Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Armada, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 32Number of bridges
  • 128ft / 38.7mTotal length
  • 62,442Total average daily traffic
  • 3,338Total average daily truck traffic
  • 89,194Total future (year 2017) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Armada
  • No street view available for this location

New bridges in Armada, MI - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 21950-1959
  • 61960-1969
  • 51970-1979
  • 41980-1989
  • 61990-1999
  • 42000-2009
  • 42010-2019
Reconstructed bridges in Armada, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 12000-2009
  • 22010-2019
Average Bridge Daily Traffic in Armada, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 6.7%Excellent
  • 6.7%Very good
  • 46.7%Good
  • 6.7%Satisfactory
  • 26.7%Fair
  • 6.7%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 6.3%Excellent
  • 43.8%Very good
  • 12.5%Good
  • 6.3%Satisfactory
  • 6.3%Fair
  • 12.5%Poor
  • 12.5%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 25.0%Very good
  • 56.3%Good
  • 18.8%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 22.6%Very good
  • 22.6%Good
  • 25.8%Satisfactory
  • 19.4%Fair
  • 9.7%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 25.0%Very good
  • 31.3%Good
  • 12.5%Satisfactory
  • 12.5%Fair
  • 6.3%Poor
  • 12.5%Serious
Find on map >>   Show street view

Structure Number: 641,  Location: 3.0 MI N OF PINCONNING (Lat: 43.897033,  Lng: -84.020328),  Route carried "on" structure: Interstate 75,  Year Built: 1968,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 3.26m (10.70ft),  Average Daily Traffic: 13,735 (year 2007),  Truck Traffic: 7%,  Average Future Daily Traffic: 16,605 (year 2030),  Design Load: HS 20+Mod,  Features Intersected: WHITE FEATHER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 43.972,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 76,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 71.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 6228,  Location: 0.9MI WEST OF NORTH AVE (Lat: 42.806017,  Lng: -82.901203),  Route carried "on" structure: County highway 5080,  Year Built: 1968,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 6,300 (year 2009),  Truck Traffic: 3%,  Average Future Daily Traffic: 9,362 (year 2029),  Design Load: H 20,  Features Intersected: COON CREEK,  Facility Carried by Structure: 32 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 16.314,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 81,  Subroute: 4),  Owner: County Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.2m (13.8ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 92.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 623,  Location: 0.3 MI EAST OF OMO RD (Lat: 42.806919,  Lng: -82.852403),  Route carried "on" structure: County highway 5080,  Year Built: 1979,  Status: Posted for load,  Structure Length: 1.98m (6.50ft),  Average Daily Traffic: 5,500 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 6,600 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: HIGHBANK CREEK,  Facility Carried by Structure: 32 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 20.307,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 81,  Subroute: 4),  Owner: County Highway Agency,  Approaching Roadway Width: 12.0m (39.4ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.9m (62.0ft),  Curb-To-Curb Width: 13.0m (42.7ft),  Out-to-Out Width: 13.9m (45.6ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Good,  Channel: Good,  Operating Rating: 50.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 6231,  Location: 0.8 MI EAST OF WOLCOTT RD (Lat: 42.816131,  Lng: -82.927450),  Route carried "on" structure: County highway 5084,  Year Built: 1986,  Status: Open,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 2,556 (year 1997),  Truck Traffic: 3%,  Average Future Daily Traffic: 3,798 (year 2017),  Design Load: HS 25 or greater,  Features Intersected: COON CREEK,  Facility Carried by Structure: ARMADA RIDGE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.357,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.0m (39.4ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 68.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 6232,  Location: 0.1 MI E OF CRYDERMAN RD (Lat: 42.842156,  Lng: -82.834831),  Route carried "on" structure: County highway 5084,  Year Built: 1950,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 1,690 (year 2010),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,511 (year 2030),  Design Load: H 20,  Features Intersected: HIGHBANK CREEK,  Facility Carried by Structure: ARMADA RIDGE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.535,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.3m (10.8ft)

Condition: Channel: Poor,  Culverts: Poor,  Operating Rating: 85.6 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 51.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 6235,  Location: 0.1 MI WEST OF COON CREEK (Lat: 42.849647,  Lng: -82.926450),  Route carried "on" structure: County highway 5090,  Year Built: 1927,  Status: Posted for load,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 3,344 (year 2010),  Truck Traffic: 3%,  Average Future Daily Traffic: 4,504 (year 2030),  Design Load: H 15,  Features Intersected: COON CREEK,  Facility Carried by Structure: ARMADA CENTER RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.044,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 7.0m (23.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 36.