Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Royalston, Massachusetts (MA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 11Number of bridges
  • 49ft / 14.9mTotal length
  • $6,778,000Total costs
  • 4,207Total average daily traffic
  • 421Total average daily truck traffic
  • 6,518Total future (year 2031) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Royalston
  • No street view available for this location

New bridges in Royalston, MA - historical statistics
  • New bridges - historical statistics
  • 31930-1939
  • 31940-1949
  • 12000-2009
  • 42010-2019
Average Bridge Truck Traffic in Royalston, MA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 16.7%Excellent
  • 16.7%Very good
  • 33.3%Good
  • 16.7%Satisfactory
  • 16.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 10.0%Excellent
  • 20.0%Very good
  • 20.0%Good
  • 10.0%Satisfactory
  • 30.0%Fair
  • 10.0%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 10.0%Excellent
  • 30.0%Very good
  • 20.0%Good
  • 10.0%Satisfactory
  • 30.0%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 9.1%Excellent
  • 18.2%Very good
  • 54.5%Good
  • 9.1%Satisfactory
  • 9.1%Fair
Find on map >>   Show street view

Structure Number: R12001B35MUNNBI,  Location: 0.8 M S OF ATHOL RD/RT63 (Lat: 42.665444,  Lng: -72.178861),  Route carried "on" structure: City street ,  Year Built: 2019,  Status: Open,  Structure Length: 1.51m (4.95ft),  Average Daily Traffic: 15 (year 2017),  Design Load: HL 93,  Features Intersected: WATER LAWRENCE BROOK,  Facility Carried by Structure: HWY STOCKWELL RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.285,  Lanes on structure: 1,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 3.9m (12.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 3.9m (12.8ft),  Out-to-Out Width: 4.9m (16.1ft)

Condition: Deck: Excellent,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: R12002164MUNNBI,  Location: 300' N WINCHENDON RD (Lat: 42.671194,  Lng: -72.173075),  Route carried "on" structure: State highway 68,  Year Built: 1940,  Status: Open,  Structure Length: 1.41m (4.63ft),  Average Daily Traffic: 905 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 663 (year 2032),  Design Load: H 20,  Features Intersected: WATER LAWRENCE BROOK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 50.651,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.2m (43.3ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 71.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 1.50m (4.92ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 36 months,  Inspection Date: January 2021,  Underwater Inspection Date: September 2021,  Bridge Improvement Cost: $501,000,  Roadway Improvement Cost: $51,000,  Total Project Cost: $752,000 ( Estimate for 2022),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: R12004B8QMUNNBI,  Location: 1M N OF RT68 NR BROWN RD (Lat: 42.687500,  Lng: -72.177167),  Route carried "on" structure: City street ,  Year Built: 2014,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 600 (year 2016),  Truck Traffic: 6%,  Design Load: HL 93,  Features Intersected: WATER LAWRENCE BROOK,  Facility Carried by Structure: HWY NE FITZWM RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.450,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 8.4m (27.6ft)

Condition: Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: R12006BJWMUNNBI,  Location: 0.6M S OF NH BRDR IN CNTR (Lat: 42.714167,  Lng: -72.181278),  Route carried "on" structure: City street ,  Year Built: 2017,  Status: Open,  Structure Length: 1.49m (4.89ft),  Average Daily Traffic: 110 (year 2004),  Truck Traffic: 6%,  Design Load: HL 93,  Features Intersected: WATER LAWRENCE BROOK,  Facility Carried by Structure: HWY N FITZWLM RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.094,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: R12007165MUNNBI,  Location: .6 MI N OF ATHOL LINE (Lat: 42.649783,  Lng: -72.200567),  Route carried "on" structure: City street ,  Year Built: 1930,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 738 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,958 (year 2031),  Features Intersected: WATER LAWRENCE BROOK,  Facility Carried by Structure: HWY ATHOL RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.853,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Superstructure: Fair,  Substructure: Fair,  Channel: Fair,  Operating Rating: 85.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 0.90m (2.95ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 36 months,  Inspection Date: August 2020,  Underwater Inspection Date: September 2020,  Bridge Improvement Cost: $382,000,  Roadway Improvement Cost: $39,000,  Total Project Cost: $574,000 ( Estimate for 2022)
Find on map >>   Show street view

Structure Number: R12009BT5MUNNBI,  Location: BTOWN LOMIS RD& NH BORDER (Lat: 42.715456,  Lng: -72.178950),  Route carried "on" structure: City street ,  Year Built: 2019,  Status: Open,  Structure Length: 0.80m (2.62ft),  Average Daily Traffic: 187 (year 2015),  Truck Traffic: 6%,  Design Load: HL 93,  Features Intersected: WATER LAWRENCE BROOK,  Facility Carried by Structure: HWY N FITZWLM RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.359,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.0m (26.2ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.8m (28.9ft)

