Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Citrus Ridge, Florida (FL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 32Number of bridges
  • 436ft / 133mTotal length
  • $609,000Total costs
  • 1,061,300Total average daily traffic
  • 123,172Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Citrus Ridge
  • No street view available for this location

New bridges in Citrus Ridge, FL - historical statistics
  • New bridges - historical statistics
  • 71960-1969
  • 51970-1979
  • 202000-2009
Reconstructed bridges in Citrus Ridge, FL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21990-1999
  • 42000-2009
  • 22010-2019
Average Bridge Daily Traffic in Citrus Ridge, FL
Average Bridge Truck Traffic in Citrus Ridge, FL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 15.4%Very good
  • 69.2%Good
  • 15.4%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 15.4%Very good
  • 61.5%Good
  • 15.4%Satisfactory
  • 7.7%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 25.0%Good
  • 50.0%Satisfactory
  • 25.0%Fair
Find on map >>   Show street view

Structure Number: 110036,  Location: US-27 NB over US-192 (Lat: 28.346997,  Lng: -81.673558),  Route carried "on" structure: US 27,  Year Built: 1971,  Year Reconstructed: 2014,  Status: Open,  Structure Length: 5.55m (18.21ft),  Average Daily Traffic: 21,250 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 36,869 (year 2042),  Design Load: HL 93,  Features Intersected: US-192
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.4m (89.9ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 38.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 11094,  Location: US-27 SB over US-192 (Lat: 28.346994,  Lng: -81.673783),  Route carried "on" structure: US 27,  Year Built: 1971,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 5.55m (18.21ft),  Average Daily Traffic: 21,250 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 36,869 (year 2042),  Design Load: HL 93,  Features Intersected: US-192
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 112000,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 22.3m (73.2ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.5m (90.2ft),  Curb-To-Curb Width: 22.3m (73.2ft),  Out-to-Out Width: 23.2m (76.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 41.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 750083,  Location: .3 Mi E of Lake Co Line (Lat: 28.346919,  Lng: -81.651972),  Route carried "on" structure: US 192,  Year Built: 1971,  Year Reconstructed: 2014,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 45,500 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 78,942 (year 2042),  Design Load: H 20,  Features Intersected: Unnamed
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.492,  Lanes on structure: 7,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 30.5m (100.1ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 42.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.94m (3.08ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $10,000,  Total Project Cost: $609,000
Find on map >>   Show street view

Structure Number: 920094,  Location: I-4 WB over CR-532 (Lat: 28.260900,  Lng: -81.613339),  Route carried "on" structure: Interstate 4,  Year Built: 1960,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 5.48m (17.98ft),  Average Daily Traffic: 57,500 (year 2020),  Truck Traffic: 17%,  Average Future Daily Traffic: 99,762 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: CR-532
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.164,  Lanes on structure: 3,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.1m (49.5ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 15.1m (49.5ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 45.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 920095,  Location: I-4 EB - CR-532 (Lat: 28.260828,  Lng: -81.612936),  Route carried "on" structure: Interstate 4,  Year Built: 1960,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 5.48m (17.98ft),  Average Daily Traffic: 57,500 (year 2020),  Truck Traffic: 17%,  Average Future Daily Traffic: 99,762 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: CR-532
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.188,  Lanes on structure: 3,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 45.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 920097,  Location: 1.3 MI N of Polk Co. Line (Lat: 28.274356,  Lng: -81.600411),  Route carried "on" structure: Interstate 400,  Year Built: 1960,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 8.14m (26.71ft),  Average Daily Traffic: 120,000 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 208,200 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: Davenport Creek,  Facility Carried by Structure: I-4
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.173,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 35.4m (116.1ft),  Skew: 24 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 55.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 43.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Underwater Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 920202,  Location: 0.8 Mi E of CR-532 (Lat: 28.270556,  Lng: -81.603978),  Route carried "on" structure: Interstate 400,  Year Built: 1960,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 120,000 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 208,200 (year 2042),  Design Load: H 15,  Features Intersected: Ditch,  Facility Carried by Structure: I-4
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.547,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 30.5m (100.1ft),  Skew: 13 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.2m (10.5ft)

Condition: Channel: Good,  Culverts: Fair,  Operating Rating: 81.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020
Find on map >>   Show street view

