Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Palos Park, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 13Number of bridges
  • 115ft / 35.2mTotal length
  • 112,700Total average daily traffic
  • 4,472Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Palos Park
  • No street view available for this location

New bridges in Palos Park, IL - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 11940-1949
  • 11960-1969
  • 11980-1989
  • 61990-1999
  • 12000-2009
  • 12010-2019
Reconstructed bridges in Palos Park, IL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11990-1999
  • 12000-2009
Average Bridge Daily Traffic in Palos Park, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 12.5%Very good
  • 62.5%Good
  • 12.5%Satisfactory
  • 12.5%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 25.0%Very good
  • 50.0%Good
  • 12.5%Fair
  • 12.5%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 37.5%Very good
  • 50.0%Good
  • 12.5%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 40.0%Good
  • 60.0%Satisfactory
Find on map >>   Show street view

Structure Number: 160567,  Location: 1.7 M E US 45 (Lat: 41.667508,  Lng: -87.821969),  Route carried "on" structure: Other road ,  Year Built: 1943,  Year Reconstructed: 1996,  Status: Open,  Structure Length: 5.70m (18.70ft),  Average Daily Traffic: 6,850 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 6,592 (year 2032),  Design Load: HS 20,  Features Intersected: RR - METRA,  Facility Carried by Structure: 123RD ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.111,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.6m (70.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 81.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 162527,  Location: 0.2 M W OF IL 7 (Lat: 41.676708,  Lng: -87.819114),  Route carried "on" structure: State highway 83,  Year Built: 1985,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 9,850 (year 2021),  Truck Traffic: 10%,  Average Future Daily Traffic: 14,832 (year 2032),  Features Intersected: CREEK W OF IL 7
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 40.168,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 80.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 47.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2018,  Deck Structure Type: Other
Find on map >>   Show street view

Structure Number: 162611,  Location: 0.9 M E US 45 (Lat: 41.652653,  Lng: -87.836844),  Route carried "on" structure: Other road ,  Year Built: 1995,  Status: Open,  Structure Length: 5.49m (18.01ft),  Average Daily Traffic: 6,900 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 12,154 (year 2032),  Design Load: HS 20,  Features Intersected: RR - METRA,  Facility Carried by Structure: 131ST ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.713,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.2m (76.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Very good,  Operating Rating: 64.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 162635,  Location: 1 M SW IL 83 (Lat: 41.666311,  Lng: -87.830389),  Route carried "on" structure: Other road ,  Year Built: 1994,  Status: Open,  Structure Length: 2.50m (8.20ft),  Average Daily Traffic: 2,750 (year 2018),  Truck Traffic: 4%,  Average Future Daily Traffic: 2,369 (year 2032),  Features Intersected: IL 7 (W HWY),  Facility Carried by Structure: 86TH AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.738,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 24.5m (80.4ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 85.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 162636,  Location: 0.9 M SW IL 83 (Lat: 41.667381,  Lng: -87.828958),  Route carried "on" structure: Other road ,  Year Built: 1996,  Status: Open,  Structure Length: 2.84m (9.32ft),  Average Daily Traffic: 6,850 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 6,592 (year 2032),  Design Load: HS 20,  Features Intersected: IL 7 (SW HWY),  Facility Carried by Structure: 123RD ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.516,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 27.8m (91.2ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.8m (58.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 81.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 162667,  Location: 1.4 M W US 45 (Lat: 41.686914,  Lng: -87.881881),  Route carried "on" structure: State highway 83,  Year Built: 1999,  Status: Open,  Structure Length: 1.86m (6.10ft),  Average Daily Traffic: 12,400 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 13,493 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: CREEK W OF 104TH AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 45.736,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.8m (58.4ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 73.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 162769,  Location: 0.4 M S OF IL 83 (Lat: 41.676644,  Lng: -87.844075),  Route carried "on" structure: Other road ,  Year Built: 2002,  Status: Open,  Structure Length: 1.62m (5.31ft),  Average Daily Traffic: 275 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 206 (year 2032),  Features Intersected: MILL CREEK,  Facility Carried by Structure: KEAN AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.724,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.2m (30.2ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.3m (50.2ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 67.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 162831,  Location: 0.6 M E US 45 (Lat: 41.674339,  Lng: -87.842969),  Route carried "on" structure: Other road ,  Year Built: 2012,  Status: Open,  Structure Length: 2.19m (7.19ft),  Average Daily Traffic: 975 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 2,150 (year 2036),  Features Intersected: MILL CREEK,  Facility Carried by Structure: 119TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.998,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.2m (69.6ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 73.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 163018,  Location: 0.5 M S 107TH P19 (Lat: 41.688228,  Lng: -87.874853),  Route carried "on" structure: Other road ,  Year Built: 1964,  Year Reconstructed: 2014,  Status: Open,  Structure Length: 12.37m (40.58ft),  Average Daily Traffic: 9,700 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 8,549 (year 2032),  Design Load: H 20,  Features Intersected: CAL SAG CHANNEL,  Facility Carried by Structure: 104TH AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.095,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Navigation Control: Yes ( Vertical Clearance: 7.3m (24.0ft), Horizontal Clearance: 68.6m (225.1ft)),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 4,  Length of Maximum Span: 88.4m (290.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 13.7m (44.9ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 51.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Critical Feature Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Cathodic Protection
Find on map >>   Show street view

Structure Number: 162635,  Location: 1 M SW IL 83 (Lat: 41.666311,  Lng: -87.830389),  Route carried "under" structure: State highway 7,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 16,300 (year 2021),  Truck Traffic: 2%,  Features Intersected: IL 7 (W HWY),  Facility Carried by Structure: 86TH AVENUE
Minimum Vertical Clearance: 4.45m (14.60ft),  Kilometerpoint: 40.603,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.5m (80.4ft)

Find on map >>   Show street view

Structure Number: 162636,  Location: 0.9 M SW IL 83 (Lat: 41.667381,  Lng: -87.828958),  Route carried "under" structure: State highway 7,  Year Built: 1996,  Structure Length: 0. m,  Average Daily Traffic: 16,300 (year 2021),  Truck Traffic: 2%,  Features Intersected: IL 7 (SW HWY),  Facility Carried by Structure: 123RD ST
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 40.780,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.8m (91.2ft)

Find on map >>   Show street view

Structure Number: 162677,  Location: 0.3 M N of 131st (Lat: 41.656833,  Lng: -87.838850),  Route carried "under" structure: State highway 7,  Structure Length: 0. m,  Average Daily Traffic: 16,300 (year 2021),  Truck Traffic: 2%,  Features Intersected: IL 7 SOUTHWEST HWY,  Facility Carried by Structure: PEDESTRIAN BRIDGE
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 39.283,  Lanes under structure: 4,  Material/Design: Wood or Timber,  Design/Construction: Truss - Deck,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 163022,  Location: AT 120TH P19 (Lat: 41.672969,  Lng: -87.816097),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 7,250 (year 2018),  Truck Traffic: 4%,  Features Intersected: 80TH AVE,  Facility Carried by Structure: N&W RR
Minimum Vertical Clearance: 3.63m (11.91ft),  Kilometerpoint: 0.193,  Lanes under structure: 2,  Material/Design: Steel,  Length of Maximum Span: 9.8m (32.2ft)

Discuss Palos Park, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.