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 6236,  Location: 0.2 MI EAST OF NORTH AVE (Lat: 42.850314,  Lng: -82.881378),  Route carried "on" structure: County highway ,  Year Built: 2002,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 1,260 (year 2010),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,065 (year 2030),  Design Load: HS 25 or greater,  Features Intersected: EAST BRANCH COON CREEK,  Facility Carried by Structure: ARMADA CENTER RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.729,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.0m (32.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.1m (10.2ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 16.1m (52.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6268,  Location: 0.3 MI NORTH OF 31 MILE (Lat: 42.794714,  Lng: -82.882967),  Route carried "on" structure: County highway 5063,  Year Built: 1999,  Status: Open,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 7,160 (year 2010),  Truck Traffic: 5%,  Average Future Daily Traffic: 11,735 (year 2030),  Design Load: HS 25 or greater,  Features Intersected: COON CREEK,  Facility Carried by Structure: NORTH AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 18.798,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 13.0m (42.7ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.7m (31.8ft),  Curb-To-Curb Width: 13.0m (42.7ft),  Out-to-Out Width: 13.9m (45.6ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: 627,  Location: 0.5MI N OF ARMADA CENTER (Lat: 42.857133,  Lng: -82.884828),  Route carried "on" structure: County highway 5063,  Year Built: 1964,  Status: Open,  Structure Length: 1.18m (3.87ft),  Average Daily Traffic: 5,930 (year 2010),  Truck Traffic: 3%,  Average Future Daily Traffic: 8,812 (year 2030),  Design Load: H 15,  Features Intersected: E B COON CREEK,  Facility Carried by Structure: NORTH AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 25.762,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.2m (36.7ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 71.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 6287,  Location: 0.2 MI EAST OF NORTH AVE (Lat: 42.821028,  Lng: -82.877936),  Route carried "on" structure: County highway ,  Year Built: 1983,  Status: Posted for load,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 210 (year 2009),  Truck Traffic: 2%,  Average Future Daily Traffic: 312 (year 2029),  Design Load: HS 20,  Features Intersected: EAST BRANCH COON CREEK,  Facility Carried by Structure: 33 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.841,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 7.0m (23.0ft),  Out-to-Out Width: 7.5m (24.6ft)

Condition: Deck: Fair,  Superstructure: Serious,  Substructure: Good,  Channel: Good,  Operating Rating: 40.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 24.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 6289,  Location: 0.2 MI WEST OF COON CREEK (Lat: 42.834922,  Lng: -82.929456),  Route carried "on" structure: County highway ,  Year Built: 1975,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 90 (year 2009),  Truck Traffic: 2%,  Average Future Daily Traffic: 148 (year 2029),  Design Load: H 20,  Features Intersected: COON CREEK,  Facility Carried by Structure: 34 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 14.016,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.0m (26.2ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.9m (12.8ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 79.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: 6292,  Location: 0.1 MI WEST OF NORTH AVE (Lat: 42.864886,  Lng: -82.887042),  Route carried "on" structure: County highway ,  Year Built: 2007,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 300 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 492 (year 2026),  Design Load: HS 20,  Features Intersected: EAST BRANCH COON CREEK,  Facility Carried by Structure: IRWIN ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.381,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.8m (38.7ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6293,  Location: 0.2 MI WEST OF NORTH AVE (Lat: 42.879550,  Lng: -82.885353),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 0.75m (2.46ft),  Average Daily Traffic: 190 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 311 (year 2026),  Design Load: HS 20,  Features Intersected: EAST BRANCH COON CREEK,  Facility Carried by Structure: MCPHALL ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.866,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.0m (39.4ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.5m (24.6ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 55.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 6295,  Location: 0.4 MI WEST OF NORTH AVE (Lat: 42.886797,  Lng: -82.890622),  Route carried "on" structure: County highway ,  Year Built: 1953,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 490 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 803 (year 2026),  Design Load: H 20,  Features Intersected: EAST BRANCH COON CREEK,  Facility Carried by Structure: PRATT ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.313,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.0m (23.0ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021
Find on map >>   Show street view

