Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Bylas, Arizona (AZ)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 16Number of bridges
  • 105ft / 31.5mTotal length
  • $16,000Total costs
  • 85,544Total average daily traffic
  • 16,221Total average daily truck traffic
  • 88,045Total future (year 2037) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Bylas
  • No street view available for this location

New bridges in Bylas, AZ - historical statistics
  • New bridges - historical statistics
  • 21930-1939
  • 111950-1959
  • 31960-1969
Reconstructed bridges in Bylas, AZ - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21950-1959
  • 01960-1969
  • 01970-1979
  • 01980-1989
  • 51990-1999
  • 12000-2009
Average Bridge Daily Traffic in Bylas, AZ
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 50.0%Good
  • 25.0%Satisfactory
  • 25.0%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 50.0%Good
  • 43.8%Satisfactory
  • 6.3%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 75.0%Good
  • 25.0%Satisfactory
Find on map >>   Show street view

Structure Number: 513,  Location: 28.5 mi E Jct SR 170 (Lat: 33.090867,  Lng: -110.065325),  Route carried "on" structure: US 70,  Year Built: 1932,  Year Reconstructed: 1961,  Status: Open,  Structure Length: 3.41m (11.19ft),  Average Daily Traffic: 2,772 (year 2018),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,782 (year 2038),  Design Load: H 15,  Features Intersected: Dry Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 482.015,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 6.7m (22.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 42.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.31m (14.14ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Total Project Cost: $1,000 ( Estimate for 2019),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 545,  Location: 32.7 mi W Jct US 191 (Lat: 33.034933,  Lng: -109.960939),  Route carried "on" structure: US 70,  Year Built: 1932,  Year Reconstructed: 1959,  Status: Open,  Structure Length: 6.31m (20.70ft),  Average Daily Traffic: 3,319 (year 2018),  Truck Traffic: 10%,  Average Future Daily Traffic: 3,329 (year 2038),  Design Load: H 15,  Features Intersected: Black Rock Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 493.682,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Fair,  Operating Rating: 48.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 7.35m (24.11ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $1,000,  Total Project Cost: $2,000 ( Estimate for 2019),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 698,  Location: 10.3 mi S Jct I-10 (Lat: 31.816800,  Lng: -110.347500),  Route carried "on" structure: State highway 90,  Year Built: 1962,  Status: Open,  Structure Length: 4.02m (13.19ft),  Average Daily Traffic: 5,086 (year 2019),  Truck Traffic: 13%,  Average Future Daily Traffic: 7,437 (year 2039),  Design Load: HS 20,  Features Intersected: Middle Canyon Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 482.578,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 42.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 703,  Location: 14.3 mi W Jct SR 71 (Lat: 33.874700,  Lng: -113.380500),  Route carried "on" structure: US 60,  Year Built: 1962,  Status: Open,  Structure Length: 2.47m (8.10ft),  Average Daily Traffic: 1,652 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 1,662 (year 2038),  Design Load: HS 20,  Features Intersected: Dry Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 115.116,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4295,  Location: 19.7 mi E SR 170 (Lat: 33.183611,  Lng: -110.157444),  Route carried "on" structure: US 70,  Year Built: 1956,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 2,772 (year 2018),  Truck Traffic: 22%,  Average Future Daily Traffic: 2,782 (year 2039),  Design Load: HS 20,  Features Intersected: Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 468.013,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft),  Out-to-Out Width: 15.5m (50.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 71.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.10m (6.89ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2019,  Total Project Cost: $1,000 ( Estimate for 2019)
Find on map >>   Show street view

