Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Park City, Utah (UT)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 17Number of bridges
  • 141ft / 43.0mTotal length
  • 286,771Total average daily traffic
  • 67,257Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Park City
  • No street view available for this location

New bridges in Park City, UT - historical statistics
  • New bridges - historical statistics
  • 101980-1989
  • 11990-1999
  • 42000-2009
  • 22010-2019
Average Bridge Daily Traffic in Park City, UT
Average Bridge Truck Traffic in Park City, UT
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 11.1%Good
  • 88.9%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 66.7%Good
  • 33.3%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 66.7%Good
  • 33.3%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 50.0%Very good
  • 50.0%Good
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Good
  • 50.0%Satisfactory
Find on map >>   Show street view

Structure Number: 43019D,  Location: AT ENT.TO DEER VALLEY LDG (Lat: 40.638164,  Lng: -111.478900),  Route carried "on" structure: ServiceCity street ,  Year Built: 1996,  Status: Open,  Structure Length: 4.69m (15.39ft),  Average Daily Traffic: 2,350 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 2,855 (year 2040),  Design Load: HL 93,  Features Intersected: DEER VALLEY LODGE ENT.,  Facility Carried by Structure: DEER VALLEY DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.086,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 6.7m (22.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 13.6m (44.6ft),  Out-to-Out Width: 32.0m (105.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 19.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 25 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: C 95,  Location: On Guardsman Pass Road (Lat: 40.607892,  Lng: -111.507383),  Route carried "on" structure: ServiceCity street ,  Year Built: 2008,  Status: Open,  Structure Length: 2.03m (6.66ft),  Average Daily Traffic: 2,000 (year 2020),  Average Future Daily Traffic: 2,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR-224,GUARDSMAN PASS,  Facility Carried by Structure: SUBDVN.ACCESS ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.005,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: D 838,  Location: DEER VALLEY @ FLAGSTAFF (Lat: 40.619689,  Lng: -111.507342),  Route carried "on" structure: State highway 224,  Year Built: 2003,  Status: Open,  Structure Length: 0.99m (3.25ft),  Average Daily Traffic: 4,653 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 5,816 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: DEER VALLEY SKI RUN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.342,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 21.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2C 754,  Location: EAST PARK CITY INTERCHG. (Lat: 40.683492,  Lng: -111.462536),  Route carried "on" structure: US 40,  Year Built: 1989,  Status: Open,  Structure Length: 6.33m (20.77ft),  Average Daily Traffic: 33,813 (year 2020),  Truck Traffic: 27%,  Average Future Daily Traffic: 42,266 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR-248, INTCHG. X-RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.443,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 44.2m (145.0ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 76.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 58.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2F 463,  Location: .4 MI.SE.PARK CITY INTCHG (Lat: 40.677714,  Lng: -111.461228),  Route carried "on" structure: US 40,  Year Built: 1989,  Year Reconstructed: 2015,  Status: Open,  Structure Length: 7.27m (23.85ft),  Average Daily Traffic: 26,188 (year 2020),  Truck Traffic: 22%,  Average Future Daily Traffic: 32,735 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SILVER CREEK AND ABD.R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.095,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 36.0m (118.1ft),  Curb-To-Curb Width: 16.0m (52.5ft),  Out-to-Out Width: 18.6m (61.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 55.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 41.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2F 54,  Location: .7 MI.SE.PARK CITY INTCHG (Lat: 40.673822,  Lng: -111.460600),  Route carried "on" structure: US 40,  Year Built: 1989,  Year Reconstructed: 2015,  Status: Open,  Structure Length: 3.29m (10.79ft),  Average Daily Traffic: 26,188 (year 2020),  Truck Traffic: 22%,  Average Future Daily Traffic: 32,735 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: LOCAL COUNTY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.530,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 32.2m (105.6ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 41.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2V1722,  Location: .8 Mi E of Silver Creek (Lat: 40.707461,  Lng: -111.479225),  Route carried "on" structure: US 40,  Year Built: 2015,  Status: Open,  Structure Length: 0.78m (2.56ft),  Average Daily Traffic: 33,813 (year 2020),  Truck Traffic: 27%,  Average Future Daily Traffic: 42,266 (year 2040),  Design Load: HL 93,  Features Intersected: Ped / Wildlife Trail
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.428,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft)

