  • 25Number of bridges
  • 243ft / 74.3mTotal length
  • 79,186Total average daily traffic
  • 14,431Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Drummond
  • No street view available for this location

New bridges in Drummond, MT - historical statistics
  • New bridges - historical statistics
  • 21930-1939
  • 201960-1969
  • 31990-1999
Reconstructed bridges in Drummond, MT - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11970-1979
  • 01980-1989
  • 71990-1999
Average Bridge Daily Traffic in Drummond, MT
Average Bridge Truck Traffic in Drummond, MT
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 64.7%Good
  • 29.4%Satisfactory
  • 5.9%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 23.5%Very good
  • 47.1%Good
  • 17.6%Satisfactory
  • 11.8%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 5.9%Very good
  • 70.6%Good
  • 11.8%Satisfactory
  • 5.9%Fair
  • 5.9%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 66.7%Very good
  • 16.7%Good
  • 16.7%Satisfactory
Find on map >>   Show street view

Structure Number: I00090153+03561,  Location: DRUMMOND (Lat: 46.672000,  Lng: -113.153694),  Route carried "on" structure: Interstate 90,  Year Built: 1966,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 3.81m (12.50ft),  Average Daily Traffic: 8,044 (year 2020),  Truck Traffic: 22%,  Average Future Daily Traffic: 8,446 (year 2040),  Design Load: HS 20,  Features Intersected: INT W DRUMMOND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 245.791,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.0m (45.9ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 48.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 34.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: I00090153+03562,  Location: DRUMMOND (Lat: 46.672097,  Lng: -113.153686),  Route carried "on" structure: Interstate 90,  Year Built: 1966,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 3.81m (12.50ft),  Average Daily Traffic: 8,044 (year 2020),  Truck Traffic: 22%,  Average Future Daily Traffic: 8,446 (year 2040),  Design Load: HS 20,  Features Intersected: INT W DRUMMOND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 245.833,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.0m (45.9ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 48.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 34.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: I00090153+07641,  Location: DRUMMOND (Lat: 46.670403,  Lng: -113.145819),  Route carried "on" structure: Interstate 90,  Year Built: 1966,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 3.90m (12.80ft),  Average Daily Traffic: 8,044 (year 2020),  Truck Traffic: 22%,  Average Future Daily Traffic: 8,446 (year 2040),  Design Load: HS 20,  Features Intersected: SEP EDWARDS GULCH ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 246.438,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.1m (36.4ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.0m (45.9ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 38.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: I00090153+07642,  Location: DRUMMOND (Lat: 46.670492,  Lng: -113.145739),  Route carried "on" structure: Interstate 90,  Year Built: 1966,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 8,044 (year 2020),  Truck Traffic: 22%,  Average Future Daily Traffic: 8,446 (year 2040),  Design Load: HS 20,  Features Intersected: SEP EDWARDS GULCH ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 246.485,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.4m (37.4ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 38.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: I00090154+02801,  Location: DRUMMOND (Lat: 46.664939,  Lng: -113.138397),  Route carried "on" structure: Interstate 90,  Year Built: 1966,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 4.11m (13.48ft),  Average Daily Traffic: 8,044 (year 2020),  Truck Traffic: 22%,  Average Future Daily Traffic: 8,446 (year 2040),  Design Load: HS 20,  Features Intersected: INT E DRUMMOND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 247.275,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 11 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 11.4m (37.4ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: I00090154+02802,  Location: DRUMMOND (Lat: 46.665106,  Lng: -113.138222),  Route carried "on" structure: Interstate 90,  Year Built: 1966,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 4.11m (13.48ft),  Average Daily Traffic: 8,342 (year 2020),  Truck Traffic: 21%,  Average Future Daily Traffic: 8,759 (year 2040),  Design Load: HS 20,  Features Intersected: INT E DRUMMOND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 247.322,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 11 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 11.2m (36.7ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: I00090155+07871,  Location: 1.2M E DRUMMOND (Lat: 46.647950,  Lng: -113.118672),  Route carried "on" structure: Interstate 90,  Year Built: 1966,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 8,342 (year 2020),  Truck Traffic: 21%,  Average Future Daily Traffic: 8,759 (year 2040),  Design Load: HS 20,  Features Intersected: SEP S-271
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 249.694,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.0m (45.9ft),  Curb-To-Curb Width: 11.4m (37.4ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 48.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: I00090155+07872,  Location: 1.2M E DRUMMOND (Lat: 46.648042,  Lng: -113.118383),  Route carried "on" structure: Interstate 90,  Year Built: 1966,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 8,342 (year 2020),  Truck Traffic: 21%,  Average Future Daily Traffic: 8,759 (year 2040),  Design Load: HS 20,  Features Intersected: SEP S-271
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 249.753,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.0m (45.9ft),  Curb-To-Curb Width: 11.2m (36.7ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: L20007000+08001,  Location: 2M S DRUMMOND (Lat: 46.629172,  Lng: -113.154750),  Route carried "on" structure: Spur County highway 20006,  Year Built: 1998,  Status: Open,  Structure Length: 1.49m (4.89ft),  Average Daily Traffic: 100 (year 2022),  Truck Traffic: 3%,  Average Future Daily Traffic: 100 (year 2037),  Design Load: HS 20,  Features Intersected: FLINT CREEK OVERFLOW 084,  Facility Carried by Structure: MULLAN RD E
