  • National Bridge Inventory (NBI) Statistics
  • 16Number of bridges
  • 381ft / 116mTotal length
  • $721,000Total costs
  • 20,992Total average daily traffic
  • 2,081Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Lynch
  • No street view available for this location

New bridges in Lynch, KY - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 11940-1949
  • 21980-1989
  • 81990-1999
  • 32010-2019
  • 12020-2022
Average Bridge Daily Traffic in Lynch, KY
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 7.1%Very good
  • 42.9%Good
  • 42.9%Satisfactory
  • 7.1%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 14.3%Very good
  • 71.4%Good
  • 14.3%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 7.1%Very good
  • 64.3%Good
  • 21.4%Satisfactory
  • 7.1%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 6.7%Excellent
  • 20.0%Very good
  • 60.0%Good
  • 6.7%Satisfactory
  • 6.7%Fair
Find on map >>   Show street view

Structure Number: 48B00154N,  Location: 6.2 MI. SE JCT US 119 (Lat: 36.956389,  Lng: -82.888611),  Route carried "on" structure: State highway 160,  Year Built: 1988,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 224 (year 2019),  Truck Traffic: 14%,  Average Future Daily Traffic: 185 (year 2039),  Features Intersected: LOONEY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.703,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.6m (15.1ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: 48B00155N,  Location: 5.4 MI. S.E. JCT US 119 (Lat: 36.960833,  Lng: -82.898889),  Route carried "on" structure: State highway 160,  Year Built: 1988,  Status: Open,  Structure Length: 2.07m (6.79ft),  Average Daily Traffic: 224 (year 2019),  Truck Traffic: 14%,  Average Future Daily Traffic: 185 (year 2039),  Design Load: HS 20,  Features Intersected: LOONEY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.923,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.7m (67.9ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 0.0m,  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 66.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 48B00160N,  Location: .2 MI. S. LETCHER CO LNE (Lat: 36.999444,  Lng: -82.915000),  Route carried "on" structure: US 119,  Year Built: 1992,  Status: Open,  Structure Length: 4.66m (15.29ft),  Average Daily Traffic: 2,411 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 2,266 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: POOR FORK CUMBERLAND RIV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 62.874,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 79.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 48B00161N,  Location: .8 MI.S. LETCHER CO LINE (Lat: 36.996667,  Lng: -82.925556),  Route carried "on" structure: US 119,  Year Built: 1992,  Status: Open,  Structure Length: 4.85m (15.91ft),  Average Daily Traffic: 2,411 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 2,266 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: POOR FORK CUMBERLAND RIV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 61.865,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 96.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 58.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 48B00163N,  Location: 1.6 MI.S. LETCHER CO LINE (Lat: 36.991389,  Lng: -82.940833),  Route carried "on" structure: US 119,  Year Built: 1990,  Status: Open,  Structure Length: 6.89m (22.60ft),  Average Daily Traffic: 2,411 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 2,266 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: POOR FORK CUMBERLAND RIV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.386,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.9m (75.1ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 65.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 48B00164N,  Location: 1.4 MI.S. LETCHER CO LINE (Lat: 36.993333,  Lng: -82.936389),  Route carried "on" structure: US 119,  Year Built: 1990,  Status: Open,  Structure Length: 4.72m (15.49ft),  Average Daily Traffic: 2,411 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 2,266 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: POOR FORK CUMBERLAND RIV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.836,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 74.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 48B00165N,  Location: 1.1 MI.S. LETCHER CO LINE (Lat: 36.995556,  Lng: -82.931944),  Route carried "on" structure: US 119,  Year Built: 1990,  Status: Open,  Structure Length: 6.61m (21.69ft),  Average Daily Traffic: 2,411 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 2,266 (year 2040),  Design Load: HS 20,  Features Intersected: POOR FORK CUMBERLAND RIV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 61.300,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.4m (80.1ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 73.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 48C00008N,  Location: 500' SW OF JCT US 119 (Lat: 36.993333,  Lng: -82.926944),  Route carried "on" structure: County highway 1020,  Year Built: 1940,  Status: Posted for load,  Structure Length: 1.68m (5.51ft),  Average Daily Traffic: 20 (year 2006),  Average Future Daily Traffic: 2,026 (year 2026),  Features Intersected: POOR FK CUMBERLAND RVR,  Facility Carried by Structure: RASNICK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.027,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 3.7m (12.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 10.7m (35.1ft),  Curb-To-Curb Width: 3.4m (11.2ft),  Out-to-Out Width: 3.7m (12.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Poor,  Channel: Good,  Operating Rating: 36.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 0.16m (0.52ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: September 2021,  Bridge Improvement Cost: $72,000,  Total Project Cost: $72,000,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 48C00195N,  Location: .80 MI W OF LETCHER CO LN (Lat: 36.994722,  Lng: -82.925278),  Route carried "on" structure: Business County highway 1020,  Year Built: 1928,  Status: Posted for load,  Structure Length: 4.85m (15.91ft),  Average Daily Traffic: 3,342 (year 2006),  Average Future Daily Traffic: 2,026 (year 2026),  Design Load: H 15,  Features Intersected: POOR FK CUMBERLAND RVR,  Facility Carried by Structure: OLD HWY 119
