Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Kingston, Pennsylvania (PA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 11Number of bridges
  • 92ft / 28.3mTotal length
  • $2,089,000Total costs
  • 154,471Total average daily traffic
  • 6,517Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Kingston
  • No street view available for this location

New bridges in Kingston, PA - historical statistics
  • New bridges - historical statistics
  • 31970-1979
  • 61980-1989
  • 22010-2019
Average Bridge Daily Traffic in Kingston, PA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 80.0%Good
  • 20.0%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 40.0%Very good
  • 20.0%Good
  • 40.0%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 60.0%Good
  • 40.0%Fair
Find on map >>   Show street view

Structure Number: 23882,  Location: KINGSTON BORO OVER TR 11 (Lat: 41.275697,  Lng: -75.882275),  Route carried "on" structure: State highway 309,  Year Built: 1980,  Status: Open,  Structure Length: 5.03m (16.50ft),  Average Daily Traffic: 31,996 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 45,364 (year 2032),  Design Load: HS 20,  Features Intersected: TR 11 WYOMING AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 44.722,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.1m (79.1ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 29.6m (97.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 24.1m (79.1ft),  Out-to-Out Width: 26.1m (85.6ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 86.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.00m (16.40ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Bridge Improvement Cost: $25,000,  Roadway Improvement Cost: $100,000,  Total Project Cost: $334,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 23883,  Location: KINGSTON BO OVER SR 1015 (Lat: 41.276694,  Lng: -75.885456),  Route carried "on" structure: State highway 309,  Year Built: 1980,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 12.74m (41.80ft),  Average Daily Traffic: 40,149 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 55,586 (year 2032),  Design Load: HS 20,  Features Intersected: SR 1015 & MERCER AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 44.722,  Lanes on structure: 3,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 30.2m (99.1ft),  Skew: 35 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 34.7m (113.8ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 30.2m (99.1ft),  Out-to-Out Width: 32.5m (106.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 12.70m (41.67ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Bridge Improvement Cost: $130,000,  Roadway Improvement Cost: $383,000,  Total Project Cost: $1,755,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 23964,  Location: KINGSTON BORO OVER TR 309 (Lat: 41.271933,  Lng: -75.876583),  Route carried "on" structure: State highway ,  Year Built: 1976,  Status: Open,  Structure Length: 6.34m (20.80ft),  Average Daily Traffic: 17,075 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 18,871 (year 2032),  Design Load: HS 20,  Features Intersected: SR 0309 TR 309,  Facility Carried by Structure: SR 1006 RUTTER AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 21 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 37.2m (122.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 22.6m (74.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 7.30m (23.95ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 47756,  Location: PLAINS TWP .3 M S TR 309 (Lat: 41.262294,  Lng: -75.866956),  Route carried "on" structure: State highway ,  Year Built: 2012,  Status: Open,  Structure Length: 2.65m (8.69ft),  Average Daily Traffic: 15,869 (year 2022),  Truck Traffic: 2%,  Average Future Daily Traffic: 19,803 (year 2033),  Design Load: HL 93,  Features Intersected: LUZ CO RAIL AUTHORITY,  Facility Carried by Structure: SR 2004 N.RIVER ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.057,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.9m (85.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 62.5 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 54656,  Location: 0.6M W SR 309 (Lat: 41.298589,  Lng: -75.933717),  Route carried "on" structure: County highway ,  Year Built: 2017,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 500 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 650 (year 2035),  Design Load: HL 93,  Features Intersected: HUNTSVILLE CREEK,  Facility Carried by Structure: HILLSIDE ROAD CR16
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.609,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.5m (50.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 54.8 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 23882,  Location: KINGSTON BORO OVER TR 11 (Lat: 41.275697,  Lng: -75.882275),  Route carried "under" structure: US 11,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 8,173 (year 2021),  Truck Traffic: 3%,  Features Intersected: TR 11 WYOMING AVENUE,  Facility Carried by Structure: SR 0309 TR 309
Minimum Vertical Clearance: 4.48m (14.70ft),  Kilometerpoint: 44.212,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.6m (97.1ft)

Find on map >>   Show street view

Structure Number: 23882,  Location: KINGSTON BORO OVER TR 11 (Lat: 41.275697,  Lng: -75.882275),  Route carried "under" structure: US 11,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 8,613 (year 2021),  Truck Traffic: 4%,  Features Intersected: TR 11 WYOMING AVENUE,  Facility Carried by Structure: SR 0309 TR 309
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 44.209,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.6m (97.1ft)

Find on map >>   Show street view

Structure Number: 23883,  Location: KINGSTON BO OVER SR 1015 (Lat: 41.276694,  Lng: -75.885456),  Route carried "under" structure: City street ,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 100 (year 2003),  Truck Traffic: 10%,  Features Intersected: SR 1015 & MERCER AVE,  Facility Carried by Structure: TR 309, RAMPS E&F
Minimum Vertical Clearance: 4.67m (15.32ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.7m (113.8ft)

Find on map >>   Show street view

Structure Number: 23883,  Location: KINGSTON BO OVER SR 1015 (Lat: 41.276694,  Lng: -75.885456),  Route carried "under" structure: City street ,  Year Built: 1980,  Structure Length: 0. m,  Features Intersected: SR 1015 & MERCER AVE,  Facility Carried by Structure: TR 309, RAMPS E&F
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.7m (113.8ft)

Find on map >>   Show street view

Structure Number: 23964,  Location: KINGSTON BORO OVER TR 309 (Lat: 41.271933,  Lng: -75.876583),  Route carried "under" structure: State highway 309,  Year Built: 1976,  Structure Length: 0. m,  Average Daily Traffic: 15,817 (year 2021),  Truck Traffic: 5%,  Features Intersected: SR 0309 TR 309,  Facility Carried by Structure: SR 1006 RUTTER AVE
Minimum Vertical Clearance: 4.80m (15.75ft),  Kilometerpoint: 44.230,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.2m (122.0ft)

Find on map >>   Show street view

Structure Number: 23964,  Location: KINGSTON BORO OVER TR 309 (Lat: 41.271933,  Lng: -75.876583),  Route carried "under" structure: State highway 309,  Year Built: 1976,  Structure Length: 0. m,  Average Daily Traffic: 16,179 (year 2021),  Truck Traffic: 4%,  Features Intersected: SR 0309 TR 309,  Facility Carried by Structure: SR 1006 RUTTER AVE
Minimum Vertical Clearance: 4.80m (15.75ft),  Kilometerpoint: 44.112,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.2m (122.0ft)

Discuss Kingston, Pennsylvania (PA) on our hugely popular Pennsylvania forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.