Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Little Canada, Minnesota (MN)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 22Number of bridges
  • 400ft / 122mTotal length
  • 1,408,011Total average daily traffic
  • 64,263Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Little Canada
  • No street view available for this location

New bridges in Little Canada, MN - historical statistics
  • New bridges - historical statistics
  • 11960-1969
  • 31980-1989
  • 72000-2009
  • 102010-2019
  • 12020-2022
Average Bridge Daily Traffic in Little Canada, MN
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 27.3%Very good
  • 54.5%Good
  • 18.2%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 63.6%Very good
  • 18.2%Good
  • 9.1%Satisfactory
  • 9.1%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 81.8%Good
  • 9.1%Satisfactory
  • 9.1%Fair
Find on map >>   Show street view

Structure Number: 62001,  Location: 0.6 MI S OF JCT TH 694 (Lat: 45.035828,  Lng: -93.106217),  Route carried "on" structure: County highway 49,  Year Built: 1986,  Status: Open,  Structure Length: 4.10m (13.45ft),  Average Daily Traffic: 12,800 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 12,800 (year 2039),  Design Load: HS 20,  Features Intersected: BNSF RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 17.4m (57.1ft),  Out-to-Out Width: 21.7m (71.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 54.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 62631,  Location: 0.8 MI W OF JCT TH 35E (Lat: 45.007644,  Lng: -93.105897),  Route carried "on" structure: County highway 49,  Year Built: 2011,  Status: Open,  Structure Length: 5.18m (16.99ft),  Average Daily Traffic: 23,900 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 23,900 (year 2039),  Design Load: HL 93,  Features Intersected: TH 36
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 7,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 23.8m (78.1ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 25.2m (82.7ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 29.0m (95.1ft),  Out-to-Out Width: 35.4m (116.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 64.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 62632,  Location: 0.9 MI W OF JCT TH 35E (Lat: 45.007622,  Lng: -93.107781),  Route carried "on" structure: Ramp State highway 3739,  Year Built: 2011,  Status: Open,  Structure Length: 7.67m (25.16ft),  Average Daily Traffic: 1 (year 2012),  Truck Traffic: 4%,  Average Future Daily Traffic: 1 (year 2030),  Design Load: HL 93,  Features Intersected: TH 36
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 37.2m (122.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 99.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 62633,  Location: 0.7 MI W OF JCT TH 35E (Lat: 45.007611,  Lng: -93.104828),  Route carried "on" structure: Ramp State highway 5347,  Year Built: 2011,  Status: Open,  Structure Length: 5.76m (18.90ft),  Average Daily Traffic: 7,210 (year 2011),  Truck Traffic: 5%,  Average Future Daily Traffic: 7,210 (year 2033),  Design Load: HL 93,  Features Intersected: TH 36
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 22 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.8m (91.2ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 59.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 62896,  Location: 0.9 MI N OF JCT TH 36 (Lat: 45.022900,  Lng: -93.089731),  Route carried "on" structure: County highway 21,  Year Built: 1987,  Status: Open,  Structure Length: 6.06m (19.88ft),  Average Daily Traffic: 13,000 (year 2015),  Average Future Daily Traffic: 13,000 (year 2039),  Design Load: HS 20,  Features Intersected: I 35E
