Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Auburn, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 17Number of bridges
  • 128ft / 38.6mTotal length
  • $731,000Total costs
  • 153,070Total average daily traffic
  • 9,560Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Auburn
  • No street view available for this location

New bridges in Auburn, MI - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 61950-1959
  • 11960-1969
  • 11970-1979
  • 31980-1989
  • 32000-2009
  • 22010-2019
Average Bridge Daily Traffic in Auburn, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 9.1%Very good
  • 9.1%Good
  • 36.4%Satisfactory
  • 36.4%Fair
  • 9.1%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 9.1%Very good
  • 18.2%Good
  • 36.4%Satisfactory
  • 36.4%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 9.1%Very good
  • 18.2%Good
  • 27.3%Satisfactory
  • 36.4%Fair
  • 9.1%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 11.1%Very good
  • 22.2%Good
  • 44.4%Satisfactory
  • 22.2%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Very good
  • 50.0%Good
Find on map >>   Show street view

Structure Number: 664,  Location: 2.0 MI W OF AUBURN (Lat: 43.597322,  Lng: -84.109097),  Route carried "on" structure: County highway ,  Year Built: 1958,  Status: Open,  Structure Length: 6.03m (19.78ft),  Average Daily Traffic: 895 (year 1995),  Truck Traffic: 3%,  Average Future Daily Traffic: 430 (year 1977),  Design Load: H 15,  Features Intersected: US-10,  Facility Carried by Structure: ELEVEN MILE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.232,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 17.9m (58.7ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 6.04m (19.82ft),  Designated Inspection Frequency: Every 22 months,  Inspection Date: June 2020,  Bridge Improvement Cost: $70,000,  Roadway Improvement Cost: $7,000,  Total Project Cost: $82,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 665,  Location: 1.0 MI W OF AUBURN (Lat: 43.597067,  Lng: -84.089608),  Route carried "on" structure: County highway 917,  Year Built: 1958,  Status: Open,  Structure Length: 6.03m (19.78ft),  Average Daily Traffic: 2,030 (year 1983),  Average Future Daily Traffic: 2,030 (year 1977),  Design Load: H 15,  Features Intersected: US-10,  Facility Carried by Structure: GARFIELD RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.248,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.8m (38.7ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 17.9m (58.7ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 51.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 6.04m (19.82ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Bridge Improvement Cost: $70,000,  Roadway Improvement Cost: $13,000,  Total Project Cost: $151,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 667,  Location: 6.0 MI W OF BAY CITY (Lat: 43.596656,  Lng: -84.031933),  Route carried "on" structure: County highway 929,  Year Built: 1958,  Status: Open,  Structure Length: 5.57m (18.27ft),  Average Daily Traffic: 1,869 (year 1997),  Truck Traffic: 3%,  Average Future Daily Traffic: 580 (year 1977),  Design Load: H 15,  Features Intersected: US-10,  Facility Carried by Structure: SEVEN MILE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.065,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 16.4m (53.8ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 49.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 5.58m (18.31ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $66,000,  Roadway Improvement Cost: $7,000,  Total Project Cost: $78,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 674,  Location: 600 FT W OF FRASER RD (Lat: 43.603219,  Lng: -84.014522),  Route carried "on" structure: County highway 926,  Year Built: 2016,  Status: Open,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 3,957 (year 2014),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,880 (year 2034),  Design Load: Greater than HL93,  Features Intersected: CULVER CREEK,  Facility Carried by Structure: MIDLAND ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 12.355,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 76,  Subroute: 2),  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 69.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 53.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 682,  Location: 1,600 FT E OF GARFIELD RD (Lat: 43.668147,  Lng: -84.081831),  Route carried "on" structure: County highway 938,  Year Built: 1987,  Status: Posted for load,  Structure Length: 1.43m (4.69ft),  Average Daily Traffic: 2,870 (year 2000),  Truck Traffic: 10%,  Average Future Daily Traffic: 4,592 (year 2020),  Design Load: HS 20+Mod,  Features Intersected: KAWKAWLIN RIVER,  Facility Carried by Structure: BEAVER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.875,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 712,  Location: 700 FT W OF EIGHT MILE RD (Lat: 43.581678,  Lng: -84.052225),  Route carried "on" structure: County highway 922,  Year Built: 1987,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 2,264 (year 2000),  Truck Traffic: 7%,  Average Future Daily Traffic: 3,625 (year 2020),  Design Load: HS 20,  Features Intersected: CULVER CREEK,  Facility Carried by Structure: SALZBURG ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 9.346,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 19.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 717,  Location: 1000 FEET E OF 9 MI RD (Lat: 43.653564,  Lng: -84.064500),  Route carried "on" structure: County highway ,  Year Built: 1970,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 66 (year 2000),  Truck Traffic: 5%,  Average Future Daily Traffic: 80 (year 2020),  Design Load: HS 20+Mod,  Features Intersected: KAWKAWLIN RIVER,  Facility Carried by Structure: TOWNLINE 14 ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.276,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.7m (18.7ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.1m (39.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Poor,  Operating Rating: 42.4 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 737,  Location: 0.5 MI E OF FRASER RD (Lat: 43.610269,  Lng: -84.003189),  Route carried "on" structure: County highway ,  Year Built: 2005,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 390 (year 2004),  Truck Traffic: 2%,  Average Future Daily Traffic: 630 (year 2024),  Design Load: HS 20+Mod,  Features Intersected: CULVER CREEK,  Facility Carried by Structure: NORTH UNION ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.295,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 16.4m (53.8ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 738,  Location: 0.6 MI N OF N UNION RD (Lat: 43.618414,  Lng: -84.011464),  Route carried "on" structure: County highway ,  Year Built: 1986,  Status: Posted for load,  Structure Length: 3.78m (12.40ft),  Average Daily Traffic: 366 (year 2000),  Truck Traffic: 7%,  Average Future Daily Traffic: 439 (year 2020),  Design Load: HS 20+Mod,  Features Intersected: KAWKAWLIN RIVER,  Facility Carried by Structure: FRASER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.400,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.5m (41.0ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 745,  Location: 200 FT E OF NINE MILE RD (Lat: 43.646783,  Lng: -84.068931),  Route carried "on" structure: County highway ,  Year Built: 2004,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 186 (year 2004),  Truck Traffic: 10%,  Average Future Daily Traffic: 230 (year 2024),  Design Load: HS 20+Mod,  Features Intersected: KAWKAWLIN RIVER,  Facility Carried by Structure: CHIP ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.053,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.0m (45.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 95.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 57.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 746,  Location: 0.5 MI S OF WHEELER RD (Lat: 43.631886,  Lng: -84.049097),  Route carried "on" structure: County highway ,  Year Built: 1934,  Status: Posted for load,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 380 (year 2000),  Truck Traffic: 10%,  Average Future Daily Traffic: 456 (year 2020),  Design Load: H 20,  Features Intersected: KAWKAWLIN RIVER,  Facility Carried by Structure: EIGHT MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.742,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.5m (37.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Poor,  Channel: Poor,  Operating Rating: 24.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 14.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 1.95m (6.40ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $328,000,  Roadway Improvement Cost: $70,000,  Total Project Cost: $420,000,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 6911,  Location: 1.3 MI NW OF M-30 (Lat: 43.688400,  Lng: -84.393500),  Route carried "on" structure: County highway 5651,  Year Built: 1962,  Year Reconstructed: 2013,  Status: Open,  Structure Length: 6.78m (22.24ft),  Average Daily Traffic: 6,862 (year 1996),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,700 (year 2015),  Design Load: HS 20+Mod,  Features Intersected: US-10,  Facility Carried by Structure: W RIVER RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.355,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 22.9m (75.1ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6931,  Location: 0.5 MI E OF MERIDIAN RD (Lat: 43.525297,  Lng: -84.360081),  Route carried "on" structure: County highway ,  Year Built: 2003,  Status: Open,  Structure Length: 1.68m (5.51ft),  Average Daily Traffic: 2,077 (year 2002),  Truck Traffic: 3%,  Average Future Daily Traffic: 3,053 (year 2022),  Design Load: HS 20,  Features Intersected: BULLOCK CREEK,  Facility Carried by Structure: FREELAND ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.785,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 53.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 664,  Location: 2.0 MI W OF AUBURN (Lat: 43.597322,  Lng: -84.109097),  Route carried "under" structure: US 10,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 29,780 (year 2007),  Truck Traffic: 7%,  Features Intersected: US-10,  Facility Carried by Structure: ELEVEN MILE RD
Minimum Vertical Clearance: 4.80m (15.75ft),  Kilometerpoint: 5.501,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 17.9m (58.7ft)

