Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Pocahontas, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 21Number of bridges
  • 344ft / 105mTotal length
  • $302,000Total costs
  • 168,575Total average daily traffic
  • 64,901Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Pocahontas
  • No street view available for this location

New bridges in Pocahontas, IL - historical statistics
  • New bridges - historical statistics
  • 21900-1909
  • 11910-1919
  • 11920-1929
  • 11940-1949
  • 121960-1969
  • 21990-1999
  • 22010-2019
Average Bridge Daily Traffic in Pocahontas, IL
Average Bridge Truck Traffic in Pocahontas, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 25.0%Very good
  • 12.5%Good
  • 25.0%Satisfactory
  • 31.3%Fair
  • 6.3%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 12.5%Very good
  • 50.0%Good
  • 12.5%Satisfactory
  • 25.0%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 18.8%Very good
  • 62.5%Good
  • 12.5%Satisfactory
  • 6.3%Serious
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 41.7%Very good
  • 8.3%Good
  • 33.3%Satisfactory
  • 8.3%Fair
  • 8.3%Poor
Find on map >>   Show street view

Structure Number: 30001,  Location: 2.1 MI E POCAHONTAS (Lat: 38.834661,  Lng: -89.508608),  Route carried "on" structure: Interstate 70,  Year Built: 1967,  Status: Open,  Structure Length: 3.63m (11.91ft),  Average Daily Traffic: 13,400 (year 2021),  Truck Traffic: 41%,  Average Future Daily Traffic: 10,836 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: W BR SHOAL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 67.864,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 30002,  Location: 2.1 MI E POCAHONTAS (Lat: 38.834733,  Lng: -89.508444),  Route carried "on" structure: Interstate 70,  Year Built: 1967,  Status: Open,  Structure Length: 3.63m (11.91ft),  Average Daily Traffic: 13,400 (year 2021),  Truck Traffic: 41%,  Average Future Daily Traffic: 10,836 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: W BR SHOAL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 67.880,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 30003,  Location: 2.3 MI E POCAHONTAS (Lat: 38.836103,  Lng: -89.505353),  Route carried "on" structure: Interstate 70,  Year Built: 1967,  Status: Open,  Structure Length: 12.98m (42.59ft),  Average Daily Traffic: 13,400 (year 2021),  Truck Traffic: 41%,  Average Future Daily Traffic: 10,836 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: MID FK SHOAL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 68.186,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 40.5m (132.9ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 47.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 28.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 30004,  Location: 2.3 MI E POCAHONTAS (Lat: 38.836169,  Lng: -89.505200),  Route carried "on" structure: Interstate 70,  Year Built: 1967,  Status: Open,  Structure Length: 12.98m (42.59ft),  Average Daily Traffic: 13,400 (year 2021),  Truck Traffic: 41%,  Average Future Daily Traffic: 10,836 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: MID FK SHOAL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 68.202,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 40.5m (132.9ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 47.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 28.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 30005,  Location: 2.7 MI E POCAHONTAS (Lat: 38.838628,  Lng: -89.499656),  Route carried "on" structure: Interstate 70,  Year Built: 1967,  Status: Open,  Structure Length: 7.47m (24.51ft),  Average Daily Traffic: 13,400 (year 2021),  Truck Traffic: 41%,  Average Future Daily Traffic: 10,836 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: E FORK SHOAL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 68.749,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 30006,  Location: 2.7 MI E POCAHONTAS (Lat: 38.838700,  Lng: -89.499492),  Route carried "on" structure: Interstate 70,  Year Built: 1967,  Status: Open,  Structure Length: 7.47m (24.51ft),  Average Daily Traffic: 13,400 (year 2021),  Truck Traffic: 41%,  Average Future Daily Traffic: 10,836 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: E FORK SHOAL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 68.765,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Other Special Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 30015,  Location: AT POCAHONTAS (Lat: 38.831803,  Lng: -89.545586),  Route carried "on" structure: County highway ,  Year Built: 1966,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 7.44m (24.41ft),  Average Daily Traffic: 1,300 (year 2020),  Truck Traffic: 11%,  Average Future Daily Traffic: 1,420 (year 2032),  Design Load: HS 20,  Features Intersected: FAI 70 EB & WB,  Facility Carried by Structure: US 40 / POKEY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.276,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 32 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 22.3m (73.2ft),  Curb-To-Curb Width: 11.4m (37.4ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Poor,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 59.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 30016,  Location: 1.6 MI E POCAHONTAS (Lat: 38.832550,  Lng: -89.516092),  Route carried "on" structure: US 40,  Year Built: 1966,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 8.75m (28.71ft),  Average Daily Traffic: 1,100 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,262 (year 2032),  Design Load: HS 20,  Features Intersected: FAI 70 EB & WB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 66.657,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 26.2m (86.0ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 72.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 30038,  Location: 0.1 MI W POCAHONTAS (Lat: 38.824317,  Lng: -89.548950),  Route carried "on" structure: County highway ,  Year Built: 1912,  Status: Posted for load,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 600 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 526 (year 2032),  Features Intersected: E Trib to Shoal Crk,  Facility Carried by Structure: State Street SBI 1
