Bridge Statistics for Centerville, Utah (UT)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 13Number of bridges
  • 121ft / 37.2mTotal length
  • 534,622Total average daily traffic
  • 104,774Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Centerville
  • No street view available for this location

New bridges in Centerville, UT - historical statistics
  • New bridges - historical statistics
  • 31970-1979
  • 82000-2009
  • 22010-2019
Average Bridge Daily Traffic in Centerville, UT
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 16.7%Good
  • 66.7%Satisfactory
  • 16.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 33.3%Very good
  • 50.0%Good
  • 16.7%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 16.7%Very good
  • 16.7%Good
  • 66.7%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Good
  • 50.0%Fair
Find on map >>   Show street view

Structure Number: C 578,  Location: W.of PARRISH LN.INT.-CNVL (Lat: 40.921522,  Lng: -111.892342),  Route carried "on" structure: State highway 105,  Year Built: 1970,  Year Reconstructed: 2008,  Status: Open,  Structure Length: 3.99m (13.09ft),  Average Daily Traffic: 5,560 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 6,950 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: UPRR and UTA TRACKS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.681,  Lanes on structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 23.4m (76.8ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.2m (53.1ft),  Curb-To-Curb Width: 23.4m (76.8ft),  Out-to-Out Width: 24.4m (80.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 34.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 30.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: C 596,  Location: PARRISH LN.INT.-CNTRVIL. (Lat: 40.921522,  Lng: -111.891478),  Route carried "on" structure: State highway 105,  Year Built: 1974,  Year Reconstructed: 2007,  Status: Open,  Structure Length: 7.41m (24.31ft),  Average Daily Traffic: 5,560 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 6,950 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I-15 (SR-15) NBL AND SBL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.754,  Lanes on structure: 5,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 38.3m (125.7ft),  Curb-To-Curb Width: 21.9m (71.9ft),  Out-to-Out Width: 22.8m (74.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 38.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 28.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: C1029,  Location: Parrish Ln. Trail (Lat: 40.921653,  Lng: -111.890822),  Route carried "on" structure: 15,  Year Built: 2015,  Structure Length: 7.44m (24.41ft),  Average Daily Traffic: 137,164 (year 2020),  Truck Traffic: 20%,  Average Future Daily Traffic: 171,455 (year 2040),  Design Load: Pedestrian,  Features Intersected: I-15,  Facility Carried by Structure: Parrish Ln Ped
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 514.728,  Lanes under structure: 10,  Owner: State Highway Agency,  Approaching Roadway Width: 3.0m (9.8ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 38.4m (126.0ft),  Curb-To-Curb Width: 3.0m (9.8ft),  Out-to-Out Width: 3.7m (12.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E2554,  Location: 1000 No.1250W.Centerville (Lat: 40.929167,  Lng: -111.896944),  Route carried "on" structure: State highway 67,  Year Built: 2008,  Status: Open,  Structure Length: 1.02m (3.35ft),  Average Daily Traffic: 22,775 (year 2020),  Truck Traffic: 23%,  Average Future Daily Traffic: 28,469 (year 2040),  Design Load: HL 93,  Features Intersected: 1000NO.DRAINAGE CHANNEL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.704,  Lanes on structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 30.9m (101.4ft),  Skew: 14 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.6m (15.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: June 2021,  Underwater Inspection Date: July 2019
Find on map >>   Show street view

Structure Number: E2573,  Location: 2500 No. 850W. W. Bntfl. (Lat: 40.918072,  Lng: -111.901769),  Route carried "on" structure: State highway 67,  Year Built: 2008,  Status: Open,  Structure Length: 1.94m (6.36ft),  Average Daily Traffic: 20,610 (year 2020),  Truck Traffic: 21%,  Average Future Daily Traffic: 25,763 (year 2040),  Design Load: HL 93,  Features Intersected: LEGACY PARKWAY TRAIL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.492,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 20.0m (65.6ft),  Skew: 26 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.8m (58.4ft)

