Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Ken Caryl, Colorado (CO)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 22Number of bridges
  • 184ft / 56.1mTotal length
  • 326,992Total average daily traffic
  • 10,711Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Ken Caryl
  • No street view available for this location

New bridges in Ken Caryl, CO - historical statistics
  • New bridges - historical statistics
  • 41960-1969
  • 31970-1979
  • 111980-1989
  • 21990-1999
  • 12000-2009
  • 12010-2019
Average Bridge Daily Traffic in Ken Caryl, CO
Average Bridge Truck Traffic in Ken Caryl, CO
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 40.0%Good
  • 50.0%Satisfactory
  • 10.0%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 20.0%Very good
  • 40.0%Good
  • 40.0%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 80.0%Good
  • 20.0%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 21.4%Very good
  • 42.9%Good
  • 35.7%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 30.0%Good
  • 70.0%Satisfactory
Find on map >>   Show street view

Structure Number: F-15-65,  Location: 1.4 MI E OF PHILLIPSBURG (Lat: 39.544069,  Lng: -105.167689),  Route carried "on" structure: County highway ,  Year Built: 1969,  Status: Open,  Structure Length: 1.18m (3.87ft),  Average Daily Traffic: 2,820 (year 2021),  Truck Traffic: 25%,  Average Future Daily Traffic: 3,243 (year 2041),  Features Intersected: DEER CREEK,  Facility Carried by Structure: DEER CRK CANYON RD
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 7.586,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.1m (36.4ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: F-16-HZ,  Location: 2.0 MI S OF JCT SH 470 (Lat: 39.546261,  Lng: -105.088439),  Route carried "on" structure: State highway 121B,  Year Built: 1968,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 23,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 27,370 (year 2040),  Design Load: HS 20,  Features Intersected: DEER CREEK,  Facility Carried by Structure: SH 121 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.236,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 10 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft),  Out-to-Out Width: 116.8m (383.2ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: F-16-MA,  Location: 10.2 MI E - JCT I70 + SH (Lat: 39.578606,  Lng: -105.142125),  Route carried "on" structure: State highway 470A,  Year Built: 1987,  Status: Open,  Structure Length: 6.04m (19.82ft),  Average Daily Traffic: 29,000 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 39,150 (year 2040),  Features Intersected: KEN CARYL RD,  Facility Carried by Structure: SH 470 ML EBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.489,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.8m (97.8ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 58.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-MB,  Location: 10.2 MI S. OF I 70 (Lat: 39.578700,  Lng: -105.141897),  Route carried "on" structure: State highway 470A,  Year Built: 1987,  Status: Open,  Structure Length: 6.04m (19.82ft),  Average Daily Traffic: 29,000 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 39,150 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: KEN CARYL RD,  Facility Carried by Structure: SH 470 ML WBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.486,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.0m (98.4ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 58.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-MC,  Location: 12.4 MI S. OF I 70 (Lat: 39.560064,  Lng: -105.110358),  Route carried "on" structure: State highway 470A,  Year Built: 1986,  Status: Open,  Structure Length: 6.10m (20.01ft),  Average Daily Traffic: 24,500 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 33,565 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: KIPLING PARKWAY,  Facility Carried by Structure: SH 470 ML EBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.125,  Lanes on structure: 2,  Lanes under structure: 7,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.4m (103.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 59.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-MD,  Location: 12.4 MI S OF I 70 (Lat: 39.560272,  Lng: -105.110344),  Route carried "on" structure: State highway 470A,  Year Built: 1986,  Status: Open,  Structure Length: 6.10m (20.01ft),  Average Daily Traffic: 24,500 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 33,565 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: KIPLING PARKWAY,  Facility Carried by Structure: SH 470 ML WBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.125,  Lanes on structure: 2,  Lanes under structure: 7,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.3m (102.7ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 64.