Condition: Superstructure: Excellent,  Substructure: Excellent,  Channel: Excellent,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022
Find on map >>   Show street view

Structure Number: R12013167MUNNBI,  Location: JUST W OF WINCHENDON LINE (Lat: 42.682953,  Lng: -72.115142),  Route carried "on" structure: City street ,  Year Built: 1937,  Status: Open,  Structure Length: 1.02m (3.35ft),  Average Daily Traffic: 1,293 (year 2019),  Truck Traffic: 20%,  Average Future Daily Traffic: 869 (year 2032),  Features Intersected: WATER PRIEST BROOK,  Facility Carried by Structure: HWY WINCHNDON RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.747,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Satisfactory,  Superstructure: Poor,  Substructure: Fair,  Channel: Good,  Operating Rating: 44.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 1.70m (5.58ft),  Designated Inspection Frequency: Every 12 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: January 2021,  Other Special Inspection Date: January 2022,  Bridge Improvement Cost: $1,301,000,  Roadway Improvement Cost: $131,000,  Total Project Cost: $1,952,000 ( Estimate for 2022),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: R12015AU2MUNNBI,  Location: .5 MI N OF PHILLIPSTON LN (Lat: 42.628481,  Lng: -72.144211),  Route carried "on" structure: State highway 68,  Year Built: 2002,  Status: Open,  Structure Length: 3.35m (10.99ft),  Average Daily Traffic: 50 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 2,211 (year 2031),  Design Load: HS 20,  Features Intersected: WATER MILLERS RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 44.814,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 33.0m (108.3ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Inventory Rating: 62.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 3.40m (11.15ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Bridge Improvement Cost: $802,000,  Roadway Improvement Cost: $81,000,  Total Project Cost: $1,204,000 ( Estimate for 2022),  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: R1201817KMUNNBI,  Location: 0.2M S OF NH BDR NR WNCDN (Lat: 42.714917,  Lng: -72.125028),  Route carried "on" structure: City street ,  Year Built: 1938,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 1.67m (5.48ft),  Average Daily Traffic: 51 (year 2013),  Truck Traffic: 6%,  Average Future Daily Traffic: 204 (year 2032),  Design Load: H 15,  Features Intersected: WATER SCOTT BROOK,  Facility Carried by Structure: HWY OLD TNPKE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.814,  Lanes on structure: 1,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.8m (19.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.9m (52.2ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 5.4m (17.7ft),  Out-to-Out Width: 6.1m (20.0ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 35.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: High priority of corrective action,  Length Of Structure Improvement: 2.40m (7.87ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Underwater Inspection Date: December 2021,  Bridge Improvement Cost: $704,000,  Roadway Improvement Cost: $71,000,  Total Project Cost: $1,057,000 ( Estimate for 2022),  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: R12021168MUNNBI,  Location: 1 MI SE OF RTE 32 (Lat: 42.690494,  Lng: -72.224694),  Route carried "on" structure: State highway 68,  Year Built: 1948,  Status: Open,  Structure Length: 0.65m (2.13ft),  Average Daily Traffic: 129 (year 2019),  Average Future Daily Traffic: 409 (year 2032),  Features Intersected: WATER E BR TULLY RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.060,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.5m (21.3ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 0.70m (2.30ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Bridge Improvement Cost: $245,000,  Roadway Improvement Cost: $25,000,  Total Project Cost: $368,000 ( Estimate for 2022)
Find on map >>   Show street view

Structure Number: R1203017QMUNNBI,  Location: 0.2 MI EAST RT 68 (Lat: 42.626711,  Lng: -72.140117),  Route carried "on" structure: City street ,  Year Built: 1941,  Status: Open,  Structure Length: 0.62m (2.03ft),  Average Daily Traffic: 129 (year 2019),  Average Future Daily Traffic: 204 (year 2032),  Features Intersected: WATER BEAVER BROOK,  Facility Carried by Structure: HWY BRCH HL D RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.370,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 1.50m (4.92ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 36 months,  Inspection Date: January 2021,  Underwater Inspection Date: April 2020,  Bridge Improvement Cost: $580,000,  Roadway Improvement Cost: $59,000,  Total Project Cost: $871,000 ( Estimate for 2022)
Discuss Royalston, Massachusetts (MA) on our hugely popular Massachusetts forum.