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.287,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.5m (44.3ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 75.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: L20007001+00001,  Location: 2M S DRUMMOND (Lat: 46.628742,  Lng: -113.151244),  Route carried "on" structure: Spur County highway 20006,  Year Built: 1998,  Status: Open,  Structure Length: 1.84m (6.04ft),  Average Daily Traffic: 100 (year 2022),  Truck Traffic: 3%,  Average Future Daily Traffic: 100 (year 2037),  Design Load: HS 20,  Features Intersected: FLINT CREEK 001,  Facility Carried by Structure: MULLAN RD E
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.563,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.0m (55.8ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: L20016000+05001,  Location: S DRUMMOND (Lat: 46.662125,  Lng: -113.150189),  Route carried "on" structure: County highway 20016,  Year Built: 1934,  Status: Open,  Structure Length: 8.14m (26.71ft),  Average Daily Traffic: 519 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 545 (year 2040),  Design Load: H 15,  Features Intersected: CLARK FORK RIVER 020,  Facility Carried by Structure: S MAIN STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.080,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 22.9m (75.1ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.7m (25.3ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 35.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 21.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: May 2020,  Underwater Inspection Date: October 2018,  Other Special Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: M20035000+00101,  Location: DRUMMOND-MAIN STREET (Lat: 46.666653,  Lng: -113.147292),  Route carried "on" structure: City street 20035,  Year Built: 1934,  Status: Posted for load,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 500 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 525 (year 2040),  Design Load: H 15,  Features Intersected: BERGMAN SLOUGH 019,  Facility Carried by Structure: MAIN ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.616,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 6.5m (21.3ft),  Out-to-Out Width: 6.7m (22.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 42.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 29.9 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: P00019000+00001,  Location: 6M S WARM SPRINGS (Lat: 46.095586,  Lng: -112.792939),  Route carried "on" structure: Alternate State highway 1,  Year Built: 1964,  Status: Open,  Structure Length: 8.41m (27.59ft),  Average Daily Traffic: 3,774 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,963 (year 2040),  Design Load: HS 20,  Features Intersected: INT I 90
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 22 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 17.2m (56.4ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 56.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: P00019059+07341,  Location: 4M S DRUMMOND (Lat: 46.613769,  Lng: -113.177656),  Route carried "on" structure: Alternate State highway 1,  Year Built: 1999,  Status: Open,  Structure Length: 2.03m (6.66ft),  Average Daily Traffic: 1,467 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,606 (year 2040),  Design Load: HS 20,  Features Intersected: WILLOW CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 95.563,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.9m (62.0ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.7m (38.4ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: P00019063+02511,  Location: DRUMMOND (Lat: 46.661561,  Lng: -113.157114),  Route carried "on" structure: Alternate State highway 1,  Year Built: 1966,  Status: Open,  Structure Length: 9.17m (30.09ft),  Average Daily Traffic: 1,256 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,375 (year 2040),  Design Load: HS 20,  Features Intersected: CLARK FORK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 101.154,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 18.6m (61.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Poor,  Channel: Satisfactory,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2020,  Underwater Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: P00019063+04351,  Location: DRUMMOND (Lat: 46.664886,  Lng: -113.155650),  Route carried "on" structure: Alternate State highway 1,  Year Built: 1966,  Status: Open,  Structure Length: 5.03m (16.50ft),  Average Daily Traffic: 1,256 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,375 (year 2040),  Design Load: HS 20,  Features Intersected: ABANDONED RAILROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 101.537,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.9m (62.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 47.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: P00019063+08231,  Location: DRUMMOND (Lat: 46.669506,  Lng: -113.153772),  Route carried "on" structure: Alternate State highway 1,  Year Built: 1966,  Year Reconstructed: 1983,  Status: Open,  Structure Length: 5.79m (19.00ft),  Average Daily Traffic: 1,256 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,375 (year 2040),  Design Load: HS 20,  Features Intersected: RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 102.074,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.9m (71.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: I00090153+03561,  Location: DRUMMOND (Lat: 46.672000,  Lng: -113.153694),  Route carried "under" structure: Alternate State highway 1,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 1,310 (year 2020),  Truck Traffic: 3%,  Features Intersected: INT W DRUMMOND,  Facility Carried by Structure: I 90
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.001,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.0m (45.9ft)