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.6m (97.1ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 25.7m (84.3ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 73.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 62902,  Location: AT THE W JCT I 35E; 694 (Lat: 45.034783,  Lng: -93.089219),  Route carried "on" structure: Ramp Interstate 6430,  Year Built: 2006,  Status: Open,  Structure Length: 58.76m (192.78ft),  Average Daily Traffic: 23,000 (year 1996),  Truck Traffic: 9%,  Average Future Daily Traffic: 23,000 (year 2029),  Design Load: HS 25 or greater,  Features Intersected: I 35E , I 694; BNSF RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 12,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 82.3m (270.0ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.6m (51.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Fair,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 62904,  Location: AT THE W JCT I 35E; 694 (Lat: 45.037072,  Lng: -93.090914),  Route carried "on" structure: Interstate 694,  Year Built: 2006,  Status: Open,  Structure Length: 4.37m (14.34ft),  Average Daily Traffic: 54,500 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 54,500 (year 2039),  Design Load: HL 93,  Features Intersected: BNSF RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.0m (45.9ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 19.3m (63.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 53.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 62905,  Location: AT THE W JCT TH 694; 35E (Lat: 45.034872,  Lng: -93.086956),  Route carried "on" structure: Interstate 694,  Year Built: 2006,  Status: Open,  Structure Length: 13.29m (43.60ft),  Average Daily Traffic: 54,500 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 54,500 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: I 35E
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 5 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 72.5m (237.9ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 19.3m (63.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 73.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 62914,  Location: AT THE W JCT I 694; 35E (Lat: 45.036981,  Lng: -93.091497),  Route carried "on" structure: Interstate 694,  Year Built: 2006,  Status: Open,  Structure Length: 4.17m (13.68ft),  Average Daily Traffic: 54,500 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 54,500 (year 2039),  Design Load: HL 93,  Features Intersected: BNSF RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.5m (44.3ft),  Curb-To-Curb Width: 26.5m (86.9ft),  Out-to-Out Width: 27.6m (90.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 56.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 62933,  Location: AT JCT 35E & TH36 (Lat: 45.010606,  Lng: -93.089814),  Route carried "on" structure: Interstate 35E,  Year Built: 2015,  Status: Open,  Structure Length: 5.82m (19.09ft),  Average Daily Traffic: 65,000 (year 2017),  Truck Traffic: 5%,  Average Future Daily Traffic: 65,000 (year 2039),  Design Load: HL 93,  Features Intersected: TH 36
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.4m (66.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 28.5m (93.5ft),  Curb-To-Curb Width: 26.7m (87.6ft),  Out-to-Out Width: 26.7m (87.6ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 53.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 62934,  Location: AT JCT TH 36; 35E (Lat: 45.010650,  Lng: -93.089539),  Route carried "on" structure: Interstate 35E,  Year Built: 2014,  Status: Open,  Structure Length: 5.82m (19.09ft),  Average Daily Traffic: 68,000 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 65,000 (year 2039),  Design Load: HL 93,  Features Intersected: TH 36
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.3m (83.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 28.6m (93.8ft),  Curb-To-Curb Width: 25.8m (84.6ft),  Out-to-Out Width: 26.7m (87.6ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 48.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 62J21,  Location: 0.2 MI NE OF JCT CSAH 58 (Lat: 45.023658,  Lng: -93.074644),  Route carried "on" structure: County highway 22,  Year Built: 2021,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 1,600 (year 2020),  Average Future Daily Traffic: 1,600 (year 2040),  Design Load: HL 93,  Features Intersected: GERVAIS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.0m (16.4ft)

