Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Fouke, Arkansas (AR)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 34Number of bridges
  • 279ft / 84.7mTotal length
  • 160,342Total average daily traffic
  • 27,827Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Fouke
  • No street view available for this location

New bridges in Fouke, AR - historical statistics
  • New bridges - historical statistics
  • 21920-1929
  • 11970-1979
  • 11980-1989
  • 182000-2009
  • 12010-2019
  • 12020-2022
Reconstructed bridges in Fouke, AR - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 11960-1969
Average Bridge Daily Traffic in Fouke, AR
Average Bridge Truck Traffic in Fouke, AR
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 30.8%Very good
  • 61.5%Good
  • 7.7%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 84.6%Very good
  • 15.4%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 92.3%Very good
  • 7.7%Good
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 25.0%Very good
  • 56.3%Good
  • 18.8%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 27.3%Very good
  • 72.7%Good
Find on map >>   Show street view

Structure Number: 5209,  Location: .20 MI N JCT WITH SH 134 (Lat: 33.231239,  Lng: -93.887075),  Route carried "on" structure: US 71,  Year Built: 1970,  Status: Open,  Structure Length: 3.02m (9.91ft),  Average Daily Traffic: 1,396 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 2,386 (year 2028),  Design Load: HS 20,  Features Intersected: BOGGY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.462,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.1m (33.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 47.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 6784,  Location: 0.5 MI. N. OF FOUKE (Lat: 33.269422,  Lng: -93.897706),  Route carried "on" structure: County highway 20846,  Year Built: 2003,  Status: Open,  Structure Length: 10.85m (35.60ft),  Average Daily Traffic: 1,900 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 126 (year 2023),  Design Load: HS 20,  Features Intersected: I 49 N.B & S.B-18.34,  Facility Carried by Structure: N. FOUKE RD.-0.40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.644,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 32.0m (105.0ft),  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 11.7m (38.4ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6785,  Location: 2.5 MI. NORTH OF FOUKE (Lat: 33.291114,  Lng: -93.919117),  Route carried "on" structure: County highway 26,  Year Built: 2003,  Status: Open,  Structure Length: 13.59m (44.59ft),  Average Daily Traffic: 1,453 (year 1987),  Truck Traffic: 1%,  Average Future Daily Traffic: 327 (year 2007),  Design Load: HS 20,  Features Intersected: I 49 N.&S.BND.20.31
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.046,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 39.9m (130.9ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 20807,  Location: 3 MI N OF FOUKE (Lat: 33.311381,  Lng: -93.865269),  Route carried "on" structure: County highway 10,  Year Built: 1989,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 2,631 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 201 (year 2009),  Features Intersected: BRANCH OF BEECH CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.595,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 35.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 22915,  Location: 2.5 MI. N.W OF FOUKE (Lat: 33.291078,  Lng: -93.923819),  Route carried "on" structure: County highway 26,  Year Built: 2005,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 1,453 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 471 (year 2024),  Design Load: H 20,  Features Intersected: MILL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.497,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: 24092,  Location: 1 M S JCT CO RD 43 (Lat: 33.269689,  Lng: -93.912289),  Route carried "on" structure: County highway 41,  Year Built: 2019,  Status: Posted for load-capacity,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 187 (year 2018),  Truck Traffic: 1%,  Features Intersected: CHICKEN CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.977,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.8m (19.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 24122,  Location: 1.5 M W JCT US 71 (Lat: 33.283528,  Lng: -93.922200),  Route carried "on" structure: County highway 43,  Year Built: 2020,  Status: Open,  Structure Length: 1.53m (5.02ft),  Average Daily Traffic: 176 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 398 (year 2002),  Features Intersected: Mill Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.258,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.1m (46.3ft),  Curb-To-Curb Width: 7.1m (23.3ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: A6736,  Location: 2.5 MI. SO. OF FOUKE (Lat: 33.224617,  Lng: -93.873603),  Route carried "on" structure: Interstate 49,  Year Built: 2004,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 3,000 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 2,575 (year 2028),  Design Load: HS 20,  Features Intersected: S.H. 134- 01 - 0.80
