Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Rustburg, Virginia (VA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 11Number of bridges
  • 62ft / 18.5mTotal length
  • $503,000Total costs
  • 11,879Total average daily traffic
  • 328Total average daily truck traffic
  • 15,808Total future (year 2040) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Rustburg
  • No street view available for this location

New bridges in Rustburg, VA - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 31950-1959
  • 11960-1969
  • 21970-1979
  • 21990-1999
  • 12000-2009
  • 12010-2019
Reconstructed bridges in Rustburg, VA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11990-1999
  • 22000-2009
Average Bridge Daily Traffic in Rustburg, VA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 33.3%Very good
  • 33.3%Good
  • 22.2%Satisfactory
  • 11.1%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 33.3%Very good
  • 33.3%Good
  • 22.2%Satisfactory
  • 11.1%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 55.6%Good
  • 44.4%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 9.1%Very good
  • 27.3%Good
  • 54.5%Satisfactory
  • 9.1%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Good
  • 50.0%Fair
Find on map >>   Show street view

Structure Number: 4193,  Location: 0.25-Rt.916 / 3.32-Rt.24 (Lat: 37.321167,  Lng: -79.104111),  Route carried "on" structure: US 501,  Year Built: 1936,  Status: Open,  Structure Length: 3.89m (12.76ft),  Average Daily Traffic: 3,914 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 5,480 (year 2040),  Features Intersected: Beaver Creek,  Facility Carried by Structure: Campbell Highway
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 106.831,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.0m (42.7ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 421,  Location: 1.49-Rt 615 / 1.30-Rt 501 (Lat: 37.213786,  Lng: -79.070664),  Route carried "on" structure: County highway 607,  Year Built: 1950,  Status: Posted for load,  Structure Length: 1.29m (4.23ft),  Average Daily Traffic: 329 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 362 (year 2040),  Features Intersected: Mollys Creek,  Facility Carried by Structure: Winfall Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.438,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 4.0m (13.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.8m (35.4ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 4.9m (16.1ft),  Out-to-Out Width: 5.2m (17.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 18.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 10.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Length Of Structure Improvement: 1.92m (6.30ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: October 2021,  Bridge Improvement Cost: $335,000,  Roadway Improvement Cost: $34,000,  Total Project Cost: $503,000 ( Estimate for 2015),  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4262,  Location: 0.70-Rt. 606/1.75-Rt.731 (Lat: 37.253233,  Lng: -79.026458),  Route carried "on" structure: County highway 651,  Year Built: 1973,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 508 (year 2019),  Average Future Daily Traffic: 721 (year 2040),  Design Load: HS 20,  Features Intersected: Button Creek,  Facility Carried by Structure: Bear Creek Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.016,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 69.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: 4264,  Location: 2.00-Rt 501 / 0.50-Rt 650 (Lat: 37.193847,  Lng: -79.058053),  Route carried "on" structure: County highway 654,  Year Built: 1971,  Year Reconstructed: 2012,  Status: Open,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 249 (year 2019),  Average Future Daily Traffic: 310 (year 2040),  Design Load: HS 20,  Features Intersected: Mollys Creek,  Facility Carried by Structure: Marshall Mill Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.218,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 7.8m (25.6ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 93.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 72.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4291,  Location: .01-Rt 501 / .59-Rt 930 (Lat: 37.306753,  Lng: -79.109472),  Route carried "on" structure: Alternate County highway 680,  Year Built: 1965,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 1,383 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,638 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: Tussocky Creek,  Facility Carried by Structure: Suburban Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.133,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 81.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 62.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 4305,  Location: 2.10-Rt.24 / 1.00-Rt.686 (Lat: 37.231619,  Lng: -79.166675),  Route carried "on" structure: County highway 687,  Year Built: 1957,  Year Reconstructed: 1996,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 265 (year 2019),  Average Future Daily Traffic: 293 (year 2040),  Features Intersected: Br. of Little Seneca Ck.,  Facility Carried by Structure: Gough Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.603,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 4.3m (14.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 5.5m (18.0ft),  Out-to-Out Width: 6.1m (20.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4322,  Location: 0.60 Rt 727 / 1.00 Rt 751 (Lat: 37.192533,  Lng: -79.125042),  Route carried "on" structure: County highway 701,  Year Built: 1959,  Status: Open,  Structure Length: 3.04m (9.97ft),  Average Daily Traffic: 277 (year 2016),  Average Future Daily Traffic: 310 (year 2040),  Features Intersected: Seneca River,  Facility Carried by Structure: East Ferry Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.800,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.8m (19.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.2m (30.2ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.8m (28.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 23033,  Location: 0.55-Rt.916/1.05-Rt.680 (Lat: 37.321033,  Lng: -79.104297),  Route carried "on" structure: US 501,  Year Built: 1991,  Status: Open,  Structure Length: 3.35m (10.99ft),  Average Daily Traffic: 3,914 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 5,480 (year 2040),  Features Intersected: Beaver Creek,  Facility Carried by Structure: Campbell Hwy SBL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 102.702,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 31.2m (102.4ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 72.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 55.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 25646,  Location: 1.20-Rt 670 / 0.20-Rt 680 (Lat: 37.307236,  Lng: -79.127911),  Route carried "on" structure: County highway 669,  Year Built: 1998,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 212 (year 2019),  Average Future Daily Traffic: 301 (year 2040),  Design Load: HS 20,  Features Intersected: Beaver Creek,  Facility Carried by Structure: Dodson Drive
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.360,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020
Find on map >>   Show street view

Structure Number: 27853,  Location: 0.50 TO 751 - 0.41 TO 687 (Lat: 37.219864,  Lng: -79.156931),  Route carried "on" structure: County highway 686,  Year Built: 2007,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 452 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 497 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: Seneca Creek,  Facility Carried by Structure: Browns Mill Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.717,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.4m (34.1ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 56.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 30406,  Location: 0.78-Rt.651/1.15-Rt.615 (Lat: 37.276764,  Lng: -79.063981),  Route carried "on" structure: County highway 663,  Year Built: 2015,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 376 (year 2019),  Average Future Daily Traffic: 416 (year 2040),  Design Load: HL 93,  Features Intersected: Button Creek,  Facility Carried by Structure: Bethany Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.947,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb-To-Curb Width: 6.8m (22.3ft),  Out-to-Out Width: 7.1m (23.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 64.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Discuss Rustburg, Virginia (VA) on our hugely popular Virginia forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.