Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Santaquin, Utah (UT)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 22Number of bridges
  • 128ft / 38.8mTotal length
  • 258,140Total average daily traffic
  • 54,628Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Santaquin
  • No street view available for this location

New bridges in Santaquin, UT - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 61960-1969
  • 41970-1979
  • 41980-1989
  • 41990-1999
  • 32000-2009
Average Bridge Daily Traffic in Santaquin, UT
Average Bridge Truck Traffic in Santaquin, UT
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 13.3%Good
  • 80.0%Satisfactory
  • 6.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 6.7%Very good
  • 20.0%Good
  • 60.0%Satisfactory
  • 13.3%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 6.7%Very good
  • 33.3%Good
  • 40.0%Satisfactory
  • 20.0%Fair
Find on map >>   Show street view

Structure Number: 49052D,  Location: 12900 S. 6250 W., SNTQUN. (Lat: 39.994475,  Lng: -111.802817),  Route carried "on" structure: County highway ,  Year Built: 2003,  Status: Open,  Structure Length: 0.68m (2.23ft),  Average Daily Traffic: 19 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 24 (year 2040),  Design Load: HL 93,  Features Intersected: HIGHLAND CANAL,  Facility Carried by Structure: CO.RD,6250 WEST ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.205,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.2m (20.3ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 47.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 49053D,  Location: 12875 S.6000 W.,N.OF STQN (Lat: 39.995350,  Lng: -111.797136),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Open,  Structure Length: 0.68m (2.23ft),  Average Daily Traffic: 26 (year 2020),  Average Future Daily Traffic: 32 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: HIGHLINE CANAL,  Facility Carried by Structure: CO.RD.,6000 W.ST.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.387,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.6m (41.3ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.2m (20.3ft),  Curb-To-Curb Width: 12.6m (41.3ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 31.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 20.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 49054D,  Location: 12875 S.5950 W.,N.OF STQN (Lat: 39.995825,  Lng: -111.794067),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Open,  Structure Length: 0.68m (2.23ft),  Average Daily Traffic: 63 (year 2020),  Average Future Daily Traffic: 77 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: HIGHLINE CANAL,  Facility Carried by Structure: CO.RD.,5950 SO.ST.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.022,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.6m (41.3ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.2m (20.3ft),  Curb-To-Curb Width: 12.6m (41.3ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 49056C,  Location: 1180 N. 200 E., SANTAQUIN (Lat: 39.994753,  Lng: -111.780761),  Route carried "on" structure: City street ,  Year Built: 1925,  Status: Posted for load,  Structure Length: 0.83m (2.72ft),  Average Daily Traffic: 53 (year 2020),  Average Future Daily Traffic: 65 (year 2040),  Design Load: HL 93,  Features Intersected: HIGHLINE CANAL,  Facility Carried by Structure: 200 EAST STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.769,  Lanes on structure: 1,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.8m (25.6ft),  Curb-To-Curb Width: 4.9m (16.1ft),  Out-to-Out Width: 4.9m (16.1ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 8.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 0.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 49057D,  Location: 12950 S.5200 W.,N.OF STQN (Lat: 39.993700,  Lng: -111.776986),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Posted for load,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 222 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 270 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: HIGHLINE CANAL,  Facility Carried by Structure: CO.RD.,5200 W.ST.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.012,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.6m (41.3ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.9m (22.6ft),  Curb-To-Curb Width: 12.6m (41.3ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 37.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 49058C,  Location: 13300 S.4800 W.,N.SNTQUIN (Lat: 39.987750,  Lng: -111.767478),  Route carried "on" structure: County highway ,  Year Built: 1990,  Status: Open,  Structure Length: 1.23m (4.04ft),  Average Daily Traffic: 158 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 192 (year 2040),  Design Load: HL 93,  Features Intersected: HIGHLINE CANAL,  Facility Carried by Structure: CO.RD.4800 WEST ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.551,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.2m (23.6ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.3m (37.1ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 7.2m (23.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 18.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 13.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 49093F,  Location: SUMMIT RIDGE S. OF SANTAQ (Lat: 39.949867,  Lng: -111.816397),  Route carried "on" structure: City street 2871,  Year Built: 2007,  Status: Open,  Structure Length: 4.61m (15.12ft),  Average Daily Traffic: 1,000 (year 2020),  Average Future Daily Traffic: 1,250 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: UNION PACIFIC RAILROAD,  Facility Carried by Structure: SUMMIT RIDGE PKWY.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.331,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 26.5m (86.9ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 45.6m (149.6ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: D 749,  Location: 2.1 MI NO OF SANTAQUIN (Lat: 40.004669,  Lng: -111.763000),  Route carried "on" structure: County highway 2854,  Year Built: 1967,  Status: Open,  Structure Length: 5.81m (19.06ft),  Average Daily Traffic: 2,013 (year 2020),  Average Future Daily Traffic: 2,516 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I-15 (SR-15) NBL & S,  Facility Carried by Structure: 12400 South
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.888,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.3m (69.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.0m (29.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 34.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: F 722,  Location: 1.1 MI. WEST OF SANTAQUIN (Lat: 39.980622,  Lng: -111.803900),  Route carried "on" structure: US 6,  Year Built: 2005,  Status: Open,  Structure Length: 3.06m (10.04ft),  Average Daily Traffic: 4,446 (year 2020),  Truck Traffic: 26%,  Average Future Daily Traffic: 5,558 (year 2040),  Design Load: HL 93,  Features Intersected: UNION PACIFIC RAILROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 255.553,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.7m (97.4ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 33.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1C 763,  Location: SW.SIDE OF SANTAQUIN (Lat: 39.965683,  Lng: -111.785197),  Route carried "on" structure: Interstate 15,  Year Built: 1989,  Status: Open,  Structure Length: 2.85m (9.35ft),  Average Daily Traffic: 29,829 (year 2020),  Truck Traffic: 23%,  Average Future Daily Traffic: 37,286 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SANTAQUIN CANYON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 392.953,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 27.4m (89.9ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 69.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 56.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1F 128,  Location: SANTAQUIN INTERCHANGE (Lat: 39.975336,  Lng: -111.772417),  Route carried "on" structure: Interstate 15,  Year Built: 1967,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 4.18m (13.71ft),  Average Daily Traffic: 29,829 (year 2020),  Truck Traffic: 23%,  Average Future Daily Traffic: 37,286 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US-6 (SR-6), INT. X-ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 394.484,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 12.1m (39.7ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 38.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 25.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1F 197,  Location: SO.SANTAQUIN INTERCHANGE (Lat: 39.950400,  Lng: -111.802653),  Route carried "on" structure: Interstate 15,  Year Built: 1973,  Status: Open,  Structure Length: 3.19m (10.47ft),  Average Daily Traffic: 27,142 (year 2020),  Truck Traffic: 25%,  Average Future Daily Traffic: 33,928 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: COUNTY RD.INT.X-ROAD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 390.682,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 31.1m (102.0ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 35.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 3C 763,  Location: SW SIDE OF SANTAQUIN (Lat: 39.966239,  Lng: -111.784903),  Route carried "on" structure: Interstate 15,  Year Built: 1989,  Status: Open,  Structure Length: 2.85m (9.35ft),  Average Daily Traffic: 29,829 (year 2020),  Truck Traffic: 23%,  Average Future Daily Traffic: 37,286 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SANTAQUIN CANYON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 392.835,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 27.4m (89.9ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 71.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 48.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3F 128,  Location: SANTAQUIN INTERCHANGE (Lat: 39.975789,  Lng: -111.772367),  Route carried "on" structure: Interstate 15,  Year Built: 1967,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 4.18m (13.71ft),  Average Daily Traffic: 29,829 (year 2020),  Truck Traffic: 23%,  Average Future Daily Traffic: 37,286 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SANTAQUIN MAIN ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 394.343,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 12.1m (39.7ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 46.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 28.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3F 197,  Location: SO.SANTAQUIN INTERCHANGE (Lat: 39.950878,  Lng: -111.802639),  Route carried "on" structure: Interstate 15,  Year Built: 1973,  Status: Open,  Structure Length: 3.19m (10.47ft),  Average Daily Traffic: 27,142 (year 2020),  Truck Traffic: 25%,  Average Future Daily Traffic: 33,928 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: COUNTY RD INT X-ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 390.542,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 31.1m (102.0ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 35.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 15.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: D 749,  Location: 2.1 MI NO OF SANTAQUIN (Lat: 40.004669,  Lng: -111.763000),  Route carried "under" structure: Interstate 15,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 42,776 (year 2020),  Truck Traffic: 22%,  Features Intersected: I-15 (SR-15) NBL & S,  Facility Carried by Structure: 12400 South
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 397.389,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 1C 763,  Location: SW.SIDE OF SANTAQUIN (Lat: 39.965683,  Lng: -111.785197),  Route carried "under" structure: County highway ,  Year Built: 1989,  Structure Length: 0. m,  Features Intersected: SANTAQUIN CANYON ROAD,  Facility Carried by Structure: I-15 (SR-15) NBL
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 1F 128,  Location: SANTAQUIN INTERCHANGE (Lat: 39.975336,  Lng: -111.772417),  Route carried "under" structure: US 6,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 16,882 (year 2020),  Truck Traffic: 9%,  Features Intersected: US-6 (SR-6), INT. X-ROAD,  Facility Carried by Structure: I-15 (SR-15) NBL
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 258.354,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.0m (59.1ft)

