  • National Bridge Inventory (NBI) Statistics
  • 18Number of bridges
  • 148ft / 45.2mTotal length
  • 151,600Total average daily traffic
  • 32,493Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Elrod
  • No street view available for this location

New bridges in Elrod, NC - historical statistics
  • New bridges - historical statistics
  • 11960-1969
  • 31970-1979
  • 102000-2009
  • 32010-2019
  • 12020-2022
Average Bridge Daily Traffic in Elrod, NC
Average Bridge Truck Traffic in Elrod, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 22.2%Excellent
  • 11.1%Very good
  • 55.6%Good
  • 11.1%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 22.2%Excellent
  • 55.6%Very good
  • 22.2%Good
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 11.1%Excellent
  • 66.7%Very good
  • 11.1%Good
  • 11.1%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 28.6%Very good
  • 42.9%Good
  • 14.3%Satisfactory
  • 14.3%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 66.7%Good
  • 33.3%Satisfactory
Find on map >>   Show street view

Structure Number: 1550017,  Location: 0.5 MI.N.JCT.SR1154 (Lat: 34.644119,  Lng: -79.245522),  Route carried "on" structure: State highway 710,  Year Built: 2002,  Status: Open,  Structure Length: 2.65m (8.69ft),  Average Daily Traffic: 4,100 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 8,200 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BACK SWAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 17.9m (58.7ft),  Curb-To-Curb Width: 12.5m (41.0ft),  Out-to-Out Width: 13.7m (44.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 74.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1550096,  Location: 0.6 MI.E.JCT.SR2519 (Lat: 34.542228,  Lng: -79.226556),  Route carried "on" structure: State highway 1155,  Year Built: 1973,  Status: Open,  Structure Length: 7.89m (25.89ft),  Average Daily Traffic: 270 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 540 (year 2040),  Design Load: HS 15,  Features Intersected: I95
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 5.7m (18.7ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Number Of Approach Spans: 2,  Length of Maximum Span: 28.6m (93.8ft),  Curb-To-Curb Width: 9.5m (31.2ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 1550098,  Location: 0.5 MI. S. OF JCT. SR2455 (Lat: 34.548686,  Lng: -79.207108),  Route carried "on" structure: Interstate 95,  Year Built: 1960,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 39,000 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 78,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: AARON SWAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.042,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 95),  Owner: State Highway Agency,  Approaching Roadway Width: 18.8m (61.7ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: November 2020,  Underwater Inspection Date: November 2020
Find on map >>   Show street view