Structure Number: 6296,  Location: 0.4 MI WEST OF NORTH AVE (Lat: 42.895017,  Lng: -82.892928),  Route carried "on" structure: County highway ,  Year Built: 2014,  Status: Open,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 390 (year 2013),  Truck Traffic: 2%,  Average Future Daily Traffic: 900 (year 2033),  Design Load: Greater than HL93,  Features Intersected: EAST BRANCH COON CREEK,  Facility Carried by Structure: BORDMAN ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.110,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.3m (37.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 6298,  Location: 100 FT N OF ARMADA RIDGE (Lat: 42.816206,  Lng: -82.931808),  Route carried "on" structure: County highway ,  Year Built: 1971,  Status: Posted for load,  Structure Length: 1.03m (3.38ft),  Average Daily Traffic: 210 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 220 (year 2040),  Design Load: H 20,  Features Intersected: COON CREEK,  Facility Carried by Structure: COON CREEK ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.089,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Fair,  Culverts: Serious,  Operating Rating: 11.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 6.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 6336,  Location: 0.05 MI EAST OF OMO ROAD (Lat: 42.792497,  Lng: -82.857475),  Route carried "on" structure: County highway ,  Year Built: 2005,  Status: Open,  Structure Length: 2.68m (8.79ft),  Average Daily Traffic: 180 (year 2009),  Truck Traffic: 2%,  Average Future Daily Traffic: 325 (year 2029),  Design Load: HS 20,  Features Intersected: EAST BRANCH COON CREEK,  Facility Carried by Structure: 31 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 20.325,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.6m (84.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 67.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6338,  Location: 0.3 MI NORTH OF 31 MILE (Lat: 42.793658,  Lng: -82.859658),  Route carried "on" structure: County highway ,  Year Built: 1994,  Status: Open,  Structure Length: 2.68m (8.79ft),  Average Daily Traffic: 280 (year 2009),  Truck Traffic: 2%,  Average Future Daily Traffic: 506 (year 2029),  Design Load: HS 20,  Features Intersected: EAST BRANCH COON CREEK,  Facility Carried by Structure: OMO ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.758,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.3m (83.0ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 72.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6378,  Location: 0.4 MI EAST OF HARTWAY RD (Lat: 42.776297,  Lng: -82.892186),  Route carried "on" structure: County highway ,  Year Built: 1969,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 238 (year 2009),  Truck Traffic: 2%,  Average Future Daily Traffic: 353 (year 2029),  Design Load: H 20,  Features Intersected: TUPPER BROOK DRAIN,  Facility Carried by Structure: 30 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.349,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020
Find on map >>   Show street view

Structure Number: 6379,  Location: 0.1 MI EAST OF NORTH AVE (Lat: 42.776589,  Lng: -82.880142),  Route carried "on" structure: County highway ,  Year Built: 1994,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 180 (year 2009),  Truck Traffic: 3%,  Average Future Daily Traffic: 325 (year 2029),  Design Load: HS 20,  Features Intersected: COON CREEK,  Facility Carried by Structure: 30 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.336,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.0m (39.4ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 6381,  Location: 0.5 MI WEST OF NORTH AVE (Lat: 42.791011,  Lng: -82.891436),  Route carried "on" structure: County highway ,  Year Built: 1964,  Status: Posted for load,  Structure Length: 1.00m (3.28ft),  Average Daily Traffic: 224 (year 2009),  Truck Traffic: 2%,  Average Future Daily Traffic: 333 (year 2029),  Design Load: HS 20,  Features Intersected: TUPPER BROOK DRAIN,  Facility Carried by Structure: 31 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 17.526,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Poor,  Superstructure: Serious,  Substructure: Good,  Channel: Fair,  Operating Rating: 23.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 13.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 6382,  Location: 200 FT EAST OF NORTH AVE (Lat: 42.791269,  Lng: -82.882122),  Route carried "on" structure: County highway ,  Year Built: 1977,  Status: Open,  Structure Length: 1.12m (3.67ft),  Average Daily Traffic: 250 (year 2009),  Truck Traffic: 2%,  Average Future Daily Traffic: 371 (year 2029),  Design Load: H 20,  Features Intersected: COON CREEK,  Facility Carried by Structure: 31 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 18.289,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.6m (11.8ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Channel: Poor,  Culverts: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 97.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 6389,  Location: 0.5 MI EAST OF OMO ROAD (Lat: 42.821900,  Lng: -82.849003),  Route carried "on" structure: County highway ,  Year Built: 2014,  Status: Open,  Structure Length: 0.89m (2.92ft),  Average Daily Traffic: 200 (year 2013),  Truck Traffic: 3%,  Average Future Daily Traffic: 300 (year 2033),  Design Load: HL 93,  Features Intersected: CEMETERY CREEK,  Facility Carried by Structure: 33 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.193,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.3m (27.2ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 82.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 63.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 639,  Location: 0.6 MI EAST OF OMO ROAD (Lat: 42.821936,  Lng: -82.847250),  Route carried "on" structure: County highway ,  Year Built: 2014,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 200 (year 2013),  Truck Traffic: 3%,  Average Future Daily Traffic: 300 (year 2033),  Design Load: HL 93,  Features Intersected: HIGHBANK CREEK,  Facility Carried by Structure: 33 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.336,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 82.