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.336,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Concrete,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 5.9m (19.4ft),  Out-to-Out Width: 7.1m (23.3ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 33.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 20.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 1.07m (3.51ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: Febuary 2022,  Bridge Improvement Cost: $41,000,  Roadway Improvement Cost: $4,000,  Total Project Cost: $45,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 30043,  Location: 3.2 MI E POCAHONTAS (Lat: 38.842239,  Lng: -89.491519),  Route carried "on" structure: County highway ,  Year Built: 1966,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 6.84m (22.44ft),  Average Daily Traffic: 125 (year 2020),  Truck Traffic: 18%,  Average Future Daily Traffic: 210 (year 2032),  Design Load: HS 15,  Features Intersected: FAI 70,  Facility Carried by Structure: TR 112-SUGARLOAF R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.032,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.5m (67.3ft),  Curb-To-Curb Width: 8.1m (26.6ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 55.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 30058,  Location: 1.9 MI E POCAHONTAS (Lat: 38.836556,  Lng: -89.505839),  Route carried "on" structure: US 40,  Year Built: 1994,  Status: Open,  Structure Length: 13.41m (44.00ft),  Average Daily Traffic: 1,100 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,262 (year 2032),  Design Load: HS 20,  Features Intersected: SHOAL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 67.703,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 39.6m (129.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 63.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 30059,  Location: 1.9 MI E POCAHONTAS (Lat: 38.839269,  Lng: -89.499803),  Route carried "on" structure: US 40,  Year Built: 1993,  Status: Open,  Structure Length: 7.61m (24.97ft),  Average Daily Traffic: 1,100 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,262 (year 2032),  Design Load: HS 20,  Features Intersected: E Fork SHOAL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 68.315,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 38.1m (125.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 74.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 30063,  Location: 1.7 MI E Pocahontas (Lat: 38.835281,  Lng: -89.508644),  Route carried "on" structure: US 40,  Year Built: 2017,  Status: Open,  Structure Length: 3.29m (10.79ft),  Average Daily Traffic: 1,100 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,262 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: W Fork Shoal Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 67.430,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 31.8m (104.3ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 71.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 54.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 33053,  Location: 1.5 Mi N Pocahontas (Lat: 38.849697,  Lng: -89.547711),  Route carried "on" structure: County highway ,  Year Built: 2013,  Status: Open,  Structure Length: 3.66m (12.01ft),  Average Daily Traffic: 1,300 (year 2020),  Truck Traffic: 11%,  Average Future Daily Traffic: 1,800 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: Trib. to Shoal Ck,  Facility Carried by Structure: FAS779 Pokey Rd CH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.281,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 341,  Location: POCAHONTAS (Lat: 38.826272,  Lng: -89.548075),  Route carried "on" structure: City street ,  Year Built: 1920,  Status: Open,  Structure Length: 0.69m (2.26ft),  Average Daily Traffic: 50 (year 2020),  Truck Traffic: 60%,  Average Future Daily Traffic: 237 (year 2032),  Features Intersected: TRIB OF SHOAL CK,  Facility Carried by Structure: RUSSEL ST MSS 1034
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.177,  Lanes on structure: 1,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.9m (22.6ft),  Curb-To-Curb Width: 3.9m (12.8ft),  Out-to-Out Width: 4.9m (16.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Serious,  Channel: Poor,  Operating Rating: 45.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 26.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 0.70m (2.30ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Bridge Improvement Cost: $28,000,  Roadway Improvement Cost: $3,000,  Total Project Cost: $31,000,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 39906,  Location: 0.35 M S OF STATE ST (Lat: 38.823139,  Lng: -89.535906),  Route carried "on" structure: City street ,  Year Built: 1901,  Status: Open,  Structure Length: 4.02m (13.19ft),  Average Daily Traffic: 200 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 158 (year 2032),  Features Intersected: CONRAIL RR,  Facility Carried by Structure: MSS 6130
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.628,  Lanes on structure: 2,  Owner: Railroad,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.2m (53.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of replacement,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 4.02m (13.19ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Bridge Improvement Cost: $205,000,  Roadway Improvement Cost: $21,000,  Total Project Cost: $226,000
Find on map >>   Show street view