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-MG,  Location: 13.9 MI E - JCT SH 470 + (Lat: 39.553739,  Lng: -105.085497),  Route carried "on" structure: State highway 470A,  Year Built: 1987,  Status: Open,  Structure Length: 9.24m (30.31ft),  Average Daily Traffic: 30,500 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 41,480 (year 2040),  Design Load: HS 20,  Features Intersected: SH 121-WADSWORTH BLVD,  Facility Carried by Structure: SH 470 ML EBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.437,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 14 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 45.7m (149.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 99.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 59.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-MH,  Location: 3.2 MI W - JCT US 85 + SH (Lat: 39.553972,  Lng: -105.085397),  Route carried "on" structure: State highway 470A,  Year Built: 1987,  Status: Open,  Structure Length: 8.64m (28.35ft),  Average Daily Traffic: 30,500 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 41,480 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SH 121-WADSWORTH BLVD,  Facility Carried by Structure: SH 470 ML WBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.447,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 14 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 43.0m (141.1ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Inventory Rating: 60.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-ST,  Location: .1 MI N.OF JCT470&KIPLING (Lat: 39.561042,  Lng: -105.109744),  Route carried "on" structure: ServiceState highway 470A,  Year Built: 1987,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 49,000 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 67,130 (year 2040),  Design Load: HS 20,  Features Intersected: MASSEY DRAW AR,  Facility Carried by Structure: KIPLING PARKWAY AR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.074,  Lanes on structure: 7,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.2m (10.5ft),  Out-to-Out Width: 62.3m (204.4ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: G-15-11,  Location: 3.6 MI W OF SH75 (Lat: 39.547486,  Lng: -105.153267),  Route carried "on" structure: County highway ,  Year Built: 1978,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 554 (year 2021),  Average Future Daily Traffic: 637 (year 2041),  Features Intersected: DEER CREEK,  Facility Carried by Structure: GRIZZLY DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.024,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 62.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: G-15-63,  Location: 2.7 MI W OF SH75 (Lat: 39.549222,  Lng: -105.134700),  Route carried "on" structure: County highway ,  Year Built: 1969,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 889 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,022 (year 2041),  Features Intersected: DEER CREEK,  Facility Carried by Structure: COUGAR ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.263,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.0m (19.7ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 29.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 18.1 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: G-15-64,  Location: 2.5 MI E OF PHILLIPSBURG (Lat: 39.543161,  Lng: -105.162397),  Route carried "on" structure: County highway ,  Year Built: 1969,  Status: Open,  Structure Length: 1.25m (4.10ft),  Average Daily Traffic: 2,056 (year 2021),  Truck Traffic: 25%,  Average Future Daily Traffic: 2,364 (year 2041),  Features Intersected: DEER CREEK,  Facility Carried by Structure: DEER CRK CANYON RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.090,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.7m (38.4ft),  Curb-To-Curb Width: 10.0m (32.8ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 41.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: G-15-98,  Location: 3.2 MI W OF SH 75 (Lat: 39.551328,  Lng: -105.140611),  Route carried "on" structure: County highway ,  Year Built: 1975,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 3,081 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 3,543 (year 2041),  Features Intersected: DOCKMAN GULCH,  Facility Carried by Structure: DEER CRK CANYON RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.309,  Lanes on structure: 3,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.0m (16.4ft),  Out-to-Out Width: 24.3m (79.7ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2019
Find on map >>   Show street view