Structure Number: 1550135,  Location: 0.5 MI. W. JCT. SR2455 (Lat: 34.555250,  Lng: -79.207150),  Route carried "on" structure: State highway 2519,  Year Built: 2019,  Status: Open,  Structure Length: 2.89m (9.48ft),  Average Daily Traffic: 1,050 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 2,100 (year 2040),  Design Load: HL 93,  Features Intersected: AARON SWAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Very good,  Channel: Very good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: August 2021,  Underwater Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1550143,  Location: 0.1 MI.E.JCT.SR1148 (Lat: 34.586969,  Lng: -79.245672),  Route carried "on" structure: State highway 1146,  Year Built: 2012,  Status: Open,  Structure Length: 1.88m (6.17ft),  Average Daily Traffic: 530 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,060 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: ASHPOLE SWAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.6m (57.7ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 86.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1550432,  Location: 0.5 MI. N. JCT. SR1154 (Lat: 34.624975,  Lng: -79.214472),  Route carried "on" structure: State highway 1157,  Year Built: 2020,  Status: Open,  Structure Length: 2.65m (8.69ft),  Average Daily Traffic: 100 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 200 (year 2040),  Design Load: HL 93,  Features Intersected: BACK SWAMP CANAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 16.4m (53.8ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Very good,  Operating Rating: 49.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1550478,  Location: 2.8 MI.E. JCT. SR1166 (Lat: 34.650586,  Lng: -79.244489),  Route carried "on" structure: Interstate 74,  Year Built: 2009,  Status: Open,  Structure Length: 5.97m (19.59ft),  Average Daily Traffic: 8,000 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 16,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NC710
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.899,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 74),  Owner: State Highway Agency,  Approaching Roadway Width: 14.3m (46.9ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 56.6m (185.7ft),  Curb-To-Curb Width: 14.3m (46.9ft),  Out-to-Out Width: 15.3m (50.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 68.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1550479,  Location: 2.8 MI. E. JCT. SR1166 (Lat: 34.650175,  Lng: -79.244553),  Route carried "on" structure: Interstate 74,  Year Built: 2009,  Status: Open,  Structure Length: 5.94m (19.49ft),  Average Daily Traffic: 8,000 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 16,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NC710
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.899,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 9,  Subroute: 74),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 14 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 56.6m (185.7ft),  Curb-To-Curb Width: 14.3m (46.9ft),  Out-to-Out Width: 15.3m (50.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1550481,  Location: 1.5 MI. E. JCT. NC710 (Lat: 34.632761,  Lng: -79.228114),  Route carried "on" structure: Interstate 74,  Year Built: 2010,  Status: Open,  Structure Length: 5.09m (16.70ft),  Average Daily Traffic: 8,000 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 16,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CSX RAILROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 61.387,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 74),  Owner: State Highway Agency,  Approaching Roadway Width: 12.4m (40.7ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 49.0m (160.8ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1550482,  Location: 0.3 MI. N. JCT.SR1154 (Lat: 34.604264,  Lng: -79.200256),  Route carried "on" structure: State highway 1155,  Year Built: 2008,  Status: Open,  Structure Length: 7.77m (25.49ft),  Average Daily Traffic: 1,800 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 3,600 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I74, US74
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 16.1m (52.8ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 38.1m (125.0ft),  Curb-To-Curb Width: 15.5m (50.9ft),  Out-to-Out Width: 16.5m (54.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 78.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1550507,  Location: 160 FT. W. JCT. NC710 (Lat: 34.653053,  Lng: -79.245122),  Route carried "on" structure: Ramp Interstate 74,  Year Built: 2009,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 2,550 (year 2017),  Truck Traffic: 23%,  Average Future Daily Traffic: 5,100 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: DOUBLE BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 74),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.3m (10.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 86.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: 1550509,  Location: 0.3 MI.E.JCT.NC710 (Lat: 34.645281,  Lng: -79.239933),  Route carried "on" structure: Interstate 74,  Year Built: 2009,  Status: Open,  Structure Length: 1.09m (3.58ft),  Average Daily Traffic: 16,000 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 32,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BACK SWAMP CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 61.021,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 74),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.3m (10.8ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 87.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 67.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: 1550096,  Location: 0.6 MI.E.JCT.SR2519 (Lat: 34.542228,  Lng: -79.226556),  Route carried "under" structure: Interstate 95,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 19,500 (year 2019),  Truck Traffic: 23%,  Features Intersected: SR1155
Minimum Vertical Clearance: 5.20m (17.06ft),  Kilometerpoint: 1.676,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.6m (93.8ft)

Find on map >>   Show street view

Structure Number: 1550096,  Location: 0.6 MI.E.JCT.SR2519 (Lat: 34.542228,  Lng: -79.226556),  Route carried "under" structure: Interstate 95,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 19,500 (year 2019),  Truck Traffic: 23%,  Features Intersected: SR1155
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 1.676,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.6m (93.8ft)

Find on map >>   Show street view

Structure Number: 1550478,  Location: 2.8 MI.E. JCT. SR1166 (Lat: 34.650586,  Lng: -79.244489),  Route carried "under" structure: State highway 710,  Year Built: 2009,  Structure Length: 0. m,  Average Daily Traffic: 4,100 (year 2018),  Truck Traffic: 8%,  Features Intersected: I74 WBL
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 56.6m (185.7ft)

Find on map >>   Show street view

Structure Number: 1550479,  Location: 2.8 MI. E. JCT. SR1166 (Lat: 34.650175,  Lng: -79.244553),  Route carried "under" structure: State highway 710,  Year Built: 2009,  Structure Length: 0. m,  Average Daily Traffic: 3,100 (year 2015),  Truck Traffic: 8%,  Features Intersected: I74,US74
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 56.6m (185.7ft)

Find on map >>   Show street view

Structure Number: 1550482,  Location: 0.3 MI. N. JCT.SR1154 (Lat: 34.604264,  Lng: -79.200256),  Route carried "under" structure: Interstate 74,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 8,000 (year 2019),  Truck Traffic: 23%,  Features Intersected: SR1155
Minimum Vertical Clearance: 5.68m (18.64ft),  Kilometerpoint: 62.149,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.1m (125.0ft)

Find on map >>   Show street view

Structure Number: 1550482,  Location: 0.3 MI. N. JCT.SR1154 (Lat: 34.604264,  Lng: -79.200256),  Route carried "under" structure: Interstate 74,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 8,000 (year 2019),  Truck Traffic: 23%,  Features Intersected: SR1155
Minimum Vertical Clearance: 5.71m (18.73ft),  Kilometerpoint: 62.149,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.1m (125.0ft)