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.545,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 490,  Subroute: 49),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.2m (53.1ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: A6737,  Location: 1.5 MI. SO. OF FOUKE (Lat: 33.240147,  Lng: -93.873608),  Route carried "on" structure: Interstate 49,  Year Built: 2004,  Status: Open,  Structure Length: 5.61m (18.41ft),  Average Daily Traffic: 18,000 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 2,575 (year 2028),  Design Load: HS 20,  Features Intersected: BOGGY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 25.299,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 490,  Subroute: 49),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: A6783,  Location: 0.5 MI. WEST OF FOUKE (Lat: 33.258150,  Lng: -93.895939),  Route carried "on" structure: Interstate 49,  Year Built: 2003,  Status: Open,  Structure Length: 4.18m (13.71ft),  Average Daily Traffic: 3,200 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 3,140 (year 2028),  Design Load: HS 20,  Features Intersected: CO. RD. 7 - E- 0.10
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.260,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.1m (56.1ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: A6832,  Location: 0.5 MI. SO. OF FOUKE (Lat: 33.249400,  Lng: -93.886131),  Route carried "on" structure: Interstate 49,  Year Built: 2004,  Status: Open,  Structure Length: 7.68m (25.20ft),  Average Daily Traffic: 13,494 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 2,575 (year 2028),  Design Load: HS 20+Mod,  Features Intersected: U.S.71- 01- 16.45
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 26.924,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 34.1m (111.9ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B6736,  Location: 2.5 MI. SO. OF FOUKE (Lat: 33.224608,  Lng: -93.873261),  Route carried "on" structure: Interstate 49,  Year Built: 2004,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 3,000 (year 2018),  Truck Traffic: 34%,  Average Future Daily Traffic: 7,800 (year 2038),  Design Load: HS 20,  Features Intersected: S.H. 134
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.545,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 490,  Subroute: 49),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.2m (53.1ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B6737,  Location: 1.5 MI. SO. OF FOUKE (Lat: 33.240389,  Lng: -93.873328),  Route carried "on" structure: Interstate 49,  Year Built: 2004,  Status: Open,  Structure Length: 5.61m (18.41ft),  Average Daily Traffic: 18,000 (year 2018),  Truck Traffic: 34%,  Average Future Daily Traffic: 2,575 (year 2028),  Design Load: HS 20,  Features Intersected: BOGGY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 25.299,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 490,  Subroute: 49),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B6783,  Location: 0.5 MI W OF FOUKE (Lat: 33.258281,  Lng: -93.895639),  Route carried "on" structure: Interstate 49,  Year Built: 2003,  Status: Open,  Structure Length: 4.18m (13.71ft),  Average Daily Traffic: 3,200 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 3,140 (year 2028),  Design Load: HS 20,  Features Intersected: CO. RD. 7 ZONE -E
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.260,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.1m (56.1ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B6832,  Location: 0.5 MI. SO. OF FOUKE. (Lat: 33.249731,  Lng: -93.886111),  Route carried "on" structure: Interstate 49,  Year Built: 2004,  Status: Open,  Structure Length: 7.68m (25.20ft),  Average Daily Traffic: 13,494 (year 2018),  Truck Traffic: 34%,  Average Future Daily Traffic: 2,575 (year 2028),  Design Load: HS 20+Mod,  Features Intersected: U.S 71-SEC.01-16.47