Condition: Channel: Excellent,  Culverts: Excellent,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 62631,  Location: 0.8 MI W OF JCT TH 35E (Lat: 45.007644,  Lng: -93.105897),  Route carried "under" structure: State highway 36,  Year Built: 2011,  Structure Length: 0. m,  Average Daily Traffic: 86,000 (year 2019),  Truck Traffic: 3%,  Features Intersected: TH 36,  Facility Carried by Structure: CSAH 49
Minimum Vertical Clearance: 5.40m (17.72ft),  Kilometerpoint: 0.000,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.2m (82.7ft)

Find on map >>   Show street view

Structure Number: 62632,  Location: 0.9 MI W OF JCT TH 35E (Lat: 45.007622,  Lng: -93.107781),  Route carried "under" structure: State highway 36,  Year Built: 2011,  Structure Length: 0. m,  Average Daily Traffic: 86,000 (year 2019),  Truck Traffic: 3%,  Features Intersected: TH 36,  Facility Carried by Structure: CON 3739
Minimum Vertical Clearance: 4.97m (16.31ft),  Kilometerpoint: 0.000,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.2m (122.0ft)

Find on map >>   Show street view

Structure Number: 62633,  Location: 0.7 MI W OF JCT TH 35E (Lat: 45.007611,  Lng: -93.104828),  Route carried "under" structure: State highway 36,  Year Built: 2011,  Structure Length: 0. m,  Average Daily Traffic: 86,000 (year 2019),  Truck Traffic: 3%,  Features Intersected: TH 36,  Facility Carried by Structure: CON 5347
Minimum Vertical Clearance: 5.49m (18.01ft),  Kilometerpoint: 0.000,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.8m (91.2ft)

Find on map >>   Show street view

Structure Number: 62896,  Location: 0.9 MI N OF JCT TH 36 (Lat: 45.022900,  Lng: -93.089731),  Route carried "under" structure: Interstate 35E,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 135,000 (year 2019),  Truck Traffic: 5%,  Features Intersected: I 35E,  Facility Carried by Structure: CSAH 21
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.6m (97.1ft)

Find on map >>   Show street view

Structure Number: 62902,  Location: AT THE W JCT I 35E; 694 (Lat: 45.034783,  Lng: -93.089219),  Route carried "under" structure: Interstate 694,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 109,000 (year 2019),  Truck Traffic: 6%,  Features Intersected: I 35E , I 694; BNSF RR,  Facility Carried by Structure: CON 6430
Minimum Vertical Clearance: 4.94m (16.21ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 82.3m (270.0ft)

Find on map >>   Show street view

Structure Number: 62902,  Location: AT THE W JCT I 35E; 694 (Lat: 45.034783,  Lng: -93.089219),  Route carried "under" structure: Interstate 35E,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 135,000 (year 2019),  Truck Traffic: 5%,  Features Intersected: I 35E , I 694; BNSF RR,  Facility Carried by Structure: CON 6430
Minimum Vertical Clearance: 4.94m (16.21ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 82.3m (270.0ft)

Find on map >>   Show street view

Structure Number: 62905,  Location: AT THE W JCT TH 694; 35E (Lat: 45.034872,  Lng: -93.086956),  Route carried "under" structure: Interstate 35E,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 135,000 (year 2019),  Truck Traffic: 5%,  Features Intersected: I 35E,  Facility Carried by Structure: I 694
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 72.5m (237.9ft)

Find on map >>   Show street view

Structure Number: 62933,  Location: AT JCT 35E & TH36 (Lat: 45.010606,  Lng: -93.089814),  Route carried "under" structure: State highway 36,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 86,000 (year 2019),  Truck Traffic: 3%,  Features Intersected: TH 36,  Facility Carried by Structure: I 35E
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 0.000,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.5m (93.5ft)

Find on map >>   Show street view

Structure Number: 62934,  Location: AT JCT TH 36; 35E (Lat: 45.010650,  Lng: -93.089539),  Route carried "under" structure: State highway 36,  Year Built: 2014,  Structure Length: 0. m,  Average Daily Traffic: 86,000 (year 2019),  Truck Traffic: 3%,  Features Intersected: TH 36,  Facility Carried by Structure: I 35E
Minimum Vertical Clearance: 5.61m (18.41ft),  Kilometerpoint: 0.000,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.6m (93.8ft)

Find on map >>   Show street view

Structure Number: 9212,  Location: 0.3 MI W OF JCT TH 35E (Lat: 45.009450,  Lng: -93.095114),  Route carried "under" structure: State highway 36,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 86,000 (year 2019),  Truck Traffic: 3%,  Features Intersected: TH 36,  Facility Carried by Structure: RAILROAD
Minimum Vertical Clearance: 4.63m (15.19ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 18.8m (61.7ft)

Discuss Little Canada, Minnesota (MN) on our hugely popular Minnesota forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.