Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Minonk, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 12Number of bridges
  • 102ft / 30.6mTotal length
  • 53,900Total average daily traffic
  • 19,821Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Minonk
  • No street view available for this location

New bridges in Minonk, IL - historical statistics
  • New bridges - historical statistics
  • 61980-1989
  • 51990-1999
  • 12000-2009
Average Bridge Daily Traffic in Minonk, IL
Average Bridge Truck Traffic in Minonk, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 14.3%Very good
  • 42.9%Satisfactory
  • 28.6%Fair
  • 14.3%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 14.3%Very good
  • 28.6%Satisfactory
  • 42.9%Fair
  • 14.3%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 14.3%Very good
  • 14.3%Good
  • 28.6%Satisfactory
  • 42.9%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 33.3%Very good
  • 33.3%Good
  • 33.3%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Good
  • 50.0%Satisfactory
Find on map >>   Show street view

Structure Number: 503461,  Location: E8TH N010 (Lat: 40.927736,  Lng: -89.008283),  Route carried "on" structure: County highway ,  Year Built: 1980,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 25 (year 2016),  Average Future Daily Traffic: 28 (year 2032),  Design Load: HS 20,  Features Intersected: LONG POINT CREEK,  Facility Carried by Structure: E 8TH TR 142B
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.010,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 3.7m (12.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Very good,  Operating Rating: 60.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 503474,  Location: N 1 ST RD E 850 (Lat: 40.941347,  Lng: -88.998714),  Route carried "on" structure: County highway ,  Year Built: 1981,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 50 (year 2016),  Average Future Daily Traffic: 56 (year 2032),  Design Load: HS 20,  Features Intersected: LONG POINT CR,  Facility Carried by Structure: TR 571
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.120,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.2m (17.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2018,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 1020047,  Location: .49 MI W OF IL 251 (Lat: 40.911153,  Lng: -89.057547),  Route carried "on" structure: County highway ,  Year Built: 1989,  Status: Open,  Structure Length: 6.95m (22.80ft),  Average Daily Traffic: 875 (year 2020),  Truck Traffic: 19%,  Average Future Daily Traffic: 3,352 (year 2032),  Design Load: HS 20,  Features Intersected: I-39, US 51,  Facility Carried by Structure: CH 2 (2200 N)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.535,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 50.5m (165.7ft),  Curb-To-Curb Width: 18.9m (62.0ft),  Out-to-Out Width: 19.8m (65.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 73.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1020048,  Location: 3 MI N OF ILL 116 (Lat: 40.896581,  Lng: -89.055342),  Route carried "on" structure: County highway ,  Year Built: 1990,  Status: Open,  Structure Length: 9.05m (29.69ft),  Average Daily Traffic: 200 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 357 (year 2032),  Design Load: HS 20,  Features Intersected: I-39, US 51,  Facility Carried by Structure: TR 41 (2100 N)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.787,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 65.8m (215.9ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 62.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1020049,  Location: 8 MI N OF US 24 (Lat: 40.852994,  Lng: -89.037111),  Route carried "on" structure: State highway 116,  Year Built: 1990,  Status: Open,  Structure Length: 7.01m (23.00ft),  Average Daily Traffic: 1,400 (year 2021),  Truck Traffic: 16%,  Average Future Daily Traffic: 2,253 (year 2032),  Design Load: HS 20,  Features Intersected: I-39, US 51
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 184.458,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 50.7m (166.3ft),  Curb-To-Curb Width: 18.6m (61.0ft),  Out-to-Out Width: 21.1m (69.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 73.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 102316,  Location: 3.0 MI W MINONK (Lat: 40.911375,  Lng: -89.101050),  Route carried "on" structure: County highway ,  Year Built: 1986,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 625 (year 2020),  Truck Traffic: 11%,  Average Future Daily Traffic: 989 (year 2032),  Design Load: HS 20,  Features Intersected: CROW CREEK,  Facility Carried by Structure: FAS 357 CH2
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.914,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 48.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 1023169,  Location: 2 MI W OF US 51 (Lat: 40.896717,  Lng: -89.084464),  Route carried "on" structure: County highway ,  Year Built: 1988,  Status: Open,  Structure Length: 1.69m (5.54ft),  Average Daily Traffic: 150 (year 2020),  Truck Traffic: 20%,  Average Future Daily Traffic: 330 (year 2032),  Design Load: HS 20,  Features Intersected: CROW CREEK,  Facility Carried by Structure: TR 41
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.373,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.1m (52.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Good,  Operating Rating: 56.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 1025018,  Location: 1 MI NE WOODFORD (Lat: 40.853700,  Lng: -89.007681),  Route carried "on" structure: County highway ,  Year Built: 1991,  Status: Open,  Structure Length: 1.29m (4.23ft),  Average Daily Traffic: 50 (year 2021),  Average Future Daily Traffic: 55 (year 2032),  Features Intersected: DRAINAGE DITCH,  Facility Carried by Structure: TR 71, TR 244
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.770,  Lanes on structure: 4,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 5 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.3m (20.7ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 19.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 102503,  Location: 1.5 MI SW MINONK (Lat: 40.882061,  Lng: -89.071158),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 25 (year 2020),  Average Future Daily Traffic: 27 (year 2032),  Design Load: HS 20,  Features Intersected: S BR. CROW CREEK,  Facility Carried by Structure: TR 49
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.467,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 10.4m (34.1ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2018,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 1020047,  Location: .49 MI W OF IL 251 (Lat: 40.911161,  Lng: -89.056511),  Route carried "under" structure: Interstate 39,  Year Built: 1989,  Structure Length: 0. m,  Average Daily Traffic: 17,900 (year 2021),  Truck Traffic: 35%,  Features Intersected: I-39, US 51,  Facility Carried by Structure: CH 2 (2200 N)
Minimum Vertical Clearance: 5.16m (16.93ft),  Kilometerpoint: 44.465,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 50.5m (165.7ft)

Find on map >>   Show street view

Structure Number: 1020048,  Location: 3 MI N OF ILL 116 (Lat: 40.896581,  Lng: -89.055039),  Route carried "under" structure: Interstate 39,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 16,300 (year 2021),  Truck Traffic: 40%,  Features Intersected: I-39, US 51,  Facility Carried by Structure: TR 41 (2100 N)
Minimum Vertical Clearance: 5.54m (18.18ft),  Kilometerpoint: 42.840,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 65.8m (215.9ft)

Find on map >>   Show street view

Structure Number: 1020049,  Location: 8 MI N OF US 24 (Lat: 40.853022,  Lng: -89.036200),  Route carried "under" structure: Interstate 39,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 16,300 (year 2021),  Truck Traffic: 40%,  Features Intersected: I-39, US 51,  Facility Carried by Structure: FAP673 ILL 116
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 37.175,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 50.7m (166.3ft)

Discuss Minonk, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.