098 (year 2020),  Truck Traffic: 25%,  Average Future Daily Traffic: 18,544 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: BULL CREEK
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 3.924,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 12.5m (41.0ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 72.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 32.30m (105.97ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 999903500464161,  Location: 3.22 MI NE MI COLN (Lat: 38.759167,  Lng: -94.964167),  Route carried "on" structure: City street 2001,  Year Built: 2012,  Status: Open,  Structure Length: 12.65m (41.50ft),  Average Daily Traffic: 43 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 19,132 (year 2041),  Design Load: HL 93,  Features Intersected: I35 HWY,  Facility Carried by Structure: NB HOMESTEAD LN
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.795,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 38.1m (125.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 59.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 41.51m (136.19ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 999903500464171,  Location: 3.23 MI NE MI COLN (Lat: 38.759167,  Lng: -94.963889),  Route carried "on" structure: City street 2001,  Year Built: 2012,  Status: Open,  Structure Length: 12.65m (41.50ft),  Average Daily Traffic: 43 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 28,906 (year 2041),  Design Load: HL 93,  Features Intersected: I35 HWY,  Facility Carried by Structure: SB HOMESTEAD LN
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.811,  Lanes on structure: 3,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 16.2m (53.1ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 38.1m (125.0ft),  Curb-To-Curb Width: 16.2m (53.1ft),  Out-to-Out Width: 16.9m (55.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 47.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 41.51m (136.19ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 999903500464231,  Location: 1.03 MI NE MI COLN (Lat: 38.746389,  Lng: -95.000833),  Route carried "on" structure: County highway 348,  Year Built: 2020,  Status: Open,  Structure Length: 7.32m (24.02ft),  Average Daily Traffic: 1,862 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 19,132 (year 2041),  Design Load: HL 93,  Features Intersected: I35 HWY WL-EL,  Facility Carried by Structure: SUNFLOWER ROAD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.882,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.1m (118.4ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 18.5m (60.7ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 57.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 24.02m (78.81ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 999903500610041,  Location: 2.65 MI E FRANKLIN COLN (Lat: 38.736667,  Lng: -95.019444),  Route carried "on" structure: ServiceCounty highway 350,  Year Built: 1958,  Status: Open,  Structure Length: 8.44m (27.69ft),  Average Daily Traffic: 76 (year 2020),  Average Future Daily Traffic: 18,676 (year 2041),  Design Load: HS 20,  Features Intersected: I35 HWY,  Facility Carried by Structure: LOCAL ROAD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.208,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.1m (79.1ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 27.70m (90.88ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 999905600460801,  Location: 0.92 MI E DOUGLAS CO LINE (Lat: 38.767500,  Lng: -95.039167),  Route carried "on" structure: US 56,  Year Built: 1932,  Status: Open,  Structure Length: 0.63m (2.07ft),  Average Daily Traffic: 5,035 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 7,482 (year 2041),  Design Load: H 15,  Features Intersected: MARTIN CREEK
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 1.484,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 31.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 2.08m (6.82ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 999905600462961,  Location: 2.76 MI E DOUGLAS COLN (Lat: 38.767778,  Lng: -95.005278),  Route carried "on" structure: US 56,  Year Built: 1994,  Status: Open,  Structure Length: 3.43m (11.25ft),  Average Daily Traffic: 4,040 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,003 (year 2041),  Design Load: HS 20,  Features Intersected: MARTIN CREEK
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 4.439,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 75.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: High priority of replacement,  Length Of Structure Improvement: 11.25m (36.91ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 999905600462971,  Location: 4.24 MI E DOUGLAS COLN (Lat: 38.780833,  Lng: -94.983611),  Route carried "on" structure: US 56,  Year Built: 1994,  Status: Open,  Structure Length: 3.43m (11.25ft),  Average Daily Traffic: 4,040 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,003 (year 2041),  Design Load: HS 20,  Features Intersected: BULL CREEK
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 6.817,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 75.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 11.25m (36.91ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 999905600463331,  Location: 1.74 MI E DOUGLAS CO LINE (Lat: 38.767500,  Lng: -95.023889),  Route carried "on" structure: US 56,  Year Built: 2007,  Status: Open,  Structure Length: 1.94m (6.36ft),  Average Daily Traffic: 5,035 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 7,482 (year 2041),  Design Load: HL 93,  Features Intersected: MARTIN CREEK
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 2.805,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 77.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 59.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 6.36m (20.87ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 999903500464161,  Location: 3.22 MI NE MI COLN (Lat: 38.759167,  Lng: -94.964167),  Route carried "under" structure: Interstate 35,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 11,098 (year 2020),  Truck Traffic: 25%,  Features Intersected: I35 HWY,  Facility Carried by Structure: NB HOMESTEAD LN
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 5.203,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.1m (125.0ft)

Find on map >>   Show street view

Structure Number: 999903500464171,  Location: 3.23 MI NE MI COLN (Lat: 38.759167,  Lng: -94.963889),  Route carried "under" structure: Interstate 35,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 11,098 (year 2020),  Truck Traffic: 25%,  Features Intersected: I35 HWY,  Facility Carried by Structure: SB HOMESTEAD LN
Minimum Vertical Clearance: 5.39m (17.68ft),  Kilometerpoint: 5.242,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.1m (125.0ft)

Find on map >>   Show street view

Structure Number: 999903500464231,  Location: 1.03 MI NE MI COLN (Lat: 38.746389,  Lng: -95.000833),  Route carried "under" structure: Interstate 35,  Year Built: 2020,  Structure Length: 0. m,  Average Daily Traffic: 11,173 (year 2020),  Truck Traffic: 20%,  Features Intersected: I35 HWY WL-EL,  Facility Carried by Structure: SUNFLOWER ROAD
Minimum Vertical Clearance: 5.39m (17.68ft),  Kilometerpoint: 1.690,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.1m (118.4ft)

Find on map >>   Show street view

Structure Number: 999903500610041,  Location: 2.65 MI E FRANKLIN COLN (Lat: 38.736667,  Lng: -95.019444),  Route carried "under" structure: Interstate 35,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 11,173 (year 2020),  Truck Traffic: 20%,  Features Intersected: I35 HWY,  Facility Carried by Structure: LOCAL ROAD
Minimum Vertical Clearance: 4.99m (16.37ft),  Kilometerpoint: 4.258,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 24.1m (79.1ft)

Discuss Edgerton, Kansas (KS) on our hugely popular Kansas forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.