Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for James City, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 26Number of bridges
  • 1,145ft / 349mTotal length
  • 405,375Total average daily traffic
  • 47,207Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for James City
  • No street view available for this location

New bridges in James City, NC - historical statistics
  • New bridges - historical statistics
  • 111970-1979
  • 131990-1999
  • 12000-2009
  • 12010-2019
Average Bridge Daily Traffic in James City, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 63.6%Good
  • 36.4%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 9.1%Very good
  • 63.6%Good
  • 18.2%Satisfactory
  • 9.1%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Satisfactory
  • 50.0%Fair
Find on map >>   Show street view

Structure Number: 49006,  Location: 0.1MI. N. JCT. SR1004 (Lat: 35.101217,  Lng: -77.037108),  Route carried "on" structure: Business US 17,  Year Built: 2010,  Status: Open,  Structure Length: 53.70m (176.18ft),  Average Daily Traffic: 11,000 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 22,000 (year 2040),  Design Load: H 10,  Features Intersected: TRENT RIVER
Minimum Vertical Clearance: 30.44m (99.87ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 10.0m (32.8ft),  Navigation Control: Yes ( Vertical Clearance: 5.0m (16.4ft), Horizontal Clearance: 30.1m (98.8ft)),  Material/Design: Steel,  Design/Construction: Movable - Bascule,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 18,  Length of Maximum Span: 59.7m (195.9ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 0.0m,  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 56.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: Febuary 2022,  Critical Feature Inspection Date: Febuary 2020,  Underwater Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 490085,  Location: 2.7 MI.E.JCT.US17 (Lat: 35.094161,  Lng: -77.040894),  Route carried "on" structure: Bypass US 70,  Year Built: 1976,  Status: Open,  Structure Length: 12.31m (40.39ft),  Average Daily Traffic: 26,250 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 52,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR1004, A&EC RAILROAD
Minimum Vertical Clearance: 5.56m (18.24ft),  Kilometerpoint: 127.103,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 10.6m (34.8ft),  Skew: 19 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 37.7m (123.7ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 82.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 490086,  Location: 2.7 MI. E. JCT.JCT. US17 (Lat: 35.094411,  Lng: -77.040694),  Route carried "on" structure: Bypass US 70,  Year Built: 1976,  Status: Open,  Structure Length: 10.57m (34.68ft),  Average Daily Traffic: 26,250 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 52,500 (year 2040),  Design Load: HS 20,  Features Intersected: SR1004 & ATL&EC RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 10 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 37.7m (123.7ft),  Curb-To-Curb Width: 14.5m (47.6ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 83.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 490087,  Location: 1.1MI.E.JCT.SR 1200 (Lat: 35.092803,  Lng: -77.038319),  Route carried "on" structure: Bypass US 70,  Year Built: 1977,  Status: Open,  Structure Length: 8.10m (26.57ft),  Average Daily Traffic: 25,250 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 50,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US17S,US70W BUS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 44.8m (147.0ft),  Curb-To-Curb Width: 14.4m (47.2ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 80.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 490088,  Location: 1.1MI.E. JCT.SR1200 (Lat: 35.093136,  Lng: -77.038306),  Route carried "on" structure: Bypass US 70,  Year Built: 1977,  Status: Open,  Structure Length: 8.10m (26.57ft),  Average Daily Traffic: 23,500 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 47,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US17, US70 BUS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Skew: 14 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 44.8m (147.0ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 81.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 490089,  Location: 2.8 MI. E. JCT. US17 (Lat: 35.091619,  Lng: -77.037211),  Route carried "on" structure: US 70,  Year Built: 1975,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 50,500 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 101,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SCOTTS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 45.1m (148.0ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Good,  Culverts: Fair,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2021,  Underwater Inspection Date: September 2021
Find on map >>   Show street view