Structure Number: 920203,  Location: 2.0 Mi N of Polk Co. Line (Lat: 28.281758,  Lng: -81.593358),  Route carried "on" structure: Interstate 4,  Year Built: 1960,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 0.65m (2.13ft),  Average Daily Traffic: 60,000 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 104,100 (year 2042),  Design Load: HS 20,  Features Intersected: Ditch
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.225,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 30.5m (100.1ft),  Skew: 32 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 56.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 920601,  Location: SR 429 & I-4 INTERCHANGE (Lat: 28.282506,  Lng: -81.593011),  Route carried "on" structure: Ramp State highway 429,  Year Built: 2006,  Status: Open,  Structure Length: 31.64m (103.81ft),  Average Daily Traffic: 8,100 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 14,054 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: I-4 & SR 429 SB RAMP C
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.669,  Lanes on structure: 1,  Lanes under structure: 7,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 13.1m (43.0ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 77.8m (255.2ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 15.0m (49.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 59.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Critical Feature Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 920602,  Location: SR 429 & I-4 INTERCHANGE (Lat: 28.282847,  Lng: -81.591517),  Route carried "on" structure: Ramp State highway 429,  Year Built: 2006,  Status: Open,  Structure Length: 35.59m (116.77ft),  Average Daily Traffic: 2,300 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 3,990 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: I-4 & CR 545
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 0.312,  Lanes on structure: 1,  Lanes under structure: 8,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 13.1m (43.0ft),  Material/Design: Steel continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 71.0m (232.9ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 15.0m (49.2ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 56.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Critical Feature Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 920603,  Location: 1.7 MI NORTH OF I-4 (Lat: 28.303186,  Lng: -81.607617),  Route carried "on" structure: State highway 429,  Year Built: 2006,  Status: Open,  Structure Length: 2.15m (7.05ft),  Average Daily Traffic: 12,100 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 20,994 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: SAND HILL ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.194,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.5m (70.5ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 15.0m (49.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 920604,  Location: 1.7 MI NORTH OF I-4 (Lat: 28.303197,  Lng: -81.607339),  Route carried "on" structure: State highway 429,  Year Built: 2006,  Status: Open,  Structure Length: 2.15m (7.05ft),  Average Daily Traffic: 12,100 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 20,994 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: SAND HILL ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.194,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.5m (70.5ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.7m (44.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 61.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 920605,  Location: 1.0 MI SOUTH OF US 192 (Lat: 28.332625,  Lng: -81.615431),  Route carried "on" structure: State highway 429,  Year Built: 2006,  Status: Open,  Structure Length: 4.34m (14.24ft),  Average Daily Traffic: 12,100 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 20,994 (year 2042),  Design Load: HL 93,  Features Intersected: FUNIE STEED ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.642,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 43.4m (142.4ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 55.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 49.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 920606,  Location: 1.0 MI SOUTH OF US 192 (Lat: 28.332528,  Lng: -81.615147),  Route carried "on" structure: State highway 429,  Year Built: 2006,  Status: Open,  Structure Length: 4.34m (14.24ft),  Average Daily Traffic: 12,100 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 20,994 (year 2042),  Design Load: HL 93,  Features Intersected: FUNIE STEED ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.633,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 43.4m (142.4ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 55.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 49.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 920607,  Location: 0.7MI W of Lake Wilson Rd (Lat: 28.295278,  Lng: -81.602528),  Route carried "on" structure: County highway ,  Year Built: 2004,  Status: Open,  Structure Length: 6.04m (19.82ft),  Average Daily Traffic: 8,000 (year 2021),  Truck Traffic: 13%,  Average Future Daily Traffic: 13,880 (year 2042),  Design Load: HL 93,  Features Intersected: SR-429 Western Beltway,  Facility Carried by Structure: Sinclair Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.082,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 24.2m (79.4ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.2m (99.1ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 24.5m (80.4ft),  Out-to-Out Width: 28.6m (93.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 74.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 920608,  Location: 2.0 MI SOUTH OF US 192 (Lat: 28.318503,  Lng: -81.608789),  Route carried "on" structure: County highway ,  Year Built: 2006,  Status: Open,  Structure Length: 6.79m (22.28ft),  Average Daily Traffic: 24,900 (year 2018),  Truck Traffic: 15%,  Average Future Daily Traffic: 43,202 (year 2040),  Design Load: HL 93,  Features Intersected: SR 429,  Facility Carried by Structure: DREAMER'S DR 0.286
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.460,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Toll Authority,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.6m (116.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 50.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 45.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 924178,  Location: 0.2 MI W OF FORMOSA GARDE (Lat: 28.320717,  Lng: -81.610694),  Route carried "on" structure: City street ,  Year Built: 2001,  Status: Open,  Structure Length: 7.03m (23.06ft),  Average Daily Traffic: 100 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,500 (year 2033),  Design Load: HS 20,  Features Intersected: SR 429 W BELTWAY,  Facility Carried by Structure: INDIAN CK BLVD 0.1
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.108,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Toll Authority,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.2m (115.5ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 10.9m (35.8ft),  Out-to-Out Width: 13.7m (44.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 34.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 26.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 110036,  Location: US-27 NB over US-192 (Lat: 28.346997,  Lng: -81.673558),  Route carried "under" structure: US 600,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 45,500 (year 2020),  Truck Traffic: 6%,  Features Intersected: US-192,  Facility Carried by Structure: US-27 NB
Minimum Vertical Clearance: 5.36m (17.59ft),  Kilometerpoint: 0.488,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 11094,  Location: US-27 SB over US-192 (Lat: 28.346994,  Lng: -81.673783),  Route carried "under" structure: US 600,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 45,500 (year 2020),  Truck Traffic: 6%,  Features Intersected: US-192,  Facility Carried by Structure: US-27 SB
Minimum Vertical Clearance: 5.36m (17.59ft),  Kilometerpoint: 0.467,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.5m (90.2ft)