Find on map >>   Show street view

Structure Number: I00090153+03562,  Location: DRUMMOND (Lat: 46.672097,  Lng: -113.153686),  Route carried "under" structure: ServiceState highway 1,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 1,310 (year 2020),  Truck Traffic: 3%,  Features Intersected: INT W DRUMMOND,  Facility Carried by Structure: I 90
Minimum Vertical Clearance: 4.69m (15.39ft),  Kilometerpoint: 0.012,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.0m (45.9ft)

Find on map >>   Show street view

Structure Number: I00090153+07641,  Location: DRUMMOND (Lat: 46.670403,  Lng: -113.145819),  Route carried "under" structure: ServiceState highway 20000,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 274 (year 2020),  Truck Traffic: 3%,  Features Intersected: SEP EDWARDS GULCH ROAD,  Facility Carried by Structure: I 90
Minimum Vertical Clearance: 5.38m (17.65ft),  Kilometerpoint: 0.332,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.0m (45.9ft)

Find on map >>   Show street view

Structure Number: I00090153+07642,  Location: DRUMMOND (Lat: 46.670492,  Lng: -113.145739),  Route carried "under" structure: ServiceState highway 20000,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 274 (year 2020),  Truck Traffic: 3%,  Features Intersected: SEP EDWARDS GULCH ROAD,  Facility Carried by Structure: I 90
Minimum Vertical Clearance: 5.38m (17.65ft),  Kilometerpoint: 0.344,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 13.7m (44.9ft)

Find on map >>   Show street view

Structure Number: I00090154+02801,  Location: DRUMMOND (Lat: 46.664939,  Lng: -113.138397),  Route carried "under" structure: State highway 96,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 48 (year 2020),  Truck Traffic: 3%,  Features Intersected: INT E DRUMMOND,  Facility Carried by Structure: I 90
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 0.002,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.5m (50.9ft)

Find on map >>   Show street view

Structure Number: I00090154+02802,  Location: DRUMMOND (Lat: 46.665106,  Lng: -113.138222),  Route carried "under" structure: US 88,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 48 (year 2020),  Truck Traffic: 3%,  Features Intersected: INT E DRUMMOND,  Facility Carried by Structure: I 90
Minimum Vertical Clearance: 4.89m (16.04ft),  Kilometerpoint: 0.025,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.5m (50.9ft)

Find on map >>   Show street view

Structure Number: I00090155+07871,  Location: 12M E DRUMMOND (Lat: 46.647950,  Lng: -113.118672),  Route carried "under" structure: State highway 271,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 224 (year 2020),  Truck Traffic: 5%,  Features Intersected: SEP S-271,  Facility Carried by Structure: I 90
Minimum Vertical Clearance: 5.36m (17.59ft),  Kilometerpoint: 2.429,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.0m (45.9ft)

Find on map >>   Show street view

Structure Number: I00090155+07872,  Location: 12M E DRUMMOND (Lat: 46.648042,  Lng: -113.118383),  Route carried "under" structure: State highway 271,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 224 (year 2020),  Truck Traffic: 5%,  Features Intersected: SEP S-271,  Facility Carried by Structure: I 90
Minimum Vertical Clearance: 4.77m (15.65ft),  Kilometerpoint: 2.453,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.0m (45.9ft)