Structure Number: 490221,  Location: 0.15 MI.S.JCT.SR1004 (Lat: 35.094514,  Lng: -77.037967),  Route carried "on" structure: Business US 70,  Year Built: 1998,  Status: Open,  Structure Length: 5.33m (17.49ft),  Average Daily Traffic: 5,500 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 11,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US70 RAMP
Minimum Vertical Clearance: 5.85m (19.19ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 11.2m (36.7ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 50.5m (165.7ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 58.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 490232,  Location: @ JCT. US70 (Lat: 35.094747,  Lng: -77.038431),  Route carried "on" structure: Ramp US 17,  Year Built: 1999,  Status: Open,  Structure Length: 60.41m (198.20ft),  Average Daily Traffic: 13,125 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 26,250 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US70E RP, 70W BUS, N&S R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 11,  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 14,  Length of Maximum Span: 52.1m (170.9ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 71.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2021,  Underwater Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 490233,  Location: @ JCT US17 & US70BUS. (Lat: 35.093342,  Lng: -77.040275),  Route carried "on" structure: Ramp US 17,  Year Built: 1999,  Status: Open,  Structure Length: 7.43m (24.38ft),  Average Daily Traffic: 2,750 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 5,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NORFOLK & SOUTHERN R/R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.8m (120.7ft),  Curb-To-Curb Width: 8.3m (27.2ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 66.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 490234,  Location: @ JCT. US70BUS & US17 (Lat: 35.093222,  Lng: -77.034919),  Route carried "on" structure: Business US 70,  Year Built: 1999,  Status: Open,  Structure Length: 38.74m (127.10ft),  Average Daily Traffic: 13,125 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 26,250 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NEUSE R. & SCOTTS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 42.9m (140.7ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 490235,  Location: AT NEUSE RIVER & US17B (Lat: 35.093056,  Lng: -77.034728),  Route carried "on" structure: Ramp US 17,  Year Built: 1999,  Status: Open,  Structure Length: 54.04m (177.30ft),  Average Daily Traffic: 13,125 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 26,250 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NEUSE RIVER & SCO
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 13,  Length of Maximum Span: 41.4m (135.8ft),  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2021,  Underwater Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 490236,  Location: AT JCT. US17&US70BUS (Lat: 35.097083,  Lng: -77.033444),  Route carried "on" structure: Ramp US 70,  Year Built: 1999,  Status: Open,  Structure Length: 89.12m (292.39ft),  Average Daily Traffic: 13,250 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 26,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NEUSE RIVER
Minimum Vertical Clearance: 7.87m (25.82ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.8m (38.7ft),  Navigation Control: Yes ( Vertical Clearance: 20.1m (65.9ft), Horizontal Clearance: 54.8m (179.8ft)),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 22,  Length of Maximum Span: 75.8m (248.7ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2021,  Underwater Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1330264,  Location: 500 FT. WEST JCT. US17 (Lat: 34.746147,  Lng: -77.459903),  Route carried "on" structure: Bypass US 17,  Year Built: 2006,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 28,000 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 56,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: EDWARDS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 5 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: 490085,  Location: 2.7 MI.E.JCT.US17 (Lat: 35.094161,  Lng: -77.040894),  Route carried "under" structure: State highway 1004,  Year Built: 1976,  Structure Length: 0. m,  Average Daily Traffic: 7,000 (year 2019),  Truck Traffic: 7%,  Features Intersected: US70E
Minimum Vertical Clearance: 9.06m (29.72ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.7m (123.7ft)

Find on map >>   Show street view

Structure Number: 490086,  Location: 2.7 MI. E. JCT.JCT. US17 (Lat: 35.094411,  Lng: -77.040694),  Route carried "under" structure: State highway 1004,  Year Built: 1976,  Structure Length: 0. m,  Average Daily Traffic: 7,000 (year 2019),  Truck Traffic: 7%,  Features Intersected: US70 WBL
Minimum Vertical Clearance: 8.77m (28.77ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.7m (123.7ft)

Find on map >>   Show street view

Structure Number: 490087,  Location: 1.1MI.E.JCT.SR 1200 (Lat: 35.092803,  Lng: -77.038319),  Route carried "under" structure: Ramp US 70,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 5,500 (year 2019),  Truck Traffic: 7%,  Features Intersected: US70 EBL
Minimum Vertical Clearance: 5.29m (17.36ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 44.8m (147.0ft)

Find on map >>   Show street view

Structure Number: 490087,  Location: 1.1MI.E.JCT.SR 1200 (Lat: 35.092803,  Lng: -77.038319),  Route carried "under" structure: Ramp US 17,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 12,625 (year 2019),  Truck Traffic: 12%,  Features Intersected: US70 EBL
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 44.8m (147.0ft)