Structure Number: 4296,  Location: 20.3 mi E SR 170 (Lat: 33.178889,  Lng: -110.148833),  Route carried "on" structure: US 70,  Year Built: 1956,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 2,772 (year 2018),  Truck Traffic: 22%,  Average Future Daily Traffic: 2,782 (year 2039),  Design Load: HS 20,  Features Intersected: Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 468.947,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.07m (6.79ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2019,  Total Project Cost: $1,000 ( Estimate for 2019),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4297,  Location: 20.9 mi E SR 170 (Lat: 33.173917,  Lng: -110.140417),  Route carried "on" structure: US 70,  Year Built: 1956,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 2,772 (year 2018),  Truck Traffic: 22%,  Average Future Daily Traffic: 2,782 (year 2039),  Design Load: HS 20,  Features Intersected: Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 469.928,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.10m (6.89ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2019,  Total Project Cost: $1,000 ( Estimate for 2019),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4298,  Location: 23.5 mi E SR 170 (Lat: 33.138917,  Lng: -110.124889),  Route carried "on" structure: US 70,  Year Built: 1957,  Status: Open,  Structure Length: 1.98m (6.50ft),  Average Daily Traffic: 2,772 (year 2018),  Truck Traffic: 22%,  Average Future Daily Traffic: 2,782 (year 2039),  Design Load: HS 20,  Features Intersected: Bates Draw
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 474.113,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.7m (41.7ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.77m (9.09ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2019,  Total Project Cost: $1,000 ( Estimate for 2019),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4299,  Location: 24.1 mi E SR 170 (Lat: 33.131667,  Lng: -110.119778),  Route carried "on" structure: US 70,  Year Built: 1958,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 2,772 (year 2018),  Truck Traffic: 22%,  Average Future Daily Traffic: 2,782 (year 2039),  Design Load: HS 20,  Features Intersected: Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 475.062,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.74m (5.71ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2019,  Total Project Cost: $1,000 ( Estimate for 2019)
Find on map >>   Show street view

Structure Number: 43,  Location: 24.9 mi E SR 170 (Lat: 33.121833,  Lng: -110.111944),  Route carried "on" structure: US 70,  Year Built: 1958,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 2,772 (year 2018),  Truck Traffic: 22%,  Average Future Daily Traffic: 2,782 (year 2039),  Design Load: HS 20,  Features Intersected: Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 476.398,  Lanes on structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.10m (6.89ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2019,  Total Project Cost: $1,000 ( Estimate for 2019)
Find on map >>   Show street view

Structure Number: 4301,  Location: 25.3 mi E SR 170 (Lat: 33.117528,  Lng: -110.107861),  Route carried "on" structure: US 70,  Year Built: 1958,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 2.41m (7.91ft),  Average Daily Traffic: 2,772 (year 2018),  Truck Traffic: 22%,  Average Future Daily Traffic: 2,782 (year 2039),  Design Load: HS 20,  Features Intersected: Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 476.961,  Lanes on structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.20m (10.50ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2019,  Total Project Cost: $1,000 ( Estimate for 2019)
Find on map >>   Show street view

Structure Number: 4302,  Location: 25.8 mi E SR 170 (Lat: 33.113583,  Lng: -110.100056),  Route carried "on" structure: US 70,  Year Built: 1958,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 2,772 (year 2018),  Truck Traffic: 22%,  Average Future Daily Traffic: 2,782 (year 2039),  Design Load: HS 20,  Features Intersected: Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 477.830,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.07m (6.79ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2019,  Total Project Cost: $1,000 ( Estimate for 2019),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4303,  Location: 26.2 mi E SR 170 (Lat: 33.111000,  Lng: -110.094000),  Route carried "on" structure: US 70,  Year Built: 1957,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 2,772 (year 2018),  Truck Traffic: 22%,  Average Future Daily Traffic: 2,782 (year 2039),  Design Load: HS 20,  Features Intersected: Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 478.474,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.46m (4.79ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2019,  Total Project Cost: $1,000 ( Estimate for 2019),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4304,  Location: 26.5 mi E SR 170 (Lat: 33.109194,  Lng: -110.090028),  Route carried "on" structure: US 70,  Year Built: 1958,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 2,772 (year 2018),  Truck Traffic: 22%,  Average Future Daily Traffic: 2,782 (year 2039),  Design Load: HS 20,  Features Intersected: Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 478.892,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 81.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.07m (6.79ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2019,  Total Project Cost: $1,000 ( Estimate for 2019)
Find on map >>   Show street view

Structure Number: 4305,  Location: 27.5 mi E SR 170 (Lat: 33.098111,  Lng: -110.077083),  Route carried "on" structure: US 70,  Year Built: 1957,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 2,772 (year 2018),  Truck Traffic: 22%,  Average Future Daily Traffic: 2,782 (year 2039),  Design Load: HS 20,  Features Intersected: Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 480.614,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 12.7m (41.7ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.37m (4.49ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2019,  Total Project Cost: $1,000 ( Estimate for 2019),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5452,  Location: 2.4 mi South Jct SR 187 (Lat: 32.973917,  Lng: -111.729556),  Route carried "on" structure: Interstate 10,  Year Built: 1967,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 42,223 (year 2017),  Truck Traffic: 19%,  Average Future Daily Traffic: 42,233 (year 2037),  Design Load: HS 20,  Features Intersected: Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 302.026,  Lanes on structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 30.5m (100.1ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.37m (4.49ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2019,  Bridge Improvement Cost: $1,000,  Total Project Cost: $2,000