Structure Number: G-16-119,  Location: 1.5 MI S OF KEY CARYL AVE (Lat: 39.557417,  Lng: -105.150281),  Route carried "on" structure: County highway ,  Year Built: 1975,  Status: Open,  Structure Length: 0.66m (2.17ft),  Average Daily Traffic: 1,801 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 2,071 (year 2041),  Features Intersected: DEER CREEK TRIBUTARY,  Facility Carried by Structure: SOUTH VALLEY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.024,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.4m (27.6ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft),  Out-to-Out Width: 21.1m (69.2ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: H-15-1,  Location: JUST NORTH OF UTE AVENUE (Lat: 39.558469,  Lng: -105.092278),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 0.63m (2.07ft),  Average Daily Traffic: 1,062 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,221 (year 2041),  Features Intersected: MASSEY DRAW,  Facility Carried by Structure: CARR STREET
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 0.553,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 0.0m,  Out-to-Out Width: 66.6m (218.5ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: H-15-105,  Location: .1 MI SO OF CHATFIELD (Lat: 39.564283,  Lng: -105.092231),  Route carried "on" structure: County highway ,  Year Built: 1985,  Status: Open,  Structure Length: 1.53m (5.02ft),  Average Daily Traffic: 1,189 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,367 (year 2041),  Features Intersected: LOCAL DRAINAGE,  Facility Carried by Structure: CARR STREET
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 1.181,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 2.8m (9.2ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: H-15-107,  Location: 0.5 mi W. of Wadsworth (Lat: 39.566208,  Lng: -105.095356),  Route carried "on" structure: County highway ,  Year Built: 2010,  Status: Open,  Structure Length: 0.63m (2.07ft),  Average Daily Traffic: 9,714 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 11,172 (year 2041),  Features Intersected: WILLOW CREEK,  Facility Carried by Structure: W. CHATFIELD AVE
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 0.002,  Lanes on structure: 5,  Owner: County Highway Agency,  Approaching Roadway Width: 21.2m (69.6ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.3m (20.7ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 2.3m (7.5ft),  Out-to-Out Width: 30.8m (101.0ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: H-16-102,  Location: .1 MI E OF GARRISON (Lat: 39.580778,  Lng: -105.097944),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 12,694 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 14,598 (year 2041),  Design Load: HS 20,  Features Intersected: MASSEY DRAW,  Facility Carried by Structure: KEN CARYL AVE
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 6.011,  Lanes on structure: 6,  Owner: County Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 24 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.9m (12.8ft),  Curb or Sidewalk Widths: Left: 2.6m (8.5ft),  Right: 2.6m (8.5ft),  Out-to-Out Width: 37.2m (122.0ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 38.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: H-16-103,  Location: JUST S OF KEN CARYL (Lat: 39.580453,  Lng: -105.097064),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 142 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 164 (year 2041),  Design Load: HS 20,  Features Intersected: MASSEY DRAW,  Facility Carried by Structure: ESTES COURT
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 0.308,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.7m (8.9ft),  Out-to-Out Width: 23.0m (75.5ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 43.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: H-16-105,  Location: .2 MI S OF KEN CARYL ROAD (Lat: 39.578928,  Lng: -105.091436),  Route carried "on" structure: County highway ,  Year Built: 1980,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 2,990 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,439 (year 2041),  Features Intersected: MASSEY DRAW,  Facility Carried by Structure: CARR STREET
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 1.415,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: F-16-MG,  Location: 13.9 MI E - JCT SH 470 + (Lat: 39.553739,  Lng: -105.085497),  Route carried "under" structure: State highway 121A,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 24,000 (year 2011),  Truck Traffic: 3%,  Features Intersected: SH 121-WADSWORTH BLVD,  Facility Carried by Structure: SH 470 ML EBND
Minimum Vertical Clearance: 6.94m (22.77ft),  Kilometerpoint: 0.016,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 45.7m (149.9ft)

Find on map >>   Show street view

Structure Number: F-16-MH,  Location: 3.2 MI W - JCT US 85 + SH (Lat: 39.553972,  Lng: -105.085397),  Route carried "under" structure: State highway 121A,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 24,000 (year 2011),  Truck Traffic: 3%,  Features Intersected: SH 121-WADSWORTH BLVD,  Facility Carried by Structure: SH 470 ML WBND
Minimum Vertical Clearance: 5.49m (18.01ft),  Kilometerpoint: 0.032,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 43.0m (141.1ft)

Discuss Ken Caryl, Colorado (CO) on our hugely popular Colorado forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.