Find on map >>   Show street view

Structure Number: 1F 197,  Location: SO.SANTAQUIN INTERCHANGE (Lat: 39.950400,  Lng: -111.802653),  Route carried "under" structure: County highway ,  Year Built: 1973,  Structure Length: 0. m,  Features Intersected: COUNTY RD.INT.X-ROAD.,  Facility Carried by Structure: I-15 (SR-15) NBL
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.1m (102.0ft)

Find on map >>   Show street view

Structure Number: 3C 763,  Location: SW SIDE OF SANTAQUIN (Lat: 39.966239,  Lng: -111.784903),  Route carried "under" structure: County highway ,  Year Built: 1989,  Structure Length: 0. m,  Features Intersected: SANTAQUIN CANYON ROAD,  Facility Carried by Structure: I-15 (SR-15) SBL
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 3F 128,  Location: SANTAQUIN INTERCHANGE (Lat: 39.975789,  Lng: -111.772367),  Route carried "under" structure: US 6,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 16,882 (year 2020),  Truck Traffic: 9%,  Features Intersected: SANTAQUIN MAIN ST,  Facility Carried by Structure: I-15 (SR-15) SBL
Minimum Vertical Clearance: 5.46m (17.91ft),  Kilometerpoint: 258.321,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.0m (59.1ft)

Find on map >>   Show street view

Structure Number: 3F 197,  Location: SO.SANTAQUIN INTERCHANGE (Lat: 39.950878,  Lng: -111.802639),  Route carried "under" structure: County highway ,  Year Built: 1973,  Structure Length: 0. m,  Features Intersected: COUNTY RD INT X-ROAD,  Facility Carried by Structure: I-15 (SR-15) SBL
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.1m (102.0ft)

Discuss Santaquin, Utah (UT) on our hugely popular Utah forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.