Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Richland Hills, Texas (TX)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 11Number of bridges
  • 157ft / 48.3mTotal length
  • 253,082Total average daily traffic
  • 14,538Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Richland Hills
  • No street view available for this location

New bridges in Richland Hills, TX - historical statistics
  • New bridges - historical statistics
  • 81960-1969
  • 21980-1989
  • 11990-1999
Average Bridge Daily Traffic in Richland Hills, TX
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 33.3%Very good
  • 66.7%Good
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 16.7%Very good
  • 50.0%Good
  • 33.3%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 33.3%Good
  • 66.7%Satisfactory
Find on map >>   Show street view

Structure Number: 22200036301046,  Location: 0.3 MI SW OF SH 26 (Lat: 32.807628,  Lng: -97.248544),  Route carried "on" structure: State highway 183,  Year Built: 1992,  Status: Open,  Structure Length: 7.38m (24.21ft),  Average Daily Traffic: 17,709 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 14,090 (year 2033),  Design Load: HS 20,  Features Intersected: BIG FOSSIL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.610,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 22200036301104,  Location: 0.6 MI SW OF SPUR 474 (Lat: 32.809875,  Lng: -97.245300),  Route carried "on" structure: State highway 26,  Year Built: 1989,  Status: Open,  Structure Length: 9.97m (32.71ft),  Average Daily Traffic: 15,751 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 29,300 (year 2033),  Design Load: HS 20,  Features Intersected: SH 183 WB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.311,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 3,  Length of Maximum Span: 29.0m (95.1ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 22200036303022,  Location: 0.5 MI NE OF MINNIS DR (Lat: 32.794811,  Lng: -97.236461),  Route carried "on" structure: State highway 121,  Year Built: 1967,  Status: Open,  Structure Length: 10.67m (35.01ft),  Average Daily Traffic: 49,062 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 66,450 (year 2033),  Design Load: HS 20,  Features Intersected: FOSSIL CREEK & MIDWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.928,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 16.4m (53.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 22200036303023,  Location: 0.5 MI NE OF MINNIS DR. (Lat: 32.794711,  Lng: -97.236453),  Route carried "on" structure: State highway 121,  Year Built: 1967,  Status: Open,  Structure Length: 10.67m (35.01ft),  Average Daily Traffic: 52,031 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 66,450 (year 2033),  Design Load: HS 20,  Features Intersected: FOSSIL CREEK & MIDWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.928,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 16.4m (53.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 22200036303024,  Location: SH121 HANDLEY EDERVILLE (Lat: 32.801303,  Lng: -97.221108),  Route carried "on" structure: State highway 121,  Year Built: 1967,  Status: Open,  Structure Length: 4.82m (15.81ft),  Average Daily Traffic: 48,155 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 52,620 (year 2033),  Design Load: HS 20,  Features Intersected: HANDLEY EDERVILLE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.367,  Lanes on structure: 3,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 20.7m (67.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 16.4m (53.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 22200036303025,  Location: SH121 HANDLEY EDERVILLE (Lat: 32.801194,  Lng: -97.221108),  Route carried "on" structure: State highway 121,  Year Built: 1967,  Status: Open,  Structure Length: 4.82m (15.81ft),  Average Daily Traffic: 36,464 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 52,620 (year 2033),  Design Load: HS 20,  Features Intersected: HANDLEY EDERVILLE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.367,  Lanes on structure: 3,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 20.7m (67.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 16.2m (53.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 22200036301104,  Location: 0.6 MI SW OF SPUR 474 (Lat: 32.809875,  Lng: -97.245300),  Route carried "under" structure: Alternate State highway 183,  Year Built: 1989,  Structure Length: 0. m,  Average Daily Traffic: 4,520 (year 2013),  Truck Traffic: 7%,  Features Intersected: SH 183 WB,  Facility Carried by Structure: SH 26 NB
Minimum Vertical Clearance: 5.26m (17.26ft),  Kilometerpoint: 0.303,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.0m (95.1ft)

Find on map >>   Show street view

Structure Number: 22200036303022,  Location: 0.5 MI NE OF MINNIS DR (Lat: 32.794811,  Lng: -97.236461),  Route carried "under" structure: City street ,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 2,230 (year 2010),  Features Intersected: FOSSIL CREEK & MIDWAY,  Facility Carried by Structure: SH 121 NBL
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 3.219,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 22200036303023,  Location: 0.5 MI NE OF MINNIS DR. (Lat: 32.794711,  Lng: -97.236453),  Route carried "under" structure: City street ,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 2,230 (year 2010),  Features Intersected: FOSSIL CREEK & MIDWAY,  Facility Carried by Structure: SH 121 SBL
Minimum Vertical Clearance: 4.40m (14.44ft),  Kilometerpoint: 3.219,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 22200036303024,  Location: SH121 HANDLEY EDERVILLE (Lat: 32.801303,  Lng: -97.221108),  Route carried "under" structure: City street ,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 12,465 (year 2016),  Features Intersected: HANDLEY EDERVILLE RD,  Facility Carried by Structure: SH 121 SBL
Minimum Vertical Clearance: 4.32m (14.17ft),  Kilometerpoint: 0.966,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.7m (67.9ft)

Find on map >>   Show street view

Structure Number: 22200036303025,  Location: SH121 HANDLEY EDERVILLE (Lat: 32.801194,  Lng: -97.221108),  Route carried "under" structure: City street ,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 12,465 (year 2016),  Features Intersected: HANDLEY EDERVILLE RD,  Facility Carried by Structure: SH 121 NBL
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 0.966,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.7m (67.9ft)

Discuss Richland Hills, Texas (TX) on our hugely popular Texas forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.