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 63.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 6391,  Location: AT OMO ROAD INTERSECTION (Lat: 42.836397,  Lng: -82.863378),  Route carried "on" structure: County highway ,  Year Built: 2010,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 110 (year 2009),  Truck Traffic: 2%,  Average Future Daily Traffic: 148 (year 2029),  Design Load: HS 20,  Features Intersected: CEMETERY CREEK,  Facility Carried by Structure: 34 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.060,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 54.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 42.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 6392,  Location: 0.9 MI EAST OF OMO ROAD (Lat: 42.837000,  Lng: -82.839167),  Route carried "on" structure: County highway ,  Year Built: 1997,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 100 (year 2009),  Truck Traffic: 2%,  Average Future Daily Traffic: 135 (year 2029),  Design Load: HS 20,  Features Intersected: HIGHBANK CREEK,  Facility Carried by Structure: 34 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.090,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 55.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 33.2 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Wearing Surface/Protective System: Wearing Surface: Gravel,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 641,  Location: SEC 23 ARMADA TWP (Lat: 42.843775,  Lng: -82.886886),  Route carried "on" structure: City street ,  Year Built: 1990,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 2,230 (year 2006),  Truck Traffic: 10%,  Average Future Daily Traffic: 4,030 (year 2026),  Design Load: HS 20,  Features Intersected: E BR COON CREEK,  Facility Carried by Structure: WEST MAIN STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.077,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.0m (32.8ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Inventory Rating: 67.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6411,  Location: 0.25 MI S OF ARMADACENTER (Lat: 42.848403,  Lng: -82.884808),  Route carried "on" structure: City street 54,  Year Built: 1995,  Status: Open,  Structure Length: 1.60m (5.25ft),  Average Daily Traffic: 6,200 (year 2009),  Truck Traffic: 10%,  Average Future Daily Traffic: 9,200 (year 2029),  Design Load: HS 20,  Features Intersected: E BR COON CREEK,  Facility Carried by Structure: NORTH FULTON ST
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 24.790,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.0m (52.5ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 91.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 54.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6412,  Location: SEC 23 ARMADA TWP (Lat: 42.845817,  Lng: -82.884892),  Route carried "on" structure: City street ,  Year Built: 1982,  Year Reconstructed: 2015,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 315 (year 2014),  Average Future Daily Traffic: 385 (year 2034),  Design Load: Greater than HL93,  Features Intersected: EAST BR OF COON CREEK,  Facility Carried by Structure: PROSPECT STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.309,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.3m (33.8ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 0.0m,  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 63.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6413,  Location: SEC 23 ARMADA TWP (Lat: 42.848861,  Lng: -82.883522),  Route carried "on" structure: Alternate City street ,  Year Built: 1982,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 400 (year 2009),  Average Future Daily Traffic: 400 (year 2029),  Design Load: HS 20,  Features Intersected: EAST BR OF COON CREEK,  Facility Carried by Structure: BURK STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.286,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.0m (29.5ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Very good,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10057,  Location: SEC 26-35 BERLIN TWP (Lat: 42.909808,  Lng: -82.895289),  Route carried "on" structure: County highway 7758,  Year Built: 1973,  Year Reconstructed: 2017,  Status: Open,  Structure Length: 0.69m (2.26ft),  Average Daily Traffic: 1,880 (year 2015),  Truck Traffic: 16%,  Average Future Daily Traffic: 2,790 (year 2035),  Design Load: HS 20,  Features Intersected: GRAHAM DRAIN,  Facility Carried by Structure: HOUGH ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.675,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.2m (20.3ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 70.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 57.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 14319,  Location: 1200' E OF ARMADA RIDGE (Lat: 42.837300,  Lng: -82.823500),  Route carried "on" structure: County highway ,  Year Built: 1968,  Status: Posted for load,  Structure Length: 0.74m (2.43ft),  Average Daily Traffic: 100 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 115 (year 2035),  Design Load: HS 20,  Features Intersected: HIGHBANK CREEK,  Facility Carried by Structure: 34 MILE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.713,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Channel: Poor,  Culverts: Serious,  Operating Rating: 17.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 10.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: July 2021,  Wearing Surface/Protective System: Wearing Surface: Gravel
Discuss Armada, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.