Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Redwater, Texas (TX)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 11Number of bridges
  • 125ft / 37.8mTotal length
  • 31,953Total average daily traffic
  • 4,486Total average daily truck traffic
  • 46,584Total future (year 2033) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Redwater
  • No street view available for this location

New bridges in Redwater, TX - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 41940-1949
  • 41950-1959
  • 11970-1979
  • 11980-1989
Reconstructed bridges in Redwater, TX - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 31950-1959
  • 01960-1969
  • 01970-1979
  • 01980-1989
  • 01990-1999
  • 12000-2009
Average Bridge Daily Traffic in Redwater, TX
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 80.0%Satisfactory
  • 20.0%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 20.0%Good
  • 80.0%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 18.2%Very good
  • 18.2%Good
  • 54.5%Satisfactory
  • 9.1%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 33.3%Good
  • 66.7%Satisfactory
Find on map >>   Show street view

Structure Number: 190190001012093,  Location: 0.81 MI E OF FM 991 W (Lat: 33.370217,  Lng: -94.236919),  Route carried "on" structure: US 67,  Year Built: 1947,  Year Reconstructed: 1956,  Status: Open,  Structure Length: 6.71m (22.01ft),  Average Daily Traffic: 5,538 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 9,040 (year 2033),  Design Load: H 20,  Features Intersected: NETTLES CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.970,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 7,  Number Of Approach Spans: 2,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 190190001012094,  Location: 1.40 MI E OF FM 991 W (Lat: 33.374372,  Lng: -94.227792),  Route carried "on" structure: US 67,  Year Built: 1947,  Year Reconstructed: 1956,  Status: Open,  Structure Length: 5.79m (19.00ft),  Average Daily Traffic: 5,538 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 9,040 (year 2033),  Design Load: H 20,  Features Intersected: ELLIOTT CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 6,  Number Of Approach Spans: 2,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 190190001012104,  Location: 0.60 MI E OF FM 2149 (Lat: 33.348775,  Lng: -94.292722),  Route carried "on" structure: US 67,  Year Built: 1957,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 7.41m (24.31ft),  Average Daily Traffic: 3,219 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 4,610 (year 2033),  Design Load: HS 20,  Features Intersected: CANEY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.711,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 13.3m (43.6ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 190190001013095,  Location: 2.30 MI E OF FM 991 W (Lat: 33.380567,  Lng: -94.214169),  Route carried "on" structure: US 67,  Year Built: 1947,  Year Reconstructed: 1956,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 6,335 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 7,790 (year 2033),  Design Load: H 15,  Features Intersected: BOONE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.062,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: 190190001013149,  Location: 1.80 MI W OF FM 2148 (Lat: 33.387161,  Lng: -94.199661),  Route carried "on" structure: US 67,  Year Built: 1947,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 6,335 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 7,790 (year 2033),  Design Load: H 15,  Features Intersected: FLEMING CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.505,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.1m (6.9ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: 190190001019105,  Location: 0.80 MI N OF US 67 (Lat: 33.374775,  Lng: -94.245922),  Route carried "on" structure: State highway 991,  Year Built: 1959,  Status: Open,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 875 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,660 (year 2033),  Design Load: HS 20,  Features Intersected: NETTLES CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.249,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: 190190001019106,  Location: 0.90 MI N OF US 67 (Lat: 33.376517,  Lng: -94.246058),  Route carried "on" structure: State highway 991,  Year Built: 1959,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 875 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,660 (year 2033),  Design Load: HS 20,  Features Intersected: NETTLES CREEK RELIEF
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.445,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 190190001019107,  Location: 2.20 MI N OF US 67 (Lat: 33.394033,  Lng: -94.239106),  Route carried "on" structure: State highway 991,  Year Built: 1959,  Status: Open,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 875 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,660 (year 2033),  Design Load: HS 20,  Features Intersected: ELLIOTT CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.571,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 190190277602001,  Location: 4.40 MI E OF FM 2149 (Lat: 33.372478,  Lng: -94.293806),  Route carried "on" structure: State highway 3098,  Year Built: 1970,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 1,999 (year 2020),  Truck Traffic: 17%,  Average Future Daily Traffic: 2,970 (year 2033),  Design Load: HS 20,  Features Intersected: E FORK OF CANEY CRK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.091,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: 190190AA0550001,  Location: 0.7 MI W OF FM 991 (Lat: 33.355578,  Lng: -94.265917),  Route carried "on" structure: County highway 1235,  Year Built: 1920,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 45 (year 2013),  Average Future Daily Traffic: 45 (year 2033),  Features Intersected: CONN CREEK,  Facility Carried by Structure: TAYLOR ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.644,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 3.7m (12.1ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 5.2m (17.1ft),  Curb-To-Curb Width: 4.9m (16.1ft),  Out-to-Out Width: 5.7m (18.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 42.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 190190AA0552001,  Location: 2.5 MI S OF RED WATER (Lat: 33.331986,  Lng: -94.250100),  Route carried "on" structure: County highway 1208,  Year Built: 1986,  Status: Open,  Structure Length: 9.81m (32.19ft),  Average Daily Traffic: 319 (year 2013),  Average Future Daily Traffic: 319 (year 2033),  Design Load: HS 20,  Features Intersected: BIG CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.966,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Channel: Very good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2020,  Underwater Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Discuss Redwater, Texas (TX) on our hugely popular Texas forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.