Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Princeville, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 13Number of bridges
  • 95ft / 29.0mTotal length
  • 66,370Total average daily traffic
  • 7,943Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Princeville
  • No street view available for this location

New bridges in Princeville, NC - historical statistics
  • New bridges - historical statistics
  • 11960-1969
  • 121990-1999
Average Bridge Daily Traffic in Princeville, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 33.3%Good
  • 66.7%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 16.7%Very good
  • 66.7%Good
  • 16.7%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 16.7%Very good
  • 66.7%Good
  • 16.7%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 50.0%Good
  • 50.0%Satisfactory
Find on map >>   Show street view

Structure Number: 650117,  Location: 300'. N. OF JCT. US64 (Lat: 35.862392,  Lng: -77.504422),  Route carried "on" structure: State highway 1523,  Year Built: 1963,  Status: Posted for load,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 210 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 420 (year 2040),  Features Intersected: CROMWELL CANAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.0m (19.7ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.7m (25.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 650325,  Location: 1.2 MI.E. OF JCT.US258 (Lat: 35.870486,  Lng: -77.523658),  Route carried "on" structure: US 64,  Year Built: 1997,  Status: Open,  Structure Length: 4.02m (13.19ft),  Average Daily Traffic: 7,750 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 15,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NC33
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 148.439,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 87.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 650326,  Location: 1.2 MI. E. JCT. US258 (Lat: 35.870753,  Lng: -77.523597),  Route carried "on" structure: US 64,  Year Built: 1997,  Status: Open,  Structure Length: 4.02m (13.19ft),  Average Daily Traffic: 7,750 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 15,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NC33
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 148.439,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 87.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 650327,  Location: 0.9 MI.E.JCT.NC33 (Lat: 35.866131,  Lng: -77.509722),  Route carried "on" structure: US 64,  Year Built: 1997,  Status: Open,  Structure Length: 6.91m (22.67ft),  Average Daily Traffic: 7,750 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 15,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US64ALT&CSXRR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 42.352,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Number Of Approach Spans: 2,  Length of Maximum Span: 21.0m (68.9ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 650328,  Location: 0.9 MI.E.JCT.NC33 (Lat: 35.866314,  Lng: -77.509919),  Route carried "on" structure: US 64,  Year Built: 1997,  Status: Open,  Structure Length: 6.70m (21.98ft),  Average Daily Traffic: 7,750 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 15,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US64ALT & CSXRR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 42.352,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 11.2m (36.7ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 79.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 650329,  Location: 0.6 MI.E.JCT.NC33 (Lat: 35.865714,  Lng: -77.514275),  Route carried "on" structure: US 9901,  Year Built: 1997,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 7,750 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 15,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BR. OF CROMWELL CAN.,  Facility Carried by Structure: US64
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 148.591,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 24.3m (79.7ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.1m (6.9ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: November 2020,  Underwater Inspection Date: November 2020
Find on map >>   Show street view

Structure Number: 65033,  Location: 0.4MI. N. OF JCT US64 ALT (Lat: 35.869336,  Lng: -77.501939),  Route carried "on" structure: State highway 1523,  Year Built: 1998,  Status: Open,  Structure Length: 6.00m (19.69ft),  Average Daily Traffic: 910 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,820 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US64
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 148.744,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.7m (67.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.5m (50.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 87.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 650325,  Location: 1.2 MI.E. OF JCT.US258 (Lat: 35.870486,  Lng: -77.523658),  Route carried "under" structure: State highway 33,  Year Built: 1997,  Structure Length: 0. m,  Average Daily Traffic: 3,800 (year 2019),  Truck Traffic: 7%,  Features Intersected: US64EBL
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 650326,  Location: 1.2 MI. E. JCT. US258 (Lat: 35.870753,  Lng: -77.523597),  Route carried "under" structure: State highway 33,  Year Built: 1997,  Structure Length: 0. m,  Average Daily Traffic: 3,800 (year 2019),  Truck Traffic: 6%,  Features Intersected: US64 WBL
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 650327,  Location: 0.9 MI.E.JCT.NC33 (Lat: 35.866131,  Lng: -77.509722),  Route carried "under" structure: Alternate US 64,  Year Built: 1997,  Structure Length: 0. m,  Average Daily Traffic: 1,700 (year 2019),  Truck Traffic: 12%,  Features Intersected: US64 EBL
Minimum Vertical Clearance: 8.40m (27.56ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.0m (68.9ft)

Find on map >>   Show street view

Structure Number: 650328,  Location: 0.9 MI.E.JCT.NC33 (Lat: 35.866314,  Lng: -77.509919),  Route carried "under" structure: Alternate US 64,  Year Built: 1997,  Structure Length: 0. m,  Average Daily Traffic: 1,700 (year 2017),  Truck Traffic: 12%,  Features Intersected: US64W
Minimum Vertical Clearance: 7.74m (25.39ft),  Kilometerpoint: 42.352,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 65033,  Location: 0.4MI. N. OF JCT US64 ALT (Lat: 35.869336,  Lng: -77.501939),  Route carried "under" structure: US 64,  Year Built: 1998,  Structure Length: 0. m,  Average Daily Traffic: 7,750 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1523
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 148.774,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.7m (67.9ft)

Find on map >>   Show street view

Structure Number: 65033,  Location: 0.4MI. N. OF JCT US64 ALT (Lat: 35.869336,  Lng: -77.501939),  Route carried "under" structure: US 64,  Year Built: 1998,  Structure Length: 0. m,  Average Daily Traffic: 7,750 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1523
Minimum Vertical Clearance: 5.63m (18.47ft),  Kilometerpoint: 148.774,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.7m (67.9ft)