Find on map >>   Show street view

Structure Number: 920094,  Location: I-4 WB over CR-532 (Lat: 28.260900,  Lng: -81.613339),  Route carried "under" structure: County highway 532,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 13,300 (year 2020),  Truck Traffic: 13%,  Features Intersected: CR-532,  Facility Carried by Structure: I-4 WB
Minimum Vertical Clearance: 5.24m (17.19ft),  Kilometerpoint: 0.164,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.8m (51.8ft)

Find on map >>   Show street view

Structure Number: 920095,  Location: I-4 EB - CR-532 (Lat: 28.260828,  Lng: -81.612936),  Route carried "under" structure: County highway ,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 13,300 (year 2020),  Truck Traffic: 13%,  Features Intersected: CR-532,  Facility Carried by Structure: I-4 EB
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 0.188,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.8m (51.8ft)

Find on map >>   Show street view

Structure Number: 920601,  Location: SR 429 & I-4 INTERCHANGE (Lat: 28.282506,  Lng: -81.593011),  Route carried "under" structure: Interstate 400,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 120,000 (year 2020),  Truck Traffic: 12%,  Features Intersected: I-4 & SR 429 SB RAMP C,  Facility Carried by Structure: SR 429 NB RAMP B
Minimum Vertical Clearance: 12.04m (39.50ft),  Kilometerpoint: 3.244,  Lanes on structure: 1,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 77.8m (255.2ft)

Find on map >>   Show street view

Structure Number: 920601,  Location: SR 429 & I-4 INTERCHANGE (Lat: 28.282506,  Lng: -81.593011),  Route carried "under" structure: Ramp State highway 429,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 2,300 (year 2020),  Truck Traffic: 12%,  Features Intersected: I-4 & SR 429 SB RAMP C
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 0.322,  Lanes on structure: 1,  Lanes under structure: 1,  Toll: On toll road,  Material/Design: Steel continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 77.8m (255.2ft)

Find on map >>   Show street view

Structure Number: 920602,  Location: SR 429 & I-4 INTERCHANGE (Lat: 28.282847,  Lng: -81.591517),  Route carried "under" structure: County highway 545,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 16,700 (year 2020),  Truck Traffic: 13%,  Features Intersected: I-4 & CR 545,  Facility Carried by Structure: SR 429 SB RAMP C
Minimum Vertical Clearance: 5.66m (18.57ft),  Kilometerpoint: 2.736,  Lanes on structure: 1,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 71.0m (232.9ft)