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 26.924,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 490,  Subroute: 49),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 34.1m (111.9ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: M1341,  Location: 1.0 MI N FOUKE ARK. (Lat: 33.273078,  Lng: -93.892547),  Route carried "on" structure: US 71,  Year Built: 1928,  Year Reconstructed: 1971,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 2,200 (year 2018),  Truck Traffic: 4%,  Average Future Daily Traffic: 3,014 (year 2028),  Features Intersected: CHICKEN CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.513,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 710,  Subroute: 71),  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 29.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: M1342,  Location: 4.0 MI N FOUKE , ARK. (Lat: 33.305058,  Lng: -93.924389),  Route carried "on" structure: US 71,  Year Built: 1928,  Year Reconstructed: 1961,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 2,200 (year 2018),  Truck Traffic: 4%,  Average Future Daily Traffic: 3,014 (year 2028),  Features Intersected: MILL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.132,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 710,  Subroute: 71),  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 35.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: X1124,  Location: .15 MI.N.JCT. CR 7& I 49 (Lat: 33.260203,  Lng: -93.896911),  Route carried "on" structure: Interstate 49,  Year Built: 2002,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 6,400 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 6,279 (year 2028),  Design Load: HS 20,  Features Intersected: DRAINAGE DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.534,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: X1125,  Location: .35 MI. N. OF N.FOUKE RD. (Lat: 33.273397,  Lng: -93.901567),  Route carried "on" structure: Interstate 49,  Year Built: 2002,  Status: Open,  Structure Length: 1.19m (3.90ft),  Average Daily Traffic: 9,200 (year 2018),  Truck Traffic: 33%,  Average Future Daily Traffic: 12,000 (year 2038),  Design Load: H 20,  Features Intersected: CHICKEN CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 30.095,  Lanes on structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: X1126,  Location: 0.82 MI. N.OF N. FOUKE RD (Lat: 33.274100,  Lng: -93.902050),  Route carried "on" structure: Interstate 49,  Year Built: 2002,  Status: Open,  Structure Length: 1.19m (3.90ft),  Average Daily Traffic: 9,200 (year 2018),  Truck Traffic: 33%,  Average Future Daily Traffic: 12,000 (year 2038),  Design Load: H 20,  Features Intersected: BRANCH OF CHICKEN CRK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 30.191,  Lanes on structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 30.5m (100.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: X1127,  Location: 2.18 MI.SO.JCT.26N& I 49 (Lat: 33.292606,  Lng: -93.921403),  Route carried "on" structure: Interstate 49,  Year Built: 2002,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 9,200 (year 2018),  Truck Traffic: 33%,  Average Future Daily Traffic: 12,000 (year 2038),  Design Load: H 20,  Features Intersected: MILL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.943,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 42.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: X1128,  Location: 2.16 M.S.Jct.CR.26N& I 49 (Lat: 33.293250,  Lng: -93.921089),  Route carried "on" structure: ServiceInterstate 49,  Year Built: 2002,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 78 (year 2014),  Truck Traffic: 1%,  Average Future Daily Traffic: 250 (year 2034),  Design Load: HS 20+Mod,  Features Intersected: Mill Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.943,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: X1129,  Location: 1.77M.S JCT.CR. 26N& I 49 (Lat: 33.297350,  Lng: -93.926108),  Route carried "on" structure: Interstate 49,  Year Built: 2002,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 9,200 (year 2018),  Truck Traffic: 33%,  Average Future Daily Traffic: 12,000 (year 2038),  Design Load: H 20,  Features Intersected: MILL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 33.603,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 490,  Subroute: 49),  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.2m (17.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 39.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: X113,  Location: 1.61MI.S.Jct.CR26N& I 49 (Lat: 33.299100,  Lng: -93.927931),  Route carried "on" structure: Interstate 49,  Year Built: 2003,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 9,200 (year 2018),  Truck Traffic: 33%,  Average Future Daily Traffic: 12,000 (year 2038),  Design Load: H 20,  Features Intersected: MILL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 33.877,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 490,  Subroute: 49),  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.2m (17.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 39.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 6784,  Location: 0.5 MI. N. OF FOUKE (Lat: 33.269422,  Lng: -93.897706),  Route carried "under" structure: Interstate 49,  Structure Length: 0. m,  Average Daily Traffic: 3,450 (year 2014),  Truck Traffic: 1%,  Features Intersected: I 49 N.B & S.B-18.34,  Facility Carried by Structure: N. FOUKE RD.-0.40