Find on map >>   Show street view

Structure Number: 665,  Location: 1.0 MI W OF AUBURN (Lat: 43.597067,  Lng: -84.089608),  Route carried "under" structure: US 10,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 31,204 (year 2007),  Truck Traffic: 7%,  Features Intersected: US-10,  Facility Carried by Structure: GARFIELD RD
Minimum Vertical Clearance: 4.75m (15.58ft),  Kilometerpoint: 7.075,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 17.9m (58.7ft)

Find on map >>   Show street view

Structure Number: 666,  Location: S LTS OF AUBURN (Lat: 43.596772,  Lng: -84.069453),  Route carried "under" structure: US 10,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 34,400 (year 2014),  Truck Traffic: 6%,  Features Intersected: US-10,  Facility Carried by Structure: NINE MILE RD
Minimum Vertical Clearance: 4.75m (15.58ft),  Kilometerpoint: 8.702,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.5m (83.7ft)

Find on map >>   Show street view

Structure Number: 667,  Location: 6.0 MI W OF BAY CITY (Lat: 43.596656,  Lng: -84.031933),  Route carried "under" structure: US 10,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 33,474 (year 2007),  Truck Traffic: 6%,  Features Intersected: US-10,  Facility Carried by Structure: SEVEN MILE RD
Minimum Vertical Clearance: 4.82m (15.81ft),  Kilometerpoint: 11.731,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 16.4m (53.8ft)

Discuss Auburn, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.