Condition: Culverts: Fair,  Operating Rating: 57.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 48.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: F 719,  Location: 1100No.1250W.Centerville (Lat: 40.930381,  Lng: -111.894906),  Route carried "on" structure: City street 1431,  Year Built: 2008,  Status: Open,  Structure Length: 8.50m (27.89ft),  Average Daily Traffic: 909 (year 2020),  Average Future Daily Traffic: 1,136 (year 2040),  Design Load: HL 93,  Features Intersected: SR-67,LEGACY PARKWAY,  Facility Carried by Structure: 1250 WEST STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.711,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 5 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 41.1m (134.8ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 0.0m,  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 16.5m (54.1ft)

Condition: Deck: Fair,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 24.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1F 667,  Location: 1400 W.400 N.,Centerville (Lat: 40.921236,  Lng: -111.899869),  Route carried "on" structure: State highway 67,  Year Built: 2008,  Status: Open,  Structure Length: 3.45m (11.32ft),  Average Daily Traffic: 22,775 (year 2020),  Truck Traffic: 23%,  Average Future Daily Traffic: 28,469 (year 2040),  Design Load: HL 93,  Features Intersected: SR-105, PARRISH LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.883,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 19.4m (63.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 41.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3F 667,  Location: 1400 W.400 No.Centerville (Lat: 40.921831,  Lng: -111.900053),  Route carried "on" structure: State highway 67,  Year Built: 2008,  Status: Open,  Structure Length: 3.45m (11.32ft),  Average Daily Traffic: 20,610 (year 2020),  Truck Traffic: 21%,  Average Future Daily Traffic: 25,763 (year 2040),  Design Load: HL 93,  Features Intersected: SR105, PARRISH LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.567,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 19.4m (63.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 41.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: C 596,  Location: PARRISH LN.INT.-CNTRVIL. (Lat: 40.921522,  Lng: -111.891478),  Route carried "under" structure: Interstate 15,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 132,382 (year 2020),  Truck Traffic: 19%,  Features Intersected: I-15 (SR-15) NBL AND SBL,  Facility Carried by Structure: SR-105,-INT.X-RD.
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 514.203,  Lanes on structure: 5,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.3m (125.7ft)

Find on map >>   Show street view

Structure Number: C1029,  Location: Parrish Ln. Trail (Lat: 40.921653,  Lng: -111.890822),  Route carried "under" structure: Interstate 15,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 132,382 (year 2020),  Truck Traffic: 19%,  Features Intersected: I-15,  Facility Carried by Structure: Parrish Ln Ped
Minimum Vertical Clearance: 6.37m (20.90ft),  Kilometerpoint: 514.234,  Lanes under structure: 10,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.4m (126.0ft)

Find on map >>   Show street view

Structure Number: F 719,  Location: 1100No.1250W.Centerville (Lat: 40.930381,  Lng: -111.894906),  Route carried "under" structure: State highway 67,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 22,775 (year 2020),  Truck Traffic: 23%,  Features Intersected: SR-67,LEGACY PARKWAY,  Facility Carried by Structure: 1250 WEST STREET
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 12.938,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.1m (134.8ft)

Find on map >>   Show street view

Structure Number: 1F 667,  Location: 1400 W.400 N.,Centerville (Lat: 40.921236,  Lng: -111.899869),  Route carried "under" structure: State highway 105,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 5,560 (year 2020),  Truck Traffic: 12%,  Features Intersected: SR-105, PARRISH LANE,  Facility Carried by Structure: SR67NB,LEGACY PKWY
Minimum Vertical Clearance: 5.26m (17.26ft),  Kilometerpoint: 0.048,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>   Show street view

Structure Number: 3F 667,  Location: 1400 W.400 No.Centerville (Lat: 40.921831,  Lng: -111.900053),  Route carried "under" structure: State highway 105,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 5,560 (year 2020),  Truck Traffic: 12%,  Features Intersected: SR105, PARRISH LANE,  Facility Carried by Structure: SR67SB,LEGACY PKWY
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 0.029,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Discuss Centerville, Utah (UT) on our hugely popular Utah forum.