Find on map >>   Show street view

Structure Number: 920602,  Location: SR 429 & I-4 INTERCHANGE (Lat: 28.282847,  Lng: -81.591517),  Route carried "under" structure: Interstate 400,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 120,000 (year 2020),  Truck Traffic: 12%,  Features Intersected: I-4 & CR 545,  Facility Carried by Structure: SR 429 SB RAMP C
Minimum Vertical Clearance: 7.21m (23.65ft),  Kilometerpoint: 3.362,  Lanes on structure: 1,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 71.0m (232.9ft)

Find on map >>   Show street view

Structure Number: 920603,  Location: 1.7 MI NORTH OF I-4 (Lat: 28.303186,  Lng: -81.607617),  Route carried "under" structure: County highway ,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 100 (year 2006),  Truck Traffic: 2%,  Features Intersected: SAND HILL ROAD,  Facility Carried by Structure: SR 429 SB 2.3
Minimum Vertical Clearance: 5.92m (19.42ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.5m (70.5ft)

Find on map >>   Show street view

Structure Number: 920604,  Location: 1.7 MI NORTH OF I-4 (Lat: 28.303197,  Lng: -81.607339),  Route carried "under" structure: County highway ,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 100 (year 2006),  Truck Traffic: 2%,  Features Intersected: SAND HILL ROAD,  Facility Carried by Structure: SR 429 NB 2.3
Minimum Vertical Clearance: 5.06m (16.60ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.5m (70.5ft)

Find on map >>   Show street view

Structure Number: 920605,  Location: 1.0 MI SOUTH OF US 192 (Lat: 28.332625,  Lng: -81.615431),  Route carried "under" structure: City street ,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 8,300 (year 2020),  Truck Traffic: 6%,  Features Intersected: FUNIE STEED ROAD,  Facility Carried by Structure: SR 429 SB 4.5
Minimum Vertical Clearance: 5.31m (17.42ft),  Kilometerpoint: 3.405,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 43.4m (142.4ft)

Find on map >>   Show street view

Structure Number: 920606,  Location: 1.0 MI SOUTH OF US 192 (Lat: 28.332528,  Lng: -81.615147),  Route carried "under" structure: City street ,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 8,300 (year 2020),  Truck Traffic: 6%,  Features Intersected: FUNIE STEED ROAD,  Facility Carried by Structure: SR 429 NB 4.5
Minimum Vertical Clearance: 5.49m (18.01ft),  Kilometerpoint: 3.434,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 43.4m (142.4ft)

Find on map >>   Show street view

Structure Number: 920607,  Location: 0.7MI W of Lake Wilson Rd (Lat: 28.295278,  Lng: -81.602528),  Route carried "under" structure: State highway 429,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 24,700 (year 2021),  Truck Traffic: 11%,  Features Intersected: SR-429 Western Beltway,  Facility Carried by Structure: Sinclair Road
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 1.188,  Lanes on structure: 4,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.2m (99.1ft)

Find on map >>   Show street view

Structure Number: 920608,  Location: 2.0 MI SOUTH OF US 192 (Lat: 28.318503,  Lng: -81.608789),  Route carried "under" structure: State highway 429,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 24,200 (year 2020),  Truck Traffic: 12%,  Features Intersected: SR 429,  Facility Carried by Structure: DREAMER'S DR 0.286
Minimum Vertical Clearance: 6.95m (22.80ft),  Kilometerpoint: 3.916,  Lanes on structure: 2,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.6m (116.8ft)

Find on map >>   Show street view

Structure Number: 924178,  Location: 0.2 MI W OF FORMOSA GARDE (Lat: 28.320717,  Lng: -81.610694),  Route carried "under" structure: State highway 429,  Year Built: 2001,  Structure Length: 0. m,  Average Daily Traffic: 24,200 (year 2020),  Truck Traffic: 12%,  Features Intersected: SR 429 W BELTWAY,  Facility Carried by Structure: INDIAN CK BLVD 0.1
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 4.226,  Lanes on structure: 2,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.2m (115.5ft)

Discuss Citrus Ridge, Florida (FL) on our hugely popular Florida forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.