Structure Number: 30015,  Location: AT POCAHONTAS (Lat: 38.831539,  Lng: -89.545569),  Route carried "under" structure: Interstate 70,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 25,500 (year 2021),  Truck Traffic: 36%,  Features Intersected: FAI 70 EB & WB,  Facility Carried by Structure: US 40 / POKEY ROAD
Minimum Vertical Clearance: 5.56m (18.24ft),  Kilometerpoint: 64.501,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.3m (73.2ft)

Find on map >>   Show street view

Structure Number: 30016,  Location: 1.6 MI E POCAHONTAS (Lat: 38.832550,  Lng: -89.516092),  Route carried "under" structure: Interstate 70,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 26,800 (year 2021),  Truck Traffic: 41%,  Features Intersected: FAI 70 EB & WB,  Facility Carried by Structure: US 40/FAS 779
Minimum Vertical Clearance: 5.72m (18.77ft),  Kilometerpoint: 67.172,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.2m (86.0ft)

Find on map >>   Show street view

Structure Number: 30043,  Location: 3.2 MI E POCAHONTAS (Lat: 38.842239,  Lng: -89.491519),  Route carried "under" structure: Interstate 70,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 26,800 (year 2021),  Truck Traffic: 41%,  Features Intersected: FAI 70,  Facility Carried by Structure: TR 112-SUGARLOAF R
Minimum Vertical Clearance: 5.31m (17.42ft),  Kilometerpoint: 69.554,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.5m (67.3ft)

Find on map >>   Show street view

Structure Number: 399,  Location: 1.09M S US 40 (Lat: 38.821583,  Lng: -89.540508),  Route carried "under" structure: County highway ,  Year Built: 1943,  Structure Length: 0. m,  Average Daily Traffic: 1,000 (year 2020),  Truck Traffic: 7%,  Features Intersected: FAS 781/ACADEMY ST,  Facility Carried by Structure: CONSL RR
Minimum Vertical Clearance: 4.24m (13.91ft),  Kilometerpoint: 0.869,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 11.0m (36.1ft)

Find on map >>   Show street view

Structure Number: 39903,  Location: 2.75 M NE POCAHONTAS (Lat: 38.838028,  Lng: -89.490561),  Route carried "under" structure: County highway ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 100 (year 2020),  Truck Traffic: 13%,  Features Intersected: TR 112,  Facility Carried by Structure: CONRAIL RR
Minimum Vertical Clearance: 4.01m (13.16ft),  Kilometerpoint: 0.628,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 9.8m (32.2ft)

Discuss Pocahontas, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.