Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for De Witt, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 20Number of bridges
  • 243ft / 74.5mTotal length
  • $63,000Total costs
  • 311,864Total average daily traffic
  • 36,677Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for De Witt
  • No street view available for this location

New bridges in De Witt, MI - historical statistics
  • New bridges - historical statistics
  • 11960-1969
  • 21970-1979
  • 71980-1989
  • 101990-1999
Average Bridge Daily Traffic in De Witt, MI
Average Bridge Truck Traffic in De Witt, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 9.1%Very good
  • 54.5%Good
  • 27.3%Satisfactory
  • 9.1%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 54.5%Good
  • 36.4%Satisfactory
  • 9.1%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 72.7%Good
  • 9.1%Satisfactory
  • 18.2%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 14.3%Very good
  • 42.9%Good
  • 14.3%Satisfactory
  • 28.6%Fair
Find on map >>   Show street view

Structure Number: 1859,  Location: 0.1 MILE NW OF WOOD ST (Lat: 42.817736,  Lng: -84.527847),  Route carried "on" structure: Interstate 69,  Year Built: 1973,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 37,978 (year 2007),  Truck Traffic: 16%,  Average Future Daily Traffic: 49,205 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: CHANDLER DRAIN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 13.570,  Lanes on structure: 6,  Base Highway Network: Yes (Inventory Route: 36,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.6m (11.8ft),  Curb-To-Curb Width: 28.0m (91.9ft),  Out-to-Out Width: 80.5m (264.1ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 97.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 187,  Location: 0.75 MI SE OF DEWITT (Lat: 42.813278,  Lng: -84.581100),  Route carried "on" structure: County highway ,  Year Built: 1980,  Status: Open,  Structure Length: 12.31m (40.39ft),  Average Daily Traffic: 450 (year 1984),  Truck Traffic: 4%,  Average Future Daily Traffic: 4,000 (year 2015),  Design Load: HS 25 or greater,  Features Intersected: I-69,  Facility Carried by Structure: CLARK RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 22.139,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 49.3m (161.7ft),  Curb-To-Curb Width: 12.9m (42.3ft),  Out-to-Out Width: 13.6m (44.6ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 78.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 188,  Location: 1.2 MI S OF DEWITT (Lat: 42.817208,  Lng: -84.560839),  Route carried "on" structure: Interstate 69,  Year Built: 1980,  Status: Open,  Structure Length: 3.44m (11.29ft),  Average Daily Traffic: 18,999 (year 2007),  Truck Traffic: 17%,  Average Future Daily Traffic: 25,598 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: TURNER RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.894,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 36,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 34.4m (112.9ft),  Curb-To-Curb Width: 12.5m (41.0ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 88.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 52.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1928,  Location: BETWEEN HERBISON RDS (Lat: 42.824736,  Lng: -84.602683),  Route carried "on" structure: County highway 1949,  Year Built: 1993,  Status: Open,  Structure Length: 3.41m (11.19ft),  Average Daily Traffic: 4,115 (year 2011),  Truck Traffic: 2%,  Average Future Daily Traffic: 7,432 (year 2031),  Design Load: HS 20,  Features Intersected: LOOKING GLASS RIVER,  Facility Carried by Structure: AIRPORT ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.016,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 32.0m (105.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 15.1m (49.5ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 97.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 58.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1933,  Location: 1/4 MI S OF ROUND LAKE (Lat: 42.853733,  Lng: -84.523167),  Route carried "on" structure: County highway 1969,  Year Built: 1964,  Status: Open,  Structure Length: 3.84m (12.60ft),  Average Daily Traffic: 1,632 (year 2013),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,992 (year 2033),  Design Load: HS 20,  Features Intersected: LOOKING GLASS RIVER,  Facility Carried by Structure: WOOD ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.360,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.8m (42.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 62.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 3.84m (12.60ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Bridge Improvement Cost: $53,000,  Total Project Cost: $63,000,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 2026,  Location: 0.8 MI N OF S CITY LIMITS (Lat: 42.839903,  Lng: -84.569131),  Route carried "on" structure: City street 1959,  Year Built: 1993,  Status: Open,  Structure Length: 2.37m (7.78ft),  Average Daily Traffic: 3,900 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 4,700 (year 2026),  Design Load: HS 20,  Features Intersected: LOOKING GLASS RIVER,  Facility Carried by Structure: BRIDGE STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.645,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 11.8m (38.7ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 15.1m (49.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 94.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 56.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2027,  Location: N CITY LIMITS OF DEWITT (Lat: 42.842067,  Lng: -84.588692),  Route carried "on" structure: City street ,  Year Built: 1981,  Status: Open,  Structure Length: 2.62m (8.60ft),  Average Daily Traffic: 2,500 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,700 (year 2026),  Design Load: HS 20,  Features Intersected: LOOKING GLASS RIVER,  Facility Carried by Structure: SCHAVEY ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.201,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 13.1m (43.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Good,  Operating Rating: 48.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 28.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 12672,  Location: 1.2 M N LOOKING GLASS RIV (Lat: 42.870992,  Lng: -84.517775),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 8.87m (29.10ft),  Average Daily Traffic: 800 (year 1996),  Truck Traffic: 3%,  Average Future Daily Traffic: 800 (year 2015),  Design Load: HS 20,  Features Intersected: US-127,  Facility Carried by Structure: CHADWICK ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 19.710,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 33.1m (108.6ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 85.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 12673,  Location: 1 MI S OF GREEN ROAD (Lat: 42.892717,  Lng: -84.517283),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 8.70m (28.54ft),  Average Daily Traffic: 2,700 (year 1995),  Truck Traffic: 3%,  Average Future Daily Traffic: 3,050 (year 2015),  Design Load: HS 20,  Features Intersected: US-127,  Facility Carried by Structure: ALWARD ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.490,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 32.5m (106.6ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 73.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 12693,  Location: DEWITT TWP SEC 2 (Lat: 42.854508,  Lng: -84.518992),  Route carried "on" structure: US 127,  Year Built: 1997,  Status: Open,  Structure Length: 9.28m (30.45ft),  Average Daily Traffic: 14,359 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 18,793 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: LOOKING GLASS RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 9.569,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 36,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 17.4m (57.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 30.9m (101.4ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.1m (59.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 73.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 12694,  Location: DEWITT TWP SEC 2 (Lat: 42.854658,  Lng: -84.518483),  Route carried "on" structure: US 127,  Year Built: 1997,  Status: Open,  Structure Length: 9.28m (30.45ft),  Average Daily Traffic: 14,359 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 18,793 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: LOOKING GLASS RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 9.558,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 36,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 30.9m (101.4ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.1m (59.4ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 64.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 127,  Location: 0.1 M N LOOKING GLASS RIV (Lat: 42.856500,  Lng: -84.518486),  Route carried "on" structure: County highway ,  Year Built: 1997,  Status: Open,  Structure Length: 9.63m (31.59ft),  Average Daily Traffic: 6,500 (year 1997),  Truck Traffic: 3%,  Average Future Daily Traffic: 6,500 (year 2017),  Design Load: HS 20+Mod,  Features Intersected: US-127,  Facility Carried by Structure: ROUND LAKE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 26.656,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 37.6m (123.4ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.6m (51.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1867,  Location: AT N LTS OF LANSING (Lat: 42.817750,  Lng: -84.542783),  Route carried "under" structure: Interstate 69,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 37,998 (year 2007),  Truck Traffic: 16%,  Features Intersected: I-69,  Facility Carried by Structure: US-127 BR
Minimum Vertical Clearance: 4.90m (16.08ft),  Kilometerpoint: 12.349,  Lanes on structure: 6,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.8m (127.3ft)