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.233,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 5.8m (19.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 32.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 0.48m (1.57ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Bridge Improvement Cost: $501,000,  Total Project Cost: $500,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 67B00117N,  Location: 0.65 MI S JCT US 119 (Lat: 36.996667,  Lng: -82.897778),  Route carried "on" structure: State highway 3403,  Year Built: 1991,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 115 (year 2020),  Average Future Daily Traffic: 100 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: LEWIS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.584,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 4.0m (13.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 6.0m (19.7ft),  Out-to-Out Width: 6.5m (21.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 60.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: High priority of corrective action,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 67B00125N,  Location: .01 MI SOU JCT US 119 (Lat: 37.005000,  Lng: -82.900278),  Route carried "on" structure: State highway 3403,  Year Built: 1992,  Status: Open,  Structure Length: 4.05m (13.29ft),  Average Daily Traffic: 115 (year 2020),  Average Future Daily Traffic: 100 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: POOR FK-CUMBERLAND RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.601,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 8.4m (27.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 78.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 67B00136N,  Location: 1.6 MI NE of Harlan Co (Lat: 37.013725,  Lng: -82.890772),  Route carried "on" structure: US 119,  Year Built: 2015,  Status: Open,  Structure Length: 11.83m (38.81ft),  Average Daily Traffic: 2,074 (year 2018),  Truck Traffic: 13%,  Average Future Daily Traffic: 1,949 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: Poor Frk of Cumberland
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.615,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 28.0m (91.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 83.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 50.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 67B00137N,  Location: 2.15 MI NE of Harlan Co (Lat: 37.015556,  Lng: -82.881111),  Route carried "on" structure: US 119,  Year Built: 2017,  Status: Open,  Structure Length: 57.62m (189.04ft),  Average Daily Traffic: 1,543 (year 2014),  Truck Traffic: 12%,  Average Future Daily Traffic: 1,450 (year 2034),  Design Load: HS 25 or greater,  Features Intersected: KY-3404/P Fk Cumberland
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.462,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.7m (48.2ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 14,  Length of Maximum Span: 42.4m (139.1ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 60.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 47.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 67B00144N,  Location: 0.1 MI S of JCT KY 3619 (Lat: 37.015556,  Lng: -82.883056),  Route carried "on" structure: State highway 3404,  Year Built: 2020,  Status: Open,  Structure Length: 2.53m (8.30ft),  Average Daily Traffic: 526 (year 2018),  Average Future Daily Traffic: 457 (year 2038),  Design Load: Greater than HL93,  Features Intersected: Poor Frk of Cumberland
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.262,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 4.3m (14.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 24.4m (80.1ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 6.9m (22.6ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 66.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 51.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 67C00070N,  Location: SW US 119@ HARLAN CO LINE (Lat: 37.001389,  Lng: -82.908889),  Route carried "on" structure: County highway 1289,  Year Built: 1993,  Status: Open,  Structure Length: 1.71m (5.61ft),  Average Daily Traffic: 228 (year 2019),  Average Future Daily Traffic: 198 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: POOR FORK-CUMBERLAND,  Facility Carried by Structure: SKY VIEW BOTTOM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.134,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.8m (19.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.2m (53.1ft),  Curb-To-Curb Width: 6.0m (19.7ft),  Out-to-Out Width: 6.5m (21.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 61.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.17m (0.56ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $149,000,  Total Project Cost: $149,000,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 67B00137N,  Location: 2.15 MI NE of Harlan Co (Lat: 37.015556,  Lng: -82.881111),  Route carried "under" structure: State highway 3404,  Year Built: 2017,  Structure Length: 0. m,  Average Daily Traffic: 526 (year 2018),  Features Intersected: KY-3404/P Fk Cumberland,  Facility Carried by Structure: US-119
Minimum Vertical Clearance: 12.19m (39.99ft),  Kilometerpoint: 1.197,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 42.4m (139.1ft)