Condition: Culverts: Satisfactory,  Operating Rating: 49.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: 4C 754,  Location: EAST PARK CITY INTERCHG. (Lat: 40.682931,  Lng: -111.461961),  Route carried "on" structure: US 40,  Year Built: 1989,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 6.33m (20.77ft),  Average Daily Traffic: 33,813 (year 2020),  Truck Traffic: 27%,  Average Future Daily Traffic: 42,266 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR-248, INTCHG. X-RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.155,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 44.2m (145.0ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 77.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 58.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4F 463,  Location: .4 MI.SE.PARK CITY INTCHG (Lat: 40.677250,  Lng: -111.460811),  Route carried "on" structure: US 40,  Year Built: 1989,  Status: Open,  Structure Length: 7.27m (23.85ft),  Average Daily Traffic: 26,188 (year 2020),  Truck Traffic: 22%,  Average Future Daily Traffic: 32,735 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SILVER CREEK & ABD.R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.794,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 36.0m (118.1ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 45.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4F 54,  Location: .7 MI.SE.PARK CITY INTCHG (Lat: 40.673367,  Lng: -111.460183),  Route carried "on" structure: US 40,  Year Built: 1989,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 3.29m (10.79ft),  Average Daily Traffic: 26,188 (year 2020),  Truck Traffic: 22%,  Average Future Daily Traffic: 32,735 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: LOCAL COUNTY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.228,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 32.2m (105.6ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 41.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4V1722,  Location: 1.8 Mi E of Silver Creek (Lat: 40.707275,  Lng: -111.478689),  Route carried "on" structure: US 40,  Year Built: 2015,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 33,813 (year 2020),  Truck Traffic: 27%,  Average Future Daily Traffic: 42,266 (year 2040),  Design Load: HL 93,  Features Intersected: Ped / Wildlife Trail
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.101,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft)

Condition: Culverts: Good,  Operating Rating: 49.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: C 938,  Location: Deer Valley Ski Resort (Lat: 40.621186,  Lng: -111.505286),  Route carried "under" structure: State highway 224,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 4,653 (year 2020),  Truck Traffic: 16%,  Features Intersected: SR-224,  Facility Carried by Structure: DEER VLY. SKI RUN
Minimum Vertical Clearance: 4.92m (16.14ft),  Kilometerpoint: 2.620,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 13.5m (44.3ft)

Find on map >>   Show street view

Structure Number: C 95,  Location: On Guardsman Pass Road (Lat: 40.607892,  Lng: -111.507383),  Route carried "under" structure: State highway 224,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 4,653 (year 2020),  Truck Traffic: 16%,  Features Intersected: SR-224,GUARDSMAN PASS,  Facility Carried by Structure: SUBDVN.ACCESS ROAD
Minimum Vertical Clearance: 5.02m (16.47ft),  Kilometerpoint: 0.644,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.3m (60.0ft)

Find on map >>   Show street view

Structure Number: 2C 754,  Location: EAST PARK CITY INTERCHG. (Lat: 40.683492,  Lng: -111.462536),  Route carried "under" structure: State highway 248,  Year Built: 1989,  Structure Length: 0. m,  Average Daily Traffic: 17,428 (year 2020),  Truck Traffic: 18%,  Features Intersected: SR-248, INTCHG. X-RD,  Facility Carried by Structure: US-40 (SR-40) EBL
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 5.018,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 44.2m (145.0ft)

Find on map >>   Show street view

Structure Number: 2F 54,  Location: .7 MI.SE.PARK CITY INTCHG (Lat: 40.673822,  Lng: -111.460600),  Route carried "under" structure: County highway ,  Year Built: 1989,  Structure Length: 0. m,  Features Intersected: LOCAL COUNTY ROAD,  Facility Carried by Structure: US-40 (SR-40) EBL
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.2m (105.6ft)

Find on map >>   Show street view

Structure Number: 4C 754,  Location: EAST PARK CITY INTERCHG. (Lat: 40.682931,  Lng: -111.461961),  Route carried "under" structure: State highway 248,  Year Built: 1989,  Structure Length: 0. m,  Average Daily Traffic: 10,980 (year 2020),  Truck Traffic: 21%,  Features Intersected: SR-248, INTCHG. X-RD,  Facility Carried by Structure: US-40 (SR-40)WBL
Minimum Vertical Clearance: 5.78m (18.96ft),  Kilometerpoint: 5.036,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 44.2m (145.0ft)

Find on map >>   Show street view

Structure Number: 4F 54,  Location: .7 MI.SE.PARK CITY INTCHG (Lat: 40.673367,  Lng: -111.460183),  Route carried "under" structure: County highway ,  Year Built: 1989,  Structure Length: 0. m,  Average Daily Traffic: 50 (year 2020),  Features Intersected: LOCAL COUNTY ROAD,  Facility Carried by Structure: US-40 (SR-40) WBL
Minimum Vertical Clearance: 4.92m (16.14ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.2m (105.6ft)

Discuss Park City, Utah (UT) on our hugely popular Utah forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.