Minimum Vertical Clearance: 6.40m (21.00ft),  Kilometerpoint: 29.515,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 6784,  Location: 0.5 MI. N. OF FOUKE (Lat: 33.269422,  Lng: -93.897706),  Route carried "under" structure: Interstate 49,  Structure Length: 0. m,  Average Daily Traffic: 3,450 (year 2014),  Truck Traffic: 1%,  Features Intersected: I 49 N.B & S.B-18.34,  Facility Carried by Structure: N. FOUKE RD.-0.40
Minimum Vertical Clearance: 5.88m (19.29ft),  Kilometerpoint: 29.515,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 6785,  Location: 2.5 MI. NORTH OF FOUKE (Lat: 33.291114,  Lng: -93.919117),  Route carried "under" structure: Interstate 49,  Structure Length: 0. m,  Average Daily Traffic: 3,450 (year 2014),  Truck Traffic: 1%,  Features Intersected: I 49 N.&S.BND.20.31,  Facility Carried by Structure: C.R.26 ZONE E-0.65
Minimum Vertical Clearance: 6.06m (19.88ft),  Kilometerpoint: 32.686,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 6785,  Location: 2.5 MI. NORTH OF FOUKE (Lat: 33.291114,  Lng: -93.919117),  Route carried "under" structure: Interstate 49,  Structure Length: 0. m,  Average Daily Traffic: 3,450 (year 2014),  Truck Traffic: 1%,  Features Intersected: I 49 N.&S.BND.20.31,  Facility Carried by Structure: C.R.26 ZONE E-0.65
Minimum Vertical Clearance: 5.27m (17.29ft),  Kilometerpoint: 32.686,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: A6736,  Location: 2.5 MI. SO. OF FOUKE (Lat: 33.224617,  Lng: -93.873603),  Route carried "under" structure: State highway 134,  Structure Length: 0. m,  Average Daily Traffic: 390 (year 2014),  Truck Traffic: 1%,  Features Intersected: S.H. 134- 01 - 0.80,  Facility Carried by Structure: I 49 S.B. -14.63
Minimum Vertical Clearance: 4.90m (16.08ft),  Kilometerpoint: 1.287,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: A6783,  Location: 0.5 MI. WEST OF FOUKE (Lat: 33.258150,  Lng: -93.895939),  Route carried "under" structure: County highway 7,  Structure Length: 0. m,  Average Daily Traffic: 250 (year 2003),  Truck Traffic: 1%,  Features Intersected: CO. RD. 7 - E- 0.10
Minimum Vertical Clearance: 6.30m (20.67ft),  Kilometerpoint: 0.161,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: A6832,  Location: 0.5 MI. SO. OF FOUKE (Lat: 33.249400,  Lng: -93.886131),  Route carried "under" structure: US 71,  Structure Length: 0. m,  Average Daily Traffic: 1,900 (year 2014),  Truck Traffic: 1%,  Features Intersected: U.S.71- 01- 16.45,  Facility Carried by Structure: I 49 S.B.-16.73
Minimum Vertical Clearance: 6.03m (19.78ft),  Kilometerpoint: 26.474,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: B6736,  Location: 2.5 MI. SO. OF FOUKE (Lat: 33.224608,  Lng: -93.873261),  Route carried "under" structure: State highway 134,  Structure Length: 0. m,  Average Daily Traffic: 390 (year 2014),  Truck Traffic: 1%,  Features Intersected: S.H. 134,  Facility Carried by Structure: I 49 N.B. Lns
Minimum Vertical Clearance: 4.75m (15.58ft),  Kilometerpoint: 1.287,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: B6783,  Location: 0.5 MI W OF FOUKE (Lat: 33.258281,  Lng: -93.895639),  Route carried "under" structure: County highway 7,  Structure Length: 0. m,  Average Daily Traffic: 250 (year 2003),  Truck Traffic: 1%,  Features Intersected: CO. RD. 7 ZONE -E
Minimum Vertical Clearance: 5.39m (17.68ft),  Kilometerpoint: 0.161,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: B6832,  Location: 0.5 MI. SO. OF FOUKE. (Lat: 33.249731,  Lng: -93.886111),  Route carried "under" structure: US 71,  Structure Length: 0. m,  Average Daily Traffic: 1,900 (year 2014),  Truck Traffic: 1%,  Features Intersected: U.S 71-SEC.01-16.47,  Facility Carried by Structure: I 49- N.B.-16.73
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 26.506,  Length of Maximum Span: 0.0m

Discuss Fouke, Arkansas (AR) on our hugely popular Arkansas forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.