Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Fenton, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 18Number of bridges
  • 151ft / 46.2mTotal length
  • $800,000Total costs
  • 291,654Total average daily traffic
  • 22,571Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Fenton
  • No street view available for this location

New bridges in Fenton, MI - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 91950-1959
  • 41960-1969
  • 11970-1979
  • 11990-1999
  • 12000-2009
  • 12010-2019
Reconstructed bridges in Fenton, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 01960-1969
  • 01970-1979
  • 11980-1989
Average Bridge Daily Traffic in Fenton, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 33.3%Good
  • 22.2%Satisfactory
  • 44.4%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 22.2%Very good
  • 33.3%Good
  • 44.4%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 33.3%Good
  • 55.6%Satisfactory
  • 11.1%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 25.0%Very good
  • 12.5%Good
  • 50.0%Satisfactory
  • 12.5%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 33.3%Very good
  • 33.3%Fair
  • 33.3%Poor
Find on map >>   Show street view

Structure Number: 2466,  Location: IN FENTON (Lat: 42.797714,  Lng: -83.706489),  Route carried "on" structure: City street ,  Year Built: 2016,  Status: Open,  Structure Length: 1.03m (3.38ft),  Average Daily Traffic: 13,800 (year 2015),  Truck Traffic: 10%,  Average Future Daily Traffic: 15,800 (year 2035),  Design Load: Greater than HL93,  Features Intersected: SHIAWASSEE RIVER,  Facility Carried by Structure: SILVER LAKE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.307,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Aluminum, Iron,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.3m (33.8ft),  Curb or Sidewalk Widths: Left: 4.8m (15.7ft),  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 19.2m (63.0ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 69.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 53.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2467,  Location: IN FENTON (Lat: 42.815297,  Lng: -83.725844),  Route carried "on" structure: US 23,  Year Built: 1957,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 23,577 (year 2007),  Truck Traffic: 9%,  Average Future Daily Traffic: 37,269 (year 2018),  Design Load: HS 20,  Features Intersected: SHIAWASSEE RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.046,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 150,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 11 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 53.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 2468,  Location: IN FENTON (Lat: 42.815289,  Lng: -83.726128),  Route carried "on" structure: US 23,  Year Built: 1957,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 23,577 (year 2007),  Truck Traffic: 9%,  Average Future Daily Traffic: 37,269 (year 2018),  Design Load: HS 20,  Features Intersected: SHIAWASSEE RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.046,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 150,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 11 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 53.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 2475,  Location: IN FENTON (Lat: 42.804358,  Lng: -83.727442),  Route carried "on" structure: US 23,  Year Built: 1958,  Status: Open,  Structure Length: 10.15m (33.30ft),  Average Daily Traffic: 23,577 (year 2007),  Truck Traffic: 9%,  Average Future Daily Traffic: 37,269 (year 2018),  Design Load: HS 20,  Features Intersected: US-23 BR & GTW RR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.778,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 150,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 10 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 22.5m (73.8ft),  Curb-To-Curb Width: 14.2m (46.6ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 66.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: March 2022,  Other Special Inspection Date: March 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2476,  Location: IN FENTON (Lat: 42.804450,  Lng: -83.727742),  Route carried "on" structure: US 23,  Year Built: 1958,  Status: Open,  Structure Length: 10.15m (33.30ft),  Average Daily Traffic: 23,577 (year 2007),  Truck Traffic: 9%,  Average Future Daily Traffic: 37,269 (year 2018),  Design Load: HS 20,  Features Intersected: US-23 BR & GTW RR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.787,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 150,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 10 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 22.5m (73.8ft),  Curb-To-Curb Width: 14.2m (46.6ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 66.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2477,  Location: OWEN RD (1 MI W / FENTON) (Lat: 42.789733,  Lng: -83.738417),  Route carried "on" structure: US 23,  Year Built: 1957,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 8.11m (26.61ft),  Average Daily Traffic: 16,244 (year 2005),  Truck Traffic: 3%,  Average Future Daily Traffic: 19,132 (year 2018),  Design Load: HS 20,  Features Intersected: US-23
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.909,  Lanes on structure: 5,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 22.2m (72.8ft),  Curb-To-Curb Width: 24.3m (79.7ft),  Out-to-Out Width: 25.4m (83.3ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 80.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2516,  Location: BY FENTON MUNICIPAL BLD (Lat: 42.794725,  Lng: -83.704850),  Route carried "on" structure: City street ,  Year Built: 1906,  Year Reconstructed: 1958,  Status: Open,  Structure Length: 0.80m (2.62ft),  Average Daily Traffic: 10,918 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 12,500 (year 2040),  Design Load: H 10,  Features Intersected: SHIAWASSEE RIVER,  Facility Carried by Structure: LEROY STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.137,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.0m (26.2ft),  Curb or Sidewalk Widths: Left: 2.9m (9.5ft),  Right: 3.5m (11.5ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 20.5m (67.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.83m (6.00ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Bridge Improvement Cost: $450,000,  Roadway Improvement Cost: $125,000,  Total Project Cost: $800,000,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2823,  Location: IN FENTON (Lat: 42.806200,  Lng: -83.708514),  Route carried "on" structure: City street ,  Year Built: 1958,  Status: Posted for load,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 8,043 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 11,330 (year 2027),  Design Load: HS 20,  Features Intersected: SHIAWASSEE RIVER,  Facility Carried by Structure: NORTH ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.180,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 2.3m (7.5ft),  Right: 2.8m (9.2ft),  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 16.7m (54.8ft)

