Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Huron, Kansas (KS)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 10Number of bridges
  • 62ft / 18.8mTotal length
  • $615,000Total costs
  • 992Total average daily traffic
  • 119Total average daily truck traffic
  • 1,322Total future (year 2040) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Huron
  • No street view available for this location

New bridges in Huron, KS - historical statistics
  • New bridges - historical statistics
  • 31930-1939
  • 41990-1999
  • 12000-2009
  • 22010-2019
Average Bridge Truck Traffic in Huron, KS
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 50.0%Very good
  • 25.0%Good
  • 25.0%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 50.0%Very good
  • 12.5%Good
  • 25.0%Satisfactory
  • 12.5%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 50.0%Very good
  • 12.5%Good
  • 25.0%Satisfactory
  • 12.5%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 20.0%Very good
  • 20.0%Good
  • 60.0%Satisfactory
Find on map >>   Show street view

Structure Number: 3022,  Location: 1.2W OF HURON (Lat: 39.638231,  Lng: -95.372936),  Route carried "on" structure: County highway 26,  Year Built: 1930,  Year Reconstructed: 1954,  Status: Posted for load,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 56 (year 2007),  Average Future Daily Traffic: 95 (year 2040),  Design Load: HS 15,  Features Intersected: STREAM
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 1.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 27.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 16.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 1.83m (6.00ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Bridge Improvement Cost: $130,000,  Roadway Improvement Cost: $100,000,  Total Project Cost: $235,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 3024,  Location: 3.2E OF HURON (Lat: 39.638217,  Lng: -95.291108),  Route carried "on" structure: County highway 26,  Year Built: 1994,  Status: Open,  Structure Length: 2.80m (9.19ft),  Average Daily Traffic: 76 (year 2007),  Average Future Daily Traffic: 110 (year 2040),  Design Load: HS 20,  Features Intersected: INDEPENDENCE CREEK
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 1.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 69.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 70B42,  Location: 0.8N 2.3E OF EVEREST (Lat: 39.691619,  Lng: -95.377350),  Route carried "on" structure: County highway 1297,  Year Built: 2017,  Status: Open,  Structure Length: 2.90m (9.51ft),  Average Daily Traffic: 240 (year 2016),  Truck Traffic: 10%,  Average Future Daily Traffic: 300 (year 2042),  Design Load: HL 93,  Features Intersected: SOUTH FORK WOLF RIVER
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 28.5m (93.5ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 64.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 3102720354,  Location: 6.0N 0.2E OF EFFINGHAM (Lat: 39.609236,  Lng: -95.392033),  Route carried "on" structure: County highway ,  Year Built: 1999,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 80 (year 2007),  Average Future Daily Traffic: 120 (year 2040),  Design Load: HS 20,  Features Intersected: TRIB. LITTLE GRASSHOPPER,  Facility Carried by Structure: LOCAL RD. N-10.4
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 1.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 17.3m (56.8ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 90.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 62.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 3102720356,  Location: 5.0N 0.4E OF EFFINGHAM (Lat: 39.594756,  Lng: -95.394492),  Route carried "on" structure: County highway ,  Year Built: 1930,  Status: Posted for load,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 5 (year 2007),  Average Future Daily Traffic: 7 (year 2040),  Features Intersected: LITTLE GRASSHOPPER CREEK,  Facility Carried by Structure: LOCAL RD. M-10.4
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 1.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 3.6m (11.8ft),  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 5.5m (18.0ft),  Out-to-Out Width: 5.5m (18.0ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 8.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 5.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of replacement,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 4.02m (13.19ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Bridge Improvement Cost: $275,000,  Roadway Improvement Cost: $100,000,  Total Project Cost: $380,000,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 3102900354,  Location: 6.0N 1.3E OF EFFINGHAM (Lat: 39.608836,  Lng: -95.377622),  Route carried "on" structure: County highway 305,  Year Built: 1999,  Status: Open,  Structure Length: 2.68m (8.79ft),  Average Daily Traffic: 100 (year 2007),  Truck Traffic: 11%,  Average Future Daily Traffic: 150 (year 2040),  Design Load: HS 20,  Features Intersected: GRASSHOPPER CREEK,  Facility Carried by Structure: MINOR COL 11.2-N.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 1.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.5m (24.6ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.4m (34.1ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 66.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 31029003543,  Location: 5.7N 1.3E OF EFFINGHAM (Lat: 39.602981,  Lng: -95.377139),  Route carried "on" structure: County highway 305,  Year Built: 1935,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 20 (year 2007),  Average Future Daily Traffic: 30 (year 2040),  Features Intersected: TRIB. TO GRASSHOPPER CK.,  Facility Carried by Structure: MINOR COL 11.2-M.7
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 1.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 4.5m (14.8ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 4.9m (16.1ft),  Out-to-Out Width: 4.9m (16.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 63.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 7102990346,  Location: 0.5S 3.1E OF EVEREST (Lat: 39.667464,  Lng: -95.360911),  Route carried "on" structure: County highway ,  Year Built: 1991,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 45 (year 2016),  Average Future Daily Traffic: 49 (year 2042),  Design Load: H 20,  Features Intersected: UNNAMED STREAM,  Facility Carried by Structure: 110th St.
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 1.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.5m (24.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 62.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 999902000070631,  Location: 3.95 MI NE E JCT US 73 (Lat: 39.681944,  Lng: -95.368611),  Route carried "on" structure: State highway 20,  Year Built: 2014,  Status: Open,  Structure Length: 4.34m (14.24ft),  Average Daily Traffic: 220 (year 2020),  Truck Traffic: 20%,  Average Future Daily Traffic: 274 (year 2041),  Design Load: HL 93,  Features Intersected: SOUTH FORK WOLF RIVER
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 32.613,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.1m (56.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 58.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 14.26m (46.78ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 999902000220481,  Location: 3.07 MI E BROWN COLN (Lat: 39.674722,  Lng: -95.290556),  Route carried "on" structure: State highway 20,  Year Built: 2004,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 150 (year 2020),  Truck Traffic: 27%,  Average Future Daily Traffic: 187 (year 2041),  Design Load: HS 20,  Features Intersected: INDEPENDENCE CREEK DRG
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 4.973,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 17.0m (55.8ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Inventory Rating: 75.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 2.88m (9.45ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Discuss Huron, Kansas (KS) on our hugely popular Kansas forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.