Find on map >>   Show street view

Structure Number: 490088,  Location: 1.1MI.E. JCT.SR1200 (Lat: 35.093136,  Lng: -77.038306),  Route carried "under" structure: Ramp US 17,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 12,000 (year 2015),  Truck Traffic: 12%,  Features Intersected: US70W.BYP
Minimum Vertical Clearance: 6.51m (21.36ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 44.8m (147.0ft)

Find on map >>   Show street view

Structure Number: 490088,  Location: 1.1MI.E. JCT.SR1200 (Lat: 35.093136,  Lng: -77.038306),  Route carried "under" structure: Business US 70,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 23,500 (year 2018),  Truck Traffic: 12%,  Features Intersected: US70W.BYP
Minimum Vertical Clearance: 6.37m (20.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 44.8m (147.0ft)

Find on map >>   Show street view

Structure Number: 490221,  Location: 0.15 MI.S.JCT.SR1004 (Lat: 35.094514,  Lng: -77.037967),  Route carried "under" structure: Ramp US 70,  Year Built: 1998,  Structure Length: 0. m,  Average Daily Traffic: 12,625 (year 2019),  Truck Traffic: 12%,  Features Intersected: US70 BUS. WBL
Minimum Vertical Clearance: 6.27m (20.57ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 50.5m (165.7ft)

Find on map >>   Show street view

Structure Number: 490232,  Location: @ JCT. US70 (Lat: 35.094747,  Lng: -77.038431),  Route carried "under" structure: State highway 1004,  Year Built: 1999,  Structure Length: 0. m,  Average Daily Traffic: 6,400 (year 2018),  Truck Traffic: 7%,  Features Intersected: US17 SBL RAMP
Minimum Vertical Clearance: 11.14m (36.55ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.1m (170.9ft)

Find on map >>   Show street view

Structure Number: 490232,  Location: @ JCT. US70 (Lat: 35.094747,  Lng: -77.038431),  Route carried "under" structure: City street ,  Year Built: 1999,  Structure Length: 0. m,  Average Daily Traffic: 100 (year 2015),  Truck Traffic: 7%,  Features Intersected: US17 SBL RAMP,  Facility Carried by Structure: TRENT VILLA DRIVE
Minimum Vertical Clearance: 9.62m (31.56ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.1m (170.9ft)

Find on map >>   Show street view

Structure Number: 490232,  Location: @ JCT. US70 (Lat: 35.094747,  Lng: -77.038431),  Route carried "under" structure: Business US 70,  Year Built: 1999,  Structure Length: 0. m,  Average Daily Traffic: 11,750 (year 2018),  Truck Traffic: 12%,  Features Intersected: US17 SBL RAMP
Minimum Vertical Clearance: 5.89m (19.32ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.1m (170.9ft)

Find on map >>   Show street view

Structure Number: 490232,  Location: @ JCT. US70 (Lat: 35.094747,  Lng: -77.038431),  Route carried "under" structure: Ramp US 70,  Year Built: 1999,  Structure Length: 0. m,  Average Daily Traffic: 5,500 (year 2017),  Truck Traffic: 12%,  Features Intersected: US17 SBL RAMP
Minimum Vertical Clearance: 13.76m (45.14ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.1m (170.9ft)

Find on map >>   Show street view

Structure Number: 490232,  Location: @ JCT. US70 (Lat: 35.094747,  Lng: -77.038431),  Route carried "under" structure: Bypass US 70,  Year Built: 1999,  Structure Length: 0. m,  Average Daily Traffic: 23,500 (year 2018),  Truck Traffic: 12%,  Features Intersected: US17 SBL RAMP
Minimum Vertical Clearance: 7.67m (25.16ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.1m (170.9ft)

Find on map >>   Show street view

Structure Number: 490232,  Location: @ JCT. US70 (Lat: 35.094747,  Lng: -77.038431),  Route carried "under" structure: Bypass US 70,  Year Built: 1999,  Structure Length: 0. m,  Average Daily Traffic: 26,250 (year 2018),  Truck Traffic: 12%,  Features Intersected: US17 SBL RAMP
Minimum Vertical Clearance: 12.67m (41.57ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.1m (170.9ft)

Discuss James City, North Carolina (NC) on our hugely popular North Carolina forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.