Condition: Channel: Satisfactory,  Culverts: Poor,  Operating Rating: 31.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 18.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2824,  Location: IN FENTON (Lat: 42.796525,  Lng: -83.706825),  Route carried "on" structure: City street ,  Year Built: 1993,  Status: Open,  Structure Length: 1.03m (3.38ft),  Average Daily Traffic: 900 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,050 (year 2040),  Design Load: HS 20,  Features Intersected: SHIAWASSEE RIVER,  Facility Carried by Structure: CAROLINE STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.673,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 83.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 50.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2825,  Location: IN FENTON (Lat: 42.815253,  Lng: -83.725500),  Route carried "on" structure: City street ,  Year Built: 2006,  Status: Open,  Structure Length: 2.93m (9.61ft),  Average Daily Traffic: 9,746 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 11,200 (year 2040),  Design Load: HS 20,  Features Intersected: SHIAWASSEE RIVER,  Facility Carried by Structure: TORREY ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.188,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 79.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 47.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2826,  Location: IN FENTON (Lat: 42.794169,  Lng: -83.701711),  Route carried "on" structure: City street ,  Year Built: 1974,  Status: Open,  Structure Length: 1.76m (5.77ft),  Average Daily Traffic: 1,385 (year 1990),  Average Future Daily Traffic: 11,917 (year 2012),  Design Load: HS 20+Mod,  Features Intersected: SHIAWASSEE RIVER,  Facility Carried by Structure: EAST STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.281,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 4.5m (14.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 23.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 14.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5755,  Location: 1.0 MI S OF GENESEE COL (Lat: 42.768828,  Lng: -83.752011),  Route carried "on" structure: County highway 4794,  Year Built: 1961,  Status: Open,  Structure Length: 6.73m (22.08ft),  Average Daily Traffic: 6,800 (year 2005),  Truck Traffic: 3%,  Average Future Daily Traffic: 7,820 (year 2025),  Design Load: HS 20,  Features Intersected: US-23,  Facility Carried by Structure: WHITE LAKE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.291,  Lanes on structure: 2,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.3m (79.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 59.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 2475,  Location: IN FENTON (Lat: 42.804358,  Lng: -83.727442),  Route carried "under" structure: Business US 23,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 13,072 (year 2005),  Truck Traffic: 3%,  Features Intersected: US-23 BR & GTW RR
Minimum Vertical Clearance: 6.12m (20.08ft),  Kilometerpoint: 1.798,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.5m (73.8ft)

Find on map >>   Show street view

Structure Number: 2476,  Location: IN FENTON (Lat: 42.804450,  Lng: -83.727742),  Route carried "under" structure: Business US 23,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 13,072 (year 2005),  Truck Traffic: 3%,  Features Intersected: US-23 BR & GTW RR
Minimum Vertical Clearance: 6.12m (20.08ft),  Kilometerpoint: 1.823,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.5m (73.8ft)

Find on map >>   Show street view

Structure Number: 2477,  Location: OWEN RD (1 MI W / FENTON) (Lat: 42.789733,  Lng: -83.738417),  Route carried "under" structure: US 23,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 52,326 (year 2007),  Truck Traffic: 9%,  Features Intersected: US-23
Minimum Vertical Clearance: 5.31m (17.42ft),  Kilometerpoint: 0.922,  Lanes on structure: 5,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 22.2m (72.8ft)

Find on map >>   Show street view

Structure Number: 5753,  Location: 3.4 MI S OF GENESEE COL (Lat: 42.737117,  Lng: -83.763806),  Route carried "under" structure: County highway ,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 320 (year 1998),  Features Intersected: CENTER RD,  Facility Carried by Structure: US-23 NB
Minimum Vertical Clearance: 4.75m (15.58ft),  Kilometerpoint: 9.714,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 12.3m (40.4ft)

Find on map >>   Show street view

Structure Number: 5754,  Location: 3.4 MI S OF GENESEE COL (Lat: 42.737103,  Lng: -83.764167),  Route carried "under" structure: County highway ,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 320 (year 1998),  Features Intersected: CENTER RD,  Facility Carried by Structure: US-23 SB
Minimum Vertical Clearance: 4.60m (15.09ft),  Kilometerpoint: 9.684,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 12.3m (40.4ft)

Find on map >>   Show street view

Structure Number: 5755,  Location: 1.0 MI S OF GENESEE COL (Lat: 42.768828,  Lng: -83.752011),  Route carried "under" structure: US 23,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 50,400 (year 2016),  Truck Traffic: 9%,  Features Intersected: US-23,  Facility Carried by Structure: WHITE LAKE RD
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 39.023,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.3m (79.7ft)