Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Jonesboro, Indiana (IN)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 14Number of bridges
  • 115ft / 35.2mTotal length
  • 50,555Total average daily traffic
  • 11,076Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Jonesboro
  • No street view available for this location

New bridges in Jonesboro, IN - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 11930-1939
  • 71960-1969
  • 11970-1979
  • 21980-1989
  • 11990-1999
  • 12010-2019
Reconstructed bridges in Jonesboro, IN - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 01960-1969
  • 01970-1979
  • 01980-1989
  • 11990-1999
  • 22000-2009
Average Bridge Daily Traffic in Jonesboro, IN
Average Bridge Truck Traffic in Jonesboro, IN
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 10.0%Very good
  • 60.0%Good
  • 30.0%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 20.0%Very good
  • 50.0%Good
  • 30.0%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 80.0%Good
  • 20.0%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 36.4%Good
  • 27.3%Satisfactory
  • 27.3%Fair
  • 9.1%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Good
  • 50.0%Satisfactory
Find on map >>   Show street view

Structure Number: 389,  Location: 00.05 N SR 22 (Lat: 40.489600,  Lng: -85.628069),  Route carried "on" structure: State highway 15,  Year Built: 1938,  Year Reconstructed: 1964,  Status: Open,  Structure Length: 2.25m (7.38ft),  Average Daily Traffic: 8,754 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 16,538 (year 2031),  Design Load: H 20,  Features Intersected: BACK CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.080,  Lanes on structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 30 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 24.4m (80.1ft),  Out-to-Out Width: 29.2m (95.8ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 39575,  Location: 00.79 N SR 26 (Lat: 40.434019,  Lng: -85.546711),  Route carried "on" structure: County highway ,  Year Built: 1963,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 6.74m (22.11ft),  Average Daily Traffic: 966 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,574 (year 2031),  Design Load: HS 20,  Features Intersected: I-69 NB/SB,  Facility Carried by Structure: WHEELING PIKE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.9m (68.6ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 9.0m (29.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 61.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 2700101,  Location: 00.07 MI W of FAIRMOUNT A (Lat: 40.467181,  Lng: -85.636069),  Route carried "on" structure: County highway 28,  Year Built: 1968,  Status: Open,  Structure Length: 2.48m (8.14ft),  Average Daily Traffic: 630 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 960 (year 2041),  Design Load: HS 20,  Features Intersected: BACK CREEK,  Facility Carried by Structure: CR 600S
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.7m (31.8ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 41.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2700108,  Location: 00.31 MI N of CR 700 S (Lat: 40.456161,  Lng: -85.644689),  Route carried "on" structure: County highway 33,  Year Built: 1965,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 1.87m (6.14ft),  Average Daily Traffic: 3,420 (year 2021),  Truck Traffic: 10%,  Average Future Daily Traffic: 5,230 (year 2041),  Design Load: HS 20,  Features Intersected: BACK CREEK,  Facility Carried by Structure: CR 150E
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 6.7m (22.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 42.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 270011,  Location: 00.55 MI S of WHEELING PK (Lat: 40.435250,  Lng: -85.563500),  Route carried "on" structure: County highway 51,  Year Built: 1984,  Status: Open,  Structure Length: 1.50m (4.92ft),  Average Daily Traffic: 110 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 170 (year 2041),  Design Load: HS 20,  Features Intersected: BARREN CREEK,  Facility Carried by Structure: CR 575E
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 4.6m (15.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 36.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2700111,  Location: 00.40 E MAIN ST (Lat: 40.476211,  Lng: -85.620400),  Route carried "on" structure: City street ,  Year Built: 1984,  Status: Open,  Structure Length: 9.43m (30.94ft),  Average Daily Traffic: 1,470 (year 2021),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,250 (year 2041),  Design Load: HS 20,  Features Intersected: MISSISSINEWA RIVER,  Facility Carried by Structure: 10TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 18.8m (61.7ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Poor,  Operating Rating: 57.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 2700147,  Location: 00.11 MI N of SR 22 (Lat: 40.490361,  Lng: -85.626819),  Route carried "on" structure: City street ,  Year Built: 1994,  Status: Open,  Structure Length: 2.51m (8.23ft),  Average Daily Traffic: 2,420 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 3,700 (year 2041),  Design Load: HS 20,  Features Intersected: BACK CREEK,  Facility Carried by Structure: WATER ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 24.2m (79.4ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 30.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2700153,  Location: 00.05 MI W of FAIRMOUNT A (Lat: 40.477111,  Lng: -85.631561),  Route carried "on" structure: City street ,  Year Built: 1960,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 1,050 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,600 (year 2041),  Design Load: HS 20,  Features Intersected: BACK CREEK,  Facility Carried by Structure: 9TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.2m (46.6ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 46.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 2700155,  Location: 00.08 MI W of SR 15 (Lat: 40.487089,  Lng: -85.629281),  Route carried "on" structure: City street ,  Year Built: 1965,  Status: Open,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 470 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 720 (year 2041),  Features Intersected: BACK CREEK,  Facility Carried by Structure: PEARL ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.4m (11.2ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 21.6m (70.9ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 33.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 26.1 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2700156,  Location: 00.17 MI W of SR 15 (Lat: 40.480481,  Lng: -85.631089),  Route carried "on" structure: City street ,  Year Built: 1973,  Status: Open,  Structure Length: 3.54m (11.61ft),  Average Daily Traffic: 3,370 (year 2021),  Truck Traffic: 10%,  Average Future Daily Traffic: 5,150 (year 2041),  Design Load: HS 20,  Features Intersected: BACK CREEK,  Facility Carried by Structure: 6TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.1m (39.7ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 45.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 270079,  Location: 00.21 MI. W. of BOOTS ST (Lat: 40.550061,  Lng: -85.665111),  Route carried "on" structure: City street ,  Year Built: 1921,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 1,000 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,530 (year 2041),  Design Load: HS 20,  Features Intersected: BOOTS CREEK,  Facility Carried by Structure: 12TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.4m (27.6ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 2700799,  Location: 00.08 MI W of MAIN STREET (Lat: 40.484919,  Lng: -85.629300),  Route carried "on" structure: City street ,  Year Built: 2010,  Status: Open,  Structure Length: 1.66m (5.45ft),  Average Daily Traffic: 840 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,280 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: BACK CREEK,  Facility Carried by Structure: 2ND ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.3m (50.2ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 39575,  Location: 00.79 N SR 26 (Lat: 40.434019,  Lng: -85.546731),  Route carried "under" structure: Interstate 69,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 12,895 (year 2019),  Truck Traffic: 37%,  Features Intersected: I-69 SB,  Facility Carried by Structure: WHEELING PIKE
Minimum Vertical Clearance: 5.66m (18.57ft),  Kilometerpoint: 411.558,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.9m (68.6ft)

Find on map >>   Show street view

Structure Number: 39575,  Location: 00.79 N SR 26 (Lat: 40.434019,  Lng: -85.546731),  Route carried "under" structure: Interstate 69,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 13,160 (year 2019),  Truck Traffic: 37%,  Features Intersected: I-69 SB,  Facility Carried by Structure: WHEELING PIKE
Minimum Vertical Clearance: 5.66m (18.57ft),  Kilometerpoint: 411.558,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.9m (68.6ft)

Discuss Jonesboro, Indiana (IN) on our hugely popular Indiana forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.