Find on map >>   Show street view

Structure Number: 1868,  Location: 1.2 MI S OF DEWITT (Lat: 42.816886,  Lng: -84.560556),  Route carried "under" structure: County highway ,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 3,518 (year 1984),  Truck Traffic: 4%,  Features Intersected: TURNER RD,  Facility Carried by Structure: I-69 WB
Minimum Vertical Clearance: 4.70m (15.42ft),  Kilometerpoint: 5.425,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.4m (112.9ft)

Find on map >>   Show street view

Structure Number: 1869,  Location: 0.6 MI SE OF DEWITT (Lat: 42.816203,  Lng: -84.572372),  Route carried "under" structure: Interstate 69,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 37,998 (year 2007),  Truck Traffic: 17%,  Features Intersected: I-69,  Facility Carried by Structure: DEWITT RD
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 9.925,  Lanes on structure: 5,  Lanes under structure: 5,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.3m (128.9ft)

Find on map >>   Show street view

Structure Number: 187,  Location: 0.75 MI SE OF DEWITT (Lat: 42.813278,  Lng: -84.581100),  Route carried "under" structure: Interstate 69,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 37,978 (year 2007),  Truck Traffic: 16%,  Features Intersected: I-69,  Facility Carried by Structure: CLARK RD
Minimum Vertical Clearance: 5.31m (17.42ft),  Kilometerpoint: 15.254,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 49.3m (161.7ft)

Find on map >>   Show street view

Structure Number: 188,  Location: 1.2 MI S OF DEWITT (Lat: 42.817208,  Lng: -84.560839),  Route carried "under" structure: County highway ,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 3,518 (year 1984),  Features Intersected: TURNER RD,  Facility Carried by Structure: I-69 EB
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 5.383,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.4m (112.9ft)

Find on map >>   Show street view

Structure Number: 12672,  Location: 1.2 M N LOOKING GLASS RIV (Lat: 42.870992,  Lng: -84.517775),  Route carried "under" structure: US 127,  Year Built: 1996,  Structure Length: 0. m,  Average Daily Traffic: 26,922 (year 2007),  Truck Traffic: 7%,  Features Intersected: US-127,  Facility Carried by Structure: CHADWICK ROAD
Minimum Vertical Clearance: 5.26m (17.26ft),  Kilometerpoint: 11.399,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.1m (108.6ft)

Find on map >>   Show street view

Structure Number: 12673,  Location: 1 MI S OF GREEN ROAD (Lat: 42.892717,  Lng: -84.517283),  Route carried "under" structure: US 127,  Year Built: 1996,  Structure Length: 0. m,  Average Daily Traffic: 26,922 (year 2007),  Truck Traffic: 7%,  Features Intersected: US-127,  Facility Carried by Structure: ALWARD ROAD
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 13.855,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.5m (106.6ft)

Find on map >>   Show street view

Structure Number: 127,  Location: 0.1 M N LOOKING GLASS RIV (Lat: 42.856500,  Lng: -84.518486),  Route carried "under" structure: US 127,  Year Built: 1997,  Structure Length: 0. m,  Average Daily Traffic: 28,718 (year 2007),  Truck Traffic: 7%,  Features Intersected: US-127,  Facility Carried by Structure: ROUND LAKE ROAD
Minimum Vertical Clearance: 5.64m (18.50ft),  Kilometerpoint: 9.785,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 37.6m (123.4ft)

Discuss De Witt, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.